PubMed Health⌕ Search

Biomedical subjects

Lucia J M Kroft

Publications and source records attributed to Lucia J M Kroft.

11 recordsLinked to original sources

Right ventricular function in patients with acute pulmonary embolism: analysis with electrocardiography-synchronized multi-detector row CT.

PURPOSE: To prospectively assess electrocardiography (ECG)-synchronized multi-detector row computed tomography (CT) for the evaluation of right ventricular (RV) function in patients suspected of having pulmonary embolism (PE). MATERIALS AND METHODS: All patients gave informed consent after the study details, including radiation exposure, were explained; institutional ethical committee approval was obtained. Nonsynchronized multi-detector row CT of the chest was performed in 66 consecutive patients (29 men, 37 women; mean age, 58 years+/-15 [standard deviation]) who were suspected of having PE. ECG-synchronized cardiac multi-detector row CT was performed to assess cardiac function. Dimension ratios for the RV and left ventricle (LV) were measured on nonsynchronized transverse and angulated four-chamber views. Furthermore, the RV end-diastolic and end-systolic volumes were measured on ECG-synchronized multi-detector row CT scans. An independent samples t test was performed to compare the mean value of different groups. An analysis of variance post hoc test was performed to investigate whether the values of the variables varied between groups. RESULTS: PE was detected in 29 of 66 patients. The location of PE was categorized as central (n=17) or peripheral (n=12). The RV/LV dimension ratio was larger on the four-chamber view (P=.002), and RV end-systolic volume was larger (P=.01) and ejection fraction was lower (P=.01) in patients with PE. The RV end-systolic volumes and RV/LV volume ratios, as assessed by using ECG-synchronized multi-detector row CT, showed significant differences (P<.005) between patients with central PE and those with peripheral PE. However, the RV/LV dimensions on nonsynchronized images revealed no significant differences. CONCLUSION: Retrospective ECG-synchronized multi-detector row CT facilitates detection of RV dysfunction, depending on pulmonary embolus location.

Acute Disease↗

Aortic root dysfunctioning and its effect on left ventricular function in Ross procedure patients assessed with magnetic resonance imaging.

BACKGROUND: This study evaluated the diameters and distensibility of the aortic root as well as the degree of aortic regurgitation (AR) and its effect on left ventricular (LV) function in patients 8.2 +/- 3.1 years after they underwent the Ross procedure, with a comparison of these parameters between patients and matched healthy subjects. METHODS: Eighteen Ross procedure patients (16 male patients, age [mean +/- SD] 19.2 +/- 3.8 years) and 18 matched healthy subjects (16 male patients, age [mean +/- SD] 19.7 +/- 4.2 years) underwent magnetic resonance imaging. Measurements for diameters (at 4 levels) and the distensibility of the aortic root were performed using a steady-state free precession sequence. Aortic flow was assessed with a velocity-encoded phase-contrast sequence. Left ventricular systolic function was assessed with a gradient-echo sequence in the short-axis plane. Comparison of parameters was performed using the Mann-Whitney U test. Correlations between diameters, distensibility, AR fraction, and LV systolic function were expressed with Spearman rank correlation coefficients. Linear regression analysis was used to identify predictors of LV systolic dysfunction. RESULTS: Aortic root diameters were increased in Ross procedure patients as compared with healthy subjects (mean difference 6.3-11.6 mm, P < or = .02 at all 4 levels). Distensibility of the aortic root was lower in patients (1.9 +/- 1.1 vs 7.8 +/- 3.3 mm Hg(-1), P < .01). An AR fraction > 5% was present in 14 of the 18 patients (mean AR fraction 8% +/- 5% vs 1% +/- 1%, P < .01). Left ventricular ejection fraction was lower in patients (50% +/- 6% vs 57% +/- 6%, P < .01). Dilatation, decreased distensibility, and AR fraction were correlated with impaired LV systolic function (P < .05 for all). The AR fraction predicted impaired LV systolic function (P < .01). CONCLUSIONS: Magnetic resonance imaging shows dilatation and decreased distensibility of the aortic root, AR, and consequent impaired LV systolic function in patients after the Ross procedure.

Adolescent↗

Detection of simulated nodules on clinical radiographs: dose reduction at digital posteroanterior chest radiography.

