Novel CPR with periodic Gz acceleration.

The effects of periodic Gz acceleration (pGz) on cardiovascular function and hemodynamics were determined in a pig model of acute cardiopulmonary resuscitation (CPR). The application of pGz (horizontal head-to-foot oscillations) at 2 Hz increased cardiac output in fibrillated animals proportional to the amplitude of the applied acceleration force that plateaued at 0.7 G. Cardiac output in fibrillating animals was restored to 20% of the values obtained before fibrillation with pGz-CPR and arterial blood gas values were normal during this period. The central vascular pressure gradient driving blood flow was only about 6 mmHg, suggesting low vascular resistance during pGz-CPR. In another study, capillary blood flow was determined before and after pGz-CPR using colored microspheres. Capillary perfusion was detected in all tissue beds studied during pGz-CPR. Significant capillary blood flow was detected in the endocardium and brain stem during pGz-CPR that represented 39 and 197% of control values before fibrillation, respectively. Thus, the cardiac output during pGz-CPR was preferentially distributed to the myocardial and brain tissues. In a final group, animals were successfully resuscitated with return of spontaneous circulation (ROSC) after pGz-CPR for 15 min following cardiac fibrillation with a 3-min non-intervention period. Following ROSC, blood pressure was maintained at pre-arrest values for 2 h without any pharmacological or mechanical support. Arterial blood gases during the pGz-CPR and the ROSC periods were normal and not different from values obtained before fibrillation. None of the control animals (18 min of fibrillation without pGz-CPR) survived the experimental protocol and only two of these six animals briefly returned to spontaneous circulation (<20 min). In conclusion, experimental pGz-CPR produces cardiac output, capillary blood flow, and ventilation sufficient to maintain fibrillating animals for 18 min with ROSC for 2 h without support.

Acceleration↗

Cardiopulmonary monitoring at home: the CHIME monitor.

A new physiologic monitor for use in the home has been developed and used for the Collaborative Home Infant Monitor Evaluation (CHIME). This monitor measures infant breathing by respiratory inductance plethysmography and transthoracic impedance; infant electrocardiogram, heart rate and R-R interval; haemoglobin O2 saturation of arterial blood at the periphery and sleep position. Monitor signals from a representative sample of 24 subjects from the CHIME database were of sufficient quality to be clinically interpreted 91.7% of the time for the respiratory inductance plethysmograph, 100% for the ECG, 99.7% for the heart rate and 87% for the 16 subjects of the 24 who used the pulse oximeter. The monitor detected breaths with a sensitivity of 96% and a specificity of 65% compared to human scorers. It detected all clinically significant bradycardias but identified an additional 737 events where a human scorer did not detect bradycardia. The monitor was considered to be superior to conventional monitors and, therefore, suitable for the successful conduct of the CHIME study.

Cardiography, Impedance↗

Regional blood flow during periodic acceleration.

OBJECTIVE: To determine whether a motion platform that imparts noninvasive periodic acceleration (pGz) forces to the body causes systemic vasodilation and changes local organ blood flow. DESIGN: Prospective paired blocked design. SETTING: Medical center research laboratory. SUBJECTS: Juvenile Yorkshire pigs. INTERVENTIONS: Juvenile pigs (12 kg) were anesthetized, paralyzed, and placed on a motion platform that oscillated at a frequency of 4 Hz and a force of approximately 0.4 G. MEASUREMENTS AND MAIN RESULTS: Regional blood flows, as assessed by colored microspheres, increased during pGz relative to values obtained before pGz. Blood flow (mL.min-1.100 g-1) significantly increased to the epicardium (71%), endocardium (93%), cerebrum (183%), brain stem (177%), renal cortex (53%), ileal mucosa (69%), gastric antral mucosa (72%), and liver (86%). Spleen and skeletal muscle blood flow increased without statistical significance, 38% and 158% with pGz, relative to paired control values. Regional blood flows returned to baseline 10 mins after discontinuation of pGz, except in the myocardial layers, where blood flow remained significantly elevated. There was no difference compared with baseline in heart rate, arterial blood gases, and blood pressure, but serum nitrite concentration was significantly higher (58%) during pGz. In another series of animals, pGz increased pulmonary artery blood flow directly proportional to the magnitude of the applied acceleration force with frequency held constant. CONCLUSIONS: Periodic sinusoidal inertial forces in the spinal axis increase blood flow to tissues. The increased blood flow is reversible and may be caused by vasodilation secondary to local mediator release. These effects may be desirable in clinical conditions of low tissue oxygen delivery and perfusion.

