PubMed Health⌕ Search

Biomedical subjects

Lutz S Freudenberg

Publications and source records attributed to Lutz S Freudenberg.

17 recordsLinked to original sources

Optimizing preoperative imaging in primary hyperparathyroidism.

BACKGROUND: Scintigraphy of the hyperfunctioning parathyroid glands using technetium 99m ((99m)Tc)-methoxyisobutylisonitrile ((99m)Tc-MIBI) is an established and highly sensitive preoperative localization tool whose importance has been further increased by advances in minimally invasive surgery . The goal of the present prospective study was to determine the benefit of optimized imaging in a consistent patient population. METHODS: Eighty-four patients with first presentations of primary hyperparathyroidism were investigated with (99m)Tc-MIBI scintigraphy, thyroid scintigraphy, and cervical ultrasonography. The evaluation algorithm consisted of (a) evaluation of the planar images alone, (b) additional evaluation of single-photon emission computed tomography (SPECT), (c) additional evaluation of thyroid gland scintigraphy, and (d) additional evaluation of ultrasound. All patients subsequently underwent parathyroidectomy. The intraoperative and the histologic findings were correlated with the results of the scintigraphic imaging. RESULTS: The sensitivity of planar parathyroid scintigraphy was 74% and could be increased to 91% by the additional investigations. The difference was statistically significant (p<0.05). At the same time, a small increase in specificity from 96% to 99% was seen. CONCLUSIONS: Prior to minimally invasive treatment of hyperparathyroidism, we recommend combined localization studies consisting of sequential (99m)Tc-MIBI scintigraphy, additional SPECT plus thyroid gland scintigraphy, plus high-resolution cervical ultrasonography.

Adult↗

Positron emission tomography/computed tomography improves diagnostics of inflammatory arteritis.

Based on the unique property of fluorine-18 fluorodeoxyglucose, localization and follow-up of hypermetabolic processes is possible with positron emission tomography (PET). The dual-modality PET/computed tomography (CT) systems provide intrinsically fused morphologic and functional data in a single examination. We report on two patients with inflammatory aortitis and positive PET/CT findings. A 57-year-old woman with an inflammatory process involving the thoracolumbal aorta with an aneurysm and a 48-year-old woman with an aneurysm of the thoracic aorta and pronounced fluorodeoxyglucose-uptake. The advantages in differentiation of vessel wall structures compared with PET or CT alone are pointed out.

Aortic Aneurysm↗

Assessment of liver tissue after radiofrequency ablation: findings with different imaging procedures.

UNLABELLED: Our goal was to assess the typical appearance of normal liver tissue immediately after radiofrequency ablation (RF-ablation) when imaged with contrast-enhanced ultrasound, CT, MRI, 18F-FDG PET, and PET/CT. METHODS: Nineteen RF-ablation sessions were performed on nontumorous liver tissue of 10 Göttingen Mini Pigs. CT, ultrasound, MRI, 18F-FDG PET, and PET/CT were performed immediately after the intervention. All imaging procedures were evaluated qualitatively for areas of increased contrast enhancement (morphologic imaging) and regions of elevated tracer uptake (functional imaging). Images were assessed quantitatively by determination of ratios (r(p/p)) comparing contrast enhancement/tracer uptake in the periphery of the necrosis with contrast enhancement/tracer uptake of normal liver parenchyma. RESULTS: On morphologic imaging, an increase in contrast enhancement surrounding the ablative necrosis was detected in all lesions. Quantification of this area of increased contrast enhancement revealed ratios of r(p/p) = 1.57 +/- 0.2 for CT and r(p/p) = 1.57 +/- 0.19 for MRI. On PET and PET/CT, homogeneous tracer utilization was found surrounding all lesions. There were no areas of a focal or rim-like increase in glucose metabolism. The ratio r(p/p) was found to be 1.05 +/- 0.08 for functional data. Histologic examination revealed pooling of blood in the sinusoids of the lesion's periphery that was caused by outflow obstruction due to the central necrosis. CONCLUSION: On morphologic imaging, a rim-like increase of contrast enhancement was found immediately after RF-ablation resembling peripheral hyperperfusion. This area of contrast enhancement may hamper detection of residual tumor. On the basis of homogeneous tracer distribution surrounding the area of necrosis, PET and PET/CT may serve for early assessment of patients after RF-ablation.

