Volumetric analysis of regional left ventricular function with real-time three-dimensional echocardiography: validation by magnetic resonance and clinical utility testing.

BACKGROUND: Quantitative information on regional left ventricular volumes from real-time three-dimensional echocardiographic (RT3DE) images has significant clinical potential but needs validation. AIM: To validate these measurements against cardiac magnetic resonance (CMR) and test the feasibility of automated detection of regional wall motion (RWM) abnormalities from RT3DE data. METHODS: RT3DE (Philips) and CMR (Siemens) images were obtained from 31 patients and analysed by using prototype software to semiautomatically calculate indices of regional left ventricular function, which were compared between RT3DE and CMR (linear regression, Bland-Altman). Additionally, CMR images were reviewed by an expert, whose RWM grades were used as a reference for automated classification of segments as normal or abnormal from RT3DE and from CMR images. For each modality, normal regional ejection fraction (REF) values were obtained from 15 patients with normal wall motion. In the remaining 16 patients, REFs were compared with thresholds that were derived from patients with normal wall motion and optimised using receiver operating characteristic analysis. RESULTS: RT3DE measurements resulted in good agreement with CMR. Regional indices calculated in patients with normal wall motion varied between segments, but overall were similar between modalities. In patients with abnormal wall motion, RWM was graded as abnormal in 74% segments. CMR and RT3DE thresholds were similar (16-segment average 55 (10)% and 56 (7)%, respectively). Automated interpretation resulted in good agreement with expert interpretation, similar for CMR and RT3DE (sensitivity 0.85, 0.84; specificity 0.81, 0.78; accuracy 0.84, 0.84, respectively). CONCLUSION: Analysis of RT3DE data provides accurate quantification of regional left ventricular function and allows semiautomated detection of RWM abnormalities, which is as accurate as the same algorithm applied to CMR images.

Algorithms↗

Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference.

BACKGROUND: Cardiac CT (CCT) and real-time 3D echocardiography (RT3DE) are being used increasingly in clinical cardiology. CCT offers superb spatial and contrast resolution, resulting in excellent endocardial definition. RT3DE has the advantages of low cost, portability, and live 3D imaging without offline reconstruction. We sought to compare both CCT and RT3DE measurements of left ventricular size and function with the standard reference technique, cardiac MR (CMR). METHODS AND RESULTS: In 31 patients, RT3DE data sets (Philips 7500) and long-axis CMR (Siemens, 1.5 T) and CCT (Toshiba, 16-slice MDCT) images were obtained on the same day without beta-blockers. All images were analyzed to obtain end-systolic and end-diastolic volumes and ejection fractions using the same rotational analysis to eliminate possible analysis-related differences. Intertechnique agreement was tested through linear regression and Bland-Altman analyses. Repeated measurements were performed to determine intraobserver and interobserver variability. Both CCT and RT3DE measurements resulted in high correlation (r2 > 0.85) compared with CMR. However, CCT significantly overestimated end-diastolic and end-systolic volumes (26 and 19 mL; P < 0.05), resulting in a small but significant bias in ejection fraction (-2.8%). RT3DE underestimated end-diastolic and end-systolic volumes only slightly (5 and 6 mL), with no significant bias in EF (0.3%; P = 0.68). The limits of agreement with CMR were comparable for the 2 techniques. The variability in the CCT measurements was roughly half of that in either RT3DE or CMR values. CONCLUSIONS: CCT provides highly reproducible measurements of left ventricular volumes, which are significantly larger than CMR values. RT3DE measurements compared more favorably with the CMR reference, albeit with higher variability.

Aged↗

Color encoding of endocardial motion improves the interpretation of contrast-enhanced echocardiographic stress tests by less-experienced readers.

