PubMed Health⌕ Search

Biomedical subjects

M A Costa

Publications and source records attributed to M A Costa.

At least 19 recordsLinked to original sources

Use of rapamycin-impregnated stents in coronary arteries.

FIM STUDY: We investigated the 2-year safety and efficacy of sirolimus-eluting stents. Thirty patients had a single 18-mm sirolimus-eluting coronary stent implanted. Twenty-eight patients underwent angiographic and intravascular ultrasound follow-up at 2 years. No death occurred during the study period. No patient developed in-stent restenosis. One patient had a 52% in-lesion stenosis that required repeated revascularization and another patient underwent target vessel revascularization. Neointimal hyperplasia volume was minimal at 2 years in both groups. This study demonstrates the 2-year safety and efficacy of sirolimus-eluting stenting. The slow release formulation showed slight superiority over the fast-release formulation in preventing late lumen loss, which was minimal in both groups. RAVEL TRIAL: This-study was a randomized, double-blind study that included 238 patients at 19 medical centers (15 in Europe, 3 in Brazil, and 1 in Mexico). Patients were eligible for the study if they were between 18 and 85 years of age, and had been given a diagnosis of stable or unstable angina or silent ischemia. Additional eligibility criteria were presence of a single primary target lesion in a native coronary artery that was 2.5 to 3.5 mm in diameter and that could be covered by an 18-mm stent stenosis of 51% to 99% of the luminal diameter and a flow rate of grade 1 or higher according to the Thrombolysis in Myocardial Infarction. RESULTS: One hundred twenty patients were randomly assigned to receive the sirolimus-eluting stent, and 118 were assigned to receive the standard stent. At 6 months, the degree of neointimal proliferation, manifested as the mean (+/-SD) late luminal loss, was significantly lower in the sirolimus-stent group (-0.01 +/- 0.33 mm) than in the standard-stent group (0.80 +/- 0.53 mm, P <.001). None of the patients in the sirolimus-stent group, as compared with 26.6% of those in the standard-stent group, had restenosis of >/=50% of the luminal diameter (P <.001). There were no episodes of stent thrombosis. During a follow-up period of up to 1 year, the overall rate of major cardiac events was 5.8% in the sirolimus-stent group and 28.8% in the standard-stent group (P <.001). The difference was due entirely to the higher rate of revascularization of the target vessel in the standard-stent group. CONCLUSION: Patients with angina who received sirolimus-eluting stents for the treatment of single, primary lesions in native coronary arteries had no angiographic evidence of late luminal loss or in-stent restenosis at 6 months, no episodes of thrombosis, and a very low rate of cardiac events at 1 year.

Adolescent↗

Coronary flow velocity reserve after percutaneous interventions is predictive of periprocedural outcome.

BACKGROUND: Because heterogeneous results have been reported, we assessed coronary flow velocity changes in individuals who underwent percutaneous transluminal coronary angioplasty (PTCA) and examined their impact on clinical outcome. METHODS AND RESULTS: As part of the Doppler Endpoints Balloon Angioplasty Trial Europe (DEBATE) II study, 379 patients underwent Doppler flow-guided angioplasty. All patients were evaluated according to their coronary flow velocity reserve (CFVR) results (> or =2.5 or < 2.5) at the end of the procedure. A CFVR < 2.5 after angioplasty was associated with an elevated baseline blood flow velocity in both the target artery and reference artery. CFVR before PTCA and CFVR in the reference artery were independent predictors of an optimal CFVR after balloon angioplasty (CFVR before PTCA: odds ratio [OR], 2.26; 95% confidence interval [CI], 1.57 to 3.24; CFVR in reference artery: OR, 1.90; 95% CI, 1.21 to 2.98; both P<0.001) and stent implantation (before PTCA: OR, 2.54; 95% CI, 1.47 to 4.36; reference artery: OR, 1.97; 95% CI, 1.07 to 3.87; both P<0.05). A low CFVR at the end of the procedure was an independent predictor of major adverse cardiac events (MACE) at 30 days (OR, 4.71; 95% CI, 1.14 to 25.92; P=0.034) and at 1 year (OR, 2.06; 95% CI, 1.16 to 3.66; P=0.014). After excluding MACE at 30 days, no difference in MACE at 1 year was observed between the patients with and without a CFVR < 2.5 at the end of the procedure. CONCLUSIONS: A low postprocedural CFVR was associated with a worse periprocedural outcome (which was related to microcirculatory disturbances), but there was no significant difference at late follow-up.