Acceleration↗

Noninvasive motion ventilation (NIMV): a novel approach to ventilatory support.

A motion platform was developed that oscillates an animal in a foot-to-head direction (z-plane). The platform varies the frequency and intensity of acceleration, imparting periodic sinusoidal inertial forces (pG(z)) to the body. The aim of the study was to characterize ventilation produced by the noninvasive motion ventilator (NIMV) in animals with healthy and diseased lungs. Incremental increases in pG(z) (acceleration) with the frequency held constant (f = 4 Hz) produced almost linear increases in minute ventilation (VE). Frequencies of 2-4 Hz produced the greatest VE and tidal volume (VT) for any given acceleration between +/-0.2 and +/-0.8 G. Increasing the force due to acceleration produced proportional increases in both transpulmonary and transdiaphragmatic pressures. Increasing transpulmonary pressure by increasing pG(z) produced linear increases in VT, similar to spontaneous breathing. NIMV reversed deliberately induced hypoventilation and normalized the changes in arterial blood gases induced by meconium aspiration. In conclusion, a novel motion platform is described that imparts periodic sinusoidal acceleration forces at moderate frequencies (4 Hz) to the whole body in the z-plane. These forces, when properly adjusted, are capable of highly effective ventilation of normal and diseased lungs. Such noninvasive ventilation is accomplished at airway pressures equivalent to atmospheric or continuous positive airway pressure, with acceleration forces less than +/-1 G(z).

Abdomen↗

Hemodynamic effects of periodic G(z) acceleration in meconium aspiration in pigs.

The hemodynamic effects of periodic acceleration (pG(z)), induced in the spinal axis with noninvasive motion ventilation (NIMV), were studied in a piglet model of pulmonary hypertension associated with meconium aspiration. Animals (n = 12) were anesthetized, paralyzed, intubated, and supported by conventional mechanical ventilation (CMV). Thirty minutes after tracheal instillation of meconium solution (6 ml/kg), either CMV (n = 6) was continued or NIMV (n = 6) was initiated. Changes in systemic and pulmonary hemodynamics and arterial blood gases were tracked for 2 h after aspiration. Thermodilution, cardiac output, and heart rate were not significantly different after meconium aspiration in the pG(z) group relative to the CMV controls. Aortic pressure and systemic vascular resistance were significantly lower (approximately 30%) after meconium aspiration in NIMV animals relative to CMV animals. Pulmonary arterial pressure and pulmonary vascular resistance were also significantly lower, by 100%, after aspiration of meconium in the NIMV animals compared with the CMV controls. Meconium aspiration significantly decreased total respiratory compliance by approximately 50% and increased total respiratory resistance by approximately 100% in both CMV and NIMV animals, but such alterations did not differ between the two groups. Both CMV and NIMV satisfactorily supported ventilation in these paralyzed animals. In conclusion, NIMV through pG(z) in the spinal axis decreased systemic and pulmonary vascular resistance in piglets after meconium aspiration.

Acceleration↗

Inductance cardiography (thoracocardiography): a novel, noninvasive technique for monitoring left ventricular filling.

PURPOSE: Thoracocardiography noninvasively records left ventricular volume curves by an inductive plethysmographic transducer transversely encircling the chest near the xiphoid process. Amplitudes of thoracocardiographic curves track stroke volume as previously validated by thermodilution. We investigated whether thoracocardiographic curves reflect left ventricular filling. MATERIALS AND METHODS: We studied nine men in horizontal and 30 degrees head-up position during tidal breathing and Valsalva maneuvers. The ratio of peak slope of left ventricular volume curves during early rapid filling relative to that during atrial contraction (E/A ratio) and isovolumic relaxation time (interval from aortic component of second heart sound to early rapid filling onset) were measured with thoracocardiography and compared with Doppler-echocardiographic-derived indices of transmitral flow velocity. RESULTS: Isovolumic relaxation times estimated by the two methods agreed closely (bias = -2 ms, limits of agreement = -28 to +24 ms, 75 comparisons). E/A ratios by thoracocardiography and Doppler echocardiography were significantly correlated (R = 0.53, n = 75, P<.001), but individual values differed. Both methods provided identical trends of changes in E/A ratios with interventions in 50 of 66 (76%) comparisons. CONCLUSIONS: Thoracocardiography reflects characteristics of left ventricular filling similar to Doppler echocardiography. Because it does not require hand-holding a transducer, thoracocardiography has the potential for continuous monitoring of mechanical cardiac performance.

