PubMed Health⌕ Search

Biomedical subjects

M A Wall

Publications and source records attributed to M A Wall.

59 records · Page 4Linked to original sources

A Gaussian method to improve work-of-breathing calculations.

The work of breathing is a calculated index of pulmonary function in ventilated patients that may be useful in deciding when to wean and when to extubate. However, the accuracy of the calculated work of breathing of the patient (WOBp) can suffer from artifacts introduced by coughing, swallowing, and other non-breathing maneuvers. The WOBp in this case will include not only the usual work of inspiration, but also the work of performing these non-breathing maneuvers. The authors developed a method to objectively eliminate the calculated work of these movements from the work of breathing, based on fitting to a Gaussian curve the variable P, which is obtained from the difference between the esophageal pressure change and the airway pressure change during each breath. In spontaneously breathing adults the normal breaths fit the Gaussian curve, while breaths that contain non-breathing maneuvers do not. In this Gaussian breath-elimination method (GM), breaths that are two standard deviations from that mean obtained by the fit are eliminated. For normally breathing control adult subjects, GM had little effect on WOBp, reducing it from 0.49 to 0.47 J/L (n = 8), while there was a 40% reduction in the coefficient of variation. Non-breathing maneuvers were simulated by coughing, which increased WOBp to 0.88 (n = 6); with the GM correction, WOBp was 0.50 J/L, a value not significantly different from that of normal breathing. Occlusion also increased WOBp to 0.60 J/L, but GM-corrected WOBp was 0.51 J/L, a normal value. As predicted, doubling the respiratory rate did not change the WOBp before or after the GM correction.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Variability, reproducibility, and data-collection time of pulmonary bedside monitoring.

Breath-by-breath pulmonary function testing at the bedside is now available both with special-purpose stand-alone equipment and with the new generation of ventilators. The authors studied the variability of, reproducibility of, and ideal length of data collection for nine indices of pulmonary function that may be useful for ventilatory management, weaning, and patient comfort. Work of breathing (as both J/L and J/min), pressure-time product, rapid shallow breathing index, respiratory time fraction, respiratory drive, change in esophageal pressure during inspiration, expiratory airway resistance, and dynamic compliance were measured in ten normal subjects and in eight patients being weaned from mechanical ventilation. All nine indices were reproducible when compared by paired t-test with two separate sets of data collected in normal subjects. Repeated measures in the normal subjects allowed calculation of 95% confidence intervals for the nine variables. There was no statistically significant difference between data collections of 5 minutes compared with those of 10 and 15 minutes. Breath-by-breath variability ranged from a coefficient of variation of 3% for the shallow breathing index in one patient to 131% for the work of breathing in J/min in another. Population variability ranged from values reported previously for other pulmonary parameters to nearly double for some parameters. The authors conclude that a 5-minute data collection time is sufficient to obtain reliable breath-by-breath data at the bedside. While taken together these indices may provide clinically useful information, their usefulness individually remains to be demonstrated because of their large variability.

Adult↗