Angioplasty, Balloon, Coronary↗

Si(3)N(4)-bioglass composites stimulate the proliferation of MG63 osteoblast-like cells and support the osteogenic differentiation of human bone marrow cells.

The in vitro osteocompatibility of a novel Si(3)N(4)-bioglass composite (70-30% weight proportion) with improved mechanical properties (fracture toughness = 4.4 M Pa m(1/2); bending strength = 383 +/- 47 MPa) is reported. Immersion of the composite samples in culture medium (30 min to 7 days) resulted in rapid protein adsorption to the surface and, also, dissolution of the intergranular phase of bioglass (time-dependent process) with the formation of different size cavities. "As-received" and pre-treated material samples presented a similar behaviour concerning the proliferation of MG63 osteoblast-like cells, evaluated during a 5-day culture period. Seeded materials showed a higher cell growth rate as compared to cultures performed on the standard plastic culture plates. To assess the osteogenic potential of the composite, "as-received" material samples were seeded with human bone marrow cells and cultured for 35 days in experimental conditions that favour the development of the osteoblastic phenotype. The cell adhesion process was similar to that observed in control cultures. Cells successfully adapted to the irregularities of the surface and were able to grow towards inside the cavities; in addition, osteogenic differentiation occurred with the formation of abundant cell-mediated mineralised deposits. Results suggest that this Si(3)N(4)-bioglass composite seems to be a promising candidate for high-stress medical applications.

Adsorption↗

[False hyperchloremia in a bromide intoxication].

A false hyperchloremia in a patient with a history of depression suspected bromide intoxication. The diagnosis was confirmed by an increased bromide concentration > 20 mmoL.L-1. Rehydration was effective and allowed to decrease bromide concentration. In conclusion, hyperchloremia associated with a negative anion gap is a clue to the diagnosis.

Bromides↗

Initial observation regarding changes in vessel dimensions after balloon angioplasty and stenting followed by catheter-based beta-radiation. Is stenting necessary in the setting of catheter-based radiotherapy?

AIMS: We sought to compare the effect of intracoronary beta-radiation on the vessel dimensions in de novo lesions using three-dimensional intravascular ultrasound quantification after balloon angioplasty and stenting. METHODS AND RESULTS: Forty patients (44 vessels; 28 balloon angioplasty and 16 stenting) treated with catheter-based beta-radiation and 18 non-irradiated control patients (18 vessels; 10 balloon angioplasty and 8 stenting) were investigated by means of three-dimensional volumetric intravascular ultrasound analysis post-procedure and at 6-8 months follow-up. Total vessel (EEM) volume enlarged after both balloon angioplasty and stenting (+37 mm(3) vs +42 mm(3), P=ns), but vessel wall volume (plaque plus media) also increased similarly (+33 mm(3) vs +49 mm(3), P=ns) in the irradiated patients. Lumen volume remained unchanged in both groups (+3 mm(3) vs -7 mm(3), P=ns). In the stent-covered segments, neointima at follow-up was significantly smaller in the irradiated group than the control group (8 mm(3) vs 27 mm(3), P=0.001, respectively), but the total amount of tissue growth was similar in both groups (33 mm(3) vs 29 mm(3), P=ns). CONCLUSIONS: Intracoronary beta-radiation induces vessel enlargement after balloon angioplasty and/or stenting, accommodating tissue growth. Additional stenting may not play an important role in the prevention of constrictive remodelling in the setting of catheter-based intracoronary beta-radiotherapy.