Animals↗

Accuracy of whole-body dual-modality fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT) for tumor staging in solid tumors: comparison with CT and PET.

PURPOSE: To assess the accuracy of positron emission tomography/computed tomography (PET/CT) when staging different malignant diseases. PATIENTS AND METHODS: This was a retrospective, blinded, investigator-initiated study of 260 patients with various oncological diseases who underwent fluorine-18-2-fluoro-2-deoxy-d-glucose PET/CT for tumor staging. CT images alone, PET images alone, PET + CT data viewed side by side, and fused PET/CT images were evaluated separately according to the tumor-node-metastasis system. One hundred forty patients with tumors not staged according to the tumor-node-metastasis system or a lack of reference standard were excluded from data analysis; 260 patients were included. Diagnostic accuracies were determined for each of the four image sets. Histopathology and a clinical follow-up of 311 (+/- 125) days served as standards of reference. RESULTS: PET/CT proved significantly more accurate in assessing tumor-node-metastasis system stage compared with CT alone, PET alone, and side-by-side PET + CT (P < .0001). Of 260 patients, 218 (84%; 95% CI, 79% to 88%) were correctly staged with PET/CT, 197 (76%; 95% CI, 70% to 81%) with side-by-side PET + CT, 163 (63%; 95% CI, 57% to 69%) with CT alone, and 166 (64%; 95% CI, 58% to 70%) with PET alone. Combined PET/CT had an impact on the treatment plan in 16, 39, and 43 patients when compared with PET + CT, CT alone, and PET alone, respectively. CONCLUSION: Tumor staging with PET/CT is significantly more accurate than CT alone, PET alone, and side-by-side PET + CT. This diagnostic advantage translates into treatment plan changes in a substantial number of patients.

Adolescent↗

Acquisition protocol considerations for combined PET/CT imaging.

UNLABELLED: Since its introduction in 1998, dual-modality PET/CT imaging has received great attention in the medical community. For the first time, patients can be examined with both CT and PET in a single examination. A whole-body survey is the standard mode of acquisition. The CT images are used for anatomic reference of the tracer uptake patterns imaged in PET, as well as for attenuation correction of the PET data. The routine use of CT-based attenuation correction and user preferences for the quality and type of the CT examination have led to the introduction of different PET/CT scanning protocols. DISCUSSION: Two general approaches to PET/CT imaging can be distinguished today. One uses CT as a fast transmission source with little additional information for anatomic labeling. The other uses CT as a fast transmission source as well as a state-of-the-art diagnostic tool to maximize image quality using optimal acquisition parameters together with oral and intravenous contrast agents. Variations of these approaches share common concerns about image artifacts that result from mismatches in respiration and patient positioning between the CT and the PET examinations. Protocol requirements for the more complex radiologic PET/CT scenario also include alternative contrast application schemes or modifications to the attenuation correction procedure to handle CT contrast agents appropriately. CONCLUSION: High-quality PET/CT studies can be provided routinely with existing PET/CT technology that is used efficiently by trained and motivated technologists and physicians. Only then will the potential diagnostic benefit of this new imaging modality be explored fully.

Artifacts↗

To enhance or not to enhance? 18F-FDG and CT contrast agents in dual-modality 18F-FDG PET/CT.

