Ventricular pacing lead location alters systemic hemodynamics and left ventricular function in patients with and without reduced ejection fraction.

OBJECTIVES: We compared left ventricular (LV) systolic and diastolic function during right ventricular (RV), LV, and biventricular (BiV) pacing in patients with narrow QRS duration with and without LV dysfunction. BACKGROUND: The optimal RV pacing lead location for patients with a standard indication for ventricular pacing remains controversial. METHODS: Left ventricular pressure and volume data were determined via conductance catheter during electrophysiology study in 31 patients divided into groups with ejection fraction (EF) > or =40% (n = 17) or EF <40% (n = 14). QRS duration was 91 +/- 18 versus 106 +/- 25 ms, respectively (p = NS). Hemodynamic data were recorded during atrial and dual chamber pacing from the RV apex, RV free wall, RV septum, LV free wall, and BiV. RESULTS: In patients with EF > or =40%, RV pacing at 1 or more sites, but not LV free wall or BiV pacing, significantly (p < 0.05) impaired cardiac output (CO), stroke work (SW), EF, and LV relaxation compared with atrial overdrive pacing. Right ventricular pacing also impaired hemodynamics and LV function in patients with EF <40%. However, LV and BiV pacing increased CO, SW, EF, and LV +dP/dt(MAX) in patients with LV dysfunction. Left ventricular and BiV pacing enhanced an index of global LV cycle efficiency in patients with depressed EF. The detrimental hemodynamic effects of RV pacing were attenuated by selecting the optimal RV pacing site. CONCLUSIONS: Right ventricular pacing worsens LV function in patients with and without LV dysfunction unless the RV pacing site is optimized. Left ventricular and BiV pacing preserve LV function in patients with EF >40% and improve function in patients with EF <40% despite no clinical indication for BiV pacing.

Arrhythmias, Cardiac↗

Utility of a new left ventricular asynchrony index as a predictor of reverse remodelling after cardiac resynchronization therapy.

AIMS: The majority of tissue Doppler indexes proposed to predict left ventricular (LV) reverse remodelling in cardiac resynchronization therapy (CRT) reflects LV asynchrony as assessed in ejection phase. We evaluated the predictive value of a new strain-imaging parameter reflecting the total amount of time spent by 12 LV segments in contracting after aortic valve closure. METHODS AND RESULTS: Fifty-nine patients who fulfilled current treatment recommendations were studied before and 6 months after CRT. Time to tissue Doppler systolic peak velocity (Ts) and time exceeding aortic closure (ExcT) in strain curves were measured in 12 LV segments. Ts standard deviation (Ts-SD) and sum of ExcT of overall 12 LV segments (oExcT) were analysed. After 6 months, responders were defined according to > or =15% LV end-systolic volume reduction. Responders (47%) when compared with non-responders (53%) had significantly higher baseline Ts-SD and oExcT values. Receiver operating characteristic (ROC) curve analysis demonstrated that an optimal cutoff value of 760 ms for oExcT yielded 93.5% sensitivity and 82.8% specificity. For Ts-SD at the cutoff of 32 ms, 82% sensitivity and 39% specificity were obtained. Area under ROC was significantly larger for oExcT than for Ts-SD. CONCLUSION: o-ExcT is able to predict LV reverse remodelling after CRT.

Aged↗

Determinants of thoracic electrical impedance in external electrical cardioversion of atrial fibrillation.

