A critical evaluation of the acute systemic toxicity test for dental alloys using histopathologic criteria.

The A.D.A. acute systemic test for type II, class 11 materials defines compliance on the basis of fewer than 50% mortality at 2 weeks. Histopathologic criteria were developed from pilot study data to evaluate the effects of these materials. In this double blind study, the frequency of histopathological changes in lung, liver, small intestine, and kidney were rated at 2 and 5 weeks, for six dental crown and bridge alloys ranging from 44% to 97% (Au, Pt, and Pd). Two positive 360 mg/kg and 1 g/kg of cadmium and two negative, a blank capsule and untreated control groups were used. There was significant difference (chi square test, X2 = 0.95) between the positive and negative controls at 2 and 5 weeks. The lung, liver, kidney showed the highest level of histopathological changes. Significant changes occurred in the four tissues for all alloys at two and five weeks. At five weeks, alloys with a lower noble metal content (44-62%, Au, Pd, and Pt) elicited significant chronic changes, while higher noble metal content (78-97%) showed healing and no significant difference from the negative controls. Applying histopathologic criteria and statistical parameters independent examiners can examine experimental animals and arrive at conclusive and reproducible results.

Animals↗

Organic surface film contamination of Vitallium implants.

Conventional finishing and polishing techniques used to prepare Vitallium subperiosteal dental implant castings were found to produce low energy surfaces as measured by critical surface tension. Standard metallographic preparation gave slightly higher values. Glow discharge cleaning of both types of polished surface gave much higher critical surface tension values. This suggests the presence of an organic film after surface polishing of the implant which may later affect tissue reaction, in particular attachment, as has been noticed in related animal studies.

Adhesiveness↗

Tissue response to surface-treated tantalum implants: preliminary observations in primates.

Samples of capacitor grade tantalum were surface-treated by a variety of methods. These surface treatments allowed testing of the same basic material which was mill-finished, metallurgically polished, electrochemically oxidized, sintered with a porous surface, and glow-discharged. Surface characterization was accomplished by contact angle measurements, Scanning Electron Microscopy, energy-dispensed x-ray analysis, and internal reflection spectroscopy. Subsequent to characterization, the material was surgically implanted in the subperiosteal region of the mandible, the buccal mucosa, and the subcutaneous paravertebral region of the back of Macaca speciosa (stumptail monkey). The tissue reaction at intervals of up to three weeks was evaluated morphologically and ultrastructurally. Significant differences in tissue response were noted at the interfaces with glow-discharge-treated versus lower surface energy samples. Adjacent to the glow-discharge-treated implants, two distinct tissue zones were identified. Zone No. 1, nearest the implant, exhibited an increased cellularity. This consisted of 4-5 layers of highly active mesenchymal cells or fibroblast-like cells with spindle-shaped nuclei and prominent cytoplasmic features. At various foci along the interface, hyperchromatic nuclear forms were noted to project into the space left by removal of the implant. These observations, coupled with a predominance of intercellular ground-substance material and less collagen at the interface, may indicate some form of bioadhesion. The deeper Zone No. 2 was 2-3 times as thick consisted of typical fibroblastic cells with a lamellar configuration, bordered by an occasional delicate-lined space. Independent of implantation site or surface texture, all other implants showed occasional multinucleated giant cells and a decrease in the cellular character of Zone No. 1. Both zones were reduced in thickness and composed of more mature fibroblasts. Some specimens exhibited intracytoplasmic vacuolization. It may be concluded, therefore, that surface-free energy of the implanted specimens played a significant role in inducing differential tissue response to otherwise similar pure metal samples.

Animals↗

Cryosurgery of major and minor salivary gland: a light microscopic evaluation in the Rhesus monkey.

The minor salivary glands in the hard palate and the submandibular gland of the Rhesus monkey were subjected to a liquid nitrogen, direct-spray, one-cycle freeze. A 4-min freeze in the temperature range of -40 degrees C to -60 degrees C was used. The extent of tissue destruction was determined at intervals up to 1 year. Clinically relevant findings resulted and form the basis for subsequent studies by this group of investigators.

Animals↗

Vein valve transplant. Indications and results.

The vein valve transplant has, in our experience, subjectively relieved symptoms in the majority of patients. More importantly, elevated venous pressure has been decreased in most patients. Thus, patients exhibiting signs of venous insufficiency syndrome as well as elevated venous pressure and proven valvular incompetence should be considered candidates for vein valve transplants after an unsuccessful trial of medical management.

Follow-Up Studies↗

Stimulation of in vivo calcification using collagen membranes cultured with osteoblastic cells in vitro: a preliminary report.

Guided tissue regeneration (GTR) is a useful modality in the management of periodontal disease and for bone augmentation around osseointegrated implants. This study evaluated the in vivo use of atelocollagen membrane (AC) on which osteoblastic cells (OBCs) were cultured in vitro, for application as a GTR membranous material. Osteoblastic cells isolated in our laboratory from mouse calvaria formed a thin film on the AC in vitro which was easily manipulated after 21 days in culture. The AC and OBCs complex material (ACOB) was subjected to freezing and thawing and implanted in mouse subcutaneous tissue for the study of histologic events surrounding the implanted ACOB. Histologic findings in the subcutaneous tissue showed calcification on the ACOB at 28 days postimplantation, while no such finding was evident at the control site, where only AC without OBCs were grafted. The present study suggests the possibility of membrane calcification for GTR through ACOB produced by OBCs on an AC in vitro.

Animals↗

An in vivo evaluation of an osteoinductive implantable material produced by osteoblastic cells in vitro.

Osteoinductive implantable materials have been a subject of basic science research in clinical implantology. This study examined the osteoinductive effect of an implantable material produced by osteoblastic cells that were isolated in the laboratory from mouse calvaria. After 21 days in culture, osteoblastic cells formed a thin film that could be easily manipulated. This thin film was subjected to freezing and thawing and was implanted in mouse muscle tissue. Osteoblastic cells were strongly positive for alkaline phosphatase reactivity and Von Kossa stain in vitro. Collagen type I, osteocalcin (BGP), and alkaline phosphatase were identified at the immunohistochemical electron microscopic level. Histologic findings showed an osteoinductive effect of the implanted material. The results strongly suggest the possibility of producing an osteoinductive implantable material by culturing osteoblastic cells in vitro.

Alkaline Phosphatase↗