Bone mineral density in the proximal tibia varies as a function of static alignment and knee adduction angular momentum in individuals with medial knee osteoarthritis.

Based on the premise that bone mass and bone geometry are related to load history and that subchondral bone may play a role in osteoarthritis (OA), we sought to determine if static and dynamic markers of knee joint loads explain variance in the medial-to-lateral ratio of proximal tibial bone mineral density (BMD) in subjects with mild and moderate medial knee OA. We utilized two surrogate markers of dynamic load, the peak knee adduction moment and the knee adduction angular momentum, the latter being the time integral of the frontal plane knee joint moment. BMD for medial and lateral regions of the proximal tibial plateau and one distal region in the tibial shaft was measured in 84 symptomatic subjects with Kellgren and Lawrence radiographic OA grades of 2 or 3. Utilizing gait analysis, the peak knee adduction moment (the external adduction moment of greatest magnitude) and the time integral of the frontal plane knee joint moment (the angular momentum) over the entire stance phase as well as for each of the four subdivisions of stance were calculated. The BMD ratio was not significantly different in grade 2 (1.32 +/- 0.27) and grade 3 knees (1.47 +/- 0.40) (P = 0.215). BMD of the tibial shaft was not correlated with any loading parameter or static alignment. Of all the surrogate gait markers of dynamic load, the knee adduction angular momentum in terminal stance explained the most variance (20%) in the medial-to-lateral BMD ratio (adjusted r(2) = 0.196, P < 0.001). The knee adduction angular momentum for the entire stance phase explained 18% of the variance in the BMD ratio (adjusted r(2) = 0.178, P < 0.001), 10% more variance than explained by the overall peak knee adduction moment (adjusted r(2) = 0.081, P < 0.001). 18% of the variance in the BMD ratio was also explained by the knee alignment angle (adjusted r(2) = 0.183, P < 0.001), and the total explanatory power was increased to 22% when the knee adduction angular momentum in terminal stance was added (change in r(2) = 0.041, P < 0.05, total adjusted r(2) = 0.215, P < 0.001). The BMD ratio and its relationship to dynamic and static markers of loading were independent of height, weight, and the body mass index, demonstrating that both dynamic markers of knee loading as well as knee alignment explained variance in the tibial BMD ratio independent of body size.

Absorptiometry, Photon↗

Investigation on stick phenomena in metal-on-metal hip joints after resting periods.

Insufficient understanding of tribological behaviour in total joint arthroplasty is considered as one of the reasons for prosthesis failure. Contrary to the continuous motion input profiles of hip simulators, human locomotion contains motion interruptions. These occurring resting periods can cause stick phenomena in metal-on-metal hip joints. The aim of the present study was to investigate the tribological sensitivity of all-metal bearings to motion interruptions on in vitro test specimens and retrieved implants. Friction and wear with and without resting periods were quantified. Unlike the metal-on-polyethylene joints, the static friction of metal-on-metal joints increased up to micros = 0.3 with rest, while wear appeared to be unaffected. This effect is caused by the interlocking of firmly adhered carbon layers, which were generated from the protein-containing lubricant through tribochemical reactions. Since more than 80 per cent of the retrieved implants exhibited macroscopically visible carbon layers, the increase in friction presumably also occurs under physiological conditions, which is then transferred to the bone-implant interface. These recurrent tangential stress peaks should be considered for the design features of the cup-bone interface, in particular when larger-sized implant heads are used.

Biocompatible Materials↗

Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation.

To control and minimize wear of metal-on-metal hip joints it is essential to understand the mechanisms of debris generation. In vivo, mainly nanosize globular and needle-shaped particles are found. These can neither stem from the action of abrasion nor from tribochemical reactions. In this study the acting wear mechanisms have been first identified on the surface by means of scanning electron microscopy (SEM). Afterwards, the microstructures of the subsurface regions of explants have been investigated using a transmission electron microscope (TEM). Observation of the subsurface gave additional insight about the microstructural changes of cobalt-base alloys subjected to wear. At some distance from the surface, a network of stacking faults and hexagonal epsilon-martensite was found strengthening the bulk material. This microstructure changed into a nanocrystalline type moving closer towards the surface. A comparison of in vivo debris size and grain size of the surface suggests that the globular wear particles result from torn off nanocrystals, while the needle shaped particles are generated by fractured epsilon-martensite. Identified cracks, propagating through the nanocrystalline layer, further support these findings. Thus, it is suggested that the dominating mechanism of particle generation for metal-on-metal joints is surface fatigue within a nanocrystalline surface layer.