The success of external cardioversion (ECV) of atrial fibrillation depends on generating sufficient transmyocardial current for defibrillation with minimal myocardial injury. Thoracic electrical impedance plays an important role in the relation between the delivered energy and transmyocardial current. This study assessed the determinants of thoracic electrical impedance in ECV of atrial fibrillation. ECV of atrial fibrillation was performed in 80 consecutive patients (mean age 73 +/- 9 years; men 69%; body mass index 26.0 +/- 3.6 kg/m(2)) within 12 months, using biphasic shocks (Multipulse Biowave) delivered through adhesive pads in an anteroposterior position. Thoracic electrical impedance was measured using the first shock. The mean thoracic electrical impedance was 57.7 +/- 12.3 Omega (energy 71 +/- 43 J, current intensity 33 +/- 12 A). Sinus rhythm was immediately restored in 75 patients (94%). Thoracic electrical impedance was greater (60.9 +/- 11.8 vs 51.7 +/- 11.0 Omega, p = 0.001) in patients requiring >1 shock (65%). At multivariate linear regression analysis (R = 0.761, p <0.001), female gender (+9.7 +/- 2.0 Omega, p <0.001), body mass index (+1.5 +/- 0.3 for a 1 kg/m(2) increase, p <0.001), hemoglobin concentration (+1.9 +/- 0.6 for a 1 g/dl increase, p = 0.004), and the presence of chronic heart failure (-5.3 +/- 2.0 Omega, p = 0.009) were independent predictors of thoracic electrical impedance. In conclusion, to increase ECV efficacy and minimize complications, the delivered energy should be adjusted in accordance with the clinical variables that independently affect thoracic electrical impedance and, hence, transmyocardial current.

Aged↗

Role of ventricular Autocapture function in increasing longevity of DDDR pacemakers: a prospective study.

AIMS: Autocapture is an algorithm for automatic adaptation of ventricular output to capture threshold. The aim of this prospective study was to estimate the effects of ventricular Autocapture algorithm on DDD-DDDR pacemaker longevity. METHODS AND RESULTS: Eighty-three patients implanted with a DDD-DDDR pacemaker (Affinity or Entity; St Jude Medical, USA) were enrolled and the Autocapture function was activated pre-discharge. Ventricular pulse duration was randomly programmed at 0.3 or 0.4 ms, with a cross-over at 8-12 weeks and again at 13-14 months. Diagnostic data were retrieved from device memory and by calculating battery current drain from long-term threshold recordings; device longevity was estimated at the following settings: Autocapture with a pulse duration of 0.3 and 0.4 ms, respectively, standard output (3.5 V, 0.4 ms) and conventional low output programming (2.5 V, 0.4 ms). According to a series of assumptions, Autocapture was associated with a 55-60% increase in estimated device longevity compared with standard output programming and a 6-7% increase in longevity compared with low output programming. No significant differences were found between Autocapture programmed with a pulse duration of 0.3 or 0.4 ms. In projections to a 10-year follow-up, use of the Autocapture function resulted in a 42% reduction in pacing-related estimated costs compared with standard output programming at 3.5 V, 0.4 ms. CONCLUSION: Pacing with constant adaptation of ventricular output in dual-chamber devices has the potential to increase generator longevity and to reduce sizeably pacing-related costs compared with standard programming.

Adult↗

Trans-septal catheterization in the electrophysiology laboratory: data from a multicenter survey spanning 12 years.

OBJECTIVES: We report the data from the Italian Survey on trans-septal catheterization (TSP-C) for catheter ablation of arrhythmias in the left heart that covered 2003 and previous years. BACKGROUND: Over the last decade the use of TSP-C in the electrophysiology laboratory has greatly increased. Recent data on number of procedures, accomplishment rate, and complications related to this procedure are lacking in a large cohort of patients. METHODS: Thirty-three centers participated in the survey. The data collected retrospectively for 2003 included the number of procedures, indications, methods, and the number and reason for unaccomplished cases along with complications. Retrospective data collected for previous years included the annual number of procedures and cumulative data concerning indications, accomplishments, and complications. RESULTS: Since 1992, 5,520 TSP-C procedures were used in arrhythmia ablation, with the peak increase in the use occurring in 2001. Trans-septal catheterization was performed for atrial fibrillation (AF) ablation in 78.3% of the procedures in 2003. The electrophysiologist independently performed the procedure in 29 of 33 centers. Trans-septal catheterization was successfully performed in 99.1% of the cases; the main reason for TSP-C not being performed was related to fossa ovalis/atrial septum anatomy. Complications were low both in 2003 and in the previous years (0.79% and 0.74%, respectively). CONCLUSIONS: Trans-septal catheterization in the electrophysiology laboratory is associated with a high success and low complication rate. The use of TSP-C has progressively increased over the last decade and is currently used primarily for AF ablation. Although possible, severe complications were rare.