PURPOSE: To determine to what extent dose reduction results in decreased detection of simulated nodules on patient digital posteroanterior (PA) chest radiographs. MATERIALS AND METHODS: Raw data from 20 clinical digital PA chest images that were reported as having normal findings and that were obtained with a slot-scan charge-coupled device system were used. For research protocol that concerns data with patient identities concealed, institutional review board approval is not required. One hundred twenty nodules varying in size and signal intensity were digitally simulated and added to the chest images. Hard copies were printed to represent a 100% dose and, by adding noise, to represent simulated patient doses of 50%, 25%, and 12%. Four radiologists reviewed images. Each lesion was registered as "detected" or "not detected." A semiparametric logistic regression model was used for statistical analysis. RESULTS: The decrease in radiation dose from 100% to 50%, 25%, or 12% had no effect on lesion detection in the lungs. The decrease in radiation dose had an effect on lesion detection in the mediastinum, as probabilities deteriorated from the 100% dose to the 50%, 25%, and 12% dose with each step. Probabilities of smaller detection rates when compared with that of the reference category (100% dose) were 0.97 (95% confidence interval [CI]: -0.86, 0.012) for the 50% dose, 1 (CI: -0.59, -0.61) for the 25% dose, and 1 (CI: -2.41, -1.22) for the 12% dose. CIs for the effects were on the log(odds). Detection probability decreased with smaller and lower signal intensity lesions. CONCLUSION: At clinical digital radiography, dose reduction resulted in decreased observer detection of simulated nodules in the mediastinum but not in the lungs.

Bayes Theorem↗

MDCT assessment of right ventricular systolic function.

OBJECTIVE: The objective of our study was to validate using MDCT for the assessment of right ventricular (RV) function. MDCT with retrospective ECG gating was performed in 15 patients being evaluated for suspected cardiovascular disease. Echocardiography was performed for comparison. The MDCT images were reconstructed at 20 phase points over the cardiac cycle. The end-diastolic and end-systolic volumes of both ventricles were measured. Stroke volumes and ejection fractions were calculated from these data. CONCLUSION: RV volumes can be accurately assessed using MDCT.

Electrocardiography↗

Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice.

The purpose of this study was to assess contrast-detail performance and effective dose of eight different digital chest radiography systems. Digital chest radiography systems from different manufacturers were included: one storage phosphor system, one selenium-coated drum system, and six direct readout systems including four thin-film transistor (TFT) systems and two charge-coupled device (CCD) systems. For measuring image quality, a contrast-detail test object was used in combination with a phantom that simulates the primary and scatter transmission through lung fields (LucAl). Six observers judged phantom images of each modality by soft-copy reading in a four-alternative-forced-choice experiment. The entrance dose was also measured, and the effective dose was calculated for an average patient. Contrast-detail curves were constructed from the observer data. The blocked two-way ANOVA test was used for statistical analysis. Significant difference in contrast-detail performance was found between the systems. Best contrast-detail performance was shown by a CCD system with slot-scan technology, and the selenium-coated drum system was compared to the other six systems (p values <or=0.003). Calculated effective dose varied between 0.010 mSv and 0.032 mSv. Significant differences in contrast-detail performance and effective dose levels were found between different digital chest radiography systems in clinical practice.

Equipment Design↗

Digital slot-scan charge-coupled device radiography versus AMBER and Bucky screen-film radiography: comparison of image quality in a phantom study.

PURPOSE: To evaluate the image quality and performance of a chest digital radiography system and to compare this with the image quality and performance of advanced multiple-beam equalization radiography (AMBER) and Bucky screen-film radiography systems. MATERIALS AND METHODS: The chest digital radiography system is a digital charge-coupled device (CCD) chest imaging unit that uses slot-scan technology. A contrast-detail test object was used in combination with a phantom that simulates the primary and scatter transmission for the lungs and mediastinum. Twelve phantom images were obtained with each modality (ie, CCD digital radiography and AMBER and Bucky screen-film radiography) and were judged by six observers. CCD digital radiography soft-copy reading was compared with AMBER hard-copy reading. To measure image quality, contrast-detail curves were constructed from the observer data. The Wilcoxon signed rank test was used for statistical analysis. RESULTS: For the lung configuration, contrast-detail curves showed lower threshold depth for hard-copy images obtained with CCD digital radiography than for those obtained with Bucky screen-film radiography. For hard-copy images, the difference between contrast-detail curves for CCD digital radiography and those for Bucky screen-film radiography was statistically significant (P < .006). No significant difference was found between CCD digital radiography and AMBER for hard-copy images obtained in either the lung or mediastinum configuration. For the lung configuration, a lower threshold depth was observed for CCD digital radiography soft-copy reading than for AMBER hard-copy reading, with significantly different contrast-detail curves for CCD digital radiography soft copy and AMBER hard copy (P < .006). No significant difference was found between either system for the mediastinum configuration. CONCLUSION: Contrast-detail curves indicate that image quality for the CCD chest system provides a digital alternative to AMBER and Bucky screen-film radiography.

Phantoms, Imaging↗

Radiofrequency ablation for treatment of symptomatic low-flow vascular malformations after previous unsuccessful therapy.

Three patients with low-flow soft-tissue vascular malformations were treated with radiofrequency (RF) ablation. Other treatment options had proven unsuccessful. After RF ablation treatment, two patients were free of symptoms and one reported decreased symptoms followed by a return of symptoms within 1 year. No procedure-related complications occurred. It is suggested that RF ablation may be offered as an alternative treatment option for symptomatic vascular malformations when others have failed or are not possible.

Adult↗

Comparison of eight different digital chest radiography systems: variation in detection of simulated chest disease.

