Effect of human trabecular bone composition on its electrical properties.

Mechanical properties of bone are determined not only by bone mineral density (BMD), but also by tissue trabecular structure and organic composition. Impedance spectroscopy has shown potential to diagnose trabecular bone BMD and strength, however, the relationships between organic composition and electrical and dielectric properties have not been systematically investigated. To investigate these issues organic composition of 26 human trabecular bone samples harvested from the distal femur and proximal tibia was determined and compared with relative permittivity, loss factor, conductivity, phase angle, specific impedance and dissipation factor measured at wide range (50 Hz to 5 MHz) of frequencies. A strong linear correlation was found between the relative permittivity at 1.2 MHz and trabecular bone fat content (r = -0.85, p<0.01, n=26). On the other hand, relative permittivity measured at 200 Hz served as a good predictor of water content (r = 0.83). Phase angle, specific impedance and especially conductivity were strongly related to the trabecular bone dry density and water content (|r| > or = 0.69). Variation in bone tissue collagen content was strongly related to the relative permittivity measured at 1.2 MHz (r = 0.64), but only moderately to other parameters. Glycosaminoglycan content showed no significant relations with any investigated electrical parameters. The present study indicates that if the trabecular bone composition is known, the relationships presented in this study could facilitate calculation of current field distribution, e.g. during electrical stimulation of osteogenesis. On the other hand, our results suggest that permittivity measured at low (<1 kHz) or high (>100 kHz) frequencies could be used, e.g. during implant surgery, for prediction of trabecular bone water or fat contents, respectively.

Adipose Tissue↗

Prediction of mechanical properties of trabecular bone using quantitative MRI.

Techniques for quantitative magnetic resonance imaging (MRI) have been developed for non-invasive estimation of the mineral density and structure of trabecular bone. The R*(2) relaxation rate (i.e. 1/T*(2)) is sensitive to bone mineral density (BMD) via susceptibility differences between trabeculae and bone marrow, and by binarizing MRI images, structural variables, such as apparent bone volume fraction, can be assessed. In the present study, trabecular bone samples of human patellae were investigated in vitro at 1.5 T to determine the ability of MRI-derived variables (R*(2) and bone volume fraction) to predict the mechanical properties (Young's modulus, yield stress and ultimate strength). Further, the MRI variables were correlated with reference measurements of volumetric BMD and bone area fraction as determined with a clinical pQCT system. The MRI variables correlated significantly (p < 0.01) with the mechanical variables (r = 0.32-0.46), BMD (r = 0.56) and bone structure (r = 0.51). A combination of R*(2) and MRI-derived bone volume fraction further improved the prediction of yield stress and ultimate strength. Although pQCT showed a trend towards better prediction of the mechanical properties, current results demonstrate the feasibility of combined MR imaging of marrow susceptibility and bone volume fraction in predicting the mechanical strength of trabecular bone and bone mineral density.

Adult↗

Interrelationships between electrical properties and microstructure of human trabecular bone.

Microstructural changes, such as reduction of trabecular thickness and number, are characteristic signs of osteoporosis leading to diminished bone strength. Electrical and dielectric parameters might provide diagnostically valuable information on trabecular bone microstructure not extractable from bone mineral density measurements. In this study, structural properties of human trabecular bone samples (n=26) harvested from the distal femur and proximal tibia were investigated using the computed microtomography (microCT) technique. Quantitative parameters, e.g. structural model index (SMI) or trabecular bone volume fraction (BV/TV), were calculated. In addition, the samples were examined electrically over a wide frequency range (50 Hz-5 MHz) using a two-electrode impedance spectroscopy set-up. Relative permittivity, loss factor, conductivity, phase angle, specific impedance and dissipation factor were determined. Significant linear correlations were obtained between the dissipation factor and BV/TV or SMI (|r| 0.70, p<0.01, n=26). Principal component analyses, conducted on electrical and structural parameters, revealed that the high frequency principal component of the dissipation factor was significantly related to SMI (r=0.72, p<0.01, n=26). The linear combination of high and low frequency relative permittivity predicted 73% of the variation in BV/TV. To conclude, electrical and dielectric parameters of trabecular bone, especially relative permittivity and dissipation factor, were significantly and specifically related to a trabecular microstructure as characterized with microCT. The data gathered in this study constitute a useful basis for theoretical and experimental work towards the development of impedance spectroscopy techniques for detection of bone quality in vitro or in special cases of open surgery.

Bone Density↗

Prediction of mechanical properties of human trabecular bone by electrical measurements.