Arrhythmias, Cardiac↗

Characteristics of ventricular tachyarrhythmias occurring in ischemic versus nonischemic patients implanted with a biventricular cardioverter-defibrillator for primary or secondary prevention of sudden death.

OBJECTIVES: The InSync ICD Registry evaluated patients indicated for cardiac resynchronization therapy with defibrillation. BACKGROUND: Cardiac resynchronization therapy with defibrillation systems are prescribed for both primary and secondary prevention of sudden cardiac death in patients with heart failure with both ischemic and nonischemic etiology. The characterization of ventricular tachyarrhythmias detected by the ICD is not well known in these subpopulations. METHODS: We enrolled 421 patients with symptomatic heart failure despite optimized medical treatment, ventricular dyssynchrony, and primary or secondary ICD indications. An electrophysiologist reviewed all spontaneous episodes. Patients were grouped by etiology and ICD indications. RESULTS: The 421 patients included 292 ischemic (159 primary prevention) and 129 nonischemic (68 primary prevention) patients. In 19 +/- 11 months of follow-up, 110 patients (63 ischemic, 30 primary prevention and 47 nonischemic, 21 primary prevention) presented ventricular tachyarrhythmias, occurring in a ventricular tachycardia (VT) or a ventricular fibrillation zone (1382 and 456 events, respectively). The incidence of overall ventricular tachyarrhythmias in nonischemic patients in secondary prevention (35.7% at 1 year) was higher than in ischemic patients implanted for either indication (16.5% and 22.9% at 1 year, respectively). The incidence of self-terminating ventricular tachyarrhythmias was greater in patients with nonischemic heart disease, regardless of indication. Patients with ischemic heart disease in primary prevention had a lower occurrence of VTs, whereas nonischemic patients in primary prevention had faster VTs. CONCLUSIONS: Both rate of occurrence and characteristics of detected ventricular tachyarrhythmias vary according to underlying etiology and indication. Therefore, different device programming according to patient's profile is advisable to improve ventricular tachyarrhythmias management.

Adult↗

Temporal variation in optimal atrioventricular and interventricular delay during cardiac resynchronization therapy.

BACKGROUND: Tailored atrioventricular delay (AVd) and interventricular delay (VVd) combination improves hemodynamics in patients treated with cardiac resynchronization therapy (CRT). Whether tailored AVd-VVd combination changes over time is not known. METHODS AND RESULTS: Twenty-two patients (18 M, aged 69.9 +/- 12.5 years, New York Heart Association class III, QRS > or = 130 ms, ejection fraction 29.6 +/- 8.8%) were implanted with a biventricular device with programmable VVd. Myocardial performance index (MPI) was evaluated during pacing at different VVds and AVds at baseline and after 6 and 12 months. The optimal AVd-VVd combination was identified by the minimum MPI. After optimization, the appropriate AVd-VVd combination was programmed in each patient. MPI at 6-month follow-up after optimization was significantly higher compared with baseline (.79 +/- .21 vs. .59 +/- .15, P < .05). Re-optimization of AVd-VVd combination was required after 6 months in 21 of 22 (95%) patients. Re-optimization significantly reduced MPI compared with the value prior to re-optimization (.56 +/- .15 vs. .79 +/- .21, P < .05). The MPI remained unchanged at 12-month compared with 6-month follow-up (.59 +/- .19 vs. .56 +/-.15, P = NS). Clinical symptoms and reverse left ventricular remodeling were sustained at 6-month and 12-month follow-up. CONCLUSION: Optimal AVd and VVd combination changes over time in patients with heart failure. Sustained improvement in clinical symptoms and reverse left ventricular remodeling after CRT are not temporally associated with improvement in MPI.

