PubMed Health⌕ Search

Biomedical subjects

M Aït Saïd

Publications and source records attributed to M Aït Saïd.

2 recordsLinked to original sources

[New energy sources for ablative methods].

Radiofrequency current is the reference energy source for endocavitary ablation of arrhythmias. It is particularly well adapted for the ablation of focal arrhythmogenic substrates such as accessory pathways or foyers of automatism. Technological advances have made the lesions larger but the extension of the indications of percutaneous ablation to more complex substrates such as atrial fibrillation have justified the evaluation of alternative energies. The production of linear transmural lesions or deeper lesions which respect the parietal myocardial architecture and endocardial structure are a challenge for these energies. The capacity of functional mapping specific to cryogenics has provided this energy source with a clinical application for ablation of high risk structures whereas other energies, despite the chronicity of their experimental evaluation, are still at the stage of preliminary clinical trials with the sophisticated catheters in special indications.

Arrhythmias, Cardiac↗

[Automobile driving and implantable defibrillators].

The consequences of implanting an automatic cardioverter defibrillator (ICD) on vehicle driving in France are poorly known. This retrospective study examined the behaviour at the wheel of ICD recipients who were recommended to abstain from driving for 3 to 6 months after device implantation. The study population included 98 patients (mean age = 59.5 +/- 14.8 years) followed for a mean of 24. +/- 23.9 months, who underwent ICD implant for ventricular tachycardia (65% of patients ventricular fibrillation (15%), syncope (8%), as part of a research protocol of myocardial cell transplantation 6%, or for primary prevention (5%). The underlying heart disease was ischemic in 59% of patients dilated cardiomyopathy in 11%,hypertrophic cardiomyopathy in 8%, valvular in 6%. Brugada syndrome in 4%, right ventricular arrhythmogenic cardiomyopathy in 2%, and miscellaneous disorders in 9% of patients. Five patients died without post mortem interrogation of the ICD. Only 28% of drivers remembered, and 13% observed, the recommended driving limitations. However, 45% (the oldest) claimed to drive prudently. During follow-up, 47% of patients received an ICD shock. Their mean it ventricular ejection fraction was 34 +/- 14%, versus 43 +/- 18% in patients who received no ICD therapy (p = 0.015). Syncope occurred in 16% who received ICD shocks. Shocks were delivered during driving in 6 patients, without consequent accident. Despite their non-observance of recommended driving limitations. ICD recipients suffered few traffic accidents. Legislation in France should reproduce the guidelines issued by European professional societies and enacted by the British laws.

Accidents, Traffic↗