PubMed Health⌕ Search

Biomedical subjects

Lutz Claes

Publications and source records attributed to Lutz Claes.

At least 37 records · Page 2Linked to original sources

In vitro stabilizing effect of a transforaminal compared with two posterior lumbar interbody fusion cages.

STUDY DESIGN: An in vitro biomechanical flexibility test on different lumbar interbody fusion cages using monosegmental lumbar spine specimens. OBJECTIVE: To investigate the stabilizing effect of a transforaminal lumbar interbody fusion (TLIF) cage compared with two established posterior lumbar interbody fusion (PLIF) cages. SUMMARY OF BACKGROUND DATA: TLIF using interbody fusion cages is gaining more and more popularity in the treatment of degenerative disc disease. However, only little is known on its biomechanical behavior. METHODS: Eighteen intact human lumbar spine segments were tested for flexibility in a specially designed spine tester. Pure moments were applied in the three main planes, and range of motion and neutral zone were determined. Then, TLIF using the sickle-shaped MOON cage (AMT AG), PLIF using the cubic Stryker cages (Stryker Orthopaedics), or PLIF using the threaded BAK cages (Zimmer Spinetech) was carried out and the specimens tested again. RESULTS: The stability after implantation of the MOON TLIF cage did not significantly differ from that after implantation of the cubic Stryker PLIF cages (P > 0.05). In contrast, the threaded BAK PLIF cages had a significantly higher primary stability than both the MOON TLIF and the Stryker PLIF cages in lateral bending, flexion, and extension (P < 0.05) but not in axial rotation (P > 0.05). CONCLUSIONS: In terms of its stabilizing effect, TLIF using the MOON cage can be recommended as an alternative to PLIF using the cubic Stryker cages. Compared with the threaded BAK PLIF cages, however, the MOON TLIF cage provides a lower primary stability in lateral bending, flexion, and extension.

Benzophenones↗

Limitations of the cervical porcine spine in evaluating spinal implants in comparison with human cervical spinal segments: a biomechanical in vitro comparison of porcine and human cervical spine specimens with different instrumentation techniques.

STUDY DESIGN: Porcine and human cervical spine specimens were in vitro biomechanically compared with different instrumentation techniques. OBJECTIVES: To evaluate whether subaxial porcine cervical spines are a valid model for implant testing in a single level corpectomy. SUMMARY OF BACKGROUND DATA: Biomechanical in vitro tests are widely used for implant tests, mainly with human spine specimens. The availability of human cadavers is limited and the properties of the specimen regarding age, bone mineral density, and grade of degenerative changes is inhomogeneous. METHODS: Six porcine and six human cervical specimens were loaded nondestructively with pure moments: 1) in an intact state; 2) after a corpectomy of C5 and substitution by a cage with integrated force sensor; 3) after additional instrumentation with a posterior screw and rod system with: a) lateral mass and b) pedicle screws; 4) after instrumentation with an anterior plate; and 5) with a circumferential instrumentation. The unconstrained motion and the axial loads occurring in the corpectomy gap were measured, as well as the bone mineral density of the specimen before testing. RESULTS: The range of motion in the intact state, as well as for the different instrumentations, was comparable for flexion-extension. In lateral bending and axial rotation, marked differences in the intact state as well as for pedicle screw instrumentations occurred. CONCLUSIONS: The subaxial porcine cervical spine is a potential model in flexion-extension because of its biomechanical similarity. For lateral bending and axial rotation, the marked differences severly restrict the comparability.

Aged↗

Biomechanical in vitro comparison of different mono- and bisegmental anterior procedures with regard to the strategy for fracture stabilisation using minimally invasive techniques.

Endoscopic minimally invasive techniques have become an established method of fracture stabilisation in the spine. In view of this fact, anterior stabilisation strategies must be reconsidered, as monosegmental A 3.1 compression fractures are increasingly being stabilised endoscopically from the anterior aspect using minimally invasive techniques. This study investigated the biomechanical necessity of anterior two-point or four-point stabilisation in the instrumentation of mono- and bisegmental fractures. In three biomechanical in vitro studies, burst fracture stabilisation was simulated, and anterior short fixation devices were tested under load with pure moments up to 3.75 Nm to evaluate the biomechanical stabilising characteristics of different kinds of instrumentations in flexion/extension, lateral bending, and axial rotation. Only anterior four-point stabilisation resulted in sufficient primary stability both in mono- and bisegmental instrumentation and therefore represents the standard procedure in open as well as in minimally invasive spinal surgery.