Aged↗

Effects of cardiac resynchronization therapy on the mechanisms underlying functional mitral regurgitation in congestive heart failure.

AIMS: Functional mitral regurgitation (FMR) improvement induced by cardiac resynchronization therapy (CRT) has been related to left ventricular (LV) remodeling reversal and contractility enhancement. The effects induced by the changes of LV synchronicity indexes on FMR severity have not been investigated. METHODS AND RESULTS: In 30 patients with CRT for heart failure (HF) and QRS>130 ms, LV function parameters, FMR severity as mitral jet regurgitation/left atrial area ratio (JA/LAA) and standard deviation (SD) of the time to the systolic peak velocity at 6-basal and mid-LV segments as asynchrony indexes were evaluated (echo/tissue Doppler) before and 6 months after implant. At follow-up, 15 patients resulted responders to LV reverse remodeling with > or =15% end-systolic volume (ESV) and LV systolic function improvement. Improvement of FMR with > or =15% JA/LAA reduction was observed in 19 patients, 7 were nonresponders to LV reverse remodeling. In patients with > or =15% JA/LAA reduction a significant decrease of LV asynchrony indexes was observed as compared to patients without > or =15% JA/LAA reduction in whom LV asynchrony indexes were increased. Reduction of LV mid-segmental asynchrony was the variable most strongly related to JA/LAA reduction (r(2)=0.697, P<0.01), with good agreement between observed and predicted values (only 1 patient outside the mean+/-2SD). CONCLUSION: These data reveal that CRT can reduce FMR irrespective to LV remodeling reversal; this effect is related to LV asynchrony reduction and further support CRT employment in patients with HF and FMR.

Aged↗

Is a dual-sensor pacemaker appropriate in patients with sino-atrial disease? Results from the DUSISLOG study.

BACKGROUND: Rate-responsive pacemakers (PMs) are often supplied with accelerometer (XL) and minute ventilation (MV) sensors to provide a physiologic rate response according to patient needs. No information is available about the real benefit of dual-sensor rate-responsive pacing on the daily life of patients. METHODS: DUSISLOG (Dual Sensor vs Single Sensor comparison using patient activity LOGbook) is a two-arm prospective, randomized, multicenter study that enrolled 105 patients who received a rate-responsive PM (Insignia), Guidant Corp.). After 1 month of DDD pacing at 60 ppm lower rate, a single sensor (XL or MV, randomized) was activated for 3 months at the manufacturer's suggested nominal settings, followed by a 3-month period with dual sensors optimized with automatic response. During the last month of each period, the following data concerning patient physical activity were retrieved from PM diagnostics (Activity Log): mean percentage of physical activity, mean intensity of activity. Quality of life (QoL) scores and 6-minute walk test (WT) were also recorded. RESULTS: Single-sensor rate-responsive pacing resulted in symptomatic benefit equally with XL and MV sensors while no additional benefit was found using dual sensor. In a subgroup analysis, patients (17%) with marked chronotropic incompetence and with 0% atrial sensing received benefits from single sensor with an additional advantage from sensor (QoL: +21 +/- 14% P < 0.05; WT: +17 +/- 7% P < 0.02). CONCLUSION: In most patients with rate-responsive devices, a single sensor is sufficient to achieve a satisfactory rate response. A dual sensor combination and optimization provides an additional benefit only in a selected population with an advanced atrial chronotropic disease.

Aged↗

The risk profile for obstructive sleep apnea does not affect the recurrence of atrial fibrillation.

