Quantitative anatomical differences in central corneal thickness values determined with scanning-slit corneal topography and noncontact specular microscopy.

PURPOSE: This study was designed to analyze the differences in central corneal thickness values determined with noncontact specular microscopy and scanning-slit corneal topography. The measurements were performed on the same eye. METHODS: We analyzed the central corneal thickness values of 93 patients (n = 93) by means of noncontact specular microscopy (Topcon SP-2000P noncontact specular microscope, Topcon Corp., Tokyo, Japan) and scanning-slit corneal topography (Orbscan Topography System II, Orbscan Inc., Salt Lake City, UT). One experienced physician performed 3 consecutive central corneal thickness measurements with both devices. RESULTS: The central corneal thickness values obtained by means of Orbscan pachymetry were 17 +/- 2.7 (range, 12-24) microm greater. A significant correlation was observed between scanning-slit corneal topography and noncontact specular microscopy (Pearson correlation coefficient, r = 0.976; P < 0.001). CONCLUSIONS: Researchers should know of the existence of this difference between noncontact specular microscopy and Orbscan pachymetry when interpreting central corneal thickness values.

Adult↗

Caucasian emmetropic aged subjects have reduced corneal thickness values: emmetropia, CCT and age.

We aimed to analyze the possible changes in corneal thickness values according to age in emmetropic subjects. The central corneal thickness values of 100 emmetropic subjects (n = 100) were analyzed with the DGH 2000 AP ultrasonic pachymeter (DGH Technology, Inc., San Diego, CA, USA) by one experienced physician. The mean age of the subjects was 40.6 +/- 12.1 years old (range, 21-64). Analysis of the central corneal thickness (CCT) values by age subgroups indicated that subjects aged between 20 and 30 years had the higher CCT values. Differences in CCT values between the age groups were significant (p < 0.001; 1-way ANOVA test). A significant correlation between CCT values and age was found (r = -0.974; p < 0.001). In sum, it seems that there is a decrease in CCT values with age in emmetropic subjects.

Adult↗

Reduced corneal thickness values in postmenopausal women with dry eye.

PURPOSE: To study and compare the corneal thickness values of postmenopausal women with dry eye and postmenopausal women without dry eye. METHODS: The corneal thickness value of 30 postmenopausal women with dry eye (dry eye group; aged 52 to 55 years) and 32 postmenopausal women without dry eye (normal group; aged 51 to 55 years) was analyzed with the Orbscan Topography System II. Each woman underwent a tear breakup test, the Schirmer test, fluorescein staining of the cornea, and an analysis of the meibomian gland by slit lamp before corneal thickness measurement. The statistical analysis was performed by means of the unpaired Student t test. RESULTS: The mean corneal thickness value was significantly decreased in postmenopausal women with dry eye (P < 0.001 at each corneal location). The central cornea had the thinnest mean values in dry eyes and normal eyes (533.10 +/- 4.74 microm and 547.63 +/- 15.11 microm, respectively), whereas superonasal cornea had thicker mean values in both groups (632.43 +/- 6.11 microm and 648.78 +/- 14.98 microm in dry eye and normal eyes, respectively). CONCLUSIONS: Postmenopausal women with dry eye have lower corneal thickness values than postmenopausal women without dry eye. Special care must be taken with these reduced corneal thickness values when selecting postmenopausal women for surgery involving corneal photoablation.

Body Weights and Measures↗

Anatomic study of the corneal thickness of young emmetropic subjects.

