Antegrade access in a stented common femoral artery: feasible but with a real bleeding risk.

Antegrade femoral artery access is often used for diagnostic and interventional purposes in patients with critical limb ischemia, given its potential advantages in terms of visualization and back-up. However, it may be associated with an increased risk of local vascular complications, especially in the presence of common femoral artery atherosclerosis. We hereby report a case of antegrade femoral access in a previously stented common artery, which enabled successful recanalization of a totally occluded superficial femoral artery. Despite the procedural success, retroperitoneal bleeding occurred after sheath removal, which was nonetheless effectively managed with prolonged balloon inflations by means of contralateral femoral artery access. This clinical vignette, the first to date to report on antegrade access in a stented femoral artery, supports its feasibility despite the presence of a real bleeding risk.

Aged↗

Angioseal use after antegrade femoral arteriotomy in patients undergoing percutaneous revascularization for critical limb ischemia: a case series.

Antegrade femoral artery access is commonly used for percutaneous transluminal revascularization of ipsilateral lower limbs in patients with critical limb ischemia. While hemostasis at the end of the procedure can be achieved by manual compression, this may lead to an increase in local vascular complications. Femoral artery closure devices, such as the Angioseal collagen plug and anchor device, have been approved and shown of benefit after retrograde femoral artery catheterization. To date, there are however no data on the use of such arteriotomy closure device after antegrade femoral access. We hereby report a case series of five patients in whom Angioseal was successfully used after antegrade femoral puncture and below-the-knee percutaneous transluminal angioplasty. In all cases the device enabled immediate and complete hemostasis without major complications, despite the intense antithrombotic regimen, including heparin, aspirin, and clopidogrel in all patients, as well as glycoprotein IIb/IIIa inhibitors (in two patients) and fibrinolytic therapy (in one).

Aged↗

Combined surgical and endovascular treatment of aortic arch aneurysms.

BACKGROUND: Traditional repair of aortic arch aneurysms requires cardiopulmonary bypass, hypothermia, and circulatory arrest and is associated with considerable morbidity and mortality. Endovascular stent-graft placement has developed as a safe and effective treatment for various diseases of the descending aorta and, recently, even in delicate anatomic regions such as the aortic arch. The aim of this study is to review our clinical experience with endovascular treatment of aortic arch aneurysms after surgical transposition of supra-aortic vessels. METHODS: Fifteen patients received thoracic stent-graft implants after aortic debranching for repair of aortic arch aneurysms during the 3-year period ending December 31, 2005. All patients were not candidates for standard endovascular repair due to inadequate proximal landing zones on the aortic arch. Device design and implant strategy were determined by an evaluation of aortic morphology with angiography and computed tomography (CT) scanning. Stent-grafts were used to repair the arch after supra-aortic vessel transposition was performed. The endografts were implanted transfemorally or via an iliac Dacron conduit graft using standardized endovascular techniques. Follow-up was 100% complete (mean, 18 +/- 2.5 months; range, 12 to 36 months). Outcome variables included death and treatment failure (endoleak, aortic rupture, reintervention, or aortic-related or sudden death). Follow-up included clinical examination, chest radiograph, and CT at discharge, 6 months after stent-graft placement, and yearly thereafter. RESULTS: Stent-graft deployment success was 100% after staged supra-aortic vessel transposition. Patency of all endografts and conventional bypasses was 100%. No endoleak or graft migration was observed. There were no neurologic complications. One patient died 2 months after the procedure from pulmonary complications. CONCLUSION: Repair of aortic arch aneurysms by sequential transposition of the supra-aortic branches and endovascular stent-graft placement is feasible. Extended application of this technique will enable safe and effective treatment of a highly selected subgroup of patients with aortic aneurysms by avoiding conventional arch aneurysm repair in deep hypothermia and circulatory arrest.

Adult↗

Rationale and design of a multidisciplinary national real-world registry on carotid stenting: the Italian Registry for Carotid Stenting (RISC).

The Registro Italiano per lo Stenting Carotideo (RISC, Italian Registry for Carotid Stenting) has been organized by Italian specialists from different disciplines directly involved in the prevention of stroke due to carotid plaques through stenting of carotid lesions. The Registry has been endorsed by the national societies of 4 different specialties: vascular surgery, interventional cardiology, radiology, and neuroradiology. Each society contributed in the planning stage. The basis for the registry is to collect data on carotid stenting procedures performed by different specialists with different techniques in a "real-world" setting without the limitations of a randomized clinical trial. The Registry was funded to enroll at least 1200 patients over a minimum period of 36 months. The results will be analyzed using the intention-to-treat principle and are anticipated in late 2006. Primary endpoints of the registry are the 30-day combined death and stroke rate and the occurrence of restenosis and ipsilateral neurological deficit at 12 and 24 months. Considerable attention has been paid to the registry's quality control program to ensure scientific validation. An online database facilitates the collection of data with speed and accuracy.

Carotid Stenosis↗

Bronchoesophageal fistula after endovascular repair of ruptured aneurysm of the descending thoracic aorta.

