Computer-aided classification of mammographic masses and normal tissue: linear discriminant analysis in texture feature space.

We studied the effectiveness of using texture features derived from spatial grey level dependence (SGLD) matrices for classification of masses and normal breast tissue on mammograms. One hundred and sixty-eight regions of interest (ROIS) containing biopsy-proven masses and 504 ROIS containing normal breast tissue were extracted from digitized mammograms for this study. Eight features were calculated for each ROI. The importance of each feature in distinguishing masses from normal tissue was determined by stepwise linear discriminant analysis. Receiver operating characteristic (ROC) methodology was used to evaluate the classification accuracy. We investigated the dependence of classification accuracy on the input features, and on the pixel distance and bit depth in the construction of the SGLD matrices. It was found that five of the texture features were important for the classification. The dependence of classification accuracy on distance and bit depth was weak for distances greater than 12 pixels and bit depths greater than seven bits. By randomly and equally dividing the data set into two groups, the classifier was trained and tested on independent data sets. The classifier achieved an average area under the ROC curve, Az, of 0.84 during training and 0.82 during testing. The results demonstrate the feasibility of using linear discriminant analysis in the texture feature space for classification of true and false detections of masses on mammograms in a computer-aided diagnosis scheme.

Biophysical Phenomena

Invasive lobular carcinoma: sonographic appearance and role of sonography in improving diagnostic sensitivity.

PURPOSE: To characterize the ultrasonographic (US) appearance of invasive lobular carcinoma (ILC) and to assess the potential role of US in the earlier detection of ILC. MATERIALS AND METHODS: US scans in 19 patients with ILC were retrospectively studied for the presence of a mass, characteristics of the margins, internal echogenicity, and attenuation effects. RESULTS: US showed masses in 13 of the 19 patients (68% sensitivity). Irregularly marginated masses with heterogeneous internal echoes and acoustic attenuation were present in seven patients. A variety of US findings, mimicking a benign lesion, were noted in the other six patients. US sensitivity in the detection of small cancers (< 1 cm) was 25% (one of four patients). Mammographic sensitivity in the detection of ILC in this series was 89% (17 of 19 patients). CONCLUSION: ILC has a variety of US appearances. US was insensitive and nonspecific in the diagnosis of ILC, especially for small cancers. A negative US result should not deter surgical biopsy if indicated by mammographic findings or clinical findings.

Breast

Dynamic three-dimensional imaging with partial k-space sampling: initial application for gadolinium-enhanced rate characterization of breast lesions.

PURPOSE: To evaluate a method to monitor gadolinium enhancement patterns at magnetic resonance (MR) imaging with high temporal resolution and full coverage through both breasts. MATERIALS AND METHODS: In 12 patients with 13 masses, including nine carcinoma, nonenhanced three-dimensional MR imaging was performed with full-matrix resolution. At dynamic imaging, 32 serial passes were made during bolus administration of contrast material, and temporal resolution was reduced to 12 seconds by collecting the central (low spatial frequency) 32 x 16 or 16 x 16 phase-encode views. Full-matrix dynamic images were reconstructed by complementing central phase-encode data with precontrast data from peripheral high-spatial-frequency views. RESULTS: Results at time-course analysis with a mono-exponential saturation model indicated malignant lesions tend to show rapid (< 60 seconds) contrast change relative to benign masses and normal tissues. One cancer displayed an exceptionally slow contrast change (260 seconds). CONCLUSION: The technical objectives of full tissue coverage, rapid temporal sampling, and quantification of enhancement curves are met with this method for certain lesions (> 5 mm in largest diameter).

Adult

Bilateral breast cancer: early detection with mammography.

PURPOSE: To assess the contribution of mammography in the detection of cancer in the contralateral breast in women with bilateral breast cancer. MATERIALS AND METHODS: Mammograms and clinical records of 77 patients with bilateral breast cancer were reviewed in a retrospective study. RESULTS: The contralateral cancer was detected at mammography in 68 of 77 patients (88%) and identified at mammography alone in 50 patients (65%). No statistically significant differences in either mammographic detection rates or stage of the contralateral cancer were noted in patients younger than 50 years (n = 25) compared with those 50 years of age or older (n = 52). Cancers detected at annual screening mammography were of lower stage than cancers in unscreened patients. In the screened group, 41% of tumors were ductal carcinoma in situ alone and 23% were stage II or III, compared with 22% and 50%, respectively, in the unscreened group. CONCLUSION: Mammographic examination and follow-up in patients with unilateral breast cancer allow detection of the majority of contralateral breast cancers and earlier stage cancers.

