PubMed Health⌕ Search

Biomedical subjects

Lutz Tellmann

Publications and source records attributed to Lutz Tellmann.

11 recordsLinked to original sources

Concepts of registration and correction of head motion in positron emission tomography.

The long acquisition times (up to hours) in PET brain imaging bear a high risk of head motion, which results in artefacts like blurred images and may even lead to misinterpretation and useless data. With the increased resolution of high performance PET scanners, the influence of head movements becomes more and more relevant. Especially in the analysis of small brain structures, e.g. during ROI-analysis, head motion results in inaccuracies of quantified data. This may also influence the kinetic analysis and generate artifacts in parametric images calculated from a motion-affected image sequence. This work presents the feasibility of head motion registration using an external motion tracking system. The implementation of the multi acquisition frame method and an event-by-event method to correct PET data for motion are described. The effects of motion correction are demonstrated on the basis of phantom measurements and patient data. The influence of motion correction on parametric imaging is described in a receptor study.

Artifacts↗

PET with O-(2-18F-Fluoroethyl)-L-Tyrosine in peripheral tumors: first clinical results.

UNLABELLED: O-(2-18F-Fluoroethyl)-L-Tyrosine (18F-FET) PET has shown promising results in brain tumor diagnosis. The aim of this prospective study was to evaluate 18F-FET PET in comparison with 18F-FDG PET in patients with peripheral tumors. METHODS: Forty-four consecutive patients with suspected malignant tumors underwent 18F-FET PET and 18F-FDG PET within 7 d. Whole-body PET studies were performed 1 h after intravenous injection of 370 MBq of 18F-FET or 18F-FDG. Six patients were excluded from the analysis because a malignant tumor could not be verified. In 38 patients (7 with colorectal cancer, 6 with pancreatic cancer, 9 with head-neck cancer, 4 with lymphomas, 3 with lung cancer, 3 with ovarian cancer, 4 with breast cancer, and 2 with prostatic cancer), 18F-FET PET and 18F-FDG PET were compared. RESULTS: 18F-FET was positive in only 13 of 38 patients (8 with head-neck cancer, 3 with breast cancer, and 2 with lung cancer), whereas 18F-FDG exhibited increased uptake in 37 of 38 patients. All squamous cell carcinomas were found to be 18F-FET-positive tumors (8 head-neck cancer and 2 lung cancer), whereas most adenocarcinomas were found to be 18F-FET-negative tumors. In patients with colorectal cancer, pancreatic cancer, ovarian cancer, prostatic cancer, and lymphomas, no increased 18F-FET uptake could be identified. All lesions that exhibited increased 18F-FET uptake also showed increased 18F-FDG uptake. No additional lesion was identified by 18F-FET PET but not by 18F-FDG PET. A subgroup analysis of patients with head-neck carcinomas allowed a better distinction between malignant and inflammatory tissues with 18F-FET than with 18F-FDG. CONCLUSION: 18F-FET is inferior to 18F-FDG as a PET tracer for general tumor diagnosis. Our preliminary results suggest rather selective uptake of 18F-FET in squamous cell carcinomas. Compared with 18F-FDG PET, 18F-FET PET may allow a better distinction between tumors and inflammatory tissues in patients with squamous cell carcinomas.

Adult↗

On the use of positioning aids to reduce misregistration in the head and neck in whole-body PET/CT studies.

UNLABELLED: Involuntary patient motion from insufficient patient preparation may lead to local misregistration of PET/CT images and, thus, can invalidate the attempt to fuse the resulting images. We estimate the efficacy of selected patient support structures in reducing the likelihood of patient motion in the area of the head and neck during whole-body PET/CT studies. METHODS: Motion of the head and neck was estimated in 51 healthy volunteers during simulated whole-body PET/CT studies using an infrared camera-based tracking system. Four patient positioning schemes (arms down) were studied, with the neck placed on a standard PET head holder with no support at the sides (setup A), on a special head holder fitted with a subject-specific mold from construction foam (setup B), on a vacuum-lock bag (setup C), and on a special head holder fitted with a vacuum-lock bag (setup D). We report the average motion of the head and neck as the difference in the position of a set of target points between the simulated CT image and PET image of the head and neck. To estimate the efficacy of additional patient support measures in clinical practice, we reviewed the misregistration of the head and neck in whole-body PET/CT studies of 10 patients each who were imaged using setups A and C by comparing the mean translational and rotational alignment parameters from a semiautomatic linear registration approach needed to realign the CT and PET images. RESULTS: Average translational and rotational misalignment of the head and neck was highest for setup A, at 7 mm and 1 degrees , respectively. Misalignment was reduced to a minimum of 1.4 mm and 0.3 degrees for setup D. Setup B resulted in a similar reduction in patient motion of the head and neck: 2.4 mm and 0.4 degrees , whereas setup C provided only somewhat improved support, with a resulting average misalignment of 4.5 mm and 0.7 degrees. In clinical PET/CT, we found setup C to reduce translational misalignment of the CT and PET images of the head and neck to 2 mm, compared with 6 mm for setup A, whereas no significant reduction of rotational misalignment was observed. CONCLUSION: Average motion of the head and neck in unrestrained subjects during whole-body PET/CT examinations can be reduced by use of rigid positioning aids, such as foam molds, or vacuum-lock bags. Vacuum-lock bags are reusable, quickly adaptable, and olfactory neutral and can be used routinely, either alone or in combination with a head holder, in whole-body PET/CT for high-quality examinations.

