PubMed Health⌕ Search

Biomedical subjects

Luigi P Badano

Publications and source records attributed to Luigi P Badano.

13 recordsLinked to original sources

Left ventricular electromechanical delay in patients with heart failure and normal QRS duration and in patients with right and left bundle branch block.

AIMS: We sought to define the reference values of intra-left ventricular (LV) electromechanical delay (EMD), and to assess the prevalence (and pattern) of intra-LV dyssynchrony in patients with heart failure (HF) and normal QRS and in patients with right and left bundle branch block. METHODS AND RESULTS: We used tissue Doppler imaging echocardiography and a six-LV wall model to study LV EMD in 103 patients [41 with HF and normal QRS, 22 with right bundle branch block (RBBB), and 40 with left bundle branch block (LBBB)], and in 59 controls. In controls, the median intra-LV EMD was 17 ms, (inter-quartile range 13-30); 95% of controls had a value < or =41 ms. Patients showed a longer intra-LV EMD than controls: 33 ms (20-57) in patients with normal QRS, 32 ms (23-50) in RBBB patients, and 50 ms (30-94) in LBBB patients. Intra-LV dyssynchrony (defined as intra-LV EMD >41 ms) was present in 39, 36, and 60% of the patients, respectively. On average, HF patients showed the same pattern of activation as controls, from the septum to the posterior wall, but activation times were significantly prolonged. In RBBB patients the activation sequence was directed from inferior to anterior and in LBBB from anterior to inferior wall. CONCLUSIONS: Left ventricular dyssynchrony was present in several patients with HF and normal QRS, and in patients with RBBB; conversely, 40% of LBBB patients showed values of LV EMD within the normal range. Left ventricular activation sequence was different between groups. Assessment of LV synchronicity by means of imaging techniques may be more important than QRS duration or morphology in selecting patients for cardiac resynchronization treatment.

Aged↗

Results of aortic valve replacement with a new supra-annular pericardial stented bioprosthesis.

BACKGROUND: The stented Soprano valve (Sorin Biomedica S.pA., Saluggia, Italy) is a pericardial tissue valve designed for a totally supra-annular implant with the aim of improving hemodynamic performance, particularly in patients with a reduced aortic annulus. However, its hemodynamics and early clinical outcome are poorly understood. METHODS: Seventy-seven patients (mean age 76 +/- 5 years, 56% males) underwent aortic valve replacement with the Soprano valve. All patients were monitored with clinical examination and serial echocardiography at 1, 6, and 12 months and yearly afterward. RESULTS: At preoperative echocardiography, average left ventricular outflow tract diameter was 2.1 +/- 0.2 cm. At operation, 35% of patients received a 20-mm valve, 54% a 22-mm valve, and 11% a 24-mm valve. At 6-month follow-up, peak and mean transprosthetic gradients were 18 +/- 8 and 9 +/- 4 mm Hg, respectively; effective orifice area (EOA) and EOA index were 1.84 +/- 0.6 cm2 and 0.9 +/- 0.2 cm2/m2, respectively. Incidence of patient-prosthesis mismatch (ie, EOA index < 0.85 cm2/m2) was 23%, with no case of severe mismatch (ie, EOA index < 0.6 cm2/m2). In addition, left ventricular hypertrophy showed a significant regression (mass index from 214 +/- 98 g to 129 +/- 41 g; p = 0.001), and ejection fraction increased (from 58% +/- 17% to 67% +/- 8%; p = 0.001). Cumulative follow-up was 7.9 months per patient. Thirty-day mortality rate was 2.6% (2 of 77). Cumulative survival at 6, 12, and 24 months was 92% +/- 3.7%, 85% +/- 5.7%, and 85% +/- 5.7%, respectively. Two patients experienced embolic episodes. One case of anticoagulant-related bleeding occurred. CONCLUSIONS: In our series, the Soprano bioprosthesis showed a good hemodynamic performance, low incidence of patient-prosthesis mismatch, and favorable early clinical results.