Age Factors

Pure and mixed mucinous carcinoma of the breast: pathologic basis for differences in mammographic appearance.

OBJECTIVE: It is important to differentiate pure and mixed mucinous carcinomas of the breast because the former have a more favorable prognosis. We correlate histopathologic findings with mammographic findings for 20 patients with pure or mixed mucinous carcinomas to determine differential characteristics and their pathologic basis. MATERIALS AND METHODS: We searched our pathology database of 2219 consecutive women with a diagnosis of breast cancer and found that 31 (1.4%) had mucinous carcinomas. Eleven women were excluded because the mammograms (n = 6) or the microscopic slides (n = 5) were not available. The remaining 20 women, who were 37-92 years old (mean, 64 years), were the subjects of the study. Their clinical records, mammograms, and microscopic slides were reviewed. Tumor size was based on the maximum mammographic diameter or measured diameter of the excised tumor. RESULTS: Seventeen patients (85%) had tumors that were mammographically apparent. Histopathologic review confirmed 15 pure mucinous tumors and five mixed mucinous tumors having an overall mean diameter of 3.4 cm. The pure-tumor group contained three incidentally detected tumors (all < or = 0.8 cm in diameter); six that had a circumscribed, lobular contour on mammograms (mean diameter, 3.6 cm); and six that had a poorly defined, irregular contour (mean diameter, 1.2 cm). One of the mammographically apparent small pure tumors contained histologically confirmed psammomatous microcalcifications. All pure tumors had microscopically evident circumscribed margins that could have accounted for the circumscribed mammographic appearance of the larger masses. All mixed tumors had mammographically and histologically evident irregular margins because of the associated fibrosis and infiltrative margins of the nonmucinous component (mean diameter, 5.3 cm). CONCLUSION: There are differences in the mammographic appearances of pure and mixed mucinous carcinomas that have a histopathologic basis. Circumscribed, lobular margins on mammograms are characteristic of large pure tumors and are the result of their microscopically evident circumscribed margins and expansile growth pattern. Irregular margins on mammograms are more characteristic of mixed mucinous tumors, regardless of tumor size, and are attributable to the fibrotic and infiltrative nature of the nonmucinous component.

Adenocarcinoma, Mucinous

Breast cancer in the elderly patient: early detection with mammography.

PURPOSE: To determine the mammographic features and differences in stage of breast carcinomas in elderly women with malignancies detected with palpation or mammography at presentation. MATERIALS AND METHODS: The mammograms and clinical records of 60 patients (aged 75 years or older) with 62 breast carcinomas, detected during 40 consecutive months, were retrospectively reviewed. A variety of dedicated devices and processing equipment were used. The histologic features, mammographic appearance, mode of detection, and stage of disease were determined. Statistically significant differences between subgroups were calculated with the Student t and chi 2 tests. RESULTS: Sixty cancers (97%) were seen on mammograms. Seventeen tumors detected with annual mammography differed significantly from the 45 carcinomas in nonscreened patients in diameter (1.1 vs 2.1 cm; P < .0005) and stage (14 minimal [82%] of 17 tumors vs 15 minimal [33%] of 45 tumors; P < .0005). Thirty-five nonpalpable malignancies differed significantly from 27 palpable masses in diameter (1.2 vs 2.3 cm; P = .01) and stage (25 tumors minimal [71%] vs four tumors minimal [15%]; P < .0005). CONCLUSION: Screening mammography enabled detection of statistically significantly smaller and earlier-stage tumors, most of which were minimal disease.

Age Factors

Breast thickness in routine mammograms: effect on image quality and radiation dose.