UNLABELLED: In combined PET/CT imaging, functional data provided by 18F-FDG increase diagnostic accuracy over conventional PET and CT in a variety of malignancies. The question to be raised is: how much is CT needed in PET/CT imaging? DISCUSSION: In stand-alone CT imaging, contrast agents are applied to aid differentiation of anatomic structures, improve lesion localization, and support lesion characterization. Based on our experience, the most important benefit when applying CT contrast agents in PET/CT imaging relates to more precise anatomic localization of pathology by differentiation of the lesion from its surrounding structures on CT. This benefit must be considered most profound in the head and neck as well as the abdomen and pelvis, where delineation of pathology from muscles, vascular structures, or the intestine is critical. CT contrast agents can be of additional value in tumors with only mild or no increase in 18F-FDG uptake by supporting lesion detection and characterization. The complementary role of CT contrast agents and molecular contrast for PET/CT imaging is addressed in this review. The authors provide specific indications as to which contrast-enhanced CT data provide additional diagnostic value. CONCLUSION: Functional contrast aids lesion detection and characterization, whereas morphologic contrast improves lesion localization. CT contrast agents and PET tracers do not compete but rather are complementary in combined PET/CT imaging.

Contrast Media↗

Comparison of PET, CT, and dual-modality PET/CT imaging for monitoring of imatinib (STI571) therapy in patients with gastrointestinal stromal tumors.

UNLABELLED: This study was implemented to compare the value of PET, CT, and dual-modality PET/CT imaging for assessing gastrointestinal stromal tumor (GIST) response to imatinib therapy. METHODS: Twenty patients with histologically proven GIST underwent (18)F-FDG PET/CT imaging before and 1, 3, and 6 mo after the start of imatinib therapy. Separate PET and CT datasets, side-by-side PET and CT datasets, and fused PET/CT images were evaluated according to World Health Organization, Response Evaluation Criteria in Solid Tumors, and European Organisation for Research and Treatment of Cancer criteria for therapy response. Hounsfield units (HU) were assessed on CT images. A mean follow-up period of 381 +/- 134 d served as the standard of reference. RESULTS: The numbers of lesions detected in all patients were 135 with PET, 249 with CT, 279 on side-by-side evaluation, and 282 on fused PET/CT images. Tumor response was correctly characterized in 95% of patients after 1 mo and 100% after 3 and 6 mo with PET/CT. PET and CT images viewed side by side were correct in 90% of patients at 1 mo and 100% at 3 and 6 mo. PET accurately diagnosed tumor response in 85% of patients at 1 mo and 100% at 3 and 6 mo. CT was found to be accurate in 44% of patients at 1 mo, 60% at 3 mo, and 57% at 6 mo. HU were found to decrease by at least 25% in 12 of 14 responders after 1 mo. CONCLUSION: Tumor response to imatinib should be assessed with a combination of morphologic and functional imaging. Image fusion with combined PET/CT can provide additional information in individual cases when compared with side-by-side PET and CT.

Adult↗

Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology.

CONTEXT: Deciding on the appropriate therapy for patients with malignant diseases mandates accurate tumor staging with whole-body coverage. Magnetic resonance imaging (MRI) and a combined modality including positron emission tomography (PET) and computed tomography (CT) provide whole-body tumor staging in a single session. OBJECTIVE: To determine the staging accuracies of both whole-body PET/CT and whole-body MRI for different malignant diseases. DESIGN, SETTING, AND PATIENTS: Prospective, blinded, investigator-initiated study of 98 patients (mean age, 58 years; range, 27-94 years) with various oncological diseases who underwent back-to-back whole-body glucose analog [18F]-fluorodeoxyglucose-PET/CT and whole-body MRI for tumor staging. The study was conducted at a university hospital from December 2001 through October 2002 and had a mean follow-up of 273 days (range, 75-515 days). The images were evaluated by 2 different, blinded reader teams. The diagnostic accuracies of the 2 imaging procedures were compared. MAIN OUTCOME MEASURES: Correct classification of the primary tumor, regional lymph nodes, and distant metastasis (overall TNM stage) using whole-body PET/CT and whole-body MRI. Secondary outcome measures were accurate assessment of T-stage, N-stage, and M-stage by the 2 imaging procedures. RESULTS: Of 98 patients, the overall TNM stage was correctly determined in 75 with PET/CT (77%; 95% confidence interval [CI], 67%-85%) and in 53 with MRI (54%; 95% CI, 44%-64%) (P<.001). Compared with MRI, PET/CT had a direct impact on patient management in 12 patients. Results from MRI changed the therapy regimen in 2 patients compared with PET/CT. Separate assessment of T-stage (with pathological verification) in 46 patients revealed PET/CT to be accurate in 37 (80%; 95% CI, 66%-91%) and MRI to be accurate in 24 (52%; 95% CI, 37%-67%) (P<.001). Of 98 patients, N-stage was correctly determined in 91 patients with PET/CT (93%; 95% CI, 86%-97%) and in 77 patients with MRI (79%; 95% CI, 69%-86%) (P =.001). Both imaging procedures showed a similar performance in detecting distant metastases. CONCLUSIONS: The feasibility and diagnostic accuracy of the whole-body staging strategies of PET/CT and MRI are established. Superior performance in overall TNM staging suggests the use of [18F]-fluorodeoxyglucose-PET/CT as a possible first-line modality for whole-body tumor staging.