Biomechanical Phenomena↗

Trabecular bone fracture healing simulation with finite element analysis and fuzzy logic.

Trabecular bone fractures heal through intramembraneous ossification. This process differs from diaphyseal fracture healing in that the trabecular marrow provides a rich vascular supply to the healing bone, there is very little callus formation, woven bone forms directly without a cartilage intermediary, and the woven bone is remodelled to form trabecular bone. Previous studies have used numerical methods to simulate diaphyseal fracture healing or bone remodelling, however not trabecular fracture healing, which involves both tissue differentiation and trabecular formation. The objective of this study was to determine if intramembraneous bone formation and remodelling during trabecular bone fracture healing could be simulated using the same mechanobiological principles as those proposed for diaphyseal fracture healing. Using finite element analysis and the fuzzy logic for diaphyseal healing, the model simulated formation of woven bone in the fracture gap and subsequent remodelling of the bone to form trabecular bone. We also demonstrated that the trabecular structure is dependent on the applied loading conditions. A single model that can simulate bone healing and remodelling may prove to be a useful tool in predicting musculoskeletal tissue differentiation in different vascular and mechanical environments.

Animals↗

Biocompatibility and functionality of the degradable polymer alkylene bis(dilactoyl)-methacrylate for screw augmentation in vivo.

Recently, a new degradable polymer has been developed on the basis of alkylene bis(dilactoyl)-methacrylate as an alternative material for screw augmentation. The polymer has been investigated in vitro and in a short-term experiment in rabbits exhibiting promising results. The aim of the present study was to investigate its long-term biocompatibility and mechanical functionality in a large animal model. The polymer was used for screw augmentation in the cancellous bone of the femoral condyle and tibia epiphysis of 12 sheep and was compared to polymethylmethacrylate (PMMA) augmented and nonaugmented screws. After an implantation period of 6 months, bone, regional lymph nodes, and several organs were histologically evaluated. The mechanical efficacy was investigated by a biomechanical pullout test. A lot of mononuclear macrophages and multinuclear foreign body giant cells with incorporated polymer particles indicate strong inflammatory reactions. Large osteolysis zones with osteoclasts were found in the surrounding polymer. The polymer was fragmented but not substantially degraded. Polymer particles were also found in the regional lymph nodes. Lung, liver, kidney, and spleen did not show any pathological signs. The pullout force of screws augmented with the new polymer was significantly reduced in comparison to PMMA augmented and nonaugmented screws, respectively. It was concluded that the material has poor biocompatibility and cannot be recommended for clinical application as screw augmentation material.

Animals↗

Osseointegration of alumina with a bioactive coating under load-bearing and unloaded conditions.

The aim of the study was to evaluate the osseointegration of Al(2)O(3) coated with a bioactive glass ceramic (BioveritI), in a load-bearing implant model in sheep in comparison to uncoated Al(2)O(3) and to a minimally loaded situation. Both types of implants were inserted into the proximal tibia (load-bearing model) and in a drill hole defect into the tibia diaphysis (minimally loaded model). Under load-bearing conditions, the coating resulted in significantly higher interfacial shear strength and a high amount of mineralized bone in direct contact to the implant surface. In contrast, the uncoated Al(2)O(3) was surrounded by a thick connective tissue layer corresponding to low interfacial shear strength. In the minimally loaded model, however, there was rather a tendency of lower interfacial shear strength in the case of the coated implants. This finding corresponds to the histological results, which showed mineralized bone in the interface of uncoated Al(2)O(3), whereas in the case of the coated implants a thin layer of osteoid was observed. It was suggested that the osseointegration of Al(2)O(3) could be improved by the coating under load-bearing conditions, under which uncoated Al(2)O(3) ceramics cannot directly bind to bone.

Aluminum Oxide↗

Prediction of fracture callus mechanical properties using micro-CT images and voxel-based finite element analysis.