Aged↗

Value of coronary stenotic flow velocity acceleration in prediction of angiographic restenosis following balloon angioplasty.

INTRODUCTION: Quantitative angiographic assessment after balloon angioplasty is a poor predictor of immediate and long-term outcome. However, the measurement of blood flow velocity during angioplasty has been proved clinically useful. AIMS: To analyse the value of the maximal stenotic flow velocity and the presence of stenotic flow velocity acceleration (aSV) for the long-term outcome after balloon angioplasty. METHODS AND RESULTS: Patients undergoing single lesion angioplasty within the DEBATE trial were included. aSV was defined as acceleration in the stenotic coronary flow velocity >50% baseline velocity assessed at a reference site of the target vessel. After balloon angioplasty diameter stenosis, minimal lumen diameter (MLD) and coronary flow velocity reserve were similar between the aSV (n=54) and non-aSV group (n=125). At follow-up, the aSV group had a higher restenosis rate (52% vs 30%, P=0.006) The presence of aSV was the strongest independent predictor of restenosis (OR 3.08, 95% CI 1.35 to 7.05, P=0.008). The best predictive cut-off value of SV was 101cm.s(-1) (sensitivity of 46%, specificity of 81%, positive predictive value of 85% and a negative predictive value of 58%). CONCLUSION: Following angioplasty, SV appears to be exquisitely sensitive to the changes experienced at the treated area without depending on the status of the microcirculation.

Angioplasty, Balloon↗

Paradoxical responses in a cohort of HIV-1-infected patients with mycobacterial disease.

SETTING: Paradoxical worsening or relapse of opportunistic infections has been described after initiation of highly active anti-retroviral therapy (HAART) in human immunodeficiency virus (HIV) infected patients. DESIGN: Retrospective study of a group of 33 HIV-infected patients with mycobacterial disease analysing the incidence and characteristics of patients with and without paradoxical response after starting HAART and/or mycobacterial treatment. RESULTS: Nine patients in the group had paradoxical response. No significant difference of baseline characteristics was observed in these patients. The decrease in viral load was significantly greater among patients with paradoxical response than in patients without. CONCLUSION: No clinical difference was found in the evolution of HIV-infected patients with mycobacterial disease after the resolution of the episode of paradoxical response.

AIDS-Related Opportunistic Infections↗

Incidence, predictors, and significance of abnormal cardiac enzyme rise in patients treated with bypass surgery in the arterial revascularization therapies study (ARTS).

BACKGROUND: Although it has been suggested that elevation of CK-MB after percutaneous coronary intervention is associated with adverse clinical outcomes, limited data are available in the setting of coronary bypass grafting. The aim of the present study was to determine the incidence, predictors, and prognostic significance of CK-MB elevation following multivessel coronary bypass grafting (CABG). METHODS AND RESULTS: The population comprises 496 patients with multivessel coronary disease assigned to CABG in the Arterial Revascularization Therapies Study (ARTS). CK-MB was prospectively measured at 6, 12, and 18 hours after the procedure. Thirty-day and 1-year clinical follow-up were performed. Abnormal CK-MB elevation occurred in 61.9% of the patients. Patients with increased cardiac-enzyme levels after CABG were at increased risk of both death and repeat myocardial infarction within the first 30 days (P=0.001). CK-MB elevation was also independently related to late adverse outcome (P=0.009, OR=0.64). CONCLUSIONS: Increased concentrations of CK-MB, which are often dismissed as inconsequential in the setting of multivessel CABG, appear to occur very frequently and are associated with a significant increase in both repeat myocardial infarction and death beyond the immediate perioperative period.

Biomarkers↗

Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up.

