PubMed Health⌕ Search

Biomedical subjects

Lufan Zou

Publications and source records attributed to Lufan Zou.

9 recordsLinked to original sources

Effect of Brillouin slow light on distributed Brillouin fiber sensors.

The effect of Brillouin slow light on distributed Brillouin fiber sensors (DBFSs) is studied. We demonstrate Brillouin slow light for a 1.2 ns pulse with peak powers (PS) from 3.3 to 56.2 mW on depletion of the pump power (PP) ranging from 1.3 to 83.2 mW in conventional optical fibers (SMF-28). Experiments show that, when pump power depletion is not negligible, for a given PP the Brillouin gain and delay time of a pulse decrease when PS increases in a long (> or =10 km) sensing fiber. The optimum pump beam depletion resulting from strong interaction of the pump and the probe in the fiber provides accurate temperature and strain information at a high spatial resolution. Our study reveals that at low PP the spatial resolution error caused by the pulse delay for a DBFS with centimeter spatial resolution is less than 5% of the pulse length.

Journal Article↗

Distributed Brillouin fiber sensor for detecting pipeline buckling in an energy pipe under internal pressure.

A distributed Brillouin fiber sensor has been employed to detect localized pipe-wall buckling in an energy pipe by measuring the longitudinal and hoop strain distributions along the outer surface of the pipe for the first time. The locations of the localized pipe-wall buckling are found and distinguished using their corresponding strain-load data. The formation of the buckling process for the compression and tension characters is studied in the longitudinal and hoop directions. For the pipe with internal pressure, concentric load, and bending load, a localized pipe-wall buckling takes place away from the middle of the pipe on the compressive side and a strain peak with an overall buckling occurs on the tensile side according to the longitudinal strain distributions along the pipe. Different strains on two neutral lines are also observed in the hoop strain distribution, which should be caused by the pipe weld joint.

Journal Article↗

Subpeaks in the Brillouin loss spectra of distributed fiber-optic sensors.

Subpeaks in the Brillouin loss spectra of distributed fiber-optic sensors were observed for what is believed to be the first time and studied. We discovered that the Fourier spectrum of the pulsed signal and the off-resonance oscillation both contributed to subpeaks. The off-resonance oscillation at frequency /v - vB/ is the oscillation in the Brillouin time domain when beat frequency v of the two counterpropagating laser beams does not match local Brillouin frequency vB. This study is important in differentiating the subpeaks from actual strain-temperature peaks.

Journal Article↗

Effect of optical phase on a distributed Brillouin sensor at centimeter spatial resolution.

Because of the power imbalance between the two arms of an interferometer in an electro-optic modulator (EOM), the output of the EOM is combined amplitude modulation (AM) and phase modulation (PM) for the probe signal consisting of the pulse and the dc component. Because of this PM, the Brillouin gain-loss spectrum becomes asymmetric. The central Brillouin frequency is shifted from that of an AM pulse. The maximum extinction ratio of the EOM is limited to approximately 29 dB for a power-splitting ratio of 51% to 49%. The asymmetric property induced by PM is not pulse shape dependent; for both Gaussian- and super-Gaussian-shaped pulses the Brillouin loss spectrum is symmetric for AM and asymmetric for combined AM and PM (power imbalance).

Journal Article↗

Brillouin spectral deconvolution method for centimeter spatial resolution and high-accuracy strain measurement in Brillouin sensors.

Combining a dc and a short pulse (approximately 1 ns) as the probe beam in the pump-probe configuration of Brillouin-based distributed sensors allows us to represent the Brillouin spectrum as a top Lorentzian-like portion and a bottom Gaussian-like portion. Because of the interaction of these two parts, the Lorentzian-like portion carries spatial information that can be extracted within centimeter spatial resolution. Using this information, we develop a spectrum deconvolution method, which considers the location correlation of the strain distribution, to find the number of Brillouin peaks and their frequencies in the top Lorentzian-like portion and hence achieve accurate strain information. An optimum level of dc to pulse power for the best signal and position detection capability is discussed.

Journal Article↗

Coherent probe-pump-based Brillouin sensor for centimeter-crack detection.

We provide a theoretical explanation for a coherent probe-pump-based Brillouin sensor system that achieves centimeter spatial resolution with high-frequency resolution. It was recently discovered that, when a combination of cw and pulsed light (the probe beam) interacts with a cw laser (the pump beam), centimeter spatial resolution with high-frequency resolution can be achieved even though the probe-pulse duration is 1.5 ns [Opt. Lett. 29, 1485 (2004)]. Our study reveals that the coherent portion inside the pulse length of these two interactions caused by the same phase is responsible for this behavior. It allows us to detect 1.5-cm outer-layer cracks on an optical ground-wire cable.

Journal Article↗

Dependence of the brillouin frequency shift on strain and temperature in a photonic crystal fiber.

The dependence of the Brillouin frequency shift on strain in a photonic crystal fiber (PCF) was measured at a wavelength of 1320 nm for the first time to the authors' knowledge. Together with measurements of the dependence of the Brillouin frequency shift on temperature in the PCF, we demonstrate the feasibility of the highly precise simultaneous measurement of temperature and strain by use of the PCF in a distributed Brillouin sensing system with a spatial resolution of 15 cm.

Journal Article↗

Distributed brillouin scattering sensor for discrimination of wall-thinning defects in steel pipe under internal pressure.

A distributed Brillouin scattering sensor has been employed to identify several inner wall cutouts in an end-capped steel pipe by measuring the axial and hoop strain distributions along the outer surface of the pipe. The locations of structural indentations that constitute 50-60% of the inner pipe wall are found and distinguished by use of their corresponding strain-pressure data. These results are quantified in terms of the fiber orientation, defect size and depth, and behavior relative to those of unperturbed pipe sections.

Journal Article↗

Brillouin scattering spectrum in photonic crystal fiber with a partially germanium-doped core.

The Brillouin scattering spectrum in a photonic crystal fiber (PCF) with a partially Ge-doped core is measured with a pump-probe technique at a wavelength of 1320 nm. One main peak and four subpeaks are observed. The main peak has a Lorentzian shape with the bandwidth deltanuB = 66 MHz. Its intensity is six times higher than that from a standard single-mode fiber measured under the same conditions, which is consistent with the ratio of (1/Aeff(PCF))/(1/Aeff(SMF)), where Aeff is the effective area of the fibers. The temperature coefficient for the main peak is 0.96 MHz/degrees C. We believe that the subpeaks are caused by an interaction between light-wave and guided modes of longitudinal acoustic waves in the graded-Ge-doped region, the silica region, and the microstructured cladding. An analysis of the guiding and antiguiding properties of the PCF for acoustic waves is presented.

Journal Article↗