Assessment of fracture healing is a common problem in orthopaedic practice and research. To determine the effectiveness of certain treatments, drugs, mechanical loads, or rehabilitation regimes, the strength of the fracture callus must be determined. Both clinically and experimentally, there is a need to noninvasively and quantitatively evaluate fracture callus quality during healing. The objective of this study was to develop a method to assess fracture stiffness using micro-computed tomography (micro-CT) and finite element analysis. The method was developed and validated with plastic phantoms of various cross sections and known material properties, tested experimentally in four-point bending and torsion. The method was then applied to fractured rat femurs after 3 and 4 weeks of healing tested experimentally in torsion (50 femurs total). Micro-CT scans were made of the fracture calluses to determine three-dimensional geometry and material properties for the finite element models. Experimentally measured torsional rigidities were compared to finite element solutions. Finite element model predictions of callus rigidity correlated significantly better with experimental torsional rigidity than other common measures of healing progress such as callus area, bone mineral density, or area moment of inertia. Using FEA to predict mechanical properties of the callus could prove to be a useful tool in fracture-healing studies.

Animals↗

Inhibition of cortical and cancellous bone formation in glucocorticoid-treated OVX sheep.

INTRODUCTION: Little is known about the effects of steroids on cortical bone. The purpose of this study was to explore the effects of glucocorticoid treatment on cortical bone density, strength, and formation of new bone in ovariectomized sheep and to compare it to cancellous bone. MATERIALS AND METHODS: Sixteen ovariectomized merino sheep either received a 6-month glucocorticoid treatment (GLU; 0.45 mg/kg/day Methylprednisolone s.c.) or were left untreated (control). After 2 and 4 months, newly formed bone was labeled by the administration of calceingreen and Tetracycline-hydrochloride. After 12 months, the animals were sacrificed and cortical specimens were obtained from the tibial diaphysis. Cancellous bone specimens were harvested from the proximal tibia. All specimens were scanned for apparent BMD by pQCT and tested mechanically. Formation of new bone was analyzed using histological slices of the femoral condyles and cross-sections of the mid-diaphysis of the tibia. RESULTS: The intracortical formation of new bone in glucocorticoid-treated sheep was 70% lower after 2 months and 80% lower after 4 months. Six months after the termination of the steroid administration, the active bone area was 20% lower than in the control group. Cortical width and cortical bone area were reduced by 7-8% and marrow area increased by 8% in steroid-treated animals compared to control animals. Neither cortical apparent bone mineral density nor biomechanical parameters of cortical bone specimens differed between the groups. Cancellous bone formation in steroid-treated animals declined by 68% after 2 months and by 90% after 4 months. After 1 year, cancellous bone formation was reduced by 38% compared to control. The apparent cancellous bone mineral density and cancellous bone compressive stiffness were reduced by 34% and 55%, respectively. CONCLUSION: A six-month glucocorticoid treatment of ovariectomized sheep resulted in a substantial reduction of bone formation both in cortical and in cancellous bone and reduced cortical width by increased endosteal resorption. Beyond changes in cancellous bone, impaired cortical bone remodeling may add to the increased fracture risk at the hip or the distal radius in patients treated with steroids.

Animals↗

Intact fibula improves fracture healing in a rat tibia osteotomy model.

Rat tibia fractures are often used in fracture healing studies. Usually the fracture is stabilized with an intramedullary pin, which provides bending stiffness, but little torsional stiffness. The objective of this research was to determine the in vitro torsional rigidity of an osteotomized tibia with and without the fibula, and to determine if this difference influences the healing process in vivo. In vitro eleven rat tibias received an osteotomy, were stabilized with an intramedullary pin, and were tested in internal rotation to determine the torsional rigidity. The fibula was then manually broken and the torsional rigidity measured again. In vivo 18 rats received a tibial osteotomy, eight of which had an additional fractured fibula. After three weeks, the rats were sacrificed and the tibias were analyzed. Bone density in the fracture callus was measured with qCT. Bending rigidity and maximum breaking moment were determined in three-point bending. In vitro testing demonstrated that the torsional rigidity with an intact fibula was nearly two times higher than when the fibula was fractured. Though the torsional rigidity was still small in comparison with an intact bone, it resulted in a significantly different healing process in vivo. Rats with intact fibulas had significantly higher bone mineral density, bending rigidity, and maximum breaking moment compared to rats with a fractured fibula. These results indicate that torsional stability considerably affects the healing process. In a fracture model, it is critical to characterize the mechanical environment of the fracture.

