PubMed Health⌕ Search

Biomedical subjects

Luigi Bianchi

Publications and source records attributed to Luigi Bianchi.

7 recordsLinked to original sources

An independent component analysis-based approach on ballistocardiogram artifact removing.

Interest about simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) data acquisition has rapidly increased during the last years because of the possibility that the combined method offers to join temporal and spatial resolution, providing in this way a powerful tool to investigate spontaneous and evoked brain activities. However, several intrinsic features of MRI scanning become sources of artifacts on EEG data. Noise sources of a highly predictable nature such as those related to the pulse MRI sequence and those determined by magnetic gradient switching during scanning do not represent a major problem and can be easily removed. On the contrary, the ballistocardiogram (BCG) artifact, a large signal visible on all EEG traces and related to cardiac activity inside the magnetic field, is determined by sources that are not fully stereotyped and causing important limitations in the use of artifact-removing strategies. Recently, it has been proposed to use independent component analysis (ICA) to remove BCG artifact from EEG signals. ICA is a statistical algorithm that allows blind separation of statistically independent sources when the only available information is represented by their linear combination. An important drawback with most ICA algorithms is that they exhibit a stochastic behavior: each run yields slightly different results such that the reliability of the estimated sources is difficult to assess. In this preliminary report, we present a method based on running the FastICA algorithm many times with slightly different initial conditions. Clustering structure in the signal space of the obtained components provides us with a new way to assess the reliability of the estimated sources.

Adult↗

BCI meeting 2005--workshop on technology: hardware and software.

This paper describes the outcome of discussions held during the Third International BCI Meeting at a workshop to review and evaluate the current state of BCI-related hardware and software. Technical requirements and current technologies, standardization procedures and future trends are covered. The main conclusion was recognition of the need to focus technical requirements on the users' needs and the need for consistent standards in BCI research.

Algorithms↗

Topiramate: effect on EEG interictal abnormalities and background activity in patients affected by focal epilepsy.

PURPOSE: To evaluate the effects of topiramate (TPM) on interictal epileptiform abnormalities (IEA) and background activity by means of a computerized EEG analysis, in adult patients affected by focal epilepsy, with or without secondarily generalization, treated with TPM as adjunctive therapy or monotherapy. METHODS: Twenty-four patients affected by symptomatic or cryptogenic focal epilepsy underwent long-term video-EEG recording before and after TPM addition (mean dose 175+/-25 mg per day). RESULTS: TPM addition induced a significant reduction of both partial and secondarily generalized tonic-clonic (SGTC) seizures; treatment responder patients (seizure reduction > or = 50%) were 19 out of 24 patients (79.1%), of whom 5 were seizure-free. Quantitative analysis of IEA showed a significant decrease in the mean number of spikes/10 min during TPM therapy ( 4.2+/-4.2 versus 2.2+/-4.4; P<0.003 ). The analysis of spatial distribution of interictal spikes showed that such reduction was more evident at the level of the epileptogenic area rather than on the spreading component. Statistical analysis revealed only a significant decrease of mean relative power of alpha band in the EEG spectral content, recorded at rest in a group of 18 out of 24 epileptic patients during TPM therapy. In addition, during TPM treatment we observed a significant reduction in alpha reactivity without any important changes of alpha indexes (peak frequency and median frequency). CONCLUSION: These findings suggest that TPM has a strong inhibitory effect on IEA, probably acting on the generating processes, and, if used at low dosage and gradually titrated, seems to have only mild interferences with EEG background activity.

Adolescent↗

Simultaneous EEG-fMRI acquisition: how far is it from being a standardized technique?

