M A Samphilipo

Publications and source records attributed to M A Samphilipo.

16 recordsLinked to original sources

Quantitative proton spectroscopy of canine brain: in vivo and in vitro correlations.

Quantitative, single-voxel proton NMR spectroscopy of normal brain was performed in five adult beagle dogs using the cerebral water signal as an internal intensity reference. The same brain regions were then rapidly isolated and frozen using a pneumatic biopsy drill, perchloric acid extracted, and analyzed by biochemical assay and high-resolution NMR spectroscopy. The concentrations of the major resonances in the in vivo and in vitro spectra were compared, and good agreement was found between the different measurements. The in vivo spectra contained three peaks at 3.21, 3.04, and 2.02 ppm, which are usually assigned to trimethylamines (TMA), creatines, and N-acetyl derivatives (NAc), which corresponded to be the following metabolite concentration values: 1.7 +/- 0.6, 7.7 +/- 2.1, and 10.9 +/- 2.7 mumol/g wet weight respectively. In vitro, the following metabolite concentrations were measured: glycerophosphocholine (GPC) 1.3 +/- 0.2, phosphocholine (PC) 0.5 +/- 0.1, phosphocreatine (PCr) 2.6 +/- 0.4, creatine (Cr) 5.9 +/- 1.4, and N-Acetyl aspartate (NAA) 8.9 +/- 1.8 mumol/g wet weight. Therefore, the 3.21 ppm resonance observed in the in vivo spectrum is predominantly GPC and PC in a ratio of 2.6:1, the 3.04 ppm resonance is Cr and PCr in a ratio of 2.3:1, and the 2.02 ppm resonance is predominantly (approximately 80%) NAA with small contributions from N-acetylaspartylglutamate (NAAG) and glutamate. The data presented here validate the technique of water referencing as a simple and convenient means of quantitating single-voxel in vivo proton NMR spectra of the brain.

Animals↗

Multimodality correlative study of canine brain tumors. Proton magnetic resonance spectroscopy, positron emission tomography, and histology.

RATIONALE AND OBJECTIVES: Structural/functional relationships in an induced canine brain tumor were studied using proton-magnetic resonance spectroscopy (1H-MRS), positron emission tomography (PET), and histology. METHODS: Proton-MRS and PET data of implanted canine brain tumors were correlated with quantitative analysis of the tissue composition within the MRS and PET regions of interest (ROIs). Linear regression analysis was employed to correlate the 1H-MRS and PET data with the percent tumor and the percent total lesion (comprising tumor plus associated pathology ie, edema, cysts, hemorrhage, inflammation) within the ROI. RESULTS: Using 1H-MRS, N-acetyl aspartate concentrations were indirectly correlated with the amount of tumor (P = .058), as well as the amount of tumor plus associated pathology (P = .032) within the ROI. Total creatine concentrations were indirectly correlated with the amount of tumor and the amount of tumor plus associated pathology within the ROI (P < .05). Lactate concentrations were directly correlated with the amount of tumor (P = .053) and the amount of tumor plus associated pathology (P = .058) within the ROI. Using PET, Oxygen metabolic rates were indirectly correlated with the amount of tumor and with the amount of tumor plus associated pathology within the ROI (P < .05). Glucose metabolic rates were directly correlated with both the amount of tumor and with the amount of tumor plus associated pathology at P < .05. Proton-MRS measured concentrations of choline and PET measured values for blood flow, and oxygen extraction showed correlations with the amount of tumor and with the amount of tumor plus associated pathology at P > or = .08. CONCLUSIONS: The PET and MRS data were complementary with respect to suggesting anaerobic glucose metabolism for the tumor. Unlike other tumors, no increase in choline was noted in the canine tumor.

Animals↗

Palmaz stent in the treatment of central venous stenosis: safety and efficacy of redilation.