Animals↗

Low-intensity ultrasound enhances maturation of callus after segmental transport.

The purpose of this study was to determine whether low-intensity ultrasound can be used to enhance callus maturation. Fifteen-millimeter bone defects at the metatarsal bones of sheep were treated with a segmental bone transport for 16 days. The callus formations in the bone defects were allowed to mature for 63 days before the animals were sacrificed. Eighteen sheep were operated on and divided into two groups. One group was treated with low-intensity ultrasound for 20 minutes per day, whereas the other group served as an untreated control group. Biomechanical tests after removal of the metatarsals showed significantly higher axial compression stiffness and significantly higher indentation stiffness of callus tissue in the healing zone in the group treated with ultrasound. Also, histologic analysis of the cortical defect zone showed significantly more callus formation and more active zones of endochondral ossification in the group treated with ultrasound. Stimulation of callus maturation by ultrasound is possible, similar to stimulation of fresh fracture healing, and may be used to shorten clinical treatment times.

Animals↗

The peroneal reaction time (PRT)--reference data in a healthy sample population.

BACKGROUND: Acute ankle sprains can result in severe residual symptoms, such as chronic ankle instability from weakness of the ligamentous complex or neuromuscular deficits. Measuring peroneal reaction time (PRT) has become a commonly accepted procedure for evaluating proprioceptive deficits. METHODS: The present experimental study was conducted to determine the effects of anthropometric factors on PRT in 120 healthy volunteers. The patients were asked to stand on a platform with a tilting mechanism. Surface electrodes were used to record peroneal muscle activity in response to sudden inversion stress. The reaction of the peroneal muscles was analyzed using electromyography. RESULTS: The statistical analysis showed similar intra-individual and inter-individual values for PRT. The results for the muscle groups measurements, however, varied considerably. PRT seems to increase significantly with age (long peroneal muscle: p < 0.0001, short peroneal muscle: p = 0.004). CONCLUSIONS: PRT was found to be an objective parameter that is unaffected by extrinsic and intrinsic factors. The present study, however, also showed that PRT significantly increases with age. As for studies on PRT, as well as for clinical routine, it is important to consider the patients' ages.

Adolescent↗

A three-dimensional collagen matrix as a suitable culture system for the comparison of cyclic strain and hydrostatic pressure effects on intervertebral disc cells.

OBJECT: To study intervertebral disc cell mechanobiology, the authors developed experimental systems that allow the application of cyclic strain and intermittent hydrostatic pressure (IHP) on isolated disc cells under equal three-dimensional (3D) culture conditions. The purpose of the study was to characterize disc cell proliferation, viability, morphology, and gene expression in 3D collagen matrices. METHODS: The effects of cyclic strain (1, 2, 4, and 8% strain; 1 Hz) and IHP (0.25 MPa, 0.1 Hz) on gene expression (real-time polymerase chain reaction) of anabolic and catabolic matrix proteins were investigated and compared with those derived from mechanically unstimulated controls. Intervertebral disc cells proliferated in the collagen gels (mean viability 91.6%) and expressed messenger RNA for collagen I, collagen II, aggrecan, matrix metalloproteinase (MMP)-2, and MMP-3. Morphologically, both spindle-shaped cells with longer processes and rounded cells were detected in the collagen scaffolds. Cyclic strain increased collagen II and aggrecan expression and decreased MMP-3 expression of anulus fibrosus cells. No significant difference between the four strain magnitudes was found. Intermittent hydrostatic pressure tended to increase collagen I and aggrecan expression of nucleus cells and significantly decreased MMP-2 and -3 expression of nucleus cells, whereas aggrecan expression of anulus cells tended to decrease. CONCLUSIONS: Based on these results, the collagen matrix appeared to be a suitable substrate to apply both cyclic strain and IHP to intervertebral disc cells under 3D culture conditions. Individual variations may be influenced by the extent of degeneration of the disc specimens from which the cells were isolated. This experimental setup may be suitable for studying the influence of degeneration on the disc cell response to mechanical stimuli.

Aggrecans↗

Correlation between neck injury risk and impact severity parameters in low-speed side collisions.