BACKGROUND: We hypothesized that color encoding of endocardial motion could aid less-experienced readers in detection of wall-motion abnormalities at rest and stress in patients with poor acoustic windows. METHODS: Color-encoded images (color kinesis) were obtained at rest and peak dobutamine stress in 4 standard views during intravenous infusion of contrast agent in 117 patients with poorly visualized endocardium. In 101 of 117 patients (86%), in whom contrast enhancement allowed endocardial tracking, images were reviewed by two expert readers without color overlays. Each reader graded regional wall motion as normal, abnormal, or uninterpretable, and their consensus grades served as a gold standard. The same images were then reviewed and graded with and without color overlays by 3 cardiology fellows. The accuracy of the interpretation was calculated against the gold standard separately for the 3 vascular territories (left anterior descending, left circumflex, and right coronary arteries) and averaged for the 3 fellows. RESULTS: With the addition of color encoding: (1) the number of uninterpretable segments decreased by 55% at rest and 61% at peak stress; and (2) all 3 fellows reached higher levels of accuracy in all 3 vascular territories both at rest (6%-82% average) and at stress (73%-80%). CONCLUSION: The addition of color encoding of wall motion to contrast-enhanced images obtained in patients with poor acoustic windows during stress tests improves the interpretation of regional left ventricular function by less-experienced readers.

Dobutamine↗

Comparison of contrast-enhanced real-time live 3-dimensional dobutamine stress echocardiography with contrast 2-dimensional echocardiography for detecting stress-induced wall-motion abnormalities.

BACKGROUND: Two-dimensional (2D) contrast-enhanced dobutamine stress echocardiography (DSE) is used clinically to diagnose stress-induced wall-motion abnormality (WMA). We hypothesized that contrast-enhanced real-time 3-dimensional (3D) DSE could improve the detection rate of WMA, because from a single full-volume acquisition, multiple segments can be visualized. METHODS: We acquired both 2D and 3D DSE in 78 patients with known or suggested coronary artery disease (mean age: 65 years; 44 men). Dobutamine was infused using a standard protocol, and atropine added, if required. For 2D DSE, the intravenous contrast agent was injected at each stage and images displayed in a quadscreen format. For 3D DSE, contrast harmonic 3D data sets (full volumes) were acquired at baseline and peak stress. Using custom software, 3 short-axis views (from apex to base) were created, and wall motion scored using a wall-motion score index using a 16-segment model. A positive stress test was defined as new or worsened WMA or fixed abnormality during stress. RESULTS: Heart rate increased from 72 +/- 13 to 133 +/- 15/min (86 +/- 11% of age-predicted). A total of 1248 segments were analyzed at each stage for both modalities. A single segment at baseline and 5 segments at peak stress could not be assessed with contrast 2D DSE. In contrast, 88 segments at baseline and 39 segments at peak stress could not be assessed with contrast 3D DSE. With 3D DSE, the majority of uninterpretable segments were in the anterior and lateral walls. Significant correlations were noted between wall-motion score index by 2D and 3D DSE at baseline (r = 0.78) and peak stress (r = 0.83). The concordance rate (positive/negative findings) between modalities was 69% (54/78) on a patient basis and 88% (206/234) on a perfusion territory basis. When using 2D DSE results as the gold standard, sensitivity and specificity for detecting WMA by 3D DSE was 58% and 75%, respectively. Sensitivity and specificity values were 67% and 94% for the right coronary artery, 53% and 81% for the left anterior descending coronary artery, and 88% and 100% for the left circumflex coronary artery territory, respectively. CONCLUSION: Contrast-enhanced 3D DSE was feasible in the majority of patients. However, the moderate concordance between both modalities was a result of: (1) difficulties in visualizing the anterolateral segments because of the relatively large imprint of the transducer; and (2) lower frame rates with 3D DSE resulting in the erroneous diagnosis of dyssynchrony.

Aged↗

Use of real-time 3-dimensional transthoracic echocardiography in the evaluation of mitral valve disease.