Adolescent↗

[Comparison of total hip replacements cup orientation and position. Navigation vs. conventional manual implantation of hip prostheses].

BACKGROUND: Aim of this in-vitro study was to compare the hip cup placement for total hip replacement when using different navigation systems compared with the traditional, non-navigated technique. METHODS: Five different navigation systems were used: the CT-less systems Navitrack, Orthopilot and Surgetics Station, as well as the CT-based Navitrack and VectorVision. Three different surgeons carried out five cup implantations using all navigation systems and the manual approach on a surgery dummy. Cup orientation (inclination and anteversion) and the cup position (achieved cup center) were determined with a coordinate measuring machine. RESULTS: In the manual group the variability of the cup orientation was higher in comparison and hardly influenced by the surgeon. Navigation was identified as a significant factor for smaller deviations from planned inclination and anteversion angles (p<0,001 for both). Cup position was not affected by surgeon in the manual group (p=0,966). Compared with manual technique, the cup misplacement vector was significantly smaller in the CT-Navitrack group (p<0,001) but higher in the Navitrack (CT-less) and VectorVision group (p<0,001). CONCLUSIONS: The use of computer navigation will help the surgeon to orientate the acetabular component more accurately but not necessarily with regard to cup positioning.

Acetabulum↗

Fluid composition impacts standardized testing protocols in ultrahigh molecular weight polyethylene knee wear testing.

Wear of total knee replacements is determined gravimetrically in simulator studies. A mix of bovine serum, distilled water, and additives is intended to replicate the lubrication conditions in vivo. Weight gain due to fluid absorption during testing is corrected using a load soak station. In this study, three sets of ultrahigh molecular weight polyethylene tibial plateau were tested against highly polished titanium condyles. Test 1 was performed in two different institutions on the same simulator according to the standard ISO 14243-1, using two testing lubricants. Test 2 and test 3 repeated both previous test sections. The wear and load soak rates changed significantly with the lubricant. The wear rate decreased from 16.9 to 7.9 mg weight loss per million cycles when switching from fluid A to fluid B. The weight gain of the load soak specimen submersed in fluid A was 6.1 mg after 5 x 10(6) cycles, compared with 31.6 mg for the implant in fluid B after the same time period. Both lubricants were mixed in accordance with ISO 14243 (Implants for surgery - wear of total knee-joint prostheses), suggesting that calf serum should be diluted to 25 +/- 2 per cent with deionized water and a protein mass concentration of not less than 17 g/l. The main differences were the type and amount of additives that chemically stabilize the lubricant throughout the test. The results suggest that wear rates can only be compared if exactly the same testing conditions are applied. An agreement on detailed lubricant specifications is desirable.

Body Fluids↗

Microvascular response of striated muscle to metal debris. A comparative in vivo study with titanium and stainless steel.

Wear products of metal implants are known to induce biological events which may have profound consequences for the microcirculation of skeletal muscle. Using the skinfold chamber model and intravital microscopy we assessed microcirculatory parameters in skeletal muscle after confrontation with titanium and stainless-steel wear debris, comparing the results with those of bulk materials. Implantation of stainless-steel bulk and debris led to a distinct activation of leukocytes combined with a disruption of the microvascular endothelial integrity and massive leukocyte extravasation. While animals with bulk stainless steel showed a tendency to recuperation, stainless-steel wear debris induced such severe inflammation and massive oedema that the microcirculation broke down within 24 hours after implantation. Titanium bulk caused only a transient increase in leukocyte-endothelial cell interaction within the first 120 minutes and no significant change in macromolecular leakage, leukocyte extravasation or venular diameter. Titanium wear debris produced a markedly lower inflammatory reaction than stainless-steel bulk, indicating that a general benefit of bulk versus debris could not be claimed. Depending on its constituents, wear debris is capable of eliciting acute inflammation which may result in endothelial damage and subsequent failure of microperfusion. Our results indicate that not only the bulk properties of orthopaedic implants but also the microcirculatory implications of inevitable wear debris play a pivotal role in determining the biocompatibility of an implant.

Animals↗

Topical corticosteroid therapy for acute radiation dermatitis: a prospective, randomized, double-blind study.

