Techniques in carotid artery stenting.

Endovascular carotid artery interventions are unforgiving of mistakes and poor technique. The approach should be team based where all members of the team are experienced and know their jobs perfectly. This, combined with a deep knowledge of the equipment and the anatomy will reduce complications to a minimum. Patient selection and the experience of knowing how to "get out of jail" are also vital.

Blood Vessel Prosthesis↗

Endovascular treatment of a ureteroiliac fistula associated with ureteral double J-stenting and an aortic-bifemoral stent graft for an inflammatory abdominal aortic aneurysm.

We report an unusual case of a ureteroiliac fistula due to prolonged ureteral stenting for hydronephrosis combined with an aortic-bifemoral stent graft in an inflammatory abdominal aortic aneurysm (AAA), treated with an endovascular stent graft. In a 77-year-old man ureteral J-stents were placed for bilateral hydronephrosis due to retroperitoneal fibrosis caused by an inflammatory AAA. The aneurysm was treated with an endovascular aortic-bifemoral stent graft. Three months later, the patient suffered from severe hypovolemic shock. Emergency angiography showed a fistula between the right ureter and the right common iliac artery just distal to the right leg of the stent graft. The ureteroiliac fistula was treated with a wall graft (10F). The patient recovered well and remained asymptomatic. Ureteroiliac fistula remains a rare complication of ureteral stenting. Several risk factors have been described before. This case emphazes the increased risk of an arterial-ureteral fistula due to an indwelling ureteral stent and an inflammatory AAA, especially in combination with an additional stent graft for this inflammatory AAA.

Aged↗

European carotid PROCAR Trial: prospective multicenter trial to evaluate the safety and performance of the ev3 Protégé stent in the treatment of carotid artery stenosis--1- and 6-month follow-up.

BACKGROUND: The purpose of the European PROCAR Trial was to evaluate the safety and performance of the Protégé stent in the treatment of common and/or internal carotid artery stenoses with adjunctive use of a filter embolic protection device. METHOD: The Protégé GPS stent is a self-expanding Nitinol stent system mounted on a 6 Fr 0.018'' (6-9 mm stent) or 7 Fr 0.035'' (10 mm stent) over-the-wire delivery system. Study patient assessments were conducted at baseline, periprocedure, discharge, and 1 and 6 months postprocedure. A total of 77 patients have been enrolled in the trial. RESULTS: In the 77 lesions treated (31 symptomatic, 46 asymptomatic), the procedure was technically successful in 76 (99%), with an average residual stenosis of less than 30%. One procedure failed because the embolic protection device could not be retrieved and the patient was sent to surgery. Within 30 days, there were four (5.2%) major adverse neurological events (MANEs). Three of the MANEs were major strokes (3.9%), one a minor stroke. The fifth MANE occurred prior to the 6-month follow-up visit; this patient had a major stroke 75 days after the procedure and died 36 days later. One additional death occurred because of urosepsis. CONCLUSIONS: The PROCAR trial shows that the Protégé stent with adjuvant use of a filter embolic protection device satisfies safety and performance criteria for the treatment of carotid artery stenosis. The incidence of MANEs for the Protégé stent is comparable to the incidence of these events in other recent carotid stent studies and standard carotid endarterectomy (CEA).

Aged↗

Belgian experience with FilterWire EX in the prevention of embolic events during carotid stenting.

PURPOSE: To evaluate the performance of the FilterWire EX for the capture and removal of debris and prevention of embolic events during endovascular carotid interventions. METHODS: In the period from October 2001 to May 2002, 100 patients (60 men; mean age 72 years, range 48-90), 69 symptomatic with >or=50% internal carotid artery (ICA) stenosis and 31 asymptomatic with >or=70% stenosis were scheduled for carotid stenting with cerebral protection provided by the FilterWire EX system. Satisfactory performance of the filter was defined as effectiveness in preventing intraprocedural embolic events shown by visible debris in the filter and unchanged neurological status assessed by an independent neurologist. RESULTS: The placement and retrieval of the FilterWire EX was technically successful in 93 of 100 patients. Five delivery failures were due to severe ICA angulation; one stenosis was underestimated on preprocedural imaging, and one case was aborted following a major stroke during sheath manipulation before filter introduction. In 56.9% of the protected cases, the filter contained debris. One neurological event occurred 6 hours after the procedure: a transient ischemic attack from which the patient recovered fully after 2 hours. No other procedure-related events were recorded within 30 days of the procedure. The procedural success among the 93 patients stented under FilterWire EX protection was 98% (92% by intention to treat). CONCLUSION: The FilterWire EX appears to be an effective tool in the prevention of embolic events and in preserving neurological status during endovascular treatment of carotid artery stenosis.

Aged↗