Three-dimensional (3D) echocardiography (3DE) provides unique orientations of the mitral valve (MV) not obtainable by routine 2-dimensional echocardiography. However, this modality has not been adopted in routine clinical practice because of its cumbersome and time-consuming process. The recent introduction of a full matrix-array transducer has enabled online real-time 3DE (RT3DE) and rendering. This study was designed to: (1) determine the clinical use of RT3DE in patients with MV pathology and in a control group selected for their good acoustic windows (protocol I); and (2) to investigate the feasibility of imaging the MV apparatus in a large group of consecutively imaged patients to determine the acoustic window or perspective from which the MV leaflets, commissures, and orifice are best visualized (protocol II). In protocol I, 65 patients were selected based on MV pathology and good 2-dimensional echocardiography image quality. Protocol II included 150 patients who were consecutively imaged using RT3DE. Images were viewed online (protocol I) and offline on a digital review station (protocol II). RT3DE visualization of the MV apparatus was graded based on the percentage of leaflet dropout and definition. In protocol I, 78% of patients had adequate 3D MV reconstructions with complete visualization of the anterior mitral leaflet (AML) in 84% versus the posterior mitral leaflet (PML) in 77%. The mitral leaflets, commissures, and MV orifice were well seen in 98%; however, the submitral apparatus was only observed in 76% of the patients. RT3DE: (1) correctly identified the prolapsed/flailed scallop in 6 of 8 patients; (2) obtained en face orientation of the MV orifice in 9 of 11 patients with mitral stenosis, allowing accurate measurements of the orifice area and evaluation of the immediate effects of balloon mitral valvuloplasty; and (3) allowed postoperative evaluation of MV repair and the integrity of the struts of a bioprosthetic leaflet. In protocol II, 70% of patients had adequate RT3DE with complete visualization of the AML noted in 55% versus 51% for PML. The mitral leaflets, commissures, and MV orifice were observed in 69%. Irrespective of acquisition window, the AML was best seen from a ventricular perspective. In contrast, the PML was optimally examined from a parasternal window. Both the medial and lateral commissures were equally assessed from either imaging window. In conclusion, RT3DE of the MV is feasible in a large majority of patients. Using different MV acquisitions RT3DE provides important clinical information such as: (1) identification of a prolapsed/flail scallop; (2) measurement of stenotic valve areas; (3) evaluation of MV leaflet integrity postrepair; and (4) identification of a MV perforation. In general the AML is better visualized than the PML. The parasternal window is the optimal approach to visualize both AML and PMLs.

Computer Systems↗

Quantification of regional left ventricular wall motion from real-time 3-dimensional echocardiography in patients with poor acoustic windows: effects of contrast enhancement tested against cardiac magnetic resonance.

OBJECTIVE: Regional left ventricular function can be assessed by real-time 3-dimensional echocardiography (RT3DE) in patients with good image quality. Our goals were to: (1) test the feasibility of RT3DE quantification of regional wall motion (RWM) in patients with poor acoustic windows who require contrast for endocardial visualization; and (2) validate these measurements against cardiac magnetic resonance (CMR) reference. METHODS: RT3DE datasets and CMR images were obtained in 24 patients. In 16 of 24 patients with suboptimal endocardial definition, RT3DE imaging was repeated with intravenous contrast and triggering at end systole and end diastole. RT3DE datasets were analyzed using custom software designed to semiautomatically detect and segment the endocardial surface and calculate RWM values. CMR images were analyzed using commercial software to obtain reference values for RWM. RESULTS: In 8 of 24 patients with good endocardial definition, RT3DE values of RWM correlated well with CMR (r = 0.73) with a small bias (-1.0 mm). In the remaining 16 patients, analysis of nonenhanced RT3DE datasets yielded lower correlation with CMR (r = 0.61) and a slightly greater bias (-1.5 mm). The agreement with CMR improved significantly (r = 0.76, bias -1.1 mm) with contrast enhancement. CONCLUSIONS: The agreement between RT3DE and CMR values of RWM is directly related to RT3DE image quality. In patients with poor acoustic windows, dual-triggered contrast enhancement improves the accuracy of RWM quantification to a level similar to that noted in patients with good images without contrast.

Computer Systems↗

Computerized evaluation of echocardiographic stress tests in patients with poorly visualized endocardium using analysis of color-encoded contrast-enhanced images.

AIMS: We hypothesized that real-time color encoding of contrast-enhanced images would allow objective detection of stress-induced wall motion abnormalities (WMA). METHODS: We studied 117 patients with poorly visualized endocardium undergoing dobutamine stress tests. Color-encoded images (Philips, color kinesis) were obtained at rest and peak stress in four standard views during i.v. infusion of Definity. Images were reviewed without color overlays by two expert readers, who graded regional wall motion as normal or abnormal. In 101/117 patients (86%), in whom contrast enhancement allowed endocardial tracking, regional fractional area changes were calculated from the color overlays, and thresholds for calling a stress-induced WMA were optimized in a randomly selected subgroup of 34 patients (ROC analysis) to achieve maximum agreement with expert grades. This computerized detection of stress-induced WMA was then tested prospectively in the remaining 67 patients, using the expert grades as a "gold standard". RESULTS: 20/67 patients had resting WMA and 13/67 patients developed WMA at peak stress. The automated technique detected stress-induced WMA in at least one vascular territory with a sensitivity, specificity and accuracy of 0.80, 0.65 and 0.69, while the level of agreement between the two experts was 0.62, 0.91 and 0.85, respectively. CONCLUSION: Analysis of color-encoded, contrast-enhanced images allows objective, accurate, automated detection of stress-induced WMA in patients with poor acoustic windows.