Equipment Failure Analysis↗

Motion artifact reduction on parametric PET images of neuroreceptor binding.

UNLABELLED: PET studies of cerebral neuroreceptors are often recorded over periods ranging from 1 to 2 h, and head movements during the studies not only lead to blurred images but also may seriously disturb the kinetic analysis. We report the effect of motion on parametric images of the distribution volume ratio (DVR), as well as possible improvements if the dynamic PET data are corrected for head movements. METHODS: The study was performed with the 5-hydroxytryptamine 2A receptor ligand (18)F-altanserin. During PET scanning, which was performed in list mode for 1 h, the position of the head was monitored by an infrared motion-tracking system. The list mode data were sorted into time frames of between 10 s and 2 min. Motion was corrected using the multiple-acquisition-frame (MAF) approach, which calculates individual attenuation files for each emission frame and its corresponding head position to avoid misalignment of transmission and emission data. After reconstruction of attenuation-corrected emission frames, each image frame was realigned to match the head position of the first frame of the emission scan. The resulting motion-corrected dynamic images were evaluated using the noninvasive Logan plot to obtain parametric images of DVR. RESULTS: DVR images of motion-affected (18)F-altanserin scans showed artifacts whose extent depended on the amount of movement. The artifacts were mainly at the border between gray matter and white matter and at the outer border of gray matter. They were seen as discontinuities and small spots whose values exceeded the expected DVR values or were even negative and that disappeared when motion correction was applied. These effects in human data were also seen on simulated (18)F-altanserin images that contained no statistical noise. CONCLUSION: Whereas the native PET images looked just blurred if the patient moved during the PET scan, parametric images of the Logan DVR, which are calculated by pixelwise linear regression, contained severe discontinuities primarily at the cortical edge. MAF-based motion correction was able to avoid these errors.

Artifacts↗

Neural mechanisms underlying reaching for remembered targets cued kinesthetically or visually in left or right hemispace.

Reaching for a target involves integrative coordinate transformation processes between the representation of the target location, the sensorimotor information of limb of reach, and body space. Although right hemisphere dominance for visuospatial information processing is well established, corresponding right hemisphere dominance for kinesthetic spatial information processing remains to be demonstrated. We explored neural mechanisms of encoding target locations using 15O-butanol positron emission tomography (PET) in normal volunteers in a factorial experiment, where modality (visual/kinesthetic) and hemispace of target presentation (left/right of midsagittal plane) were varied systematically. After target presentation, subjects reached to the encoded target location. PET data analysis using SPM99 showed increased neural activity (P < 0.05, corrected) associated with left hemispace target presentation in right hemisphere areas (sensorimotor, anterior cingulate, insular, and temporo-occipital cortex) only. By contrast, right hemispace target presentation activated bilateral temporo-occipital cortex, which extended into the right temporo-parietal cortex and left sensorimotor cortex. A significant interaction of hemispace and modality of target presentation observed in right temporo-parietal cortex resulted from an increase in neural activity with kinesthetic target presentation in right hemispace. The data support an important role for the right temporo-parietal area in visuospatial processing and suggest a specific role of the right hemisphere in kinesthetic spatial processing.

Adult↗

Comparison of O-(2-18F-fluoroethyl)-L-tyrosine PET and 3-123I-iodo-alpha-methyl-L-tyrosine SPECT in brain tumors.