BACKGROUND: We have previously reported a virtual absence of neointimal hyperplasia 4 months after implantation of sirolimus-eluting stents. The aim of the present investigation was to determine whether these results are sustained over a period of 1 year. METHODS AND RESULTS: Forty-five patients with de novo coronary disease were successfully treated with the implantation of a single sirolimus-eluting Bx VELOCITY stent in São Paulo, Brazil (n=30, 15 fast release [group I, GI] and 15 slow release [GII]) and Rotterdam, The Netherlands (15 slow release, GIII). Angiographic and volumetric intravascular ultrasound (IVUS) follow-up was obtained at 4 and 12 months (GI and GII) and 6 months (GIII). In-stent minimal lumen diameter and percent diameter stenosis remained essentially unchanged in all groups (at 12 months, GI and GII; at 6 months, GIII). Follow-up in-lesion minimal lumen diameter was 2.28 mm (GIII), 2.32 mm (GI), and 2.48 mm (GII). No patient approached the >/=50% diameter stenosis at 1 year by angiography or IVUS assessment, and no edge restenosis was observed. Neointimal hyperplasia, as detected by IVUS, was virtually absent at 6 months (2+/-5% obstruction volume, GIII) and at 12 months (GI=2+/-5% and GII=2+/-3%). CONCLUSIONS: This study demonstrates a sustained suppression of neointimal proliferation by sirolimus-eluting Bx VELOCITY stents 1 year after implantation.

Blood Vessel Prosthesis Implantation↗

Clinical and economic impact of diabetes mellitus on percutaneous and surgical treatment of multivessel coronary disease patients: insights from the Arterial Revascularization Therapy Study (ARTS) trial.

BACKGROUND: Our aims were to compare coronary artery bypass grafting (CABG) and stenting for the treatment of diabetic patients with multivessel coronary disease enrolled in the Arterial Revascularization Therapy Study (ARTS) trial and to determine the costs of these 2 treatment strategies. METHODS AND RESULTS: Patients (n=1205) were randomly assigned to stent implantation (n=600; diabetic, 112) or CABG (n=605; diabetic, 96). Costs per patient were calculated as the product of each patient's use of resources and the corresponding unit costs. Baseline characteristics were similar between the groups. At 1 year, diabetic patients treated with stenting had the lowest event-free survival rate (63.4%) because of a higher incidence of repeat revascularization compared with both diabetic patients treated with CABG (84.4%, P<0.001) and nondiabetic patients treated with stents (76.2%, P=0.04). Conversely, diabetic and nondiabetic patients experienced similar 1-year event-free survival rates when treated with CABG (84.4% and 88.4%). The total 1-year costs for stenting and CABG in diabetic patients were $12 855 and $16 585 (P<0.001) and in the nondiabetic groups, $10 164 for stenting and $13 082 for surgery. CONCLUSIONS: Multivessel diabetic patients treated with stenting had a worse 1-year outcome than patients assigned to CABG or nondiabetics treated with stenting. The strategy of stenting was less costly than CABG, however, regardless of diabetic status.

Cerebrovascular Disorders↗

Evaluation of the models available for the prediction of pressure drop in venturi scrubbers.

The major running cost derived from the operation of venturi scrubbers is pressure drop. In the present study, the predictions of different models are compared to experimental data from venturi scrubbers of different sizes (throat diameter from 1.9 to 16cm), geometries, operating variables and liquid injection arrangements. As a result, it is concluded that most of the models must be used with caution. Much attention must be paid to the validity of the assumptions employed in the mathematical models. The equations proposed by Calvert [Scrubbing, Air Pollution, 3rd Edition, Vol. IV, Academic Press, New York, 1982], Yung et al. [JAPCA 27 (1977) 348] or Hesketh [Atomization and cloud behaviour in wet scrubbers, in: Proceedings of the US-USSR Symposium Control Fine Particulate Emissions 1974, San Francisco, 15-18 January 1974] produce good results only in very specific situations. The model proposed by Boll [Ind. Eng. Chem. Fundam. 12 (1973) 40] is simple, easy to compute and agrees reasonably well with the experimental data. Unfortunately, it cannot predict the effect of different liquid injection arrangements. The model by Azzopardi and coworkers [Filtr. Sep. 21 (1984) 196; Trans. IchemE. 69B (1991) 237; Chem Eng. J. 67 (1997) 9] was the only one to give good predictions for all the range of variables studied. On the other hand, this model is not simple and requires from the engineer an additional effort in terms of computation. In order to apply this model to the rectangular geometry, the concept of hydraulic equivalent diameter was used.