OBJECTIVE: The purpose of this study was to compare the thickness of the compressed breast between mediolateral oblique and craniocaudal mammograms and to relate these differences in thickness to image quality and radiation dose. These differences may partially explain why some subtle tumors are better visualized on the craniocaudal view. SUBJECTS AND METHODS: The study population consisted of 250 paired mediolateral oblique and craniocaudal mammograms obtained on one mammographic unit by seven certified mammography technologists during a 2-month period. Only women with breast implants, prior lumpectomy and radiotherapy, or chest wall deformity were excluded. The digital readout of compressed breast thickness and applied compression force was recorded. Mammographic positioning was assessed using standard criteria. Absorbed radiation dose at different thicknesses was measured with a BR-12 breast phantom. Image quality differences for geometric unsharpness and contrast were calculated for the observed breast thickness differences between mediolateral oblique and craniocaudal mammograms. RESULTS: The mean thickness of the compressed breast on the craniocaudal view was less than the mean thickness on the mediolateral oblique view (4.4 versus 4.8 cm, p < .0001) despite the greater force used to compress the breast for mediolateral oblique than for craniocaudal views (93 versus 86 newtons, p < .0001). The breast thickness on the mediolateral oblique view exceeded that on the craniocaudal view in 98 (84%) of 117 pairs that differed in thickness by 5 mm or more and 46 (94%) of 49 pairs that differed by 10 mm or more (p < .0001). Geometric unsharpness increased by 8% and 19% when a 4.4-cm-thick breast was compared to a 4.8- and 5.4-cm-thick breast, respectively. A 5% and 12% loss of contrast was noted when a 4.4-cm-thick breast was compared to a 4.8- and 5.4-cm-thick breast. Mean glandular radiation dose at 4.4, 4.8, and 5.4 cm was 1.40, 1.70, and 2.33 mGy, respectively. CONCLUSION: The compressed breast is 8% thicker on mediolateral oblique than on craniocaudal mammograms, a small but statistically significant difference. This difference results in a small loss of spatial and contrast resolution on the mediolateral oblique views and an increase in radiation dose. These image quality differences may partially explain why some subtle carcinomas are better visualized on the craniocaudal view.

Adult

Detection of breast cancer in women after augmentation mammoplasty using fluorine-18-fluorodeoxyglucose-PET.

UNLABELLED: The purpose of this study was to determine the feasibility of FDG-PET imaging in women with silicone implant augmentation mammoplasties where mammographic detection of breast cancers is challenging due to the implants' radiodensity, which can obscure tumor visualization. METHODS: FDG-PET imaging was performed in two women with augmentation mammoplasties and small palpable breast abnormalities. Mammograms with and without breast displacement were also performed. RESULTS: PET clearly demonstrated focal FDG accumulation in the suspicious breasts, corresponding to tumors of less than 1.5 cm in diameter. There was no degradation of image quality by the implants and no need for breast displacement views. By contrast, implant displacement mammograms were necessary to fully delineate the tumors. CONCLUSION: While mammograms with displacement views represent the initial choice for imaging the augmented breast, FDG-PET can image tumors in the augmented breast without implant displacement and without obvious degradation of image quality by the implant. FDG-PET warrants additional evaluation as an adjunctive study in the augmented breast, particularly when displacement mammographic views are not adequate or are impossible to perform due to peri-implant capsule formation.

Adult

Paget disease of the nipple: radiologic-pathologic correlation.

PURPOSE: To correlate the range of clinical presentations with mammographic and histologic findings in patients with Paget disease of the nipple. MATERIALS AND METHODS: The clinical, pathologic, and mammographic records of 58 patients who had biopsy-proved Paget disease of the nipple were retrospectively reviewed. The results of two previous studies were also included. RESULTS: Among 34 patients who had typical findings of Paget disease, the mammograms of 17 (50%) showed normal findings, those of 10 (29%) showed nipple, areolar, or subareolar abnormalities, and those of seven (21%) showed evidence of masses or calcifications. Of the mammograms of 24 women with Paget disease but without clinical findings, 19 (79%) showed evidence of suspicious masses or calcifications, four (17%) showed nipple or areolar abnormalities, and one was negative. CONCLUSION: Nonspecific findings of nipple-areolar complex thickening should be correlated with findings at breast physical examination to confirm or exclude Paget disease.