STUDY DESIGN: In vitro acceleration study on human cadaveric cervical spine specimens. OBJECTIVES: To investigate the correlation between the risk to sustain a structural cervical spine injury and vehicle-related impact severity parameters. SUMMARY OF BACKGROUND DATA: Impact severity parameters, such as the peak acceleration of the vehicle, its mean acceleration, and its velocity change, are often used to predict the whiplash injury risk or to objectify the patient's symptoms even though their correlation to injury is still not well understood. METHODS: In a series of three in vitro experiments, a total of 18 human cadaveric cervical spine specimens were subjected to incremental side accelerations until structural injury occurred. While the duration of the acceleration pulse was kept constant throughout all three experiments, its shape was varied: In Experiment I, the acceleration pulse had a fast increase up to the maximum value and a fast decrease down to zero (fast-fast). Experiment II was characterized by a slow increase and fast decrease (slow-fast), and Experiment III was characterized by a fast increase and a slow decrease (fast-slow). RESULTS: The specimens of Experiment II (slow-fast) sustained structural injury at a significantly higher peak acceleration of the sled (4.6 g on average) than those of Experiments I (fast-fast) (2.6 g) and III (fast-slow) (3.1 g). In contrast, mean acceleration and velocity change of the injuring impacts were almost the same in all three experiments. CONCLUSION: The injury risk to the cervical spine was predictable by the mean acceleration of the sled and since the duration of the crash pulses was constant also by its velocity change but not by its peak acceleration.

Acceleration↗

Mechanics and mechano-biology of fracture healing in normal and osteoporotic bone.

Fracture repair, which aims at regaining the functional competence of a bone, is a complex and multifactorial process. For the success of fracture repair biology and mechanics are of immense importance. The biological and mechanical environments must be compatible with the processes of cell and tissue proliferation and differentiation. The biological environment is characterized by the vascular supply and by many biochemical components, the biochemical milieu. A good vascular supply is a prerequisite for the initiation of the fracture repair process. The biochemical milieu involves complex interactions among local and systemic regulatory factors such as growth factors or cytokines. The mechanical environment is determined by the local stress and strain within the fracture. However, the local stress and strain is not accessible, and the mechanical environment, therefore, is described by global mechanical factors, e.g., gap size or interfragmentary movement. The relationship between local stress and strain and the global mechanical factors can be obtained by numerical models (Finite Element Model). Moreover, there is considerable interaction between biological factors and mechanical factors, creating a biomechanical environment for the fracture healing process. The biomechanical environment is characterized by osteoblasts and osteocytes that sense the mechanical signal and express biological markers, which effect the repair process. This review will focus on the effects of biomechanical factors on fracture repair as well as the effects of age and osteoporosis.

Aged↗

Biocompatibility and osseointegration of beta-TCP: histomorphological and biomechanical studies in a weight-bearing sheep model.

The aim of the study was to investigate the biocompatibility, degradation, and biomechanical properties of beta-TCP (Cerasorb) in a weight-bearing sheep model. beta-TCP implant prototypes were implanted in the tibial head of adult merino sheep. After 6 and 12 months material explants were harvested for biomechanical, histological, and histomorphometrical analysis. Corresponding bone specimens of the intact bone of the contralateral leg were used as controls in the biomechanical test. Compression tests showed higher values for maximum fracture load, yield strength, and compression modulus after 6 and 12 months compared to control. Microscopically, the implants showed good osteoconduction and were incorporated into the bone; however, relevant amounts of beta-TCP were still present after 12 months. Histomorphological results revealed that beta-TCP had partially degraded between implantation and 6 months, but its share remained constant between 6 and 12 months. The bone volume fraction in the area of the implant (46% +/- 6.5%) was initially higher than in the corresponding bone area of the contralateral leg (31% +/- 9.6%), but after 12 months declined to 29% +/- 9.4% (control: 33% +/- 8.3%), while the share of beta-TCP remained constant at 36% +/- 12.2%. These findings were supported by microradiographic data. In conclusion, in a weight bearing implantation model beta-TCP showed good biocompatibility, osseointegration and beginning degradation, even though it was not further degraded between 6 and 12 months.

Animals↗

Effect of constrained posterior screw and rod systems for primary stability: biomechanical in vitro comparison of various instrumentations in a single-level corpectomy model.