BACKGROUND: Radiation dermatitis is a common side-effect of radiation therapy, but there is no current consensus about its appropriate therapy. OBJECTIVES: To compare treatment with topical 0.1% methylprednisolone vs. 0.5% dexpanthenol in a cohort of patients undergoing fractionated radiation therapy for breast cancer. METHODS: In a randomized, double-blind design, treatment was initiated at the beginning of radiation therapy and continued for 2 weeks after termination of radiation. Outcomes were compared by three different measures: clinical (symptom score), functional (transepidermal water loss, TEWL) and subjective (quality of life, QOL). RESULTS: In a preliminary cohort of untreated patients undergoing radiation therapy, clinical signs and TEWL levels increased progressively during radiation therapy, reaching highest values at 5 and 4 weeks, respectively. Although neither topical treatment reduced the incidence of radiation dermatitis, both delayed the emergence of greatest clinical and TEWL scores until approximately 6 and 5 weeks, respectively. With topical corticosteroids, clinical symptoms and TEWL were less pronounced than with dexpanthenol. Whereas general QOL improved after completion of radiation therapy, skin-related QOL declined. However, the skin-related QOL decline could be at least in part reversed by use of topical corticosteroid vs. dexpanthenol-containing emollient. CONCLUSIONS: We provide evidence that prophylactic and ongoing use of topical therapy with either topical corticosteroid or a dexpanthenol-containing emollient ameliorates, but does not prevent radiation dermatitis. Our data suggest, but do not prove, a benefit of a topical corticosteroid vs. a dexpanthenol-containing emollient. Further controlled studies with larger cohorts will be needed to determine optimal forms of topical therapy for radiation dermatitis.

Acute Disease↗

Impact of a nickel-reduced stainless steel implant on striated muscle microcirculation: a comparative in vivo study.

The impairment of skeletal muscle microcirculation by a biomaterial may have profound consequences. With moderately good physical and corrosion characteristics, implant-quality stainless steel is particularly popular in orthopedic surgery. However, due to the presence of a considerable amount of nickel in the alloy, concern has been voiced in respect to local tissue responses. More recently a stainless steel alloy with a significant reduction of nickel has become commercially available. We, therefore, studied in vivo nutritive perfusion and leukocytic response of striated muscle to this nickel-reduced alloy, and compared these results with those of the materials conventional stainless steel and titanium. Using the hamster dorsal skinfold chamber preparation and intravital microscopy, we could demonstrate that reduction of the nickel quantity in a stainless steel implant has a positive effect on local microvascular parameters. Although the implantation of a conventional stainless steel sample led to a distinct and persistent activation of leukocytes combined with disruption of the microvascular endothelial integrity, marked leukocyte extravasation, and considerable venular dilation, animals with a nickel-reduced stainless steel implant showed only a moderate increase of these parameters, with a clear tendency of recuperation. Titanium implants merely caused a transient increase of leukocyte-endothelial cell interaction within the first 120 min, and no significant change in macromolecular leakage, leukocyte extravasation, or venular diameter. Pending biomechanical and corrosion testing, nickel-reduced stainless steel may be a viable alternative to conventional implant-quality stainless steel for biomedical applications. Concerning tolerance by the local vascular system, titanium currently remains unsurpassed.

Animals↗

Hip simulator wear testing according to the newly introduced standard ISO 14242.

Ultra-high molecular weight polyethylene (UHMWPE) acetabular cups were tested against alumina-ceramic femoral heads using a new type of hip joint simulator according to ISO/FDIS 14242-1. Bovine serum as well as newborn calf serum were used as test fluids. Total polyethylene wear was determined by weight loss of the cups. In addition. wear depth and its distribution were recorded by means of a coordinate measurement system. Wear particle analysis and inspection of the worn polyethylene surfaces using light and scanning electron microscopy (SEM) were performed to analyse damage and identify the acting wear mechanisms. The total wear rate was determined to be 22.07 +/- 1.75 mg/10(6) cycles for the bovine serum group and 26.57 + 3.55 mg/10(6) cycles for the calf serum group. Unexpectedly, the formation of two wear vectors corresponding to recent clinical findings was detected. Retrieved polyethylene wear debris was comparable in size and shape with clinical findings. The test method described by ISO/FDIS 14242-1 produced reliable and reproducible wear data using UHMWPE acetabular cups articulating against alumina-ceramic heads. In the authors' opinion, the lubricant composition should be described in more detail, since the protein and additive content seem to have a high impact on the wear results. It needs to be emphasized that the findings of this study cannot be regarded as a general validation of hip wear tests according to ISO/FDIS 14242-1 but are limited to the material combinations investigated herein. Further testing of other clinically relevant materials and interlaboratory ring tests must follow.