OBJECTIVE: In a short period, a variety of technically different digital radiography chest systems have become available for clinical use. Our purpose was to assess the diagnostic performance of eight different digital radiography chest systems for detection of simulated chest disease under clinical conditions. MATERIALS AND METHODS: Assessed were four different flat-panel detector systems, two different charge-coupled device systems, one selenium-coated drum, and one storage phosphor system. For each system, 10 chest images of an anthropomorphic chest phantom were obtained. Each image contained one to 12 simulated chest lesions. Eight radiologists performed soft-copy interpretations. Entrance dose was measured and effective dose calculated. A semi-parametric logistic regression model was used for statistical analysis. RESULTS: Statistically significant differences were found in the diagnostic performance of the eight digital chest systems (p = 0.01). Best performance was observed with the charge-coupled device system with slot-scan technology, yielding a sensitivity of 46% (132 of 288) lesions detected. The performance of three flat-panel detectors and the selenium-drum system was not significantly different from the slot-scan charge-coupled device system. Fewer lesions were detected with the storage phosphor system than with all other digital technologies, with a sensitivity of 34% (99 of 288) lesions detected, slot-scan charge-coupled device system versus storage phosphor system, p < 0.001. The effective dose varied among the digital systems. CONCLUSION: We found differences in diagnostic performance among the eight different digital chest systems. Differences in detection rates are predominantly explained by detector design.

Diagnostic Errors↗

Rheumatoid arthritis: epidural enhancement as an underestimated cause of subaxial cervical spinal stenosis.

PURPOSE: To assess the frequency and site of subaxial spinal canal stenosis due to enhancing tissue in patients with rheumatoid arthritis. MATERIALS AND METHODS: Data from 33 consecutive patients with rheumatoid arthritis were evaluated; these patients had undergone 1.5-T magnetic resonance imaging following gadolinium chelate administration, in combination with a frequency selective fat-suppression technique. Stenosis and enhancement were scored for each of six cervical spinal levels and were compared with results in a control population consisting of 16 patients with degenerative disease. Enhancement was scored as superficial or deep on the anterior and posterior sides from the cervical spinal cord. Differences between patient groups were tested by using the chi(2) test for trend and the Fisher exact test. RESULTS: No significant difference was found in the frequency or severity of subaxial stenosis between rheumatoid arthritis and degenerative disease. Deep epidural enhancement was observed more often with rheumatoid arthritis than with degenerative disease both anterior (25 of 33 patients vs seven of 16 patients, respectively; P <.001) and posterior (24 of 33 patients vs two of 16 patients, respectively; P =.001) to the spinal cord. Enhancing stenosing tissue in rheumatoid arthritis frequently occurred anterior and posterior at the same time and at the same level, with segmental cufflike extension of enhancing tissue around the dural sac. Stenosing tissue enhanced more frequently with rheumatoid arthritis than with degenerative disease (22 of 33 vs four of 16 patients, respectively; P =.008). CONCLUSION: In patients with rheumatoid arthritis, subaxial stenosis is frequently caused by enhancing epidural tissue. This enhancing tissue presumably represents pannus.

Adult↗

Digital slot-scan charge-coupled device radiography versus AMBER and Bucky screen-film radiography for detection of simulated nodules and interstitial disease in a chest phantom.

PURPOSE: To evaluate the diagnostic performance of full-field slot-scan charge-coupled device (CCD)-based digital radiography in the detection of simulated chest diseases in clinical conditions versus that of two screen-film techniques: advanced multiple beam equalization radiography (AMBER) and Bucky radiography. MATERIALS AND METHODS: Simulated nodules and interstitial nodular and interstitial linear lesions were attached onto an anthropomorphic chest phantom. One hundred sixty-eight lesions were distributed over 25 configurations. A posteroanterior chest radiograph of each configuration was obtained with each technique. The images were presented to six observers. Each lesion was assigned one of two outcome scores: "detected" or "not detected." False-positive readings were evaluated. Differences between the imaging methods were analyzed by using a semiparametric logistic regression model. RESULTS: For simulated nodules and interstitial linear disease, no statistically significant difference was found in diagnostic performance between CCD digital radiography and AMBER. The detection of simulated interstitial nodular disease was better with CCD digital radiography than with AMBER: Sensitivity was 71% (77 of 108 interstitial nodular lesions) with CCD digital radiography but was 56% (60 of 108 lesions) with AMBER (P =.041). Better results for the detection of all lesion types in the mediastinum were observed with CCD digital radiography than with Bucky screen-film radiography: Sensitivity was 45% (227 of 504 total simulated lesions) with CCD digital radiography but was 24% (119 of 504 lesions) with Bucky radiography (P <.001). There were fewer false-positive observations with CCD digital radiography (35 [5.7%] of 609 observations) than with Bucky radiography (47 [9.5%] of 497 observations; P =.012). CONCLUSION: Differences were in favor of the full-field slot-scan CCD digital radiographic technique. This technique provides a digital alternative to AMBER and Bucky screen-film radiography.

Dose-Response Relationship, Radiation↗