In trabecular bone, the interrelationships of electrical and dielectric properties with mechanical characteristics are poorly known. Information on these relations is crucial for evaluation of the diagnostic potential of impedance techniques. In this study, electrical and dielectric properties, i.e. permittivity, conductivity, phase angle, loss factor, specific impedance and dissipation factor of human trabecular bone samples (n=26, harvested from the distal femur and proximal tibia) were characterized in a wide frequency range (50 Hz-5 MHz). Mechanical properties, i.e. Young's modulus, ultimate strength, yield stress, yield strain and resilience of the samples (n=20) were determined by using destructive compressive testing. Subsequently, measurements of electrical and dielectric properties were repeated after mechanical testing. The measurements were also repeated for the control samples (n=6) that were not mechanically tested. Electrical, dielectric or mechanical properties showed no significant differences between the intact femoral and tibial samples. The electrical and dielectric parameters as well as the linear correlations between the dielectric and electrical parameters with mechanical parameters were strongly frequency dependent. At the frequency of 1.2 MHz, the relative permittivity showed the strongest linear correlations with the Young's modulus (r=0.71, p<0.01, n=20) and ultimate strength (r=0.73, p<0.01, n=20). Permittivity and dissipation factor showed statistically significant changes after mechanical testing. Our results suggest that the measurements of low frequency electrical and dielectric properties may provide information on the mechanical status of trabecular bone and, possibly, may even help to diagnose bone microdamage. In the future, these measurement techniques may be further developed for use during open surgery, such as bone grafting or total hip replacement surgery.

Algorithms↗

Dual energy x-ray laser measurement of calcaneal bone mineral density.

In dual energy x-ray absorptiometry (DXA) the photon attenuation is assumed to be similar in soft tissue overlying, adjacent to and inside the measured bone. In the calcaneal dual energy x-ray laser (DXL) technique, this assumption is not needed as attenuation by soft tissues at the local bone site is determined by combining DXA and heel thickness measurements. In the present study, 38 subjects were measured with DXL Calscan, Lunar PIXI and Lunar DPX-IQ DXA instruments and Hologic Sahara ultrasound instrument, and the performance and agreement of the instruments were analysed. Furthermore, numerical simulations on the effect of non-uniform fat-to-lean tissue ratio within soft tissue in heel were conducted. In vivo short-term precision (CV%, sCV%) of DXL Calscan (1.24%, 1.48%) was similar to that of Lunar PIXI (1.28%, 1.60%). Calcaneal areal bone mineral densities (BMD, g cm(-2)) measured using DXL Calscan and Lunar PIXI predicted equally well variations in BMD of femoral neck (r2 = 0.63 and 0.52, respectively) or lumbar spine (r2 = 0.61 and 0.64, respectively), determined with Lunar DPX-IQ. BMD values measured with DXL Calscan were, on average, 19% lower (p < 0.01) than those determined with Lunar PIXI. Interestingly, the difference in BMD values between instruments increased as a function of body mass index (BMI) (r2 = 0.17, p < 0.02) or heel thickness (r2 = 0.37, p < 0.01). Numerical simulations suggested that the spatial variation of soft tissue composition in heel can induce incontrollable inaccuracy in BMD when measured with the DXA technique. Theoretically, in contrast to DXA instruments, elimination of the effect of non-uniform soft tissue is possible with DXL Calscan.

Absorptiometry, Photon↗

Electrical and dielectric properties of bovine trabecular bone--relationships with mechanical properties and mineral density.

Interrelationships of trabecular bone electrical and dielectric properties with mechanical characteristics and density are poorly known. While electrical stimulation is used for healing fractures, better understanding of these relations has clinical importance. Furthermore, earlier studies have suggested that bone electrical and dielectric properties depend on the bone density and could, therefore, be used to predict bone strength. To clarify these issues, volumetric bone mineral density (BMDvol), electrical and dielectric as well as mechanical properties were determined from 40 cylindrical plugs of bovine trabecular bone. Phase angle, relative permittivity, loss factor and conductivity of wet bovine trabecular bone were correlated with Young's modulus, yield stress, ultimate strength, resilience and BMDvol. The reproducibility of in vitro electrical and dielectric measurements was excellent (standardized coefficient of variation less than 1%, for all parameters), especially at frequencies higher than 1 kHz. Correlations of electrical and dielectric parameters with the bone mechanical properties or density were frequency-dependent. The relative permittivity showed the strongest linear correlations with mechanical parameters (r > 0.547, p < 0.01, n = 40, at 50 kHz) and with BMDvol (r = 0.866, p < 0.01, n = 40, at 50 kHz). In general, linear correlations between relative permittivity and mechanical properties or BMDvol were highest at frequencies over 6 kHz. In addition, a significant site-dependent variation of electrical and dielectric characteristics, mechanical properties and BMDvol was revealed in bovine femur (p < 0.05, Kruskall-Wallis H-test). Based on the present results, we conclude that the measurement of electrical and dielectric properties provides quantitative information that is related to bone quantity and quality.

Animals↗