Aluminum Oxide↗

Permeability barrier function of skin exposed to ionizing radiation.

OBJECTIVE: To characterize the epidermal permeability barrier function of skin during exposure to ionizing radiation. DESIGN: A prospective cohort study. SETTING: University hospital medical center. PATIENTS: Fifteen women receiving local radiation therapy (5000-6000 rad [50-60 Gy]) following breast-conserving surgery for breast cancer. MAIN OUTCOME MEASURES: Clinical symptoms and transepidermal water loss (TEWL). RESULTS: Epidermal permeability barrier function is impaired in patients who exhibit clinical signs of radiation dermatitis. The functional damage to the stratum corneum induced by ionizing radiation occurs with a delayed course, starting within a mean period of 11 days and reaching maximal values after a mean period of 27 days (range, 13-75 days). The onset of TEWL increase precedes the onset of radiation dermatitis and the maximal TEWL measurements precede the peak of skin changes. Patients with an early onset of TEWL increase show a longer duration of skin symptoms. CONCLUSIONS: Skin changes caused by radiation dermatitis are associated with an increase in TEWL. The barrier impairment is comparable to the changes observed with UV radiation exposure but exhibits an even more delayed course. Our results suggest that preservation of the epidermal permeability barrier function by topical treatment may ameliorate radiation dermatitis.

Adult↗

Use of ultrasonic nebulizer with desolvator membrane for the determination of titanium and zirconium in human serum by means of inductively coupled plasma--mass spectroscopy.

A technique for the determination of titanium and zirconium in human blood serum, after pressurized digestion utilizing ICP-MS coupled to an ultrasonic nebulizer (USN) and desolvating membrane is described. As no CRM for titanium is available, zirconium has been determined in order to demonstrate the accuracy of the technique, as the limits in blood are well known. Bone cement consists basically of a polymer, namely polymethylmethacrylate (PMMA). For better X-ray contrast some manufacturers use incorporated ZrO2 with a volume fraction of 10 to 15%. Thus, the zirconium present in the PMMA matrix can be used as an indicator for the PMMA particulate debris.

Bone Cements↗

A striated pattern of wear in ultrahigh-molecular-weight polyethylene components of Miller-Galante total knee arthroplasty.

Wear of the polyethylene tibial components is a potential cause of failure in total knee arthroplasty. In addition to pitting, burnishing, and scratching, subtle striations on the bearing portion of the tibial surface have been observed in components retrieved relatively early after implantation. The striated pattern most typically occurred in areas centrally located within the articulating surface. The striations were anteroposterior directed and were identified as local cold flow at the surface. There was a strong correlation between the medial and lateral striated areas, suggesting that these patterns are related to cyclic rolling of the knee. The general characteristics and alignment of the striations could be attributed to the compressive and tractive forces occurring during femoral rollback. For the clinician, these results suggest that kinematics, as well as contact stress, should be considered when evaluating wear of polyethylene components.

Adult↗

[Effect of surface hardness of the femur head prosthesis on abrasive wear forces in pairing with polyethylene for artificial hip joints].

The problem of wear has become a major issue in total joint replacement. A correlation between biomaterial hardness and abrasive wear mechanisms may be assumed. To investigate the effect of hardness, cobalt-chromium (CoCr) femoral heads coated with hard amorphous-hydrogenated carbon (a-CH) were tested against uncoated heads under conditions of abrasive wear. The heads were paired with polyethylene (UHMWPE) discs in a ball-on-disc machine. The abrasive wear resistance of the heads increased with surface hardness, and qualitatively differing patterns of wear were observed on the UHMWPE surfaces, depending on the abrasive wear of the matching areas of the heads. Accordingly, when evaluating biomaterials for their suitability for use in total joint replacement, hardness should be considered one of the relevant factors among the material properties with an influence on wear.

Chromium Alloys↗

Tractive forces during rolling motion of the knee: implications for wear in total knee replacement.

