PubMed Health⌕ Search

Biomedical subjects

Lukas Trojer

Publications and source records attributed to Lukas Trojer.

3 recordsLinked to original sources

A new analytical material-enhanced laser desorption ionization (MELDI) based approach for the determination of low-mass serum constituents using fullerene derivatives for selective enrichment.

60]fullerene derivatives (dioctadecyl methano[60]fullerene, [60]fullerenoacetic acid, and IDA-[60]fullerene) were prepared and subjected to a comprehensive characterization study including protein binding properties and capacity. These fullerene derivatives were successfully applied as material-enhanced laser desorption/ionization (MELDI) carrier materials. It is shown that diverse functionalities result in characteristic human serum peak patterns (m/z 2000-20 000) in terms of signal intensity as well as the number of detectable masses. In addition, the fullerene derivatives clearly provided differences in the low molecular weight mass region (m/z 1000-4000) after elution of the adsorbed serum constituents, and [60]fullerenoacetic acid was the most effective carrier material. Novel high-speed, monolithic, high-resolution capillary columns, prepared by thermally initiated copolymerization of methylstyrene (MSt) and 1,2-bis(p-vinylphenyl)ethane (BVPE) were employed for eluate separation and target spotting. Thus, serum compounds in the low-mass range were successfully fractionated and subjected to MALDI-MS/MS analysis. This contribution, hence, proposes a new "top-down" strategy for proteome research enabling protein profiling as well as biomarker identification in the low-mass range using selective enrichment, high-resolution separation, and offline MALDI-MS/MS evaluation.

Adsorption↗

Material-enhanced laser desorption/ionization (MELDI)--a new protein profiling tool utilizing specific carrier materials for time of flight mass spectrometric analysis.

Over the past couple of years, proteomics pattern analysis has emerged as an effective method for the early diagnosis of diseases such as ovarian, breast, or prostate cancer, without identification of single biomarkers. MALDI-TOF MS, for example, offers a simple approach for fast and reliable protein profiling, especially by using carrier materials with various physical and chemical properties, in combination with a MALDI matrix. This approach is referred to as material-enhanced laser desorption/ionization (MELDI). In this paper, we report the development and application of derivatized carrier materials [cellulose, silica, poly(glycidyl methacrylate/divinylbenzene) (GMA/DVB) particles, and diamond powder] for fast and direct MALDI-TOF MS protein profiling. The applicability of MELDI for rapid protein profiling was evaluated with human serum samples. These carriers, having various hydrophobicities, resulted in characteristic mass fingerprints, even if all materials were derivatized with iminodiacetic acid (IDA) to yield an immobilized metal affinity chromatography (IMAC) functionality. Our study demonstrates that analyzing complex biological samples, such as human serum, by employing different MELDI carrier materials yielded type- and size-dependent performance variation.

Indicators and Reagents↗

Monolithic poly(p-methylstyrene-co-1,2-bis(p-vinylphenyl)ethane) capillary columns as novel styrene stationary phases for biopolymer separation.

Novel monolithic capillary supports (200 microm I.D.) were prepared by polymerisation of methylstyrene (MS) and 1,2-bis(p-vinylphenyl)ethane (BVPE) as a crosslinker in the presence of inert diluents (porogens). These polymeric reversed-phases (MS/BVPE) showed excellent mechanical stability and minimised swelling in organic solvents. The chromatographic potential of monolithic MS/BVPE as a stationary phase for micro-high-performance liquid chromatography (mu-HPLC) was investigated by the separation of proteins and peptides applying reversed-phase (RP) and nucleic acids applying ion-pair reversed-phase (IP-RP) conditions. The permeability and chromatographic efficiency of the capillary columns were found to be highly influenced by the total monomer to porogen content as well as by the microporogen nature and its ratio. In the course of these optimisation studies, monoliths covering a broad permeability range were fabricated. The application of volumetric flow rates up to 200 microl/min allowed swift resolution of proteins, while smaller biomolecules were successfully separated at a higher overall porosity. A protein test mixture containing ribonuclease A, cytochrome c, alpha-lactalbumin, beta-lactoglobulin B and ovalbumin was thus baseline separated in 35s, a homologous series of phosphorylated oligothymidylic acids [d(pT)12-18] in less than 2 min.

Biopolymers↗