PubMed Health⌕ Search

Biomedical subjects

Lucio F C Melo

Publications and source records attributed to Lucio F C Melo.

2 recordsLinked to original sources

High-performance liquid chromatographic determination of pesticides in tomatoes using laboratory-made NH2 and C18 solid-phase extraction materials.

A method for high-performance liquid chromatographic (HPLC) multiresidue determination of six pesticides in tomatoes was developed and validated. Silica-based C18 (octadecyl) and NH2 (aminopropyl) solid-phase extraction (SPE) sorbents, made in our laboratory, were used for sample preparation. The SPE materials were obtained by thermal immobilization of appropriate polysiloxanes onto 40 microm silica surfaces and were used in sample preparation for multiresidue analysis of the following pesticides: tebuthiuron and diuron (urea herbicides), simazine, atrazine and ametryn (triazines herbicides) and benomyl (benzimidazol fungicide). The results were compared with similar commercial materials. Reversed-phase high-performance liquid chromatography (RP-HPLC) using a Purospher RP-18 5 microm column and ACN: 0.01% aqueous NH4OH, pH 8.4 (35:65, v/v) as mobile phase, at 0.7 mlmin(-1), with 235 nm UV detection, was used for separation and quantification of the pesticides. Method validation was performed at three fortification levels (100, 200, 1000 microg l(-1)). Limits of detection and quantification show that the methods developed can be used to detect the pesticides in concentrations below the maximum residue levels (MRL) established by the Codex Alimentarius, USA, European Union and Brazilian legislations. The results showed that aminopropyl materials have a better performance than the octadecyl sorbents. Laboratory-made materials give results similar to commercial sorbents, with recoveries and precisions in agreement with directives for method validation in residue analysis.

Chromatography, High Pressure Liquid↗

New materials for solid-phase extraction and multiclass high-performance liquid chromatographic analysis of pesticides in grapes.

Sample preparation procedures which included the use of new aminopropyl (NH2) and octadecyl (C18) solid-phase extraction (SPE) sorbents are proposed for the simultaneous multiclass determination of the fungicide benomyl and of the herbicides tebuthiuron, diuron, simazine, atrazine, and ametryn in grapes, using single wavelength high-performance liquid chromatography. Sorbent preparation uses a fast, easy, and effective procedure to obtain silica-based materials, made by depositing polysiloxanes on a silica support followed by thermal immobilization. Recovery results of the compounds, after elution from the SPE cartridges, indicate that the most efficient system employed silica loaded with 40% of an aminofunctional polydimethylsiloxane as sorbent, using dichloromethane:methanol (95:5, v/v) as eluent. Method validation, carried out in agreement with International Conference on Harmonization directives, was performed at three fortification levels (100, 200, and 1000 microg kg(-1)). Limits of detection and quantification show that the method developed can be used to detect the pesticides at concentrations below the maximum residue levels established by Codex Alimentarius, the US Environmental Protection Agency, the European Union, and Brazilian legislation.

Chromatography, High Pressure Liquid↗