PURPOSE: To study the corneal thickness of young emmetropic subjects. METHODS: One thousand eyes of 1000 young healthy emmetropic subjects were analyzed with the Orbscan Topography System II (Orbscan, Inc, Salt Lake City, UT) from January 2001 to May 2003. The age of the subjects ranged from 20 to 30 years old (mean +/- SD = 27.12 +/- 2.86). The mean of 5 consecutive measurements of the corneal thickness in the center of the cornea and at temporal, superotemporal, inferotemporal, nasal, inferonasal, and superonasal cornea were recorded. RESULTS: The corneal thickness at the following areas ranged as follows: 518 to 589 microm center; 603 to 678 microm nasal; 620 to 689 microm superonasal; 600 to 669 microm inferonasal; 571 to 639 microm temporal; 601 to 669 microm superotemporal; and 572 to 647 microm inferotemporal. In each individual the difference between the central thickness and the maximum paracentral thickness ranged from 85 to 107 microm (mean +/- SD, 99.21 +/- 3.80). The difference between the central thickness and the minimum paracentral thickness ranged from 36 to 59 microm (48.97 +/- 4.23 microm). The difference between the minimum paracentral corneal thickness and the maximum paracentral corneal thickness ranged from 37 to 58 microm (50.24 +/- 4.30). The tonometry was statistically correlated with the corneal thickness (P < 0.05 at each corneal location analyzed). CONCLUSIONS: In emmetropic corneas the difference between the minimum paracentral thickness and the maximum paracentral thickness was similar to the difference between the central thickness and the minimum paracentral thickness.

Adult↗

Goldmann tonometry after hyperopic laser in situ keratomileusis: comparison between retreated and nonretreated patients.

PURPOSE: To identify differences in applanation tonometry between retreated and nonretreated eyes (primary LASIK eyes) 6 months after hyperopic laser in situ keratomileusis. METHODS: In a prospective study 100 eyes (100 patients) underwent conventional hyperopic laser in situ keratomileusis under a 160-microm flap. Central Goldmann applanation tonometry was determined before and 6 months after surgery in 78 (78%) primary LASIK eyes and before surgery and 6 months after the retreatment date in 22 (22%) retreated eyes. RESULTS: Preoperative mean tonometry was 14.96 +/- 1.96 mm Hg and 15.30 +/- 1.95 mm Hg in primary LASIK and retreated eyes, respectively. Six months after surgery it was 12.99 +/- 2.03 mm Hg (P < 0.001) and 12.67 +/- 2.20 mm Hg (P < 0.001), respectively. No significant differences in mean tonometry were found between retreated and primary LASIK eyes 6 months after surgery (P = 0.537). Decreased tonometric values were found in 20 retreated eyes (90.91%) and in 62 primary LASIK eyes (79.48%). Increased tonometric values higher than 1 mm Hg were found in 3 primary LASIK eyes (3.84%), but no retreated eyes showed increased values 6 months after surgery. Two retreated eyes (9.09%) and 10 primary LASIK eyes (79.49%) presented the same tonometric values before surgery and at the end of the study. CONCLUSIONS: After hyperopic laser in situ keratomileusis there was no significant difference in Goldmann applanation tonometry between retreated and primary LASIK eyes.

Adult↗

Inter-observer variability of central corneal thickness measurements using non-contact specular microscopy after laser in situ keratomileusis.

BACKGROUND: The aim of this study was to investigate the inter-observer variability of central corneal thickness measurements carried out with a non-contact specular microscope in patients who had undergone myopic laser in situ keratomileusis. METHODS: Twenty-six eyes of 26 subjects who had undergone myopic laser in situ keratomileusis were studied with the Topcon SP-2000P non-contact specular microscope (Topcon Corp, Tokyo, Japan). The mean of three consecutive measurements of the central corneal thickness was recorded by two investigators prior to and one month after myopic laser in situ keratomileusis. Results obtained by each of the two physicians were compared. RESULTS: Prior to surgery the mean central corneal thickness was 536.2 +/- 22.2 microm for physician 1 and 536.3 +/- 22.2 microm for physician 2 (p = 0.980). The pre-operative 95 per cent confidence interval was 522.7 to 544.2 microm (physician 1) and 523.1 to 544.1 microm (physician 2). The mean central corneal thickness was 485.8 +/- 29.3 microm for physician 1 and 485.6 +/- 28.0 micro m for physician 2 one month after laser in situ keratomileusis (p = 0.977). The post-operative 95 per cent confidence intervals were 470.1 to 496.2 microm and 470.3 to 495.4 microm for physicians 1 and 2, respectively. CONCLUSION: Central corneal thickness measurements can be carried out by different clinicians after laser in situ keratomileusis with non-contact specular pachymetry, without there being any significant differences among them.

