PubMed Health⌕ Search

Biomedical subjects

Luis Gruberg

Publications and source records attributed to Luis Gruberg.

At least 37 records · Page 2Linked to original sources

The impact of GP IIb/IIIa inhibitors during primary percutaneous coronary intervention in acute myocardial infarction patients.

The use of glycoprotein (GP) IIb/IIIa inhibitors during percutaneous coronary interventions (PCI) in the acute phase of myocardial infarction (AMI) is still a matter of debate. The aim of the present study was to compare the outcomes of patients with acute ST-segment elevation myocardial infarction who underwent primary PCI and were concomitantly treated with GP IIb/IIIa inhibitors with those who were not treated with these drugs. Between January 1996 and November 2003, a total of 418 consecutive patients underwent PCI in the setting of ST-segment elevation AMI. At the operator's discretion, 287 patients were concomitantly treated with GP IIb/IIIa inhibitors and 115 patients were not. Angiographic success and final TIMI 3 flow in the infarct-related artery was achieved more frequently in patients treated with GP IIb/IIIa inhibitors (90% vs. 77%; p=0.001). The in-hospital composite endpoint of death, reinfarction and bleeding complications was significantly better in patients treated with GP IIb/IIIa inhibitors (4% vs. 12%; p=0.005). Furthermore, the adjusted 12-month survival rate was significantly better in these patients (RR: 2.99, CI: 1.29-6.9; p=0.01). Therefore, adjunctive therapy with GP IIbIIIa inhibitors during primary PCI is associated with improved short-term outcomes and one-year survival without an increased risk of bleeding.

Abciximab↗

Vertebral artery stenting using distal emboli protection and transcranial Doppler.

Recent studies have shown the feasibility and safety of the percutaneous approach for the treatment of vertebrobasilar disease using either balloon angioplasty alone, coronary stents, or combined angioplasty followed by stenting. The major concern in performing percutaneous procedures for the treatment of obstructive disease of the vertebrobasilar circulation involves the risk of embolic phenomena. We describe the successful treatment of a symptomatic patient with bilateral vertebrobasilar disease utilizing a distal protection filter during stenting with simultaneous use of transcranial Doppler to measure microembolization and vertebral artery blood flow during the procedure.

Blood Flow Velocity↗

Use of IIb/IIIa inhibitors in patients with in-stent restenosis treated with intracoronary gamma-radiation. Integrilin WRIST.

The Integrilin Washington Radiation for In-Stent Restenosis Trial (WRIST) aimed to study the impact of IIb/IIIa inhibitors as adjunct therapy to intracoronary radiation therapy (IRT) for patients with in-stent restenosis (ISR). The impact of GP IIb/IIIa inhibitor (eptifibatide) as adjunct therapy to vascular brachytherapy using (192)Ir emitter was examined in patients with in-stent restenosis. In the study, 150 patients were assigned to eptifibatide (Integrilin) and 150 patients to heparin only. Clinical composite endpoints at 30 days were similar between the patients treated with and without eptifibatide (4.7% vs. 4.0%; P = 0.78). There was a similarity in the non-Q-wave myocardial infarction (MI) rates between the eptifibatide and the control group. Major bleeding was similar in patients treated with and without eptifibatide. Overall, the use of eptifibatide as adjunct therapy for patients with ISR that are treated with IRT did not impact the clinical outcome at 30 days.

Aged↗

"No-reflow" phenomenon during percutaneous carotid angioplasty in a scleroderma patient.

Atherosclerosis remains the most common etiology of carotid artery stenosis, but other systemic diseases can also cause this disease. Percutaneous carotid angioplasty and stenting (CAS) with and without distal embolic protection devices is gaining acceptance as the treatment of choice. No-reflow phenomenon due to distal embolization has been previously described mainly during percutaneous intervention of degenerated saphenous vein graft. We describe a patient with systemic sclerosis who underwent CAS with distal embolic protection device with occurrence of no-reflow phenomenon during the procedure that resolved after retrieval of the filter device.

Aged↗

Platelet glycoprotein IIb/IIIa inhibitors during percutaneous coronary interventions: a pharmacological and clinical review.

One of the most significant advances of the last decade has been the development of platelet glycoprotein (GP) IIb/IIIa receptor inhibitors. A large series of randomised, controlled clinical trials of these agents have shown a significant reduction in ischaemic events, not only in acute coronary syndrome patients, but also in patients who undergo elective percutaneous coronary interventions. Even though the use of oral antiplatelet and antithrombotic therapies in addition to percutaneous coronary interventions have had a significant impact in clinical outcomes after acute coronary syndromes, the use of GP IIb/IIIa inhibitors provide additional protection against recurrent ischaemia and has been identified as the pivotal mediator of platelet aggregation, making it a logical target for the control of platelet response to vascular injury. A series of key trials performed over the last few years with GP IIb/IIIa inhibitors in patients undergoing percutaneous coronary intervention, have shown a reduction in the risk of short-term death and non-fatal myocardial infarction. The pharmacology and molecular basis of GP IIb/IIIa receptor inhibition and the use of these agents in patients undergoing percutaneous coronary intervention (during acute coronary syndromes and in elective procedures) and their safety issues will be reviewed. A special emphasis has been made on the role of these agents in diabetic patients and their beneficial effect in reducing peri-procedural creatine kinase myocardial band fraction elevation and associated complications.