PURPOSE: To assess the safety and efficacy of redilation of central venous stents in a growing animal model. MATERIALS AND METHODS: Palmaz stents were placed in the inferior vena cava (IVC) in 18 newborn lambs. After 5 months, vena cavography was performed. Those animals in which growth of the IVC adjacent to the stent and/or neointimal hyperplasia had resulted in a stenosis were considered candidates for redilation. Repeat vena cavography, intravascular ultrasound, and histologic examination were performed at 2 or 6 months. RESULTS: A stenosis of > 20% was demonstrated in 13 animals. Redilation was performed, and a 50% mean increase in stent diameter was achieved. There were no immediate complications. Late complications included nonocclusive laminar clot (n = 2), and a bar of tissue dividing but not occluding the caval lumen (n = 1). Moderate neointimal hyperplasia occurred in all stents. Stent compression (unrelated to redilation) occurred in seven animals. CONCLUSION: Palmaz stents can be redilated safely and effectively in an animal model of growing central veins.

Animals↗

Hydrogel embolic agents. Theory and practice of adding radio-opacity.

RATIONALE AND OBJECTIVES: Spheres of hydrogel have been developed as embolic material with the ability to incorporate radio-opaque materials. To optimize particle design for radiographic or fluoroscopic visualization, we have examined the theoretical determinants of particle contrast. In addition, loaded hydrogel particles were tested in a rabbit model. METHODS: Computer simulations of particle subject contrast were examined regarding particle composition, particle size, patient thickness, and x-ray beam kilovoltage. Embolizations in the rabbit kidney were used to test the practical aspects of the materials. RESULTS: Tantalum and tungsten offer some theoretical and practical advantages over other materials. With this particular hydrogel preparation, contrast material loading was limited to 20% of the volume as loaded contrast agent. The soft particles passed through catheters as small as 3 French; they were usually injected as a suspension of saline/contrast material. Tantalum/hydrogel particles as large as 2 mm could be forced through the 140 cm/3-Fr catheter with a guide wire. CONCLUSIONS: Radio-opacity of embolic material should add an element of control in embolization procedures that is lacking with the current agents. The heavy metals, tungsten and tantalum, are suitable additives for radiopaque material for hydrogel emboli. The input relationship appears predictable with computer monitoring techniques. Initial results in a study of these radiopaque particles are very encouraging. Further studies are underway to evaluate the long-term effects in renal and hepatic circulations.

Acrylic Resins↗

Quantitative proton spectroscopy and histology of a canine brain tumor model.

Quantitative, single voxel proton nuclear magnetic resonance (NMR) spectroscopy and histological analysis was performed in eight dogs implanted with the transplantable canine glioma model of Wodinsky (Proc. Am. Assoc. Cancer Res. 10, 99 (1969)). Signals from choline, creatine, N-Acetyl Aspartate (NAA) and lactate were converted to molar concentration units and correlated with the quantitative analysis of histologically determined tissue types within the localized volume selected for NMR spectroscopy. In general, compared with normal brain, the lesions were associated with reductions in all metabolite concentrations, with the exception of lactate, which was increased. NAA and creatine decreases were most significantly correlated with the total lesion volume (P < 0.01), suggesting that these compounds are present in normal brain only. Changes in choline levels did not correlate strongly with any particular tissue type. Lactate was found to increase with increasing total lesion volume (P < 0.01), but not with increasing percent tumor, suggesting that it accumulates in abnormal tissue other than the tumor. The spectra reported were similar to those observed in human glioblastomas, with the exception that elevations of choline were not observed. The transplantable canine gliosarcoma system appears to be a suitable tumor model for evaluation by clinical radiological techniques such as magnetic resonance imaging (MRI) and proton NMR spectroscopy.

Animals↗

In vivo and in vitro 31P-NMR preliminary studies of the VX-2 carcinoma in rabbits.

In vivo and in vitro 31P-NMR spectroscopy was used to study the high energy phosphate metabolism of VX-2 tumors implanted into rabbit liver, kidney, and hind-limb muscle. Tumors, at various stages of growth, were first examined by in vivo 31P-NMR spectroscopy, then they were excised and underwent histologic examination and biochemical analysis; both in vitro 31P-NMR and standard enzymatic techniques were used. There was good correlation among the in vivo NMR spectra, the in vitro NMR data, and the biochemical analyses. Although the tumor spectra showed characteristics similar to those reported in the other tumor models, there was a striking variability in the spectra obtained from tumors implanted in the same site and from different sites. There was poor correlation between the degree of necrosis in the tumor and the tumor pH and between the Pi:ATP ratio and necrosis. This variability has important implications for the potential value of using 31P-NMR spectroscopy to monitor tumor growth and therapy in vivo.

Adenosine Triphosphate↗

A reservoir model for repeated CSF access in the rabbit.