Aerosols↗

Secoisolariciresinol dehydrogenase purification, cloning, and functional expression. Implications for human health protection.

Matairesinol is a central precursor in planta in the biosynthesis of numerous lignans, including that of the important antiviral and anticancer agent, podophyllotoxin. In this study, the approximately 32-kDa NAD-dependent secoisolariciresinol dehydrogenase, which catalyzes the enantiospecific conversion of (-)-secoisolariciresinol into (-)-matairesinol in Forsythia intermedia, was purified >6,000-fold to apparent homogeneity. The 831-base pair cDNA clone encoding this 277-amino acid protein was next obtained from a library constructed from F. intermedia stem tissue, whose fully functional recombinant protein, produced by expression of this cDNA in Escherichia coli, catalyzed the same enantiospecific conversion via the corresponding lactol intermediate. A homologous secoisolariciresinol dehydrogenase gene was also isolated from a Podophyllum peltatum rhizome cDNA library, whose 834-base pair cDNA clone encoded a 278-amino acid protein with a calculated molecular mass of approximately 32 kDa. Expression of this protein in E. coli produced a fully functional recombinant protein that also catalyzed the enantiospecific conversion of (-)-secoisolariciresinol into (-)-matairesinol via the intermediary lactol. Various kinetic parameters were defined and established conversion of the intermediary lactol as being rate-limiting. With this overall enzymatic conversion now unambiguously defined, the entire biochemical pathway to the lignans, secoisolariciresinol and matairesinol, has been elucidated. Last, both secoisolariciresinol and matairesinol are metabolized in the gut of mammals, following digestion of high fiber dietary grains, seeds, and berries, into the so-called "mammalian" lignans, enterodiol and enterolactone, respectively; these in turn confer significant protection against the onset of breast and prostate cancers.

Alcohol Oxidoreductases↗

Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-dimensional intravascular ultrasound study.

BACKGROUND: Restenosis remains an important limitation of interventional cardiology. Therefore, we aimed to determine the safety and efficacy of sirolimus (a cell-cycle inhibitor)-coated BX Velocity stents. METHODS AND RESULTS: Thirty patients with angina pectoris were electively treated with 2 different formulations of sirolimus-coated stents (slow release [SR], n=15, and fast release [FR], n=15). All stents were successfully delivered, and patients were discharged without clinical complications. Independent core laboratories analyzed angiographic and 3D volumetric intravascular ultrasound data (immediately after procedure and at 4-month follow-up). Eight-month clinical follow-up was obtained for all patients. There was minimal neointimal hyperplasia in both groups (11.0+/-3.0% in the SR group and 10.4+/-3.0% in the FR group, P:=NS) by ultrasound and quantitative coronary angiography (in-stent late loss, 0.09+/-0.3 mm [SR] and -0.02+/-0.3 mm [FR]; in-lesion late loss, 0.16+/-0.3 mm [SR] and -0.1+/-0.3 mm [FR]). No in-stent or edge restenosis (diameter stenosis >or=50%) was observed. No major clinical events (stent thrombosis, repeat revascularization, myocardial infarction, or death) had occurred by 8 months. CONCLUSIONS: The implantation of sirolimus-coated BX Velocity stents is feasible and safe and elicits minimal neointimal proliferation. Additional placebo-controlled trials are required to confirm these promising results.

Aged↗

Management challenges on small-scale gold mining activities in Brazil.