Acute Disease↗

Percutaneous coronary interventions in diabetic patients: is complete revascularization important?

BACKGROUND: The long-term prognosis of diabetic patients with multivessel coronary artery disease (CAD) treated by surgical or percutaneous coronary revascularization is significantly worse as compared to non-diabetics. Lower rates of complete revascularization may be one factor that influences the poor long-term outcome in the diabetic population. Our study assessed the impact of complete revascularization on the long-term prognosis in diabetic patients with CAD treated by percutaneous coronary intervention (PCI). The study included 658 consecutive diabetic patients (mean age, 60.9+/-10.1 years) who underwent PCI. Multivessel disease was present in 352 patients (53.5%). Revascularization was complete in 94 (26.7%) and incomplete in 258 (73.3%) patients with multivessel disease. Reasons for incomplete revascularization included angioplasty of only the culprit lesion (43.4%); small vessel size (22.8%); moderate lesion, defined as diameter stenosis 50-69% (18.6%); chronic total occlusion of the non-intervened vessel (6.6%); and others (8.5%). Overall survival rate at 5 years was 87.4%. Patients who underwent complete revascularization had a 94.5% survival rate, compared to 83.0% for those with incomplete revascularization (p<0.001). Similarly, the rates of myocardial infarction-free survival were significantly higher in patients with complete versus incomplete revascularization (92.9% versus 79.9%, respectively). Incomplete revascularization was the most powerful independent predictor of mortality at follow-up (relative risk 95% confidence interval, 1.54-7.69; p=0.003). Our data suggest that complete myocardial revascularization may improve the long-term prognosis after PCI of diabetic patients with multivessel CAD.

Adult↗

Traditional versus automated injection contrast system in diagnostic and percutaneous coronary interventional procedures: comparison of the contrast volume delivered.

UNLABELLED: Contrast injection with a manual stopcock-manifold system is the standard technique during diagnostic coronary angiography or percutaneous coronary intervention (PCI). The ACIST Injection System is a new automatic injection device that allows online hemodynamic monitoring, as well as control of injection rate and amount of contrast to be delivered. The aim of the study was to compare the amount of contrast media delivered using the two methods, i.e., the traditional (manual injection plus standard power injection for the left ventriculography using the ANGIOMAT-6000) versus the ACIST System programmed injector. A total of 453 consecutive patients underwent diagnostic cardiac catheterization and/or PCI at our institution. Patients were randomly assigned to either automated contrast injection with the ACIST device (n = 253) or to conventional contrast injection using a stopcock-manifold system and contrast injection by hand syringe (n = 200). In the diagnostic catheterization group, the mean quantity of contrast volume was significantly lower in the ACIST group compared to the control group (130 +/- 60 ml versus 257 +/- 64 ml, respectively; 97.4% more contrast media; p < 0.001). When the data were analyzed for patients who underwent diagnostic catheterization plus PCI, the mean quantity of contrast volume was 228 +/- 90 ml versus 350 +/- 94 ml, respectively (53.8% more contrast media; p < 0.001). For patients who underwent PCI alone, the mean quantity of contrast volume was 175 +/- 76 ml versus 275 +/- 100 ml, respectively (57.3% more contrast media; p = 0.009). When only the total volume of contrast media delivered to the patient was considered (not including the contrast wasted outside), the results were very similar. CONCLUSION: There was a significant reduction in the total volume of contrast media used (amount injected to the patient as well as the amount wasted) and in the net amount of contrast delivered to the patient with the ACIST power device when compared to the traditional method of manual contrast injection.

Angioplasty, Balloon, Coronary↗

Percutaneous coronary intervention-associated nephropathy foreshadows increased risk of late adverse events in patients with normal baseline serum creatinine.