Cardiotonic Agents↗

Imaging and quantification of myocardial perfusion using real-time three-dimensional echocardiography.

OBJECTIVES: We tested the feasibility of real-time three-dimensional echocardiographic (RT3DE) perfusion imaging and developed and validated an algorithm for volumetric analysis of myocardial contrast inflow. The study included three protocols wherein perfusion was measured: 1) in an ex-vivo model of controlled global coronary flow, 2) in an in-vivo model during regional perfusion variations, and 3) in humans during pharmacologically induced hyperemia. BACKGROUND: The RT3DE technology offers an opportunity for myocardial perfusion imaging without multi-slice reconstruction and repeated contrast maneuvers. METHODS: Electrocardiographically triggered harmonic RT3DE datasets were acquired (Philips 7500) while infusion of Definity was initiated and reached a steady state. Protocol 1 was performed in nine isolated rabbit hearts and included three coronary flow levels. In protocol 2, changes in regional perfusion caused by partial left anterior descending artery occlusion were measured in five pigs. In protocol 3, adenosine-induced changes in perfusion were measured in eight normal volunteers. Myocardial video-intensity (MVI) was measured over time in three-dimensional (3D) slices to calculate peak contrast inflow rate (PCIR). In pigs, PCIR was measured on a regional basis and validated against microspheres. RESULTS: The RT3DE imaging allowed selection of slices for perfusion analysis in rabbit hearts, pigs, and humans. Administration of contrast resulted in clearly visible and quantifiable changes in MVI. In rabbits, The PCIR progressively decreased with coronary flow (p < 0.0001). In pigs, coronary occlusion caused a 59 +/- 26% decrease in PCIR exclusively in the left anterior descending artery territory (p < 0.05) in agreement with microspheres. In humans, adenosine increased PCIR to 198 +/- 57% of baseline (p < 0.05). CONCLUSIONS: Contrast-enhanced RT3DE imaging provides the basis for volumetric imaging and quantification of myocardial perfusion.

Adenosine↗

Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data.

AIMS: Determination of left ventricular (LV) volumes and ejection fraction (EF) from two-dimensional echocardiographic (2DE) images is subjective, time-consuming, and relatively inaccurate because of foreshortened views and the use of geometric assumptions. Our aims were (1) to validate a new method for rapid, online measurement of LV volumes from real-time three-dimensional echocardiographic (RT3DE) data using cardiac magnetic resonance (CMR) as the reference and (2) to compare its accuracy and reproducibility with standard 2DE measurements. METHODS AND RESULTS: CMR, 2DE, and RT3DE datasets were obtained in 50 patients. End-systolic and end-diastolic volumes (ESV and EDV) were calculated from the 2DE images using biplane method of disks. ES and ED RT3DE datasets were analysed using prototype software designed to automatically detect the endocardial surface using a deformable shell model and calculate ESV and EDV from voxel counts. 2DE and RT3DE-derived volumes were compared with CMR (linear regression, Bland-Altman analysis). In most patients, analysis of RT3DE data required <2 min per patient. RT3DE measurements correlated highly with CMR (r: 0.96, 0.97, and 0.93 for EDV, ESV, and EF, respectively) with small biases (-14 mL, -6.5 mL, -1%) and narrow limits of agreement (SD: 17 mL, 16 mL, 6.4%). 2DE measurements correlated less well with CMR (r: 0.89, 0.92, 0.86) with greater biases (-23 mL, -15 mL, 1%) and wider limits of agreement (SD: 29 mL, 24 mL, 9.5%). RT3DE resulted in lower intra-observer (EDV: 7.9 vs. 23%; ESV: 7.6 vs. 26%) and inter-observer variability (EDV: 11 vs. 26%; ESV: 13 vs. 31%). CONCLUSION: Semi-automated detection of the LV endocardial surface from RT3DE data is suitable for clinical use because it allows rapid, accurate, and reproducible measurements of LV volumes, superior to conventional 2DE methods.