Aged↗

Heart failure and severe pulmonary hypertension caused by distal detachment of the valve conduit 16 years after the Cabrol composite graft procedure.

We report the case of a patient who underwent Cabrol composite graft procedure for ascending aorta aneurysm and aortic regurgitation. Sixteen years later he developed progressive dyspnea and a left-to-right shunt caused by distal detachment of the valve conduit with persistence of the perigraft space-right atrial fistula visualized with echocardiography. Our case shows that late manifestations of surgical complications of the Cabrol procedure may occur and transesophageal echocardiography may allow a comprehensive assessment in these patients. However, because surgical management of ascending aorta aneurysms has changed in the last decades a detailed knowledge of the surgical technique used is mandatory for adequate interpretation of transesophageal echocardiographic results.

Aged↗

Additive value of contrast echocardiography for the diagnosis of noncompaction of the left ventricular myocardium.

Noncompaction of the left ventricular myocardium is a rare and unclassified cardiomyopathy that remains frequently overlooked, even by experienced echocardiographers. This fact may be due to non-optimal imaging of the lateral and apical myocardium, and/or insufficient disease awareness by echocardiographers. We report a case of a young man with heart failure and severe left ventricular dysfunction, previously diagnosed of ischemic etiology, in which the contrast enhancement of left ventricular endocardium allowed us to reach the correct diagnosis of isolated left ventricular noncompaction.

Echocardiography↗

Estimation of infarct size by single measurements of creatine kinase levels in patients with a first myocardial infarction.

OBJECTIVE: Enzymatic estimation of infarct size is desirable in the reperfusion era, because a possible discrepancy with the observed asynergic area of the left ventricle may suggest the presence of stunned myocardium. Unfortunately, timely myocardial reperfusion produces a rapid washout of creatine kinase (CK) in blood flow, which overestimates infarct size. In this perspective, we investigated whether the mid-terminal portion of the CK time-activity curve could predict infarct size more reliably. METHODS: Enzymatic infarct size was calculated by peak CK levels, the CK area under the curve and by single CK values, in 103 patients with a first ST-elevation myocardial infarction, and compared to the left ventricular akinetic area. The wall motion asynergy score at follow-up was considered as the actual infarct size. RESULTS: In patients with peak CK within 10 h of symptom onset, CK levels at 30 h showed a high independent correlation (r = 0.83; P < 0.001) with infarct size. In patients with late peak CK (> 10 h), CK levels at 12 h turned out to be the best predictor of infarct size (r = 0.55; P < 0.01). At multivariate regression analysis, peak CK was the best predictor of infarct size in the whole population (r = 0.61; P < 0.001). CONCLUSIONS: In patients with ST-elevation myocardial infarction and early peak CK, infarct size at follow-up could be better estimated with single values of the mid-terminal portion of the CK time-activity curve.

Aged↗

Clinical and hemodynamic implications of supra-annular implant of biological aortic valves.

The use of stented bioprostheses in elderly patients with degenerative aortic stenosis, despite being desirable, raises concerns about the harmful effects of residual obstruction to left ventricular outflow. To overcome this limitation new stented and stentless bioprostheses have been designed for supra-annular implant. However, the actual hemodynamic advantage of supra-annular implant over the intra-annular one remains incompletely understood. This review focuses on the geometry of biological valve prostheses designed for supra-annular implant and its implications for the echocardiographic assessment of valve hemodynamics. Available data about the hemodynamic performance of these valves implanted in the supra-annular position in comparison with the usual intra-annular implant are also reviewed. Other issues related to biological heart valve performance, such as biomaterials, tissue mechanics, durability, and clinical outcome are not addressed in this review.

Aorta↗

Stented bioprosthetic valve hemodynamics: is the supra-annular implant better than the intra-annular?