Aortoesophageal fistula secondary to thoracic aneurysm is rare and is usually fatal without prompt surgical intervention. A 79-year-old man with significant comorbidities and previous cancer surgery was admitted on an emergency basis because of the suspicion of a ruptured thoracic aortic aneurysm. Computed tomographic scan followed by angiography demonstrated a ruptured thoracic aneurysm with aortoesophageal fistula. An endovascular stent graft repair was performed with successful exclusion of both aneurysm and fistula. On postoperative day 6, dyspnea and an isolated episode of hemoptysis occurred. Endoscopy revealed the presence of a bronchoesophageal fistula, which necessitated double exclusion of the esophagus and feeding jejunostomy. At 6 months, clinical, bronchoscopic, and computed tomographic scan follow-up showed complete sealing of the aneurysm and resolution of the bronchoesophageal fistula. At 9 months, the patient was still alive but refused to undergo substernal gastric bypass in an attempt to restore oral feeding. Endovascular repair seems promising as an emergent and palliative treatment of aortoesophageal fistula. To the best of our knowledge, this is the first case in which a bronchoesophageal fistula developed after successful endovascular repair of aortoesophageal fistula. The pathogenesis of this complications remains unclear.

Aged↗

A variant deployment technique for the powerlink bifurcated endograft.

PURPOSE: To report an alternative technique to the dual-lumen catheter for deployment of the Powerlink stent-graft in patients with angulated sacs and calcified aortic bifurcations. A maneuver is also presented to retrieve the delivery system when it is snagged on the stent. TECHNIQUE: After cutdown of the right common femoral artery (CFA), a 9-F introducer sheath is placed percutaneously into the left CFA. A gooseneck catheter is introduced from the right CFA to capture a 0.035-inch hydrophilic guidewire inserted from the left. A 5-F straight catheter is passed over this guidewire from the left to the right CFA. In angulated aneurysm sacs, a 5-F Hunter catheter is introduced from the right femoral access to support a guidewire through the aneurysm to the suprarenal aorta. Then the guidewire is exchanged with a 0.035-inch Amplatz extra stiff wire, and the Hunter catheter is removed. In other cases, a 0.035-inch Amplatz extra stiff guidewire is placed up to the suprarenal aorta. The endograft delivery system is then deployed in the usual manner. A gooseneck snare is also useful in retrieving the delivery system when it is snagged on the stent at the endograft bifurcation. CONCLUSIONS: This variant technique facilitates the deployment of the Powerlink stent-graft when faced with angulated aneurysms or acute and calcified aortic bifurcations. A gooseneck catheter is helpful in retrieving the delivery system's "olive" after endograft placement.

Aortic Aneurysm, Abdominal↗

Open aortic surgical repair for left hemi-arch stent-graft failure.

A surgical technique of endovascular graft explant through an open aortic approach for left hemi-arch stent-graft failure is described. Between January and April 2003, we surgically treated 3 patients previously submitted for stent grafts for isthmic aortic diseases. Two patients had atherosclerotic aneurysm and 1 had a false lumen reperfusion of subacute intramural hematoma. At 6 to 8 months computed tomographic scan follow-ups on all patients showed a rapid enlargement of aortic diameters due to type I endoleaks. The presence of an uncovered proximal stent in the parasubclavian aorta did not allow a simple aortic cross clamping; therefore we performed an open aortic procedure through a left posterolateral thoracotomy, using femoro-femoral bypass and mild hypothermic circulatory arrest. Selective antegrade cerebral perfusion was started within 3 to 5 minutes from aortotomy and graft removal. Left hemi-arch and descending thoracic aortic replacement was then performed with continuous cerebral perfusion. No surgical mortality was observed. Postoperative course was uneventful for neurologic, cardiac, respiratory, and renal complications. The 3-month follow-ups were event free. This approach, associated with rapid stent-graft explant and selective cerebral antegrade perfusion, appears to be a safe and effective surgical strategy for treating this new aortic pathology.

Aged↗

Axillary artery access for interventional procedures.

PURPOSE: To evaluate axillary artery access for the interventional treatment of carotid or splanchnic arteries that have angulated takeoff or complex anatomy when larger catheters (up to 9 F) are needed. TECHNIQUE: The axillary artery approach was used to treat the left internal carotid artery (ICA) in 3 patients (2 angulated takeoffs and 1 bovine arch) and a celiac axis aneurysm. An 8-F, 45-cm-long introducer sheath was inserted for the carotid procedures, whereas a 9-F, 90-cm sheath was chosen for the celiac aneurysm. Cerebral protection and stenting were successfully performed in all carotid patients; an 8x40-mm stent-graft was implanted to exclude the celiac artery aneurysm. An 8-F vascular closure device was used in the axillary arteries; hemostasis was immediate, and no hematoma or other complications were recorded in follow-up. CONCLUSIONS: This preliminary experience revisits the axillary approach as an alternative access route for interventional procedures. In association with a vascular closure device, this approach should be considered as a useful and safe option for those interventional procedures in which larger sheaths or catheters are required to cope with difficult arterial anatomies.