In patients with chronic renal insufficiency, further decline in renal function (DRF) after percutaneous coronary intervention (PCI) is accompanied not only by adverse in-hospital events but also by increased risk of mortality and myocardial infarction at 1 year. This analysis was undertaken to determine if patients with normal renal function who develop DRF after PCI have a comparable increase in risk of death and myocardial infarction at 1 year, and whether this risk is independent of in-hospital complications (death, myocardial infarction, urgent coronary artery bypass grafting). We performed a retrospective analysis of all patients from a single center who underwent successful PCI with no major in-hospital complications who had pre-PCI serum creatinine (SCr) </= 1.2 mg/dl and no history of renal insufficiency. One-year follow-up was obtained by mail or telephone. There were 5,967 consecutive patients who met the inclusion criteria. Of these, 208 (3.5%) developed DRF (an increase in SCr >/= 50% of baseline). They were more likely to be older, female, non-Caucasian, diabetic and/or hypertensive. They reported more prior cerebral or peripheral vascular events. They had undergone more complex PCI and were exposed to more radiographic contrast than the 96.5% who did not develop DRF. After adjustment for baseline variables, DRF remained an independent predictor of 1-year mortality, myocardial infarction, and target vessel revascularization. In patients without prior renal impairment, DRF post-PCI is rare but is associated with an increased risk of late adverse cardiac events similar to that in chronic renal insufficiency patients.

Acute Kidney Injury↗

Stent deployment failure: reasons, implications, and short- and long-term outcomes.

Stents have revolutionized percutaneous coronary interventions (PCI), impacting on both acute and long-term results. However, despite improvements in stent design, stent deployment failure is not an unusual event. The aim of the present study was to assess the frequency and causes of stent deployment failure, as well as the outcome of these patients. Between 1997 and 2001, a total of 3,537 patients underwent stent-assisted PCI and delivery of 5,275 stents was attempted. In the majority of patients (118; 78.1%), stenting was performed as provisional; in the remaining 33 (21.8%) as a bailout procedure. A total of 175 (3.3%) stents in 151 (4.3%) patients failed. Failure to deliver the stent to the lesion site was the main cause in 139 patients (92%) and failure either to expand adequately the stent or premature disengagement of the stent from the balloon in only 12 patients (8%). Peripheral stent embolization occurred in 10 (0.3%) patients. Deployment of a different stent in place of the failed one was attempted in 122 patients and was successful in the majority (108; 88.5%). In-hospital major adverse cardiac events were observed in six patients (4%): three patients required emergency coronary artery bypass surgery, two had a myocardial infarction (MI), and one patient underwent urgent repeat coronary intervention. At a mean follow-up of 32.2 +/- 17.7 months, 22 major adverse cardiac event occurred in 17 patients (11.2%): 1 cardiac death, 3 patients had an MI, and 18 patients required target vessel revascularization. One-year event-free survival for the whole group was 91.2%. Patients with stent embolization did not have any major adverse cardiac or vascular events. Thus, the rate of stent deployment failure in our series was 3.3%, mainly due to failure to deliver the stent to the site. Another stent was successfully deployed in the majority of cases and these patients had favorable short- and long-term outcomes.

Aged↗

Clinical outcomes following stent implantation in internal mammary artery grafts.

We evaluated our experience with percutaneous coronary intervention (PCI) of internal mammary artery (IMA) grafts. From the institution's database we identified 288 patients with 311 IMA lesions. Of these, 82 (26.4%) had stents placed during PCI. Angiographic success was 92%. Mortality at 1 month was 1.7%, myocardial infarction (MI) 15.7%, and target lesion revascularization (TLR) 0.4%. Cumulative 1-year event rates were mortality 6.4%, MI 20.4%, and TLR 8.0%. TLR rates were significantly higher in the stented lesions than lesions treated with angioplasty alone (19.2% vs. 4.9%; P = 0.004). The higher TLR rate in stented lesions was most apparent at the anastomotic site (25.0% vs. 4.2%; P = 0.006). Percutaneous revascularization of IMA grafts can be performed safely with high procedural success and excellent short- and long-term results. Stenting, particularly at the anastomotic site, was associated with significantly greater rates of TLR than angioplasty alone.

Aged↗

Late stent thrombosis after implantation of a sirolimus-eluting stent.

Late stent thrombosis in the era of routine high-pressure stent deployment and combined antiplatelet therapy with thienopyridines and aspirin has become a rare but feared complication. We describe a patient with acute myocardial infarction due to late stent thrombosis 6 weeks after deployment of a sirolimus-eluting stent and 2 weeks after the discontinuation of clopidogrel. This is the first report of late thrombosis of a sirolimus-eluting stent.

Aged↗

Diagnostic coronary angiography induces a systemic inflammatory response in patients with stable angina.