Cervical corpectomy is a frequently used technique for a wide variety of spinal disorders. The most commonly used approach is anterior, either with or without plating. The results for single-level corpectomy are better than in multilevel procedures. Nevertheless, hardware- or graft-related complications are observed. In the past, constrained implant systems were developed and showed encouraging stability, especially for posterior screw and rod systems in the lumbar spine. In the cervical spine, few reports about the primary stability of constrained systems exist. Therefore, in the present study we evaluated the primary stability of posterior screw and rod systems, constrained and non-constrained, in comparison with anterior plating and circumferential instrumentations in a non-destructive set-up, by loading six human cadaver cervical spines with pure moments in a spine tester. Range of motion and neutral zone were measured for lateral bending, flexion/extension and axial rotation. The testing sequence consisted of: (1) stable testing; (2) testing after destabilization and cage insertion; (3a) additional non-constrained screw and rod system with lateral mass screws, (3b) with pedicle screws instead of lateral mass screws; (4a) constrained screw and rod system with lateral mass screws, (4b) with pedicle screws instead of lateral mass screws; (5) 360 degrees set-up; (6) anterior plate. The stability of the anterior plate was comparable to that of the non-constrained system, except for lateral bending. The primary stability of the non-constrained system could be enhanced by the use of pedicle screws, in contrast to the constrained system, for which a higher primary stability was still found in axial rotation and flexion/extension. For the constrained system, the achievable higher stability could obviate the need to use pedicle screws in low instabilities. Another benefit could be fewer hardware-related complications, higher fusion rate, larger range of instabilities to be treated by one implant system, less restrictive postoperative treatment and possibly better clinical outcome. From a biomechanical standpoint, in regard to primary stability the constrained systems, therefore, seem to be beneficial. Whether this leads to differences in clinical outcome has to be evaluated in clinical trials.

Aged↗

Mechanical regulation of HB-GAM expression in bone cells.

Bone adaption upon mechanical stimulation is accompanied by changes in gene expression. In this context we investigated the influence of mechanical loading on heparin binding growth associated molecule (HB-GAM) expression, an extracellular matrix molecule which in cell culture has been shown to stimulate the differentiation of osteoblasts. We obtained information on the participating signal transduction pathways using a mitogenic loading regimen. Specific inhibitors of various signal transduction pathways were added to loaded cells and to unloaded controls. By semi-quantitative PCR studies we demonstrated a rapid decrease of HB-GAM expression in primary osteoblasts and SaOs-2 cells by 20-30% upon mechanical loading within 30min. We showed that the RGD-integrin interaction is involved in the regulation of HB-GAM expression. Furthermore, integrity of the cytoskeleton, stretch-activated, and voltage-sensitive Ca(2+) channels as well as gap junctional communication are necessary for the downregulation of HB-GAM expression by mechanical loading.

Aged↗

Influence of screw-cement enhancement on the stability of anterior thoracolumbar fracture stabilization with circumferential instability.

The influence of additional dorsal structure damage on anterior stabilization of a thoracolumbar fracture is still unknown. Screw-cement enhancement can be used to reinforce the stability of anterior instrumentation. We have developed a new anchorage system for fixation of anterior stabilization devices, adapted through geometric optimization and the additional option of cementation after screw insertion. This study examines the question of whether this enhancement is strong enough to enable a single anterior procedure and still compensate for dorsal instability. Various spinal reconstruction procedures were evaluated biomechanically in an increasing ventrodorsal instability model for thoracolumbar fracture stabilization. A biomechanical in vitro study, simulating stabilized defect situations (corporectomy/vertebrectomy) with strut grafting and overbridging instrumentation, was performed on six human T10-L2 cadaveric specimens. The primary stability parameters, range of motion and neutral zone, were evaluated with or without anterior screw-cement enhancement. This was compared with a single conventional anterior stabilization without a dorsal defect (corporectomy). It was also compared with a single anterior, posterior or combined procedure in the presence of additional dorsal structure damage (vertebrectomy). The use of an additional cementable screw dowel enhanced the primary stability of the anterior instrumentation, compensating for dorsal instability. These results are warranted for the clinical use of minimally open or endoscopic techniques, creating the highest possible primary stability while performing a single anterior enhanced instrumentation with a tissue-preserving approach.

Biomechanical Phenomena↗