Adult↗

Thoracocardiography: noninvasive monitoring of left ventricular stroke volume.

PURPOSE: Thoracocardiography noninvasively monitors global stroke volume by inductive plethysmographic recording of ventricular volume curves as previously validated by thermodilution. Our purpose was to investigate the potential of thoracocardiography to individually assess stroke volume of the left ventricle. We hypothesized that curves predominantly reflecting left ventricular volume could be obtained by recording waveforms from thoracocardiographic transducers placed at various levels around the chest, and by identifying their origin as the left ventricle if mean expiratory exceeded mean inspiratory stroke volumes during spontaneous breathing. MATERIALS AND METHODS: Stroke volumes obtained by thoracocardiography in normal subjects were compared beat by beat with estimates derived from simultaneous measurements of left ventricular cavity stroke area by echocardiography with automatic boundary detection. Changes in respiratory variations of stroke volumes were analyzed during spontaneous breathing at fixed rate and tidal volume, during mechanical ventilation, and resistive loaded breathing. RESULTS: In 170 comparisons of beat-by-beat stroke volumes, 89% of thoracocardiographic fell within +/-20% of echocardiographic estimates. Changes in tidal volume, resistive loaded breathing, and mechanical ventilation induced respiratory variations of thoracocardiographic derived stroke volumes consistent with the known effect of respiratory changes in intrapleural pressure on left ventricular stroke volumes. CONCLUSIONS: The results suggest that thoracocardiography noninvasively tracks changes in left ventricular stroke volumes. Their absolute value may also be monitored if an initial calibration by an independent technique, such as echocardiography, is performed.

Adult↗

Hypoxemic events in spontaneously breathing premature infants: etiologic basis.

Studies of severe hypoxemic events, defined as an arterial oxygen saturation < 80% greater than 4 s in spontaneously breathing infants, have been limited. The purpose of our study was to examine the distribution of respiratory events that lead to a fall in oximetrically measured oxygen saturation by using breathing patterns, heart rate, and validated pulse oximetry analysis. A total of 161 hypoxemic events were detected in 18 of 30 premature infants studied. Using an inductive plethysmographic based monitor, a total of 460 h of cardiorespiratory monitor recordings were analyzed. Hypoxemic events were categorized as being the direct result of apnea (duration longer than 15 s) or pauses (duration 4-14 s) with either unchanged or lower end-expiratory lung volumes compared with the preevent breaths. The breaths in the preevent period were analyzed for volume, timing, and thoracoabdominal coordination indices. Forty of the 161 events (25%) were associated with apnea of which 80% (31/40) had a mixed/obstructive basis. Ninety-four of the 161 severe hypoxemic events (58%) were associated with pauses with unchanged end-expiratory lung volume. Twenty-two of the 161 events (14%) showed pauses with lower end-expiratory lung volume. There were 5/161 events (3%) with severe hypoxemia in which no pause was observed. Comparison of the preevent periods in each category showed significant differences for only percent tidal volume from initial calibration and arterial oxygen saturation. Sixty-two percent (100/161) of severe hypoxemic events were preceded by hypopneic values of percent tidal volume. Seventy-five percent (40/161) of these hypoxemic events and their etiology would have gone undetected using respiratory monitoring from impedance pneumograms and ECGs. The varied basis for these events underscores the importance of analyzing detailed respiratory wave forms along with movement-free signal of arterial oxygen saturation and ECG, to formulate appropriate intervention strategies.

Apnea↗

Breathing pattern during sleep disruptive snoring.