Wear at the polyethylene tibial plateau in total knee arthroplasty (TKR) is one of the primary concerns with these devices. The artificial bearing of a TKR has to sustain large forces while allowing the mobility for normal motion, typically, rolling, gliding and rotation. The tractive forces during the rolling motion at the knee joint were analyzed to determine which factors cause these forces to increase in TKR. The implications of these tractive forces to polyethylene wear were considered. Traction forces were calculated using a model of the knee to evaluate the effect of variations in the coefficient of friction, gait characteristics, antagonistic muscle contraction and patellofemoral mechanics. The model was limited to the sagittal plane motion of the femur on the tibia. The input for the model was the shape of the articulating surface, coefficient of friction, contact path, muscle anatomy and gait kinetics common to patients with a total knee replacement. The generation of tractive forces on the tibial polyethylene plateau was highly dependent on the static and dynamic coefficient of friction between the femur and the tibia. A peak tractive force of approximately 0.4 body weight was calculated with a peak normal force of 3.3 body weight. Tractive rolling occurred during most of stance phase when the static coefficient was 0.2. Alterations in gait patterns had a substantial effect on the generation of tractive forces at the knee joint. When an abnormal gait pattern (often seen following TKR) was input to the model the posteriorly directed tractive force on the tibial surface was reduced. It was also found that variations in muscle contractions associated with antagonistic muscle activity as well as the angle of pull of the patellar tendon affected the magnitude of tractive forces. The results of the study suggest that there are feasible conditions following total knee replacement which can lead to tractive forces during rolling motion at the tibiofemoral articulation that should be considered in the analysis of factors leading to polyethylene damage in total knee replacement.

Feasibility Studies↗

Implications of orthopedic fretting corrosion particles on skeletal muscle microcirculation.

Particulate corrosion and wear products of metal implants are increasingly becoming topics of interest, due to the cascade of biological and biomechanical events they induce. The impairment of skeletal muscle microcirculation by fretting corrosion particles may have profound consequences. We therefore studied in vivo leukocyte-endothelial cell interaction in skeletal muscle after confrontation with characterized titanium and stainless steel fretting corrosion particles, and compared these results with those of the bulk materials. Using the hamster dorsal skinfold chamber preparation and intravital microscopy, we could demonstrate that stainless steel induces a more pronounced inflammatory answer in contrast to the implant material titanium. However, we were not able to show a general benefit of bulk vs. debris. Overall, the study suggests that not only the bulk properties of orthopaedic implants, but also the microcirculatory implications of inevitable wear debris, may play a role in determining biocompatibility and ultimately longevity of an implant. The skinfold chamber is a feasible and versatile model for observation of the dynamic process of microvascular response after foreign-body implantation, and offers much perspective.

Journal Article↗

[Systemic spread of wear debris--an in-vivo study].

AIM: The aim of this study was to elucidate whether there is a systemic spread of wear debris from peripherally applied stainless steel and titanium particles into the blood and subsequently to parenchymatous organs. Furthermore, we report on histological findings at the implantation site. METHOD: In Syrian Gold hamsters we implanted 2 mm3 wear debris of stainless steel and titanium into the dorsal skin fold chamber. Over a period of 2 weeks we took blood samples and afterwards explanted the implant area, the heart, lung, liver and spleen. One half of the organs and the implant area were used for histological analysis. The other half of the organs and the blood samples were analysed by optical emission spectrometer with inductively coupled plasma and graphite furnace atomic absorption spectrophotometry for their contents of chromium, nickel and titanium. RESULTS: In the group with titanium particles, histological analysis of the implant site showed moderate phagocyted wear in granulocytes but no other pathological findings. Animals treated with stainless steel wear debris had a massive inflammatory reaction, in some cases leading to necrosis. The analysis of the blood and one half of the organs showed increased levels of chromium and, already 24 hours after implantation, raised values for nickel. The result of the hamsters treated with titanium showed significantly elevated levels of titanium ions in the organs, but not in the blood samples. Histology of the organs did not reveal pathological findings. CONCLUSION: In this study we could show a massive inflammatory reaction for stainless steel wear debris in contrast to titanium wear debris at the implantation site. The elevated blood levels of chromium and increased values of other metals in the organs suggest the haematogenic distribution of ions from the peripherally implanted wear debris.

Animals↗