BACKGROUND: Systemic markers of inflammation increase after percutaneous coronary intervention (PCI). The rise in inflammatory markers after PCI is frequently attributed to the inflammatory stimulus associated with coronary artery injury during balloon inflation and coronary stent implantation. The aim of this study was the determine whether diagnostic coronary angiography performed in patients with stable angina triggers a systemic inflammatory response. METHODS: We prospectively studied patients with chronic stable angina undergoing either coronary angiography (n = 13) or coronary angiography followed by PCI (n = 13). Peripheral blood samples were obtained before and 24 hours, 48 hours, and 4 weeks after the procedure and analyzed for C-reactive protein (CRP), interleukin-6 (IL-6), and tumor necrosis factor-alpha (TNF-alpha). Patients with periprocedural myocardial necrosis were excluded. RESULTS: There was a significant increase in CRP levels at 24 and 48 hours in both the coronary angiography (P <.05) and PCI (P <.01) groups. IL-6 levels peaked at 24 hours in both the coronary angiography (median, 2.5-9.5 pg/mL; P =.01) and PCI (median, 3.0-8.2 pg/mL; P <.005) groups. At 4 weeks, both CRP and IL-6 returned to baseline levels. TNF-alpha levels were unchanged with either coronary angiography or PCI. The magnitude of the rise of CRP and IL-6 levels was not significantly different between the groups. There was a fair correlation between baseline and peak postprocedural levels of CRP (r = 0.67, P =.008) and IL-6 (r = 0.48, P =.016). CONCLUSION: Uncomplicated diagnostic coronary angiography triggers a systemic inflammatory response in patients with stable angina. The contribution of coronary angiography should be considered in interpreting the significance of the systemic inflammatory response observed after PCI.

Angina Pectoris↗

Impact of renal function on morbidity and mortality after percutaneous aortocoronary saphenous vein graft intervention.

BACKGROUND: Percutaneous coronary intervention in patients with chronic renal insufficiency (CRI) and native coronary artery disease is often problematic, marred by increased morbidity and mortality rates and a high incidence of restenosis and revascularization. However, little is known about the effect of CRI in patients who have undergone prior coronary artery bypass graft surgery and then undergo saphenous vein graft (SVG) intervention. METHODS: We analyzed the inhospital and 1-year outcomes of 1265 consecutive patients with normal renal function and varying degrees of renal insufficiency who underwent percutaneous SVG intervention and divided them into 4 groups on the basis of the calculated creatinine clearance (CrCl): group 1, CrCl > or =70 mL per minute (n = 626); group 2, CrCl 50 to 69 mL per minute (n = 357); group 3, CrCl 30 to 49 mL per minute (n = 228); and group 4, CrCl <30 mL per minute (n = 54). Patients undergoing dialysis replacement therapy were excluded from the study. RESULTS: Patients with lower CrCl more often were older, female, had diabetes mellitus, and had worse left ventricular function. Angiographic baseline characteristics were comparable among the 4 groups. Overall immediate procedural success was similar for all groups. Patients with a low CrCl had significantly higher inhospital overall and cardiac mortality rates (P <.001), including a significantly higher incidence of myocardial infarction, vascular complications, pulmonary edema, and renal function deterioration. At 1-year follow-up, the overall mortality rates remained significantly higher in patients with decreased CrCl, with an incremental rise in overall mortality rate associated with lower renal function (P <.001). CONCLUSIONS: This study suggests that renal function is a primary determinate of short- and long-term survival in patients undergoing percutaneous SVG intervention and that there is a clear relationship between CrCl and cardiovascular outcome.

Age Factors↗

Prolonged systemic delivery of tirofiban in a thrombus-laden saphenous vein graft.

Results from previous trials have shown conflicting results from local delivery of thrombolytic agents to diminish thrombus burden before intervention in native coronary arteries and saphenous vein grafts. We described a patient with an acute coronary syndrome who was treated for 24 hours with systemic tirofiban (Aggrastat), a glycoprotein IIb/IIIa inhibitor, for the treatment of a degenerated saphenous vein graft with a TIMI grade 4 thrombus (large-sized thrombus). Angiographic evaluation 48 hours later revealed complete resolution of the thrombus with normal coronary blood flow.

Aged↗

Radiocontrast-induced nephropathy and percutaneous coronary intervention: a review of preventive measures.

Injectable and absorbable contrast media for the use in radiology, all of which contains iodine as an essential component, has been, and continues to be, one of the main sources of agents which cause hospital-acquired renal failure. Although numerous methods have been explored to prevent renal contrast damage, radiocontrast-induced nephropathy continues to be a concern in patients with existing renal insufficiency, who undergo contrast-enhanced radiographic examinations. Patients who develop contrast-induced nephropathy (CIN) have a worse prognosis and an increased risk of complications and mortality. Prevention of CIN during radiocontrast procedures continues to elude clinicians and is a chief concern during percutaneous coronary intervention, as these patients often have multiple comorbidities. A wide variety of animal and clinical investigations, and substances have been tried in order to prevent this complication, including: dialysis, contrast volume and type; adenosine antagonists; acetylcysteine; fenoldopam; and various others. The purpose of this review is to appraise all the past and current strategies employed to prevent CIN, especially during percutaneous coronary intervention.

Angioplasty, Balloon, Coronary↗