UNLABELLED: The aim of this study was to compare PET with O-(2-(18)F-fluoroethyl)-L-tyrosine ((18)F-FET) and SPECT with 3-(123)I-iodo-alpha-methyl- L-tyrosine ((123)I-IMT) in patients with brain tumors. METHODS: Twenty patients with a suspected brain tumor were investigated by (18)F-FET PET, (123)I-IMT SPECT, and MRI within 3 wk. Region-of-interest analyses were performed on coregistered PET/SPECT/MRI images and the tumor-to-brain ratio (TBR), muscle-to-brain ratio (MBR), cerebellum-to-brain ratio (CerBR), and sinus-to-brain ratio (SBR) were calculated. In addition, the presence of tumor and the discrimination of anatomic structures on (18)F-FET PET and (123)I-IMT SPECT images were visually determined by 3 observers who were unaware of clinical data. RESULTS: The TBR of (18)F-FET and (123)I-IMT uptake in cerebral tumors showed a highly significant correlation (r = 0.96; P < 0.001). In the visual analysis for the presence or absence of tumors, no differences for (123)I-IMT SPECT and (18)F-FET PET were found in 19 of 20 patients; in one patient a low-grade glioma was only identified on (18)F-FET PET images but not on (123)I-IMT SPECT images. The contrast between tumor and normal brain was significantly higher in (18)F-FET PET (TBR, 2.0 +/- 0.9) than in (123)I-IMT SPECT (TBR, 1.5 +/- 0.5). The discrimination of anatomic structures yielded a significantly better score on (18)F-FET PET images (rating score, 2.6 +/- 0.9) compared with (123)I-IMT SPECT images (rating score, 1.7 +/- 0.9). The uptake of (18)F-FET in the muscles was significantly higher compared with (123)I-IMT (MBR (18)F-FET, 1.4 +/- 0.3; MBR (123)I-IMT, 0.6 +/- 0.2; P < 0.001) and (18)F-FET demonstrated a significantly higher blood-pool radioactivity than (123)I-IMT (SBR (18)F-FET, 1.3 +/- 0.2; SBR (123)I-IMT, 0.8 +/- 0.2; P < 0.001). CONCLUSION: The significant correlation of the TBRs of (18)F-FET and (123)I-IMT indicates that clinical experiences of brain tumor diagnostics with (123)I-IMT SPECT might be valid for (18)F-FET PET although substantial differences of the physiologic behavior were identified in extracerebral tissue. As (18)F-FET PET allows improved discrimination of anatomic structures and the tumor-to-brain contrast was significantly superior compared with (123)I-IMT SPECT scans, the results are encouraging for further evaluation of (18)F-FET for imaging brain tumors.

Adult↗

Lexical decision of nonwords and pseudowords in humans: a positron emission tomography study.

In this functional positron emission tomography study brain activations during an auditory lexical decision task with two experimental conditions were investigated. First, the subjects had to discriminate between real words and nonwords; second, real words varied with pseudowords. Comparing each of these tasks to an auditory control condition we found bilateral activation of the superior temporal and inferior frontal gyrus, lateralized to the left in the pseudoword condition. The comparison of the lexical decision tasks revealed higher rCBF during the pseudo-/real word decisions within BA 47, adjacent to Broca's area, and the anterior cingulate. The data support the notion that the lexical decision during a nonword task is mainly based on a phonological discrimination process, whereas a pseudoword task more strongly requires lexical access resulting in activation of BA 47.

Acoustic Stimulation↗

Whole-body distribution and dosimetry of O-(2-[18F]fluoroethyl)-L-tyrosine.

The whole-body distribution of O-(2-[(18)F]fluoroethyl)- l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV </=1.6) which remained constant between early and late PET scans. No increased uptake was seen in the bone, the biliary tract or the pancreas. Twenty-two percent of the injected activity was excreted 5 h p.i. (approx. 5.3% ID/h). The highest absorbed dose was found for the urinary bladder wall. The effective dose according to ICRP 60 was 16.5 micro Sv/MBq for adults, which would lead to an effective dose of 6.1 mSv in a PET study using 370 MBq FET.

Adult↗

Hemispheric dissociation of visual-pattern processing and visual rotation.

We aimed at investigating whether on-line and delayed visual pattern processing activated different areas in human prefrontal and parietal cortex. For this purpose we measured the regional cerebral blood flow (rCBF) during simultaneous and successive visual matrix processing in 10 right-handed subjects. Delayed matching to sample activated predominantly left hemispheric ventrolateral prefrontal cortex, Broca's area and parts of the parietal cortex. In contrast, visuospatial matrix rotation showed activation of the right dorsolateral prefrontal cortex and parietal lobe. The present results suggest a hemispheric dissociation of fronto-parietal circuits with a left dominance for visual pattern processing like storage and a right dominance for visuospatial processing.

Adult↗

Neural correlates of visuospatial imagery.

We studied changes in regional cerebral blood flow (rCBF) in 10 healthy right-handed subjects during a visuospatial imagery task. The subject's task consisted of drawing imagined lines connecting encircled numbers in ascending order and estimating the number of lines crossing. Compared with a control task in which there were no crossed lines, there were significant rCBF increases in the cingulate gyrus, the adjacent superior frontal gyrus and in the left inferior parietal cortex. The rCBF changes of the latter area correlated with task performance time. Since these activation areas are close to those in imagery of movement trajectories, we concluded that they appear to be a subsystem for processing mental visuospatial images.

Adult↗