Echocardiography, Three-Dimensional↗

Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images.

BACKGROUND: Real-time 3D echocardiographic (RT3DE) data sets contain dynamic volumetric information on cardiac function. However, quantification of left ventricular (LV) function from 3D echocardiographic data is performed on cut-planes extracted from the 3D data sets and thus does not fully exploit the volumetric information. Accordingly, we developed a volumetric analysis technique aimed at quantification of global and regional LV function. METHODS AND RESULTS: RT3DE images obtained in 30 patients (Philips 7500) were analyzed by use of custom software based on the level-set approach for semiautomated detection of LV endocardial surface throughout the cardiac cycle, from which global and regional LV volume (LVV)-time and wall motion (WM)-time curves were obtained. The study design included 3 protocols. In protocol 1, time curves obtained in 16 patients were compared point-by-point with MRI data (linear regression and Bland-Altman analyses). Global LVV correlated highly with MRI (r=0.98; y=0.99x+2.3) with minimal bias (1.4 mL) and narrow limits of agreement (+/-20 mL). WM correlated highly only in basal and midventricular segments (r=0.88; y=0.85x+0.7). In protocol 2, we tested the ability of this technique to differentiate populations with known differences in LV function by studying 9 patients with dilated cardiomyopathy and 9 normal subjects. All calculated indices of global and regional systolic and diastolic LV function were significantly different between the groups. In protocol 3, we tested the feasibility of automated detection of regional WM abnormalities in 11 patients. In each segment, abnormality was detected when regional shortening fraction was below a threshold obtained in normal subjects. The automated detection agreed with expert interpretation of 2D WM in 86% of segments. CONCLUSIONS: Volumetric analysis of RT3DE data is clinically feasible and allows fast, semiautomated, dynamic measurement of LVV and automated detection of regional WM abnormalities.

Adult↗

Improved semiautomated quantification of left ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: comparison with magnetic resonance imaging.

Our goals were to: (1) develop a technique for 3-dimensional (3D) direct, model-independent quantitative assessment of left ventricular (LV) volume and ejection fraction based on semiautomated detection of LV endocardial surface from transthoracic near real-time full matrix-array 3D echocardiographic (FM3DE) imaging; (2) evaluate the accuracy of LV volumes obtained with this technique, using cardiac magnetic resonance imaging (MRI) measurements as the reference for comparison; and (3) determine the effects of contrast enhancement on the accuracy of FM3DE measurements. A total of 46 patients underwent 2-dimensional echocardiography, FM3DE, and cardiac MRI. End-diastolic volume, end-systolic volume, and ejection fraction were derived from endocardial borders manually traced from 2-dimensional echocardiographic images and from semiautomatically detected LV cavity from FM3DE data. In 14 patients, FM3DE was also acquired with contrast. All measurements were compared with MRI values using linear regression and Bland-Altman analyses. FM3DE was feasible in 44 of 46 patients with LV volumes < 345 mL. LV volumes and ejection fraction computed from FM3DE resulted in higher levels of agreement with MRI than conventional 2-dimensional echocardiography, with lower interobserver variability. With contrast enhancement, FM3DE significantly underestimated LV volumes and showed increased interobserver variability. Semiautomated LV endocardial surface detection from FM3DE images is feasible and results in fast and accurate assessment of LV function.

Adult↗

Quantitative echocardiographic evaluation of myocardial perfusion using interrupted contrast infusion technique: in vivo validation studies and feasibility in human beings.