Adult

Tubular carcinoma of the breast: mode of presentation, mammographic appearance, and frequency of nodal metastases.

OBJECTIVE: Tubular carcinoma of the breast is a distinct, well-differentiated histologic subtype of infiltrative adenocarcinoma. The purpose of this study was to determine the typical mode of presentation, mammographic appearance, and frequency of metastases to the axillary lymph nodes. MATERIALS AND METHODS: We retrospectively analyzed the clinical records, mammograms, and histologic slides of 20 cases of proved tubular carcinoma of the breast in 20 women. These patients were identified by computerized search of our pathology data base from 1984 to 1993. Histologic findings were reviewed in all cases and correlated with the mammographic findings. RESULTS: Thirteen (65%) of the 20 women had impalpable tubular cancers discovered on screening mammograms. Seven patients (35%) had mammography because of a palpable tumor. Abnormalities were seen on mammograms in 16 patients (80%). These consisted of a mass alone in 13 (65%), a mass with microcalcifications in two (10%), and calcifications associated with architectural distortion and asymmetric density in one (5%). Most masses (11/15, 73%) were irregular or spherical and had spiculated margins. The size of the masses ranged from 3 to 19 mm (median, 8 mm). Metastatic carcinoma was found in the axillary lymph nodes of four (29%) of 14 patients who had axillary lymph node dissections, three of whom had a primary tumor 1 cm or less in diameter. CONCLUSION: Tubular cancers were most frequently detected as impalpable abnormalities seen on mammograms, emphasizing the importance of screening mammography. However, tubular carcinomas did not have a unique appearance on mammograms that would allow differentiation from other carcinomas. Lymph node metastases were more common than has been previously reported for this type of tumor, indicating that axillary lymph node dissections should continue to be performed.

Adenocarcinoma

The role of fine-needle aspiration and pneumocystography in the treatment of impalpable breast cysts.

Prior studies have suggested that the recurrence rate is lower in breast cysts treated by pneumocystography (injection of air into cyst cavities after cyst aspiration) than in cysts treated by fine-needle aspiration alone. To determine if this is the case for impalpable breast cysts, we reviewed the hospital records and mammograms of 38 women with 41 impalpable cysts. Mammograms obtained immediately after aspiration show that pneumocystography was successful in 18 and unsuccessful in 20 of the 41 cysts. Four cysts were excluded from the study: one cyst that recurred after aspiration and was sampled by biopsy and three cysts for which immediate post-aspiration mammograms were unavailable but which had recurred or persisted 3 years after aspiration. Review of follow-up mammograms made 4 months to 3 years after the aspiration showed that three (17%) of 18 cysts in the group with successful pneumocystography recurred and 11 (58%) of 19 cysts in the unsuccessful group recurred (p = .02). No difference was found in the number of recurrent cysts in relation to estrogen therapy or menopausal status. Our results indicate that impalpable breast cysts treated by pneumocystography are less likely to recur than are cysts treated by aspiration alone.

Adult

Solitary breast papilloma: comparison of mammographic, galactographic, and pathologic findings.

OBJECTIVE: Our purpose was to determine the mammographic/galactographic features of solitary breast papillomas and to correlate these features with the pathologic findings. MATERIALS AND METHODS: Retrospective review of pathology files revealed 72 women in whom breast biopsy reports described a solitary papilloma. All patients with additional pathologic abnormalities were excluded from this study. Patients meeting the pathologic criteria and for whom mammograms, galactograms, or both were available and had been obtained within 6 months before biopsy were included. Twenty-four women met these criteria and form the basis of this study. Presenting clinical signs and symptoms were reviewed. Abnormal mammographic/galactographic findings were correlated with pathologic features. RESULTS: Nipple discharge was present in 21 (88%) of 24 patients, two (8%) of 24 patients had abnormal findings on screening mammography, and one patient had a palpable mass that was visible on mammograms. Eight (42%) of 19 mammograms had abnormal findings, including dilated duct(s) in five cases (26%), nodules in two cases (11%), and microcalcifications in one case (5%). All technically adequate galactograms (13/15) had abnormal findings, with 12 (92%) of 13 showing an intraluminal filling defect. The other technically adequate galactogram (8%) showed only a solitary obstructed duct. Ductal dilatation was greatest at or central to the papilloma on 12 (92%) of 13 galactograms. Imaging features correlated well with the histologic findings. CONCLUSION: Patients with solitary papillomas most commonly have nipple discharge, normal mammographic findings, and a galactographic filling defect. Galactography is useful for localizing papillomas.

