PubMed Health⌕ Search

Biomedical subjects

M A Boucher

Publications and source records attributed to M A Boucher.

6 recordsLinked to original sources

Arteriovenous malformation mimicking femoral osteolysis after total hip arthroplasty.

We encountered a case of apparent progressive femoral osteolysis around a well-fixed cementless implant in a young patient. At the time of revision arthroplasty, massive hemorrhaging occurred during exposure and attempted femoral component extraction. Urgent packing of the exposed endosteum with polymethyl methacrylate controlled the bone bleeding. Emergent angiography confirmed an arteriovenous malformation with extensive proximal diaphyseal involvement directly at the site of osteolysis. This arteriovenous malformation was treated successfully with selective arterial embolization and second-stage resection. In retrospect, the index arthroplasty operative note indicated an excessive amount of blood loss, and prerevision radiographs showed osteolysis with uncharacteristic vascular markings. The presence of an osteolytic lesion in total hip arthroplasty should not be assumed to be attributed to polyethylene granuloma, and any atypical radiographic features should prompt further preoperative investigations.

Adult↗

Restless legs syndrome in home healthcare.

Restless legs syndrome affects millions, but most healthcare providers don't know it exists. Its sleep-deprived victims are plagued by indescribable crawling sensations in their legs that occur at night and that are only relieved by moving the legs. Many home healthcare clients, already challenged by their primary illness, are also affected by the persistent symptoms of Restless Legs Syndrome. It is important that home care nurses learn about Restless Legs Syndrome-what it is, how to assess it, and what can be done about it.

Community Health Nursing↗

Measurement of sleep-related breathing disturbances in epidemiologic studies. Assessment of the validity and reproducibility of a portable monitoring device.

The feasibility and reliability of measuring sleep-related breathing disorders with a portable monitor (PM) were assessed in a heterogeneous population, consisting of 31 patients recruited from a sleep laboratory and pulmonary disease clinic, 16 participants in a genetic-epidemiologic study of sleep apnea, and four volunteers with no specific sleep complaints. The validity of measurements made by the PM was assessed with comparisons of respiratory parameters made with the PM to those determined with in-hospital polysomnography (PSG) (25 studies). Reproducibility was assessed in 29 subjects who underwent in-home monitoring on two occasions. There was a high level of agreement between the number of respiratory events (apneas or hypopneas) per hour of estimated sleep (respiratory disturbance index, RDI) recorded with the PM and PSG and log-transformed (r = 0.96). Using a RDI of greater than or equal to 10 to define "abnormality," 20 of the 21 subjects who would have been classified as abnormal with PSG were classified similarly with use of the PM. A similar high level of agreement was demonstrated for the log-transformed RDI determined with replicate in-home studies (r = 0.94). No evidence of a "first-night effect" for the RDI was suggested in studies performed with the PM; ie, RDI was 18.4 +/- 27.7 and 17.4 +/- 25.7 (mean +/- SD) for first and second night studies, respectively (p = 0.21). A second compared with an initial study with the PM would have resulted in reclassification of abnormality based on an RDI of greater than or equal to 10 in one subject. These findings suggest that measurement of the RDI with in-home monitoring provides a valid and highly reproducible index for assessment of sleep-related respiratory disturbances for use in epidemiologic studies of general populations.

Adult↗

A family study of sleep apnea. Anatomic and physiologic interactions.

The distribution of symptoms, physiologic responses, and upper airway structure in members of one family with three generations of subjects with sleep apnea (SA) is reported. Questionnaire data were obtained from ten family members (ages 7 to 66 years), overnight sleep studies were performed in nine subjects, and ventilatory responses to hyperoxic hypercapnia and to eucapnic hypoxia and cephalometry were obtained in five subjects. All ten family members reported habitual snoring or nighttime snorting/gasping; five of ten family members also reported excessive daytime sleepiness. All studied subjects except for a pregnant woman had greater than ten apneas/hypopneas per hour. Ventilatory responses to hypoxia were markedly reduced in all five subjects studied (less than or equal to 0.51 L/min/SaO2); hypercapnic responses were reduced in three of five subjects (less than or equal to 0.61 L/min/mm Hg CO2). No subject was morbidly obese (body mass index less than 29 kg/m2) or demonstrated retrognathia. The posterior airway space was reduced in three subjects, and the mandibular to hyoid distance was increased in four subjects. The two subjects with the longest soft palates and the most inferiorly displaced hyoids had the most severe sleep disorder. Sleep apnea was present, albeit less profound, in the one subject with normal anatomy who had an abnormal hypoxic ventilatory response. The distribution of these physiologic and anatomic measurements in this family provides further support for a genetic basis for SA, and suggests that the disorder may occur as a result of interactions between ventilatory control abnormalities and anatomic risk factors.

Adult↗