A simple, reliable and inexpensive subcutaneously implanted reservoir-catheter system method was developed for repeated sterile access to the rabbit brain ventricular system. The system provides an avenue for the repeated intrathecal administration of drugs and for the withdrawal of cerebrospinal fluid (CSF). Reservoirs were subcutaneously implanted under the scalp and connected to tubing inserted into the cisterna magna or the lateral ventricle. The systems successfully functioned in 38 of 41 animals (12 with cisternal magna catheters and 29 with lateral ventricle catheters), for up to 12 weeks following implantation. Patency of the systems were documented with X-rays and radiopaque injected contrast medium.

Animals↗

Evaluation of venous injury caused by a percutaneous mechanical thrombolytic device.

PURPOSE: To study venous injury caused by a prototype percutaneous mechanical thrombolytic device. METHODS: Simulated thrombolysis was performed using the device, or the Fogarty balloon catheter (FBC) as control, in the infrarenal inferior vena cava (IVC) of 40 New Zealand white rabbits. Venous injury was evaluated by cavography, Evans blue dye staining, and histology at 0, 1, and 6 weeks postprocedure. RESULTS: Both devices resulted in near complete endothelial denudation acutely. No differences in reendothelialization were noted at any time in the proximal and mid-IVC, but there was significantly greater reendothelialization in the distal IVC in the rabbits treated 6 weeks earlier with the device (p < or = 0.04). Additionally, the inner luminal diameter at necropsy for the 1-week rabbits treated with the FBC was significantly narrower in the distal and middle sections of the IVC when compared with the device (p < or = 0.02 for both segments). There was no luminal diameter difference at 0 or 6 weeks. CONCLUSION: Based on a rabbit model, venous injury from the device was found to be similar to, and in the distal IVC less than, the routinely used FBC.

Animals↗

Subcutaneously tethered temporary filter: pathologic effects in swine.

PURPOSE: To evaluate the histopathologic effects of the Tempo-filter, a temporary caval filter, on the caval wall and determine the feasibility of deployment and removal of the device in swine. MATERIALS AND METHODS: Filters were placed in the infrarenal inferior vena cava of 11 swine. The tethering catheter was sutured in a subcutaneous pocket near the puncture site. The original tethering catheter used in humans and a stiffer catheter designed to prevent migration in swine were evaluated. Postplacement, mid-study, and preexplant vena cavography procedures were performed. Four swine underwent in situ dissection at 3-10 weeks. Filters were removed from seven animals just before they were killed at 1-6 weeks. RESULTS: All filters were successfully placed. All seven filters were successfully removed at up to 6 weeks after placement. Cephalic migration of more than 1 cm was observed in 10 of 11 swine (100% of original catheters, 83% of stiff catheters). Other complications were more common with stiffer tethering catheters, including caval stenosis in 40% of original catheters and 100% of stiff catheters, filter cone thrombus in 0% and 67%, tethering catheter thrombus in 20% and 83%, pulmonary embolism in 0% and 50%, and death in 0% and 17%, respectively. There was mild vessel wall damage in the vena cava. CONCLUSION: Placement of the Tempofilter and removal at up to 6 weeks after placement is feasible.

Animals↗

Comparison of Gianturco Z stents and Wallstents in a hemodialysis access graft animal model.

PURPOSE: To compare the primary patency of two structurally different metallic stents in an animal model of hemodialysis access grafts. MATERIAL AND METHODS: Nineteen synthetic femorofemoral arteriovenous shunts were created in 10 dogs. After a 1-month period of maturation (during which one graft thrombosed), stents were placed spanning the venous anastomosis. The grafts were divided into two treatment groups (Wallstent, n = 6, and Gianturco stent, n = 6) and a control group with no stent (n = 6). Fistulograms and pressure measurements were obtained at monthly intervals for 6 months or until thrombosis of the graft. RESULTS: Mean graft patency in the Wallstent group (112 days +/- 30) was significantly shorter than in the control (157 days +/- 32, P < .03) or Gianturco (157 days +/- 32, P < .05) groups. Patency in the Gianturco stent group was no different from that in the control group. Stenosis due to intimal hyperplasia within the stents appeared greater in the Wallstent group but did not achieve statistical significance. One Wallstent migration, three Gianturco stents shifts, and two Gianturco stent breakages occurred. Histologic examination revealed a necrotizing vasculitis in the portion of vein containing the stent in all grafts treated with the Gianturco stent but not in any other grafts. CONCLUSION: In an animal model of hemodialysis access grafts, the Gianturco stent had longer primary patency than the Wallstent when placed across the venous anastomosis. However, stent fractures and focal necrotizing inflammation may limit the use of the Gianturco stent in hemodialysis access.