BACKGROUND AND AIM OF THE STUDY: The use of stented bioprostheses for aortic valve replacement (AVR) in elderly patients with a small aortic annulus may result in unsatisfactory hemodynamic performance of the prosthesis. To overcome this limitation, new bioprostheses have been designed for complete supra-annular implantation, but the actual hemodynamic advantage of the supra-annular implant over the intra-annular has not been fully investigated. Accordingly, the hemodynamic performance of the same stented bioprosthesis (except for sewing ring design) implanted in the supra-annular and conventional intra-annular seating was compared. METHODS: Twenty-two patients received an intra-annular implant, and 38 a supra-annular implant. Age (74 +/- 5 versus 76 +/- 5 years, p = 0.54), gender (55% versus 50% males, p = 0.79) and body surface area (1.74 +/- 0.2 versus 1.81 +/- 0.2 m2, p = 0.13) were similar in both subgroups, who underwent echocardiography at 8 +/- 2 and 6 +/- 2 months after surgery, respectively (p = 0.09). RESULTS: The two patient subgroups had similar preoperative left ventricular outflow tract diameters (2.06 +/- 0.2 and 2.1 +/- 0.2 cm; p = 0.62), average size of implanted prosthesis (21.0 and 21.3 mm; p = 0.44) and mean transprosthetic flow rate (246 +/- 70 and 218 +/- 58 ml/s; p = 0.12). Mean (8 +/- 3 and 19 +/- 8 mmHg, p < 0.0001), and peak (17 +/- 6 and 40 +/- 13 mmHg; p < 0.0001) transprosthetic gradients were lower, and mean effective orifice area (EOA) (1.78 +/- 0.4 and 1.45 +/- 0.5 cm2, p = 0.006) was higher in patients with supra-annular implants than in those with intraannular. The incidence of patient-prosthesis mismatch (EOA index < 0.85 cm2/m2) decreased from 50% to 34% (p < 0.0001), with no case of severe mismatch using the supra-annular implant. During follow up, a left ventricular mass reduction occurred in patients with supra-annular implants (from 225 +/- 110 to 173 +/- 59 g/m2; p < 0.03), but not in patients with intra-annular implants (173 +/- 62 and 186 +/- 64 g/m2; p = 0.87) CONCLUSION: The study results showed that, compared to intra-annular implantation, supra-annular implantation of bioprosthetic stented valves in the aortic position was associated with a significantly better hemodynamic performance of the prosthesis and significant regression of left ventricular hypertrophy.

Aged↗

[Selection of patients undergoing cardiac resynchronization therapy: role of echocardiography].

Patients with heart failure, marked systolic dysfunction and dys-synchronous myocardial contraction are at increased risk for exacerbated pump failure and arrhythmias, and suffer higher mortality rates. In these patients, cardiac resynchronization therapy (CRT), achieved by a biventricular pacing, can lead to clinical improvement, reverse left ventricular remodeling and prolonged survival, although a substantial subset of non-responders has been reported. The electrocardiographic QRS width does not predict long-term CRT benefit, while direct measures of mechanical dyssynchrony obtained by various ultrasound techniques have been shown to have a better predictive value. However, currently there is no consensus on the optimal ultrasound technique to use for assessing mechanical dyssynchrony and select candidates for CRT. In this review, the clinical role of both conventional and new ultrasound techniques applied to the study of cardiac dyssynchrony will be discussed, focusing on patient selection for CRT.

Cardiac Pacing, Artificial↗

Patients with chronic heart failure encountered in daily clinical practice are different from the "typical" patient enrolled in therapeutic trials.