This article presents a focused study of environmental management in small-scale gold mining, called garimpo, at the Tapajós River in the Amazon basin (Brazil). Environmental management is necessary in this very important area not only for Brazil but for the general world welfare. The fact that this is a very dispersed area, with a very low economic and education level, complicates the issues. Added to these factors are legislation, administration, and control processes which are shown in their historical, technical, health, and economic aspects. Using systemic integration, the article describes how the inherent interests of each part directly or indirectly involved may be articulated to result in self-control. The same approach reveals also the potential conflicts. Some existent proposals are analyzed with regard to the extent to which they can work, given the described aspect.

Brazil↗

Geographical miss during catheter-based intracoronary beta-radiation: incidence and implications in the BRIE study. Beta-Radiation In Europe.

OBJECTIVES: We sought to determine the incidence and causes of geographical miss (GM) and to evaluate its impact on edge restenosis after intracoronary beta-radiation therapy. BACKGROUND: Edge restenosis is a limitation of intracoronary beta-radiation therapy. Geographical miss is the situation in which the radiation source does not fully cover the injured segment and may lead to edge restenosis. METHODS: We analyzed 175 vessels treated according to the Beta-Radiation In Europe (BRIE) study protocol. The effective irradiated segment (EIRS) and both edges were studied with quantitative coronary angiography. The edges of the EIRS that were injured constituted the GM edges. Restenosis was defined as diameter stenosis >50% at follow-up. Geographical miss was determined by simultaneous electrocardiographic-matched, side-by-side projection of the source and balloons deflated at the injury site, in identical angiographic projections surrounded by contrast. RESULTS: Geographical miss affected 41.2% of the edges and increased edge restenosis significantly compared with non-GM edges (16.3% vs. 4.3%, respectively, p = 0.004). Restenosis was increased both in the proximal (p = 0.05) and distal (p = 0.02) GM edges compared with noninjured edges. Geographical miss associated with stent injury significantly increased edge restenosis (p = 0.006), whereas GM related to balloon injury did not significantly increase edge restenosis (p = 0.35). The restenosis in the EIRS was similar between vessels with and without GM (24.3% and 21.6%, respectively, p = 0.8). CONCLUSIONS: Geographical miss is strongly associated with restenosis at the edges of the EIRS. This effect is more prominent when caused by stenting. Geographical miss does not increase restenosis in the EIRS.

Adult↗

Effects of L-arginine and furosemide on blood pressure and renal function in volume-expanded rats.

1. The aim of the present study was to investigate the effects of L-arginine (L-Arg) on blood pressure and water and electrolyte excretion in control and extracellular fluid volume-expanded rats (10% bodyweight with 0.9% NaCl) and to determine whether diuretic treatment with furosemide (FUR) can be optimized by the administration of L-Arg in this model. 2. Both groups of animals were anaesthetized, divided into groups and treated with either 7.5 mg/kg FUR, 250 mg/kg L-Arg, 1 mg/kg NG-nitro-L-arginine methyl ester (L-NAME), FUR + L-NAME or FUR + L-Arg. Mean arterial pressure (MAP), diuresis, natriuresis and kaliuresis were determined. 3. Extracellular fluid volume expansion induced no changes in MAP in control and volume-expanded rats (92+/-6 vs 100+/-8 mmHg, respectively). The hypotension induced by FUR in control and volume-expanded rats (69+/-7 and 76+/-5 mmHg, respectively) was significantly (P < 0.01) enhanced by the administration of L-Arg (54+/-3 and 64+/-3 mmHg, respectively). 4. Injection of L-NAME increased MAP and diminished diuresis, natriuresis and kaliuresis in both groups. 5. Furosemide-induced water and electrolyte excretion was blunted by the administration of L-NAME. 6. The combination of L-Arg + FUR increased diuresis induced by FUR alone (control rats: 29.33+/-1.68 vs 12.91+/- 0.41 microL/min per 100 g, respectively; volume-expanded rats: 248.5+/-25.4 vs 112,6+/-8.3 microL/min per 100 g, respectively; P < 0.01). 7. The administration of the combination of L-Arg + FUR promoted a decrease in the sodium/water excretion ratio compared with the administration of FUR alone (control rats: 0.230+/-0.018 vs 0.45+/-0.03, respectively, P < 0.001; volume-expanded rats: 0.091+/-0.010 vs 0.22+/-0.03, respectively, P < 0.01). 8. The potassium/water excretion rate induced by FUR alone and in the presence of L-Arg followed a pattern similar to that seen for natriuresis (control rats: 0.35+/-0.05 vs 0.20+/-0.05 microEq/min per 100 g, respectively; volume-expanded rats: 0.045+/-0.008 vs 0.014+/-0.003 microEq/min per 100 g, respectively; P < 0.01). 9. The decrease in the electrolyte/water excretion ratio observed with FUR + L-Arg in volume-expanded rats was greater than in control animals. 10. The results of the present study show that the administration of FUR with L-Arg contributes to enhanced hypotensive and diuretic effects of FUR, thus diminishing the relative electrolyte excretion in normal conditions and in extracellular fluid volume expansion.