Adult↗

Corneal thickness values before and after oxybuprocaine 0.4% eye drops.

PURPOSE: To determine changes in corneal thickness after topical anesthesia. METHODS: Corneal thickness was measured before and 3 minutes after administration of two drops of oxybuprocaine 0.4% to 26 patients (26 eyes). We analyzed the corneal thickness of a control group, which was made up of 26 patients (26 eyes) before and 3 minutes after administration of two drops of saline solution. Corneal thickness was measured with the Orbscan Topography System II (Bausch Lomb Surg., Barcelona). RESULTS: Variations higher than +/- 10 microm were found following the instillation of 2 oxybuprocaine eye drops in eight eyes (30.76%) at the inferonasal cornea, in six eyes (23.08%) at the superotemporal, temporal and inferotemporal cornea, in five eyes (19.23%) at the nasal cornea, in three eyes (11.53%) at the central cornea, and in two eyes (7.69%) at the superonasal cornea. Nevertheless, no significant differences in the mean corneal thickness at each corneal location between the first and the second corneal thickness measurements were found in anesthetized eyes. CONCLUSIONS: Some individuals can present important increases and decreases in corneal thickness values after anesthetic eye drops. This effect of anesthetic eye drops must be considered by refractive surgeons when carrying out preoperative laser in situ keratomileusis corneal thickness measurements.

Adult↗

The relationship between central corneal thickness and Goldmann applanation tonometry.

BACKGROUND: The aim of this study was to investigate the relationship between Goldmann applanation tonometry and central corneal thickness in a large sample of healthy eyes. METHOD: Five hundred eyes of 500 subjects (253 women, 50.6 per cent and 247 men, 49.4 per cent) were analysed in a prospective healthy population study. Mean age of the sample was 31 +/- 8 years. Goldmann applanation tonometry was carried out by one physician. Tonometric values were the mean of three consecutive readings. Subsequently, another physician carried out ultrasonic pachymetry with the DGH 2000 AP ultrasonic pachymeter (DGH Technology Inc, San Diego, USA). Ten measurements were made at the centre of the cornea of each eye. The lowest value was used for analysis. RESULTS: Applanation tonometry and central corneal thickness were correlated (r = 0.184, p < 0.001). There was no significant correlation between corneal thickness and age (r = 0.083, p = 0.065), mean spherical equivalent refraction (r = 0.083, p = 0.065) or visual acuity (r = 0.036, p = 0.187). CONCLUSION: In normal eyes, there is no statistically significant correlation between changes of intraocular pressure and changes of central corneal thickness but they suggest a relationship between intraocular pressure and central corneal thickness. Goldmann applanation tonometry has a systematic error in accuracy of intraocular pressure readings of healthy eyes caused by its dependence on central corneal thickness. Measurement of corneal thickness by optometrists should be the first step in diagnosing intraocular pressure pathologies.

Adolescent↗

Extractable soil heavy metals following the cessation of biosolids application to agricultural soil.

Changes in soil heavy metal extractability following the cessation of biosolids applications were studied in a long-term field experiment. Two anaerobically digested biosolids from wastewater treatment plants in Madrid (Sur and Viveros) were applied to cropland from 1983 to 1990. Soil samples were collected in the 1st, 5th and 9th year after the last biosolids application. Soil pH did not vary significantly after biosolids applications. Organic matter and total heavy metals (Zn, Pb, Cd, Ni, Cr and Cu) concentrations initially increased but then declined over time, mostly after the first 5 years following biosolids application. Metal extracted with DPTA increased in Sur treatments during the 1st year and diminished thereafter. However, in Viveros treatments, heavy metals extracted increased during the 1st year, declined in 1995, and showed a slight increase in 1999. These changes in heavy metal extractability were widely observed in the percentage of extractable metal recovery (EMR). The differences observed in the pattern of the two sources of biosolids applied could be due to the different rates of decomposition of their organic matter.

Agriculture↗