BACKGROUND: The aim of this study was to compare the clinical characteristics of patients enrolled in randomized clinical trials on congestive heart failure treatment with those of real-world patients encountered in daily clinical practice. METHODS: We searched the Cochrane review methodology, Medline and SilverPlatter databases to obtain the clinical characteristics of both patients enrolled in therapeutic clinical trials and real-world patients with heart failure. We selected 27 clinical trials, and 8 prospective epidemiological studies or registries published between 1987 and 2001 which enrolled 53,859 and 18,207 patients, respectively. RESULTS: On average, compared to real-world heart failure patients, patients enrolled in clinical trials were younger (63 +/- 10 vs 75 +/- 11 years respectively, p < 0.0001), and more likely to be male (72 vs 54% respectively, p < 0.0001). Clinical trial patients showed a lower ejection fraction (26 +/- 7 vs 38 +/- 15% respectively, p < 0.0001) but a lower prevalence of NYHA functional class III-IV (62 vs 75% respectively, p < 0.0001) than real-world patients. In clinical trial patients, the prevalence of ischemic heart disease (67 vs 42% respectively, p < 0.0001) and a history of previous myocardial infarction (62 vs 42% respectively, p < 0.0001) were higher than in real-world patients. Conversely, the prevalence of chronic atrial fibrillation (12 vs 31% respectively, p < 0.0001) and of diabetes (22 vs 24% respectively, p < 0.02) was lower in trial patients than in real-world patients. CONCLUSIONS: Our data suggest that most clinical trials on congestive heart failure, on which the guidelines for clinical practice are based, have generally included patients who are not representative of the whole spectrum of patients actually managed in clinical practice.

Adult↗

Prevalence, clinical characteristics, resource utilization and outcome of patients with acute chest pain in the emergency department. A multicenter, prospective, observational study in north-eastern Italy.

BACKGROUND: The evaluation and triage of patients with suspected myocardial ischemia in the emergency department is challenging and costly. In Italy there are no prospective data neither about the prevalence, clinical characteristics, and outcome of patients with chest pain in the emergency room, nor about the costs of their triage. Therefore, this study was undertaken to evaluate the diagnostic accuracy and costs of the actual emergency department triage modalities of patients with acute chest pain. METHODS: We analyzed the clinical data from a multicenter, prospective study of all patients with chest pain who presented to the emergency department of three hospitals in North-Eastern Italy from April to October 1999. RESULTS: Of 12,375 new medical admissions at the three emergency departments during the study period, 495 (prevalence 4%, mean age 62 +/- 16 years, 50% females) were for chest pain. Thirty-seven percent of the patients with chest pain were hospitalized with a suspected acute coronary syndrome, while 63% were directly discharged from the emergency department. The diagnosis of acute coronary syndrome was confirmed in 79% of hospitalized patients. Among the patients discharged directly from the emergency department 68% were immediately sent back home (69 +/- 60 min from admission) and 32% required a brief clinical observation lasting 10 +/- 6 hours and including serial electrocardiographic and myocardial injury marker assessment. The average cost of the emergency department triage was 189 +/- 237 [symbol: see text]/patient. The 1-month follow-up of the patients directly discharged from the emergency department revealed a 2.5% incidence of acute coronary syndromes (3 acute myocardial infarctions), but no deaths. CONCLUSIONS: Data obtained from our multicenter observational study suggest that present triage modalities for patients with chest pain in the emergency department based on patient history, clinical data, electrocardiography, and myocardial injury marker assessment could be improved in terms of accuracy and efficacy. Our data provide the clinical and economical framework for the designation of trials of new accelerated critical pathways for chest pain evaluation in the emergency department.

Acute Disease↗

[Portable ultrasound devices. A new era for clinical cardiologists].

Recent advances in ultrasound technology have led to the development of fully portable ultrasound machines for point-of-care cardiac examination. Limited comparative studies indicate that these devices are more accurate than physical examination in identifying cardiac abnormalities. Though their diagnostic performance is generally inferior to standard echocardiography, there appears to be good concordance at least for some conditions. However, it must be emphasized that reported results were obtained with cardiologists or sonographers trained and experienced in performing and interpreting echocardiography. The potential role of these devices in cardiac care will depend on their impact on patient management, compatibility with individual practice, their cost, and further technical developments. Operator training in performance and interpretation of examinations obtained using these ultrasound devices seems to be vitally important.

Ambulatory Care↗