Adult↗

Non-small cell lung cancer: dual-modality PET/CT in preoperative staging.

PURPOSE: To determine the accuracy of dual-modality positron emission tomographic (PET)-computed tomographic (CT) imaging, as compared with PET alone and CT alone, in the staging of non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: Twenty-seven patients with NSCLC underwent staging with combined fluorine 18 fluorodeoxyglucose PET and CT. CT, PET, and coregistered PET/CT images were evaluated separately by two different physicians for each imaging modality, and disease stage was determined by using TNM and American Joint Committee on Cancer staging systems. Histopathologic results served as the reference standard. The statistical significance of differences among CT, PET, and PET/CT was determined by using the McNemar test. RESULTS: Overall tumor stage was correctly classified as 0-IV with CT in 19 patients, with PET in 20 patients, and with PET/CT in 26 patients. PET/CT findings when compared with PET findings led to a treatment change for four patients (15%) and when compared with CT findings led to a treatment change for five patients (19%). Differences in the accuracy of overall tumor staging between PET/CT and CT (P =.008) and between PET/CT and PET (P =.031) were significant. Primary tumor stage was correctly determined in more patients with PET/CT than with either PET alone or CT alone. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging, respectively, were 89%, 94%, 89%, 94%, and 93%, with PET/CT; 89%, 89%, 80%, 94%, and 89% with PET; and 70%, 59%, 50%, 77%, and 63% with CT. Fourteen distant metastases were detected in four patients with CT, four were detected in two patients with PET, and 17 were detected in four patients with PET/CT. CONCLUSION: Use of dual-modality PET/CT significantly increases the number of patients with correctly staged NSCLC and thus has a positive effect on treatment.

Adult↗

Effect of oral contrast agents on computed tomography-based positron emission tomography attenuation correction in dual-modality positron emission tomography/computed tomography imaging.

RATIONALE AND OBJECTIVES: To evaluate the effect of iodine- and barium-based contrast agents on the computed tomography (CT)-based positron emission tomography (PET) attenuation correction in dual-modality PET/CT. METHODS: Experiments were conducted on a Society of Nuclear Medicine/National Electrical Manufacturers Association-PET phantom equipped with cylinders containing [18F]-2-fluoro-2-desoxy-D-glucose. The main compartment was filled with iodine (0.5-10%), barium (0.5-50%), or water (negative control). The error in attenuation correction was determined by comparison of measured tracer quantities in the presence of contrast agents with expected quantities. Contrast agent attenuation was demonstrated to be comparable to in vivo conditions. RESULTS: The presence of contrast agents resulted in an overestimation of the intracylindrical activity concentration on PET images and overestimation directly related to contrast concentrations (iodine 5-38%; barium 15-580%). Iodine and barium concentrations in clinical use resulted in an activity overestimation of 20 +/- 1.8% for iodine and 21 +/- 2.9% for barium. CONCLUSION: An overestimation of the tracer activity concentration is to be expected in the presence of oral contrast agents, if PET attenuation correction is attained CT-based.