BACKGROUND: Obstructive sleep apnea (OSA) has been linked to increased prevalence and recurrence of atrial fibrillation (AF). We hypothesized that OSA may aggravate AF in patients with pacemakers implanted for sinus bradycardia who had documented paroxysmal AF. METHODS: Seventy-two patients (36 M, aged 77 +/- 6 years) completed the study. All patients received a dual-chamber pacemaker equipped with diagnostic and preventive functions for AF. OSA was diagnosed with the Berlin Questionnaire, which is validated to identify patients with OSA. Four-month continuous pacemaker recordings were collected for all patients. RESULTS: OSA was diagnosed in 28% of patients. Patients at high risk for OSA (HR group) and patients at low risk for OSA (LR group) were equivalent for gender, age, and body mass index. The rate of hypertension was higher in HR than in LR group (90% vs 44%, P < 0.01). The prevalence of paroxysmal AF during the study period was similar in HR and LR group (53% vs 44%, P = NS). Overall number of AF episodes per month was not significantly different between HR and LR group (7 +/- 13 vs 36 +/- 122, P = NS). Similarly, AF burden (AF%) was not significantly different between HR and LR group (0.3 +/- 0.6 vs 2.0 +/- 4.8, P = NS). Circadian distribution of AF episodes was similar in both groups. CONCLUSION: Long-term pacemaker recording of AF recurrence, AF burden, and its circadian distribution is similar in patients with paroxysmal AF at high risk for OSA and those at low risk for OSA.

Aged↗

Physiologic pacing: new modalities and pacing sites.

Right ventricular (RV) apical pacing impairs left ventricular function by inducing dys-synchronous contraction and relaxation. Chronic RV apical pacing is associated with an increased risk of atrial fibrillation, morbidity, and even mortality. These observations have raised questions regarding the appropriate pacing mode and site, leading to the introduction of algorithms and new pacing modes to reduce the ventricular pacing burden in dual chamber devices, and a shift of the pacing site away from the RV apex. However, further investigations are required to assess the long-term results of pacing from alternative sites in the right ventricle, because long-term results so far are equivocal. The potential benefit of prophylactic biventricular, mono-chamber left ventricular, and bifocal RV pacing should be explored in selected patients with a narrow QRS complex, especially those with impaired left ventricular function. His bundle pacing is a promising and evolving technique that requires improvements in lead technology.

Arrhythmias, Cardiac↗

Evolution and prognostic significance of diastolic filling pattern in cardiac resynchronization therapy.

BACKGROUND: Cardiac resynchronization therapy (CRT) is an emerging treatment for heart failure patients with left bundle branch block; in these patients left ventricle filling pattern (LVFP) abnormalities are recognized as cause of symptoms and predictors of outcome. We investigated the effects of CRT on diastolic function and the prognostic value of LVFP in patients on CRT. METHODS: 65 patients treated with CRT were studied over a 12 months period. At baseline, according to defined echocardiographic criteria, restrictive LVFP (RFP) was present in 25 patients, whereas 40 patients showed no-RFP. RESULTS: After CRT, opposite changes occurred in the two groups. In no-RFP patients, early-to-atrial filling velocity ratio (E/A) increased from 0.8+/-0.3 to 1.0+/-0.6 (p=0.006) and E wave deceleration time (DT) decreased from 234+/-83 ms to 196+/-51 ms (p=0.028). In 13 RFP patients, E/A decreased from 2.2+/-0.9 to 0.8+/-0.5 and DT increased from 128+/-43 ms to 205+/-52 ms (both p<0.001), leading to reversal of RFP. In both groups, clinical, functional and echographic benefits were evident, with mortality rates of 5% (2/40) and 15% (2/13) respectively. The remaining patients showed persistence of RFP (E/A and DT unchanged), no improvement and a mortality rate of 42% (5/12) (p=0.005, versus no-RFP). CONCLUSIONS: CRT improves diastolic function, inducing also reversal of LVFP in a consistent number of RFP patients. The persistence of RFP after CRT is associated to an extremely poor prognosis.

Aged↗

Monitored atrial fibrillation duration predicts arterial embolic events in patients suffering from bradycardia and atrial fibrillation implanted with antitachycardia pacemakers.