Simultaneous EEG-fMRI is a powerful tool to study spontaneous and evoked brain activity because of the complementary advantages of the two techniques in terms of temporal and spatial resolution. In recent years, a significant number of scientific works have been published on this subject. However, many technical problems related to the intrinsic incompatibility of EEG and MRI methods are still not fully solved. Furthermore, simultaneous acquisition of EEG and event-related fMRI requires precise synchronization of all devices involved in the experimental setup. Thus, timing issue must be carefully considered in order to avoid significant methodological errors. The aim of the present work is to highlight and discuss some of technical and methodological open issues associated with the combined use of EEG and fMRI. These issues are presented in the context of preliminary data regarding simultaneous acquisition of event-related evoked potentials and BOLD images during a visual odd-ball paradigm.

Adult↗

Quantitative EEG and dynamic susceptibility contrast MRI in Alzheimer's disease: a correlative study.

OBJECTIVE: To investigate the relationship between the electroencephalographic (EEG) power spectra features obtained by quantitative EEG (qEEG) and the hemodynamic parameters detected by dynamic susceptibility contrast-enhanced MR imaging (DSC MRI) in patients with Alzheimer's disease (AD). METHODS: Fourteen patients with probable AD and 15 elderly healthy controls were included in the study. All subjects underwent both EEG recording in a rest condition and perfusion MRI. Three EEG scalp areas were defined (anterior, central and posterior) and power spectra values were obtained from each scalp area. Relative values of temporoparietal and sensorimotor regional cerebral blood volume (rCBV) were measured bilaterally and successively averaged to obtain a total perfusion index. The brain atrophy index was calculated and used as a covariate to rCBV. Correlation analysis was performed between EEG variables and hemodynamic-morphological parameters. RESULTS: qEEG power spectra of AD patients were characterized by an increase in mean relative power of theta (4-7.75 Hz) associated with a decrease in alpha (8-12.75 Hz) frequency bands with a topographic distribution over the central and posterior EEG scalp regions, when compared with controls; beta (13-31 Hz) frequency band also displayed a significant decrease over the anterior and posterior EEG scalp regions of AD patients with respect to controls. The DSC MRI revealed a bilateral reduction in the temporoparietal and sensorimotor rCBV with respect to controls. Correlation analysis showed that the total level of hypoperfusion selectively correlates with the EEG power spectra in theta and alpha frequency bands distributed over anterior/central and central region, respectively. Within AD patients, the lower the level of hypoperfusion, the higher the content of EEG power spectra in theta frequency band, and the lower the level of hypoperfusion, the lower the content of EEG power spectra in alpha band. CONCLUSIONS: The combined qEEG and DSC MRI technology unveiled a selective correlation between neurophysiological and hemodynamical patterns in AD patients. Further investigations will ascertain the relevance of this multi-modal approach in the heterogeneous clinical context of AD.

Aged↗

Developing wearable bio-feedback systems: a general-purpose platform.

Microprocessors, even those in PocketPCs, have adequate power for many real-time biofeedback applications for disabled people. This power allows design of portable or wearable devices that are smaller and lighter, and that have longer battery life compared to notebook-based systems. In this paper, we discuss a general-purpose hardware/software solution based on industrial or consumer devices and a C++ framework. Its flexibility and modularity make it adaptable to a wide range of situations. Moreover, its design minimizes system requirements and programming effort, thus allowing efficient systems to be built quickly and easily. Our design has been used to build two brain computer interface systems that were easily ported from the Win32 platform.

Biofeedback, Psychology↗

The use of EEG modifications due to motor imagery for brain-computer interfaces.

The opening of a communication channel between brain and computer [brain-computer interface (BCI)] is possible by using changes in electroencephalogram (EEG) power spectra related to the imagination of movements. In this paper, we present results obtained by recording EEG during an upper limb motor imagery task in a total of 18 subjects by using low-resolution surface Laplacian, different linear and quadratic classifiers, as well as a variable number of scalp electrodes, from 2 to 26. The results (variable correct classification rate of mental imagery between 75% and 95%) suggest that it is possible to recognize quite reliably ongoing mental movement imagery for BCI applications.

Algorithms↗