PubMed Health⌕ Search

Biomedical subjects

Lynne Richter

Publications and source records attributed to Lynne Richter.

2 recordsLinked to original sources

Eye-movement study and human performance using telepathology virtual slides: implications for medical education and differences with experience.

A core skill in diagnostic pathology is light microscopy. Remarkably little is known about human factors that affect the proficiency of pathologists as light microscopists. The cognitive skills of pathologists have received relatively little attention in comparison with the large literature on human performance studies in radiology. One reason for this lack of formal visual search studies in pathology has been the physical restrictions imposed by the close positioning of a microscope operator's head to the microscope's eyepieces. This blocks access to the operator's eyes and precludes assessment of the microscopist's eye movements. Virtual slide microscopy now removes this barrier and opens the door for studies on human factors and visual search strategies in light microscopy. The aim of this study was to assess eye movements of medical students, pathology residents, and practicing pathologists examining virtual slides on a digital display monitor. Whole histopathology glass slide digital images, so-called virtual slides, of 20 consecutive breast core biopsy cases were used in a retrospective study. These high-quality virtual slides were produced with an array-microscope equipped DMetrix DX-40 ultrarapid virtual slide processor (DMetrix, Tucson, Ariz). Using an eye-tracking device, we demonstrated for the first time that when a virtual slide reader initially looks at a virtual slide his or her eyes are very quickly attracted to regions of interest (ROIs) within the slide and that these ROIs are likely to contain diagnostic information. In a matter of seconds, critical decisions are made on the selection of ROIs for further examination at higher magnification. We recorded: (1) the time virtual slide readers spent fixating on self-selected locations on the video monitor; (2) the characteristics of the ways the eyes jumped between fixation locations; and (3) x and y coordinates for each virtual slide marking the sites the virtual slide readers manually selected for zooming to higher ROI magnifications. We correlated the locations of the visually selected fixation locations and the manually selected ROIs. Viewing profiles were identified for each group. Fully trained pathologists spent significantly less time (mean, 4.471 seconds) scanning virtual slides when compared to pathology residents (mean, 7.148 seconds) or medical students (mean, 11.861 seconds), but had relatively prolonged saccadic eye movements (P < .0001). Saccadic eye movements are defined as eye movements between fixation locations. On the other hand, the pathologists spent significantly more time than trainees dwelling on the 3 locations they subsequently chose for zooming. Unlike either the medical students or the residents, the pathologists frequently choose areas for viewing at higher magnification outside of areas of foveal (central) vision. Eye movement studies of scanning pathways (scan paths) may be useful for developing eye movement profiles for individuals and for understanding the difference in performances between novices and experts. They may also be useful for developing new visual search strategies for rendering diagnoses on telepathology virtual slides.

Biopsy↗

An array microscope for ultrarapid virtual slide processing and telepathology. Design, fabrication, and validation study.

This paper describes the design and fabrication of a novel array microscope for the first ultrarapid virtual slide processor (DMetrix DX-40 digital slide scanner). The array microscope optics consists of a stack of three 80-element 10 x 8-lenslet arrays, constituting a "lenslet array ensemble." The lenslet array ensemble is positioned over a glass slide. Uniquely shaped lenses in each of the lenslet arrays, arranged perpendicular to the glass slide constitute a single "miniaturized microscope." A high-pixel-density image sensor is attached to the top of the lenslet array ensemble. In operation, the lenslet array ensemble is transported by a motorized mechanism relative to the long axis of a glass slide. Each of the 80 miniaturized microscopes has a lateral field of view of 250 microns. The microscopes of each row of the array are offset from the microscopes in other rows. Scanning a glass slide with the array microscope produces seamless two-dimensional image data of the entire slide, that is, a virtual slide. The optical system has a numerical aperture of N.A.= 0.65, scans slides at a rate of 3 mm per second, and accrues up to 3,000 images per second from each of the 80 miniaturized microscopes. In the ultrarapid virtual slide processing cycle, the time for image acquisition takes 58 seconds for a 2.25 cm2 tissue section. An automatic slide loader enables the scanner to process up to 40 slides per hour without operator intervention. Slide scanning and image processing are done concurrently so that post-scan processing is eliminated. A virtual slide can be viewed over the Internet immediately after the scanning is complete. A validation study compared the diagnostic accuracy of pathologist case readers using array microscopy (with images viewed as virtual slides) and conventional light microscopy. Four senior pathologists diagnosed 30 breast surgical pathology cases each using both imaging modes, but on separate occasions. Of 120 case reads by array microscopy, there were 3 incorrect diagnoses, all of which were made on difficult cases with equivocal diagnoses by light microscopy. There was a strong correlation between array microscopy vs. "truth" diagnoses based on surgical pathology reports. The kappa statistic for the array microscopy vs. truth was 0.96, which is highly significant (z=10.33, p <0.001). There was no statistically significant difference between rates of agreement with truth between array microscopy and light microscopy (z=0.134, p >0.05). Array microscopy and light microscopy did not differ significantly with respect to the number/percent of correct decisions rendered (t=0.552, p=0.6376) or equivocal decisions rendered (t=2.449, p=0.0917). Pathologists rated 95.8% of array microscopy virtual slide images as good or excellent. None were rated as poor. The mean viewing time for a DMetrix virtual slide was 1.16 minutes. The DMetrix virtual slide processor has been found to reduce the virtual slide processing cycle more than 10 fold, as compared with other virtual slide systems reported to date. The virtual slide images are of high quality and suitable for diagnostic pathology, second opinions, expert opinions, clinical trials, education, and research.

Equipment Design↗