Effect of cyclic loading on new polyblend suture coupled with different anchors.

BACKGROUND: Secure tendon-to-bone fixation is essential for successful rotator cuff repair. Biomechanical properties of devices used in rotator cuff repair should be better understood. PURPOSE: To evaluate the response to incremental cyclic loading of 6 different anchor-suture complexes commonly used in rotator cuff repair. STUDY DESIGN: Controlled laboratory study. METHODS: Two absorbable anchors 5 mm and 6.5 mm in diameter and 1 metallic anchor, coupled with Ethibond or FiberWire, were tested on 5 pairs of fresh-frozen human cadaveric shoulders. An incremental cyclic load was applied until failure using a Zwich-Roell Z010 electromechanical testing machine. The ultimate failure load and mode of failure were recorded. An analysis of variance model was used for statistical analysis. RESULTS: The FiberWire suture coupled with both absorbable and metallic anchors provided statistically significantly stronger fixation. However, although the metallic anchors in most cases failed because of slippage of the anchor, absorbable anchors failed because of rupture of the eyelet. CONCLUSIONS: The FiberWire seems to increase the strength of fixation devices under cyclic load using both absorbable and metallic anchors, with relevant differences in failure mode (slippage of the metallic anchor and eyelet failure in the absorbable anchor). CLINICAL RELEVANCE: Use of the FiberWire suture might change the mode of failure of the suture-anchor complexes.

Aged↗

Evolgate fixation of doubled flexor graft in anterior cruciate ligament reconstruction: biomechanical evaluation with cyclic loading.

BACKGROUND: The weakest points in hamstrings anterior cruciate ligament reconstruction are its points of fixation, especially on the tibial side. Methods for graft fixation to bone should be strong enough to avoid failure, stiff enough to restore load-displacement response, and secure enough to resist slippage under cyclic loading. HYPOTHESIS: Biomechanical properties of the interference screw can be improved by reinforcing the walls of the tunnel with a metal spiral (Evolgate fixation). STUDY DESIGN: Controlled laboratory study. METHODS: Three paired tests were performed using common digital extensor bovine tendons fixed to porcine tibias with interference screw, Intrafix, and Evolgate; critical graft fixation conditions were simulated by applying subsequent cycles to the graft before loading the graft until failure. RESULTS: The strength, stiffness, and resistance to slippage of the Evolgate were significantly higher than those of the interference screw; the ultimate failure load of the Evolgate was significantly higher than that of the Intrafix (1058+/-130 N and 832+/-156 N, respectively; P=.02). No statistically significant differences were found between Evolgate and Intrafix regarding the stiffness and slippage under cyclic load. CONCLUSION: Evolgate fixation seems to be stronger, stiffer, and more resistant to slippage than is interference screw fixation of similar length, and it is stronger but not stiffer than Intrafix. CLINICAL RELEVANCE: The Evolgate provides structural properties that seem to be appropriate for an intensive rehabilitation after anterior cruciate ligament reconstruction using a doubled semitendinosus and gracilis graft.

Alloys↗