Breathing disturbances during snoring have been quantified by face mask pneumotachography and oesophageal catheters. In order to nonobtrusively investigate respiratory mechanics during nonapnoeic snoring in relation to sleep disturbances, we employed calibrated respiratory inductive plethysmography (RIP). In 10 snorers, RIP recordings were studied during nonapnoeic snoring without arousals in non-rapid eye movement (NREM) sleep, nonapnoeic snoring with repetitive arousals in NREM sleep and wakefulness. Results were compared to RIP recordings in undisturbed NREM sleep and wakefulness in seven healthy nonsnorers. Compared to wakefulness and undisturbed NREM sleep in nonsnorers, snoring was associated with predominant thoracic breathing, ribcage/abdominal asynchrony, and increased fractional inspiratory time. Preceding arousals during snoring, inspiratory flattening of time-derivatives of RIP volume signals, and marked ribcage/abdominal asynchrony indicated pronounced flow limitation. Low variation coefficients of respiratory cycle time (<10%) and tidal volume (<20%) discriminated snoring periods without arousals from snoring periods with arousals and from wakefulness periods, with a sensitivity of 100% and a specificity of 99%. Snoring periods with arousals were identified by the presence of snoring combined with high coefficients of variation of cycle time (> or =10%) and tidal volume (> or =20%), with a sensitivity of 96% and a specificity of 100%. Thus, characteristic patterns of ribcage/abdominal motion recorded by respiratory inductive plethysmography differentiated breathing in sleep disruptive snoring from simple snoring.

Adult↗

A computer algorithm for differentiating valid from distorted pulse oximeter waveforms in neonates.

Current pulse oximeter technology is fraught with a significant false alarm rate. This is mainly due to motion artifacts at the sensor site which distort the pulse waveform and render the computation of SaO2 invalid. If the pulse waveform could be automatically recognized as either normal or distorted, then only valid SaO2 values would be displayed. We observed that the systolic upstroke time (Sy) of the pulse waveform has a narrow and consistent range in normal appearing pulses. The systolic upstroke time (Sy) is the time from the onset of systole to the peak of the pulse waveform. Comparison of a preset range of Sy was made against Sy obtained by computer analysis of each pulse waveform. Visual examination of 14,090 pulses was carried out to determine the sensitivity and false positive rate of the algorithm. Sensitivity of computer detection of valid pulses was 92% with a positive predictive value of 92%. When used on line for continuous recording of SaO2 in patients, this simple algorithm has the potential to decrease the false alarm rate of pulse oximeters and improve the accuracy of long-term SaO2 recordings.

Algorithms↗

Diaphragmatic flutter in three babies with bronchopulmonary dysplasia and respiratory syncytial virus bronchiolitis.

Abnormalities of respiratory control, especially apnea, have been reported previously in infants with respiratory syncytial virus (RSV) infections. This is the first report of yet another abnormality of respiratory control, diaphragmatic flutter (DF), in infants with RSV infection. The presentation of these infants did not differ from the usual clinical presentation of RSV infection. While being monitored with respiratory inductive plethysmography for occurrences of apnea known to be common in RSV infection, DF was detected. This abnormality consisted of high frequency, diaphragmatic contractions which were intermittent in nature. They lasted no more than 4 days and were not associated with change in arterial oxygen saturation or heart rate. These infants were discharged free of DF and no further episodes have been observed over a 12-month period.

Administration, Inhalation↗

Effect of mouthpiece breathing on cardiorespiratory response to intense exercise.

Use of mouthpiece and noseclips after breathing pattern at rest and during moderate exercise. Our purpose was to extend observations on mouthpiece breathing to its effects on the cardiorespiratory response to intense exercise and to develop and validate an algorithm for computer-assisted analysis of breathing pattern recorded with respiratory inductive plethysmography. Six normal men performed incremental bicycle exercise to volitional exhaustion on two occasions with and without mouthpiece and noseclip. ECG and breathing pattern recorded with a respiratory inductive plethysmograph were analyzed manually and with computer assistance. Mouthpiece breathing increased tidal volume and respiratory cycle time by up to 63 and 33% respectively (p < 0.02) during mild exercise, but it did not alter performance, heart rate, or breathing pattern at maximal exercise. Mean differences between inductive plethysmographic and spirometric tidal volumes were < 5% during validation at rest and maximal exercise. Application of the proposed algorithm for semiautomatic breathing pattern analysis provided significant time savings with no loss in precision compared with manual analysis. In conclusion, in normal men, performance and breathing pattern during maximal exercise are not altered by a mouthpiece and noseclip, and accurate computer-assisted measurement of ventilation from external transducers may be performed even during intense exercise.

