PubMed HealthSearch

Biomedical subjects

M A Anastasio

Publications and source records attributed to M A Anastasio.

2 recordsLinked to original sources

Optimization and FROC analysis of rule-based detection schemes using a multiobjective approach.

Computerized detection schemes have the potential of increasing diagnostic accuracy in medical imaging by alerting radiologists to lesions that they initially overlooked. These schemes typically employ multiple parameters such as threshold values or filter weights to arrive at a detection decision. In order for the system to have high performance, the values of these parameters need to be set optimally. Conventional optimization techniques are designed to optimize a scalar objective function. The task of optimizing the performance of a computerized detection scheme, however, is clearly a multiobjective problem: we wish to simultaneously improve the sensitivity and false-positive rate of the system. In this work we investigate a multiobjective approach to optimizing computerized rule-based detection schemes. In a multiobjective optimization, multiple objectives are simultaneously optimized, with the objective now being a vector-valued function. The multiobjective optimization problem admits a set of solutions, known as the Pareto-optimal set, which are equivalent in the absence of any information regarding the preferences of the objectives. The performances of the Pareto-optimal solutions can be interpreted as operating points on an optimal free-response receiver operating characteristic (FROC) curve, greater than or equal to the points on any possible FROC curve for a given dataset and detection scheme. It is demonstrated that generating FROC curves in this manner eliminates several known problems with conventional FROC curve generation techniques for rule-based detection schemes. We employ the multiobjective approach to optimize a rule-based scheme for clustered microcalcification detection that has been developed in our laboratory.

Algorithms

A genetic algorithm-based method for optimizing the performance of a computer-aided diagnosis scheme for detection of clustered microcalcifications in mammograms.

Computer-aided diagnosis (CAD) schemes have the potential of substantially increasing diagnostic accuracy in mammography by providing the advantages of having a second reader. Our laboratory has developed a CAD scheme for detecting clustered microcalcifications in digital mammograms that is being tested clinically at the University of Chicago Hospitals. Our CAD scheme contains a large number of parameters such as filter weights, threshold levels, and region of interest (ROI) sizes. The choice of these parameter values determines the overall performance of the system and thus must be carefully set. Unfortunately, when the number of parameters becomes large, it is very difficult to obtain the optimal performance, especially when the values of the parameters are correlated with each other. In this study, we address the problem of identifying the optimal overall performance by developing an automated method for the determination of the parameter values that maximize the performance of a mammographic CAD scheme. Our method utilizes a genetic algorithm to search through the possible parameter values, and provides the set of parameters that minimize a cost function which measures the performance of the scheme. Using a database of 89 digitized mammograms, our method demonstrated that the sensitivity of our CAD scheme can be increased from 80% to 87% at a false positive rate of 1.0 per image. We estimate the average performance of our CAD scheme on unknown cases by performing jackknife tests; this was previously not feasible when the parameters of the CAD scheme were determined in a nonautomated manner.

Algorithms