In vivo dosimetry by an aSi-based EPID.

A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoiding many of the disadvantages associated with the use of two diode detectors (at the entrance and exit of the patient) as their periodic recalibration and their positioning. Irradiating water-equivalent phantoms of different thicknesses, a set of correlation functions F(w, l) were obtained by the ratio between St and Dm as a function of the phantom thickness, w, for a different field width, l. For the in vivo determination of Diso and Dm values, the water-equivalent thickness of the patients (along the beam central axis) was evaluated by means of the treatment planning system that uses CT scans calibrated in terms of the electron densities. The Diso and Dm values experimentally determined were compared with the stated doses D(iso,TPS) and D(m,TPS), determined by the treatment planning system for ten pelvic treatments. In particular, for each treatment four fields were checked in six fractions. In these conditions the agreement between the in vivo dosimetry and stated doses at the isocenter point were within 3%. Comparing the 480 dose values obtained in this work with those obtained for 30 patients tested with a similar method, which made use of a small ion-chamber positioned on the EPIDs to obtain the transmitted signal, a similar agreement was observed. The method here proposed is very practical and can be applied in every treatment fraction, supplying useful information about eventual patient dose variations due to the incorrect application of the quality assurance program based on the check of patient setup, machine setting, and calculations.

Humans↗

Virtual simulation: fifteen years later.

In the last two decades there was a radical change in radiotherapy setup. The growing availability of CT equipment and console for computer-aided treatment planning setup enabled the use of advanced technologies as conformal 3D radiation therapy in most centers. In particular in 1987 virtual simulation was proposed for setup. During its use a number of application modalities appeared. Virtual simulation in some centers is applied alone while in others it is associated with conventional simulation. However, from numerous reports published in last years it seems that virtual simulation significantly improves treatment quality independently of radical or palliative intent and of the size of treated volumes (high doses to small volumes or wide shaped fields). Some studies stressed that virtual simulation could significantly shorten treatment planning times with consequent cost reduction. The use of virtual simulation evidenced associated problems and in particular setup limitations due to the CT gantry size, the need to up-date the conventional modalities of setup verification according to the new technologies and more generally to up-date quality assurance procedures in an advanced technological setting. Finally there was the self-evident need of a better knowledge of the anatomy on axial sections, of tumor spread routes in particular.

Computer Simulation↗

Electron beam dosimetry of Total Skin Electron Therapy (TSET).

Total Skin Electron Therapy (TSET) was carried out using an electron beam with a nominal energy of 6 MeV. The beam was adequately filtered and angled in order to create dual fields. The uniformity of the dose distribution to the patient was 10%. The relative dosimetry of the dual beam was performed using a silicon diode and an ionization chamber in a standard water phantom. X-Omat V films were irradiated in a cylindrical PMMA phantom in order to obtain the dose distribution for the six TSET dual fields used in the treatment. Absolute dosimetry was carried out with a calibrated ionization chamber placed in a cylindrical water phantom. The dose contribution per monitor unit of the single dual beams was determined with this method.

Dose Fractionation, Radiation↗