Aneurysm↗

Randomized evaluation of polytetrafluoroethylene-covered stent in saphenous vein grafts: the Randomized Evaluation of polytetrafluoroethylene COVERed stent in Saphenous vein grafts (RECOVERS) Trial.

BACKGROUND: Treatment of lesions located in saphenous vein grafts (SVGs) is associated with increased procedural risk and a high rate of restenosis. METHODS AND RESULTS: We conducted a randomized, multicenter trial to evaluate the usefulness of a polytetrafluoroethylene (PTFE)-covered stent compared with a bare stainless steel (SS) stent for prevention of restenosis and major adverse cardiac events (MACE) in patients undergoing SVG treatment. The primary end point was angiographic restenosis at 6 months. Secondary end points were 30-day and 6-month MACE rates, defined as the cumulative of death, myocardial infarction (MI), and target lesion revascularization. Between September 1999 and January 2002, 301 patients with SVG lesions were randomized to either the PTFE-covered JoStent coronary stent graft (PTFE group, n=156) or the SS JoFlex stent (control group, n=145). Angiographic and procedural success rates were similar between the 2 groups (97.4% versus 97.9% and 87.3% versus 93.8%, respectively). The incidence of 30-day MACE was higher in the PTFE group (10.9% versus 4.1%, P=0.047) and was mainly attributed to MI (10.3% versus 3.4%, P=0.037). The primary end point, the restenosis rate at 6-month follow-up, was similar between the 2 groups (24.2% versus 24.8%, P=0.237). Although the 6-month non-Q-wave MI rate was higher in the PTFE group (12.8% versus 4.1%, P=0.013), the cumulative MACE rate was not different (23.1% versus 15.9%, P=0.153). CONCLUSIONS: The study did not demonstrate a difference in restenosis rate and 6-month clinical outcome between the PTFE-covered stent and the SS stent for treatment of SVG lesions. However, a higher incidence of nonfatal myocardial infarctions was found in patients treated with the PTFE-covered stent.

Adult↗

A randomized comparison of direct stenting versus stenting with predilatation in native coronary artery disease: results from the multicentric Crosscut study.

Stenting without predilatation has become possible due to the availability of a new generation of flexible, low-profile, securely crimped, balloon-expandable stents. This study compared the feasibility, efficacy and cost-effectiveness of direct stenting (DS) to the standard predilatation technique (PS) using the premounted Crossflex LC stent (Cordis Corporation, Miami Lakes, Florida). The study is a randomized prospective multicenter evaluation including 271 patients (140 patients in the DS group and 131 patients in the PS group) with 1 or 2 de novo or restenotic lesions located in native coronary arteries. Procedural success was 98.9% and 98.7% in the DS and PS groups, respectively (p = NS); crossover to PS was required in 22/166 lesions (13.2%) enrolled in the DS group because of inability to cross the target lesion without predilatation. Nonsignificant reductions in procedural time (-10.5%), fluoroscopy time (-4.7%) and amount of contrast (-3.8%) were observed in the DS group in comparison to the PS group. The number of balloons used (-76.6%) and the global cost of the procedure (-18.8%) were significantly lower in the DS group (p < 0.01 for both comparisons). After 6 months, no differences were observed in the restenosis rate between the two groups (22.0% for DS group versus 18.1% for PS group; p = NS) and in the incidence of major adverse clinical events (5.0% for DS group versus 3.0% for PS group; p = NS). Direct stenting is safe and feasible for the treatment of lesions in native coronary arteries and obtains a significant reduction in procedural cost, mainly due to the lower number of balloons used. Clinical and angiographic results at 6 months are comparable to those obtained after a conventional predilatation-stenting strategy.

Catheterization↗

Successful concomitant treatment of a coronary-to-pulmonary artery fistula and a left anterior descending artery stenosis using a single covered stent graft: a case report and literature review.

This report describes a case of a 47-year-old man who presented with early post-Q wave myocardial infarction angina and an atherosclerotic left anterior descending stenosis associated to a coronary-to-pulmonary artery fistula. Both coronary stenosis and fistula were successfully treated with a single polytetrafluoroethylene-covered stent graft implantation by intravascular ultrasound-guided procedure.

Angina Pectoris↗

Endovascular treatment of proximal bilateral iliac limb dislocation and kinking following endovascular abdominal aortic aneurysm repair.

We report the case of a 69-year-old man with a late type 1b endoleak due to proximal migration of both iliac limbs 5 years after endovascular repair of an abdominal aortic aneurysm. The endovascular method used to correct bilaterally this condition is described. Final angiographic control shows patency of the stent-graft without signs of endoleak.

Aged↗

Endovascular treatment of a renal artery branch aneurysm.

A 58-year-old woman was admitted to our institution because of a left renal artery branch saccular aneurysm with a 2 cm diameter. Due to a hostile abdomen and the infrarenal location, an endovascular approach was chosen. A Jostent Peripheral Stent-Graft was placed under angiographic control, excluding the aneurysm from the circulation. No peri- or postprocedural complications were observed. At 6 months follow-up, the endograft is patent, excluding the aneurysm. Endovascular treatment may represent an alternative to surgery, especially in the distal infraparenchymal location.

Aneurysm↗