Administration, Oral↗

Whole-body MRI using a rolling table platform for the detection of bone metastases.

The aim of this study was to compare the results of whole-body MRI using a recently developed rolling table platform with findings of nuclear scintigraphy in patients with bone metastases. Twenty-six patients with known or suspected bone metastases who had undergone radionuclide scintigraphy were examined by MRI. Patients were placed on a rolling table platform with integrated phased-array surface coils [BodySURF (system for unlimited field of view)] capable of pulling the patient through the isocenter of the magnet. Using a five-station approach three different image sets (T1-weighted gradient recalled echo, half-Fourier acquired single-shot turbo spin echo, and short tau inversion recovery) were collected in the coronal plane. In addition, the spine was imaged in the sagittal plane. The MRI findings were compared with the results obtained by scintigraphy. The whole-body MR examination lasting merely 40 min was feasible in all 26 patients. The MRI revealed excellent correlation with scintigraphy regarding metastatic lesions. A total of 60 regions with metastatic lesions were identified on bone scintigraphy. Fifty-three regions were detected on identical locations by MRI. The regions missed by MRI were located mainly in ribs and skull. The MRI could identify additional bone metastases in spine, pelvis, and femur. The MRI screening for bone metastases correlated well with bone scintigraphy. Use of the rolling table platform permits rapid imaging based on three different contrast mechanisms of the entire skeletal system.

Adult↗

Whole-body positron emission tomography-CT: optimized CT using oral and IV contrast materials.

OBJECTIVE: Our objective was to show that oral and IV contrast materials improve CT image quality in dual-modality positron emission tomography (PET) and CT, resulting in an increase in diagnostic capacity. We also present a standardized scanning protocol for whole-body PET-CT with oral and IV contrast materials. SUBJECTS AND METHODS: To evaluate the use of whole-body PET-CT in clinical practice, we examined 30 patients according to the protocol. The CT images were evaluated quantitatively by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) analyses and qualitatively by two radiologists in consensus. PET quality was assessed quantitatively by measurements of standard uptake values that were compared with standard uptake values in 10 PET-CT examinations without contrast agents. RESULTS: . The application of oral and IV contrast materials led to a highly sufficient delineation of vascular and intestinal structures in 26 of 30 patients. Quantitative analysis revealed a mean vascular SNR of 15.8 +/- 7.71 for the 30 patients who received contrast materials compared with 4.79 +/- 1.45 for the 10 control group patients (p < 0.001). Similarly, the mean intestinal SNR of 17.06 +/- 7.96 far exceeded that seen in the control group of 3.83 +/- 1.16 (p < 0.001). Analyses led to a vessel-to-muscle CNR of 10.78 +/- 5.89 (control group, -1.21 +/- 0.89; p < 0.001) and an intestine-to-muscle CNR of 12.04 +/- 6.07 (control group, -2.17 +/- 1.22; p = 0.001) in the 30 patients. An evaluation of PET quality in patients who received contrast materials showed a mean standard uptake value of 2.09 +/- 1.16 compared with 2.04 +/- 0.83 in the control group (p = 0.702). CONCLUSION: Our whole-body PET-CT protocol provided good vascular and intestinal enhancement without compromising PET quality, leading to a potential improvement in the diagnostic capacity of the combined PET-CT examination.

Administration, Oral↗

Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans.