BACKGROUND: We recently developed a new approach for contrast echocardiographic quantification of myocardial perfusion, based on brief interruptions of contrast infusion, which was designed to overcome the limitations of existing techniques. In this study, our technique was initially validated in a series of animal experiments designed to detect regional perfusion variations in vivo. Subsequently, clinical feasibility of perfusion measurements was tested. METHODS: Regional perfusion was measured transthoracically in 6 anesthetized pigs during baseline, partial left anterior descending coronary artery occlusion, and reperfusion, and validated with fluorescent microspheres. Adenosine-induced changes in perfusion were measured in 8 healthy volunteers. In both protocols, imaging was optimized during contrast infusion (Definity). Infusion was interrupted to allow contrast clearance and images were acquired during subsequent contrast inflow. Myocardial videointensity was measured over time and peak contrast inflow rate was calculated. RESULTS: In pigs, partial coronary occlusion resulted in a 47 +/- 23% decrease in peak contrast inflow rate in the left anterior descending coronary artery perfusion territory (P < .05), which was reversed during reperfusion, without concomitant decrease in other perfusion territories. These changes were in agreement with microspheres. In human beings, adenosine increased peak contrast inflow rate to 278 +/- 123% of baseline (P < .05). CONCLUSION: The interruption of contrast infusion technique is a sensitive tool for accurate quantification of myocardial perfusion, which may constitute an alternative to currently used techniques.

Animals↗

Evaluation of left ventricular systolic function using automated angle-independent motion tracking of mitral annular displacement.

Determination of ejection fraction (EF) in clinical practice typically involves manual tracing of endocardial borders. This method is time-intensive and highly dependent on image quality. Mitral annular displacement (MAD) has been shown to correlate well with EF. Previously, this method involved tedious analysis of M-mode tracings. We developed and studied a new technique that is ultrasound beam angle-independent for automated detection of MAD, based on a tissue tracking algorithm. A regression formula was derived in a study group to predict EF from MAD measurements and tested prospectively in a separate group of patients. We found that our technique provides accurate, ultra-fast estimation of EF with lower inter- and intraobserver variability when compared with manually traced biplane EF.

Adult↗

Prognostic value of echocardiography in peripartum cardiomyopathy.

OBJECTIVE: To estimate whether echocardiography findings at the time of diagnosis of peripartum cardiomyopathy are predictive of persistent cardiac dysfunction. METHODS: Chart review of patients with peripartum cardiomyopathy between 1988 and 2001 was performed. Data from echocardiography, including fractional shortening and left ventricular end diastolic dimension, were recorded both at the time of diagnosis and at follow-up. Left ventricular dysfunction was defined by echocardiography as fractional shortening less than 30% and left ventricular end diastolic dimension of 4.8 cm or more. RESULTS: Of 32 patients meeting our definition for peripartum cardiomyopathy and for whom follow-up data were available, 13 (41%) had recovery of ventricular function, while 19 (59%) continued to have persistent left ventricular dysfunction. Those who did not recover cardiac function had a higher left ventricular end diastolic dimension and a lower fractional shortening at diagnosis than those who recovered. A fractional shortening value less than 20% and a left ventricular end diastolic dimension 6 cm or greater at the time of diagnosis was associated with a more than 3-fold higher risk for persistent left ventricular dysfunction. CONCLUSION: Along with being an important diagnostic tool in peripartum cardiomyopathy, echocardiography may provide significant prognostic information with regards to recovery of cardiac function.

Adolescent↗

Fast measurement of left ventricular mass with real-time three-dimensional echocardiography: comparison with magnetic resonance imaging.

BACKGROUND: Left ventricular (LV) mass is an important predictor of morbidity and mortality, especially in patients with systemic hypertension. However, the accuracy of 2D echocardiographic LV mass measurements is limited because acquiring anatomically correct apical views is often difficult. We tested the hypothesis that LV mass could be measured more accurately from real-time 3D (RT3D) data sets, which allow offline selection of nonforeshortened apical views, by comparing 2D and RT3D measurements against cardiac MR (CMR) measurements. METHODS AND RESULTS: Echocardiographic imaging was performed (Philips 7500) in 21 patients referred for CMR imaging (1.5 T, GE). Apical 2- and 4-chamber views and RT3D data sets were acquired and analyzed by 2 independent observers. The RT3D data sets were used to select nonforeshortened apical 2- and 4-chamber views (3DQ-QLAB, Philips). In both 2D and RT3D images, LV long axis was measured; endocardial and epicardial boundaries were traced, and mass was calculated by use of the biplane method of disks. CMR LV mass values were obtained through standard techniques (MASS Analysis, GE). The RT3D data resulted in significantly larger LV long-axis dimensions and measurements of LV mass that correlated with CMR better (r=0.90) than 2D (r=0.79). The 2D technique underestimated LV mass (bias, 39%), whereas RT3D measurements showed only minimal bias (3%). The 95% limits of agreement were significantly wider for 2D (52%) than RT3D (28%). Additionally, the RT3D technique reduced the interobserver variability (37% to 7%) and intraobserver variability (19% to 8%). CONCLUSIONS: RT3D imaging provides the basis for accurate and reliable measurement of LV mass.