OBJECTIVES: The aim of our study was to evaluate arterial embolism (AE) occurrence rates and predictors in patients suffering from bradycardia and wearing a pacemaker with antitachycardia pacing therapies. BACKGROUND: Atrial fibrillation (AF) is associated with a high incidence of AE. METHODS: A total of 725 patients (360 men, age 71 +/- 11 years) were implanted with a DDDRP pacemaker (Medtronic AT500, Medtronic Inc., Minneapolis, Minnesota). At baseline 225 (31.0%) patients received antiplatelet therapy and 264 (36.4%) patients received anticoagulation agents. RESULTS: Over a median 22-month follow-up (25th to 75th interquartile range 16 to 30 months), AE occurred in 14 (1.9%) patients: 7 patients suffered a nonfatal ischemic stroke (0.6% per year), 4 patients had transient ischemic attack (0.34% per year), and 3 patients had embolic complications. Among baseline patients' characteristics, multivariate logistic analysis showed that embolic events are independently associated to ischemic heart disease (7.0 odds ratio [OR], 95% confidence interval [CI] 2.3 to 21.3, p = 0.001), prior embolic event (7.3 OR, 95% CI 1.2 to 43.9, p = 0.029), diabetes (5.0 OR, 95% CI 1.2 to 15.7, p = 0.032), and hypertension (4.1 OR, 95% CI 1.1 to 15.6, p = 0.036). The risk of embolism, adjusted for known risk factors, was 3.1 times increased (95% CI 1.1 to 10.5, p = 0.044) in patients with device-detected atrial fibrillation episodes longer than one day during follow-up. CONCLUSIONS: In a cohort of patients with bradycardia and AF, arterial embolism was common in patients with ischemic cardiopathy, hypertension, diabetes mellitus, and in patients with known stroke risk factors. Atrial fibrillation occurrences longer than one day were independently associated with embolic events.

Aged↗

Pacemaker selection: time for a rethinking of complex pacing systems?

Evidence from randomized trials indicates that the clinical benefits of dual-chamber (DDD) pacing are modest: (i) no significant differences exist between physiological pacing and single-chamber pacing in mortality and stroke; (ii) ventricular desynchronization resulting from chronic right-ventricular pacing in DDD mode, induces a significantly increased incidence of atrial fibrillation (AF) and heart failure hospitalizations; (iii) AF pacing prevention and therapy algorithms have shown a modest to minimal or absent efficacy; (iv) the widespread use of physiological pacemakers is not an economically attractive strategy. Thus, these data provide a reliable body of evidence on which to make more rationale clinical decisions for individual patients and policy decisions for health costs saving. The cheaper single-chamber AAI(R) or VVI(R) has been shown to satisfy both conditions in most cases of sinus node disease and AV block.

Atrial Fibrillation↗

Echocardiographic examination of atrioventricular and interventricular delay optimization in cardiac resynchronization therapy.

In 21 patients implanted with a biventricular pacing device with programmable interventricular delay (VVd), the myocardial performance index (MPI) was evaluated during spontaneous sinus rhythm, simultaneous biventricular pacing, and sequential biventricular pacing at different VVds and atrioventricular delays (AVds). The AVd-VVd combination associated with the minimum MPI defined patient-tailored biventricular pacing. Simultaneous biventricular pacing significantly improved MPI compared with spontaneous sinus rhythm. An additional improvement was obtained by tailored biventricular pacing. The optimal AVds were significantly shorter during right ventricular preactivation than during left ventricular preactivation.

Acute Disease↗

Digital technology for cardiac pacing.

Digital technology transforms analog signals into digital signals. Digitalization translates data into a numerical sequence of 0 seconds and 1 second or off and on (binary system). Thus encoded, differing signals (static or moving images, sounds, written texts) become homogeneous and can be handled simultaneously in a rapid and flexible manner while maintaining quality and stability. In digital format, data are easy to handle and can be compressed without undergoing any alteration of their contents, creating a vast wealth of information contained in little space, as in digital libraries.

Analog-Digital Conversion↗