Anastomosis, Surgical↗

Histopathologic appearance of arterial occlusions with hydrogel and polyvinyl alcohol embolic material in domestic swine.

PURPOSE: This study observes the histologic changes resulting from a hydrogel embolic agent (polyacrylonitrile [PAN]) compared with polyvinyl alcohol particles (PVA) of similar size. MATERIALS AND METHODS: Hepatic and renal embolizations were performed in 13 domestic swine by selecting small (1-mm) branches utilizing a coaxial 3-F microcatheter. The hydrogel embolic agent (tantalum-loaded and plain) and PVA were delivered through microcatheters. The longest follow-up period was 8 weeks. Postmortem examination of the embolized tissues included gross examination and histologic analysis. RESULTS: Tantalum-loaded PAN particles were radiopaque and seen in groups fluoroscopically and individually with specimen radiography. Histologic studies showed similar luminal and cellular response to PVA and the hydrogel embolic agents. The arterial lesion induced by the hydrogel embolic agents led to an absence of the arterial wall locally in the area of deployment. Hydrogel embolic particles became surrounded in fibrous connective tissue with no arterial wall. PVA and porous hydrogel capsules produced an inflammatory response, resulting in less wall reorganization, and surrounding fibrous connective tissue at 8 weeks than the solid PAN particles. CONCLUSION: These hydrogel embolic create a permanent arterial occlusion by transmural arterial damage. Mechanical effects and, to a lesser degree, inflammatory changes are responsible.

Acrylic Resins↗

A reproducible canine model of nonocclusive mesenteric ischemia.

A technique for producing a reliable, clinically applicable, and highly reproducible canine model of nonocclusive mesenteric ischemia was developed. Following left thoracotomy in 10 dogs, a 1 mm diameter soft polyethylene tube was inserted into the pericardial space via a small puncture site. This tube was sealed in place with cyanoacrylate tissue adhesive. A solution of 10% Dextran 40 in saline was infused into the pericardial space until a 50% reduction (as monitored by electromagnetic flowmeter) in superior mesenteric artery flow (SMAQ) was obtained. Without additional intrapericardial infusion of the Dextran solution, SMAQ was reduced 51 +/- 4% to 54 +/- 3% of control values during a 60 minute post-tamponade observation period. During the same time. Cardiac output was depressed between 40 +/- 8% and 54 +/- 3%, and right atrial pressure remained elevated between 164 +/- 15% and 171 +/- 15%. Systemic arterial pressure initially dropped 28 +/- 5% but compensated to within 11 +/- 5% of pre-tamponade level at 60 minutes. The stability of this model is well suited for evaluating new experimental diagnostic and therapeutic procedures.

Animals↗

Organ ablation by fluid emboli. An experimental study comparing two solidifying liquids.

Embolization for ablation of organs and tumor infarction requires uniform permanent occlusion of the distal vasculature. This is best accomplished through the use of solidifying liquids. The study on 15 dogs reported here compares the degree of peripheral vascular embolization and its relation to tissue infarction both acutely and chronically following embolization of the renal arteries with two solidifying liquids, a low viscosity silicone and the occlusion gel Ethibloc. Silicone produced quite uniform distal distribution including 50 to 80% (mean 66%) of renal glomeruli, whereas Ethibloc occluded more proximally and reached only 10 to 50% (mean 22%) of all glomeruli. After three months complete cortical infarction of all nine kidneys embolized with silicone was found, whereas two of the three kidneys embolized with Ethibloc retained nests of viable glomeruli. Balloon occlusion of the entire renal artery inflow during embolization prevented distal venous emboli whereas partial inflow occlusion allowed systemic venous embolization. It is concluded that due to its more uniform distal penetration low viscosity silicone is a more suitable embolization agent than Ethibloc for organ ablation. Total arterial inflow occlusion during embolization effectively prevents systemic venous embolization.

Animals↗