Adult↗

Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation: an accurate and novel approach.

OBJECTIVES: Our aim was to assess which echo-Doppler method has the best agreement with the mitral valve area (MVA) invasively evaluated by the Gorlin's formula. We also evaluated the feasibility and reproducibility of real-time three-dimensional echocardiography (RT3D) for the estimation of MVA and the Wilkins score in patients with rheumatic mitral stenosis (RMVS). BACKGROUND: Real-time three-dimensional echocardiography is a novel technique that allows us to visualize the mitral valvular anatomy in any desired plane orientation. The usefulness and accuracy of this technique for evaluating RMVS has not been established. METHODS: We studied a series of consecutive patients with RMVS from two tertiary care hospitals. Mitral valvular area was determined by conventional echo-Doppler methods and by RT3D, and their results were compared with those obtained invasively. Real-time three-dimensional echocardiography planimetry and mitral score were measured by two independent observers and then repeated by one of them. RESULTS: Eighty patients with RMVS comprised our study group (76 women; 50.6 +/- 13.9 years). Compared with all other echo-Doppler methods, RT3D had the best agreement with the invasively determined MVA (average difference between both methods and limits of agreement: 0.08 cm(2) [-0.48 to 0.6]). Interobserver variability was as good for RT3D (intraclass correlation coefficient [ICC] = 0.90) as for pressure half-time (PHT) (ICC = 0.95). For PHT and RT3D, the intraobserver variability was similar (ICC 0.92 and 0.96, respectively). Real-time three-dimensional echocardiography valvular score evaluation showed a better interobserver agreement with RT3D than with 2D echocardiography. CONCLUSIONS: Real-time three-dimensional echocardiography is a feasible, accurate, and highly reproducible technique for assessing MVA in patients with RMVS. Real-time three-dimensional echocardiography has the best agreement with invasive methods.

Echocardiography, Three-Dimensional↗

Differential diagnosis of cardiac masses using contrast echocardiographic perfusion imaging.

OBJECTIVES: We investigated the usefulness of echocardiographic contrast perfusion imaging in differentiating cardiac masses. BACKGROUND: Two-dimensional echocardiography is the primary diagnostic modality for cardiac masses. However, differentiation between the different types of cardiac masses may be difficult at times. We hypothesized that echocardiographic contrast perfusion imaging would differentiate the neo-vascularization of malignancies from the avascularity of thrombi and the sparse vascularity of stromal tumors. METHODS: Sixteen patients with cardiac masses underwent power-modulation imaging after echocardiographic intravenous contrast administration. Pixel intensities in the mass and an adjacent section of myocardium were analyzed visually and by dedicated software. All masses had a pathologic diagnosis or resolved after anticoagulation. In a subset of patients, video-intensity curves of contrast replenishment in the mass and myocardium over time were generated. The post-impulse steady-state pixel intensity (A) and initial rate of contrast replenishment after impulse (beta) were compared with an index of blood vessel area on pathology. RESULTS: In seven of 16 patients, contrast enhancement resulted in greater pixel intensity in the mass than in the adjacent myocardium. All of these masses were classified pathologically as malignant (n = 6) or benign and vascular (n = 1). Nine masses demonstrated decreased pixel intensity, compared with the myocardium, and were diagnosed pathologically as myxomas (n = 2) or thrombi (n = 5), or they resolved with anticoagulation (n = 2). For the subset of patients, beta correlated with the vessel area index (r = 0.60). CONCLUSIONS: Echocardiographic contrast perfusion imaging aids in the differentiation of cardiac masses. Compared with the adjacent myocardium, malignant and vascular tumors hyper-enhanced, whereas stromal tumors and thrombi hypo-enhanced.

Adult↗