Adult

Ruptured gel-filled silicone breast implants: sonographic findings in 19 cases.

OBJECTIVE: The purpose of this study was to describe and illustrate the sonographic appearances of 19 ruptured silicone gel breast implants. MATERIALS AND METHODS: We retrospectively reviewed the sonograms of 16 patients with 19 ruptured silicone gel implants from two institutions. The ruptured implant was confirmed at surgery in 17 cases and by mammographic and clinical findings of a ruptured implant combined with biopsy findings of a silicone granuloma in two cases. Breast sonograms were available for review in all patients. The clinical presentation of each patient was recorded. The sonograms and mammograms were reviewed, and the findings were correlated with the surgical findings. In 16 of the 19 ruptured implants, mammographic findings suggested rupture, including lobulation of the contour of the implant and/or silicone extrusion into the breast parenchyma or axilla. In two ruptured implants, mammographic findings were normal, and in one case, no mammogram was available. In those three patients, palpable masses and clinical findings were suggestive of rupture. RESULTS: Sonography showed a unique echogenic appearance called echo-dense noise, in 17 of the 19 ruptured implants; in 10 of the 17, sonograms showed hypoechoic masses of extruded silicone also. In two ruptured implants, sonograms showed only the hypoechoic masses of extruded silicone gel. CONCLUSION: Our experience suggests that echogenic noise is a unique sonographic sign of ruptured silicone gel breast implants and may be caused by phase aberration related to the speed of sound being slower in silicone than in soft tissue.

Equipment Failure

Mammographic biopsy recommendations.

Breast biopsy recommendations are commonly made on the basis of mammographic findings. Benign breast biopsies secondary to false positive mammographic interpretation remain a major source of discussion. A review of recent series of biopsy results is presented and the factors influencing positive predictive value are discussed. Methods to improve mammographic specificity, including validity of certain mammographic signs such as mass density are summarized. Issues relating to lesions followed on mammography--including number of views, compliance, and patient anxiety--are also addressed.

Biopsy, Needle

Mammographic follow-up of low-suspicion lesions: compliance rate and diagnostic yield.

All recommendations for mammographic follow-up of low-suspicion lesions seen at mammography during a 6-month period were reviewed to establish compliance rate and eventual outcome. One hundred forty-four of 2,650 mammograms (5%) showed minimal abnormalities that warranted short-term and periodic mammographic follow-up. Rates of compliance at 4 months and at 1, 2, and 3 years were 88%, 71%, 60%, and 47%, respectively. Progressive mammographic change was found in 10 patients, only one of whom had a carcinoma. It was concluded that mammographic follow-up of low-suspicion lesions is a reasonable alternative to surgical biopsy, although patient compliance remains a significant problem.

Biopsy

Atypical hyperplasia of the breast: mammographic appearance and histologic correlation.

The mammograms and histologic slides of 58 cases of atypical hyperplasia (AH) of the breast were retrospectively reviewed to determine the geographic correlation (direct, near, or remote) between mammographic abnormalities (if present) and the histologic findings. A direct mammographic-histologic correlation was found in 24 of the 58 cases (41%), near correlation in 15 (26%), and remote correlation in 19 (33%). Clustered microcalcifications were the most common mammographic abnormality that was directly correlated with AH at histologic examination. Atypical ductal hyperplasia was much more frequently associated with a direct mammographic-histologic correlation than was atypical lobular hyperplasia (48% vs 9%). The authors conclude that, although no pathognomonic appearance of AH was discovered, mammographic abnormalities similar to those of small cancers could be directly correlated with histologic findings in 41% of cases. Since AH has been shown to be associated with a five- to tenfold increased risk of subsequent invasive carcinoma, frequent clinical and at least yearly mammographic follow-up is suggested once AH is discovered.

Adult