Adult↗

Comparison of supine and prone noninvasive measurements of breathing patterns in fullterm newborns.

The current study was undertaken to ascertain whether shift from supine to prone posture alters the pattern of natural breathing in healthy fullterm newborns. Breathing patterns were measured in the supine and prone posture in 20 healthy fullterm infants using calibrated, noninvasive respiratory inductive plethysmography (RIP). The values for breathing pattern components in supine and prone postures expressed as means (+/- SD) were, respectively, tidal volume (VT), 14.1(+/- 3.2) and 18.9(+/- 4.9)mL; mean inspiratory flow 26.7(+/- 11.5) and 32.8(+/- 13.0)mL/s; and minute ventilation 232(+/- 75) and 288(+/- 96)mL/kg/min (P < 0.01). Less thoracoabdominal incoordination, expressed as the labored breathing index (LBI), occurred with shift from supine to prone posture in infants studied in the active behavioral stage, changing from 2.0(+/- 0.5) to 1.3(+/- 0.4) (P < 0.01). Placement of a facemask-pneumotachograph system increased VT measured with RIP by 26% in the supine, and 18% in the prone posture. Neither respiratory rate nor inspiratory time (Ti) changed with the postural shift. Therefore, change from supine to prone posture improved ventilation and increased respiratory drive as expressed by VT/Ti. Further, thoracoabdominal incoordination which took place during active sleep in the supine posture, lessened with change to the prone posture.

Humans↗

Thoracocardiographic-derived left ventricular systolic time intervals.

Thoracocardiography noninvasively estimates left ventricular performance by recording ventricular volume curves with inductive plethysmography. We studied timing of these curves to evaluate their potential to accurately track systolic time intervals in comparison with standard methods. Thoracocardiographic left ventricular volume curves, carotid pressure pulses determined by applanation tonometry, the phonocardiogram and ECG were recorded simultaneously in ten normal subjects at various body positions achieved with a tilt table. An equation was derived to predict preejection period from onset of ejection in thoracocardiographic curves. Ventricular ejection time was calculated as total electromechanical systole obtained by phonocardiography minus preejection period. The equation was validated prospectively in 31 measurements in critically ill patients. In normal subjects, the interval ECG Q wave to ejection onset in thoracocardiographic curves correlated well with preejection period from applanation tonometry and phonocardiography (r = 0.92; standard error of estimate (SEE), 8 ms; p < 0.001). Thoracocardiographic curves showed a delay that varied with body position according to the regression equation: delay = 40 ms + 10 x sine (tilt angle) (where r = 0.62; SEE, 7 ms; p < 0.001). Application of this equation in the prospective study in patients revealed close agreement in systolic time intervals from thoracocardiography and simultaneous applanation tonometry plus phonocardiography, respectively. The mean difference +/- SD between methods in preejection periods was 3 +/- 7 ms and in the ratios of preejection period to left ventricular ejection time, 0.02 +/- 0.05. Trends of changes in systolic time intervals were identical for the two methods. We conclude that thoracocardiography combined with phonocardiography provides accurate systolic time intervals when corrected for a position-dependent delay of its waveforms.

Adult↗

Measurement of breath amplitudes: comparison of three noninvasive respiratory monitors to integrated pneumotachograph.

Measurement of breath amplitude (BA) and similarly tidal volume (VT) in newborn infants is the standard for detection of apnea and hypopneas. The purpose of our study was to compare the accuracy for BA by three frequently utilized noninvasive respiratory monitors: respiratory inductive plethysmography (RIP), mercury in silastic strain gauges (SG), and impedance pneumography (IP). Twenty healthy full-term infants were studied in both supine and prone postures. The RC and AB gain factors for RIP were obtained using qualitative diagnostic calibration (QDC) procedure. The electrical gain of IP was set equivalent to the BA signal of a pneumotachograph (PNT). The three devices were calibrated in the supine posture and measurements were repeated in the prone posture without changing their calibration factors. Compared to PNT, postural change did not significantly alter BA measured by RIP. The accuracy of breath-to-breath BA measurement in the prone posture was worse for IP and SG compared to RIP and PNT. In contrast to SG or IP, the accuracy of BA measurement maintained was by RIP after a postural change from supine to prone in fullterm newborns.

Humans↗