UNLABELLED: This study was performed to evaluate a possible artifact related to the administration of intravascular contrast agent in dual-modality PET/CT imaging. METHODS: Thirty oncology patients underwent whole-body PET/CT. CT images, which were collected in the presence of intravenous and oral iodinated contrast agent, were used for PET attenuation correction. PET images were assessed for the artifact, defined as a region of high count rate on attenuation-corrected images in accurate coregistration with a contrast-enhanced blood vessel. Intravascular enhancement of thoracic veins was quantified by application of regions of interest, and quantities in patients with the artifact (group 1) and without the artifact (group 2) were correlated. Body surface area was calculated for all patients. RESULTS: The contrast-induced PET artifact was present in 4 (13%) of 30 patients. Mean density differences in intravascular enhancement were highly significant (P < 0.001) in a comparison of group 1 (2,262 +/- 304 Hounsfield units [HU]) and group 2 (1,058 +/- 209 HU). Body surface area was significantly lower (P = 0.035) in the patients of group 1 (1.67 +/- 0.11 m(2)) than in the patients of group 2 (2.01 +/- 0.18 m(2)). CONCLUSION: Contrast-enhanced dual-modality PET/CT examinations may result in a PET artifact that is due to the transient bolus passage of undiluted intravenous contrast agent.

Artifacts↗

Positron emission tomography/computed tomography--imaging protocols, artifacts, and pitfalls.

There has been a longstanding interest in fused images of anatomical information, such as that provided by computed tomography (CT) or magnetic resonance imaging (MRI) systems, with biological information obtainable by positron emission tomography (PET). The near-simultaneous data acquisition in a fixed combination of a PET and a CT scanner in a combined PET/CT imaging system minimizes spatial and temporal mismatches between the modalities by eliminating the need to move the patient in between exams. In addition, using the fast CT scan for PET attenuation correction, the duration of the examination is significantly reduced compared to standalone PET imaging with standard rod-transmission sources. The main source of artifacts arises from the use of the CT-data for scatter and attenuation correction of the PET images. Today, CT reconstruction algorithms cannot account for the presence of metal implants, such as dental fillings or prostheses, properly, thus resulting in streak artifacts, which are propagated into the PET image by the attenuation correction. The transformation of attenuation coefficients at X-ray energies to those at 511 keV works well for soft tissues, bone, and air, but again is insufficient for dense CT contrast agents, such as iodine or barium. Finally, mismatches, for example, due to uncoordinated respiration result in incorrect attenuation-corrected PET images. These artifacts, however, can be minimized or avoided prospectively by careful acquisition protocol considerations. In doubt, the uncorrected images almost always allow discrimination between true and artificial finding. PET/CT has to be integrated into the diagnostic workflow for harvesting the full potential of the new modality. In particular, the diagnostic power of both, the CT and the PET within the combination must not be underestimated. By combining multiple diagnostic studies within a single examination, significant logistic advantages can be expected if the combined PET/CT examination is to replace separate state-of-the-art PET and CT exams, thus resulting in significantly accelerated diagnostics.

Humans↗

Dual modality of 18F-fluorodeoxyglucose-positron emission tomography/computed tomography in patients with cervical carcinoma of unknown primary.

OBJECTIVE: To evaluate an optimized F-18-flurodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) acquisition protocol for head and neck cancer and assess the usefulness of combined FDG-PET/CT in locating unknown primary tumors in patients with biopsy-proven cervical lymph node metastases. SUBJECTS AND METHODS: Twenty-one patients with cervical lymph node metastases of unknown primary tumors underwent staging with FDG-PET/CT. The images of FDG-PET alone, CT alone, FDG-PET/CT read side by side and fused and FDG-PET/CT were evaluated separately by 2 physicians. Imaging results were correlated with either histology (n = 14) or clinical follow-up (n = 7). RESULTS: On the fused FDG-PET/CT images, primary tumors were identified in 12 patients (57%); with FDG-PET alone and FDG-PET and CT read side by side 11 (52%) primary tumors were found while CT alone identified 5 (23%) primary tumors. CONCLUSION: Our data indicate that fused FDG-PET and CT images increased the sensitivity of detecting carcinoma of unknown primary (CUP) tumors compared to CT alone, but not to FDG-PET alone or FDG-PET and CT read side by side. Hence accurate fusion of functional and morphologic data by FDG-PET/CT is a promising imaging modality in the clinical workup of patients with cervical CUP tumors.

Aged↗