Animals↗

Indirect evidence for a role of a subpopulation of activated neutrophils in the remodelling process after percutaneous coronary intervention.

AIM: Leukocytes have been implicated in restenosis following percutaneous transluminal coronary angioplasty. We investigated the link between the activated status of circulating neutrophils and restenosis after angioplasty. METHODS AND RESULTS: The population of 108 patients with single, de novo lesions located in native coronary arteries were treated with elective balloon angioplasty (n=44) or stenting (n=64). Pre-, post-procedure and 6-month follow-up, angiograms were analysed by an independent core laboratory. Blood samples were collected immediately before treatment and the antigen CD66, which is specifically expressed by activated neutrophils, was measured. Overall, the average expression of CD66 was 6.4+/-3.6 of mean fluorescence intensity. In the stepwise linear regression model, which included biological, clinical and angiographic variables, absolute gain showed a direct association (P<0.001) with relative late loss (relative late loss=absolute late loss/pre-procedure reference diameter), whereas CD66 expression was inversely associated with relative late loss (P=0.004). CD66 expression also showed an inverse association with relative late loss in the balloon angioplasty treated patients (P=0.002, beta=-0.49). In the stent subgroup, only reference vessel diameter and acute gain were independent predictors of relative late loss. CONCLUSION: Our results confirm the beneficial role of activated neutrophils pre-procedure in the restenotic process after balloon angioplasty. The lack of a relationship between CD66 expression by neutrophils and relative late loss after stenting suggests that this leukocyte may be involved in the remodelling process.

Angioplasty, Balloon, Coronary↗

Glutathione-induced conversion of pentavalent antimony to trivalent antimony in meglumine antimoniate.

The standard treatment of human leishmaniases involves the use of pentavalent antimony [Sb(V)] compounds, including meglumine antimoniate. The mode of action of these compounds has not been fully elucidated. The possibility that Sb(III) is involved has been suggested; however, the biomolecule that may induce the conversion of Sb(V) to Sb(III) has not yet been identified. In the present study, we investigated both the ability of reduced glutathione (GSH) to promote the reduction of Sb(V) into Sb(III) in meglumine antimoniate and the effects of pH and temperature on this transformation. GSH did promote the reduction of Sb(V) into Sb(III) in a dose-dependent manner. When GSH and meglumine antimoniate were incubated together at a GSH/Sb molar ratio superior or equal to 5:1, all antimony was encountered in the reduced form, indicating a stoichiometry of 5:1 between GSH and Sb(V) in the reaction. The reaction between Sb(V) and GSH was favored at an acidic pH (pH 5) and an elevated temperature (37 degrees C), conditions found within the phagolysosome, in which Leishmania resides. For instance, about 30% of the Sb(V) (concentration, 2mM) was converted to Sb(III) following incubation for 3 days with 10 mM GSH at pH 5 and 37 degrees C. Our data support the hypothesis that Sb(V) would be converted by GSH, or a related thiol compound, to more toxic Sb(III) in the phagolysosome of macrophages.

Antimony↗