PubMed Health⌕ Search

Biomedical subjects

Luc Beaulieu

Publications and source records attributed to Luc Beaulieu.

22 records · Page 2Linked to original sources

Simultaneous optimization of beam orientations, wedge filters and field weights for inverse planning with anatomy-based MLC fields.

As an alternative between manual planning and beamlet-based IMRT, we have developed an optimization system for inverse planning with anatomy-based MLC fields. In this system, named Ballista, the orientation (table and gantry), the wedge filter and the field weights are simultaneously optimized for every beam. An interesting feature is that the system is coupled to Pinnacle3 by means of the PinnComm interface, and uses its convolution dose calculation engine. A fully automatic MLC segmentation algorithm is also included. The plan evaluation is based on a quasi-random sampling and on a quadratic objective function with penalty-like constraints. For efficiency, optimal wedge angles and wedge orientations are determined using the concept of the super-omni wedge. A bound-constrained quasi-Newton algorithm performs field weight optimization, while a fast simulated annealing algorithm selects the optimal beam orientations. Moreover, in order to generate directly deliverable plans, the following practical considerations have been incorporated in the system: collision between the gantry and the table as well as avoidance of the radio-opaque elements of a table top. We illustrate the performance of the new system on two patients. In a rhabdomyosarcoma case, the system generated plans improving both the target coverage and the sparing of the parotide, as compared to a manually designed plan. In the second case presented, the system successfully produced an adequate plan for the treatment of the prostate while avoiding both hip prostheses. For the many cases where full IMRT may not be necessary, the system efficiently generates satisfactory plans meeting the clinical objectives, while keeping the treatment verification much simpler.

Algorithms↗

Automatic post-implant needle reconstruction algorithm to characterize and improve implant robustness analyses.

Post-implant analysis in permanent implant brachytherapy is an important process that provides a feedback on treatment quality. Random seed movements, edema, and needle related factors contribute to deteriorate dose coverage. For a complete study of these movements, it is important to reconstruct the post-implant seeds clusters but, up to now, this task was only possible via a long and difficult manual process. To facilitate post-implant analysis a simulated annealing algorithm was developed to perform automatic reconstructions. This process is fast (30-60 s on a 1.3 GHz pentium) and has a high level of success, even with up to 5% of seed loss. Tests on 21 clinical cases show that the algorithm yields exactly the same results as manual reconstructions. A realistic simulation tool was used to generate 58 synthetic post-implant data, in which cases the exact configuration was known. Even if some errors were found, pertinent information was extracted. For medium seed density [corresponding to seeds of 0.6 mCi (0.762 U)], 97% of seeds are matched with their correct needle and 89% are matched with their correct planned position. This method provides pertinent information that can be used to understand inhomogenous dose coverage in specific prostate quadrants; to make realistic post-implant simulations or to identify seeds belonging to a needle loaded with different seed types or activity.

Algorithms↗

Early clinical experience with anatomy-based inverse planning dose optimization for high-dose-rate boost of the prostate.

PURPOSE: To present an exhaustive dosimetric comparison between three geometric optimization methods and our inverse-planning simulated annealing (IPSA) algorithm, with two different prescriptions for high-dose-rate (HDR) boost of the prostate. The objective of this analysis was to quantify the dosimetric advantages of the IPSA algorithm compared with more standard geometric optimizations. METHODS AND MATERIALS: Between September 1999 and June 2001, 34 patients were treated to a dose of 40-44 Gy by external pelvic fields, followed by an HDR boost of 18 Gy in 3 fractions. The first 4 patients were treated with HDR using geometric optimization, and anatomy-based inverse-planning dose optimization was used for the remaining 30 patients. We retrospectively used the data from these 30 patients to create HDR dose distributions according to five different dose optimization protocols, including our IPSA algorithm. The various geometric optimization procedures differed in the way the dwell positions were activated and plan normalization was performed. Dose-volume histograms from all these plans were analyzed and multiple implant quality indexes extracted. RESULTS: The IPSA algorithm provided better clinical tumor volume prescription dose coverage than did the geometric optimizations. The average prostate volume receiving 100% of the prescribed dose (V100) was 96.3% and 94.5% for IPSA with two different prescriptions compared with 92.1%, 92.6%, and 88.8% for the three geometric optimization schemes. The average urethra V150 value was 0.0% and 0.7% for IPSA with two different prescriptions, and the three geometric optimization protocols generated average values of 22.9%, 33.9%, and 38.8%. The bladder and rectal dose-volume histograms were similar, although the latest version of the IPSA algorithm slightly decreases the dose to these organs at risk because of organ-specific dose constraints included in the objective function. CONCLUSION: We found that planning an HDR prostate boost could be performed in a fast, secure, and effective manner with the IPSA algorithm. We demonstrated that our inverse-planning algorithm produces superior HDR plans than more conventional geometric optimizations for adenocarcinoma of the prostate. The organs at risk protection included in the objective function is a major feature of the algorithm and should allow us to escalate the HDR dose to the prostate without increasing undesirable side effects.

Adenocarcinoma↗

Dosimetric impact of the variation of the prostate volume and shape between pretreatment planning and treatment procedure.

PURPOSE: The goal of this study is to evaluate the dosimetric impact on a pretreatment planning of prostatic volume and shape variations occurring between the moment of the volume study (preplanning) and just before a transperineal permanent seed implant procedure. Such variations could be an obvious source of misplacement of the seeds relative to the prostate gland and organs at risk. Other sources of dosimetric uncertainties, such as misplacement due to the procedure itself or edema, are eliminated by looking at these variations before the implant procedure. METHODS AND MATERIALS: For 35 clinical cases, prostate contours were taken at preplanning time as well as in the operating room (OR) minutes before the procedure. Comparison of shape and volume between the two sets was made. The impact on V100 was evaluated by placing the seeds in their planned positions in the new volume (clinical situation) and also by performing a new plan with the second set of contours to simulate an intraoperative approach. RESULTS: The volume taken in the OR remained unchanged compared to the pretreatment planning volume in only 37% of the cases. While on average the dose coverage loss from pretreatment planning due to a combination of variations of volume and shape was small at 5.7%, a V100 degradation of up to 20.9% was observed in extreme cases. Even in cases in which no changes in volume were observed, changes in shape occurred and strongly affected implant dosimetry. CONCLUSIONS: Variations of volume and shape between pretreatment planning and the implant procedure can have a strong impact on the dosimetry if the planning and the implant procedure are not performed on the same day. This is an argument in favor of performing implant dosimetry in the OR.

Brachytherapy↗