PubMed Health⌕ Search

Biomedical subjects

M Addy

Publications and source records attributed to M Addy.

At least 91 records · Page 5Linked to original sources

Evaluation of accuracy and variability of scoring-area-based plaque indices. A laboratory model.

BACKGROUND: Plaque scoring, using a variety of indices and methods, is widely used in clinical dentistry. There is limited information on inter- and intra-examiner variability and almost no data on examiner accuracy. AIMS: The aim of this study, was to determine the inter- and intra-examiner variability and accuracy of 15 examiners, of differing plaque-scoring experience, in recording and judging plaque areas from simulated plaque on tooth charts. METHODS: Plaque, shaded red, was drawn onto tooth charts of 8 simulated "patients" and measured by planimetry by 1 investigator. For each tooth for each "patient", examiners subjectively copied the plaque onto blank charts and scored plaque in 5% increments for the global plaque index. This was repeated on 2 occasions. Drawn plaque areas were determine by the investigator and comparisons made with the actual areas and % scores of plaque. RESULTS: For both plaque recording methods, intra-examiner variability was low and slightly better than inter-examiner variability. Reproducing plaque areas showed a high level of accuracy in most examiners, as was judging areas in 5% increments, albeit slightly less accurate than area drawing. Overall examiner experience had little influence on judging plaque areas. CONCLUSION: The data suggest that area-based plaque indices can be scored or recorded accurately and with minimal variability within or between examiners. The laboratory model could be used to train and assess examiners.

Dental Plaque↗

Comparative effects of quaternary ammonium mouthrinses on 4-day plaque regrowth.

BACKGROUND: Quaternary ammonium compounds constitute a large group of antibacterial chemicals with a potential for inhibiting plaque and gingivitis. One compound, benzalkonium chloride (BC), may be of value, although there is a dearth of evidence to support efficacy. The aim of this study was to measure the ability of 2 BC mouthrinses (0.05% and 0.1%) to inhibit de novo plaque reformation. METHOD: A 4-day plaque regrowth model. For comparative purposes, a commercial mouthrinse containing cetyl pyridinium chloride (CPC) and a positive control chlorhexidine (CX) mouthrinse were also evaluated. RESULTS: Compared to water control, a reduction in plaque scores of 52% was noted for the CX mouthrinse, 22.5% for CPC and 5% and 6% for the 2 BC rinses. For plaque area, reductions of 84%, 47%, 16% and 15% were found for CX, CPC, and the 2 BC rinses, respectively. Significant reductions in plaque area compared to the water rinse were also seen with the 2 BC rinses (p<0.05). However, for both plaque score and plaque area, the CX and CPC rinses significantly reduced plaque compared to the BC rinses (p<0.0001). CONCLUSIONS: These findings would suggest that the 2 benzalkonium rinses would only have a limited value at inhibiting plaque formation.

Analysis of Variance↗

Studies in vitro of abrasion by different manual toothbrush heads and a standard toothpaste.

BACKGROUND: Loss of dentine at the buccal cervical region of teeth has a multifactorial aetiology. However, a considerable amount of circumstantial evidence, supported by laboratory experiments, implicates toothbrushing with toothpaste as a consistent factor. Most interest has centred around the abrasivity of toothpastes, particularly since a toothbrush alone has negligible effects on dentine. The influence of filament stiffness on toothpaste abrasion was the subject of some studies, mostly at least 2 decades ago, and produced conflicting conclusions. Numerous changes to toothbrush design and construction have taken place in recent years. AIMS: The aim of this study was to measure the abrasion of a standard substrate, acrylic, by a standard toothpaste carried on modern brands of toothbrushes classified by manufacturers as hard (3 brands), medium (3 brands) and soft (6 brands). METHOD: The substrate was brushed for 20,000 strokes with at least 6 heads from each brand. Measurements of substrate loss were made at 5000 stroke increments by profilometry. RESULTS: Substrate loss for all brushes showed a pattern of abrasion which was to a first approximation linear. Overall, hard brushes caused least abrasion and soft brushes the most, with differences between groups being significant. Within-group differences between brands reached significance for soft and medium brushes but not hard brushes. CONCLUSIONS: The results could be explained by increased retention of toothpaste by smaller diameter filaments and denser tufts on soft brushes and the greater flexion of filaments increasing the area of contact with the surface. Calculations on the clinical outcome of these data in vitro indicate that toothbrushing with toothpaste alone would produce minimal damage to dentine even over many years. Differences between brushes therefore are probably of little clinical significance. Certainly, the data do not support the use of hard brushes, particularly in view of the potential detrimental effects to gingival tissues.

Hardness↗

Comparison of a double-textured prototype manual toothbrush with 3 branded products. A professional brushing study.

BACKGROUND: The consensus has been that there is no one superior design of manual toothbrush for plaque removal, despite, in some cases, encouraging findings from laboratory studies. The user appears the major variable and may mask differences in brush efficacy. AIMS: The aim of this study was to compare 2 new double-filament texture brushes with 3 established brands for plaque removal, under standardised conditions of professional brushing. METHOD: The study was a blind, randomised crossover design, balanced for residual effects. A panel of 15 subjects suspended tooth cleaning for 3 days. On day 4, plaque was scored from 6 sites per tooth before and after a 2-min professional toothbrushing. A washout period of at least 3 days was allowed between study periods. RESULTS: Overall plaque removal was 50% with no significant differences between brushes, a 3% absolute difference in average total mouth plaque separating brushes. However, at upper- and mid-buccal sites, a not significant 8% and a significant 9% difference, respectively, in plaque removal were recorded in favour of one of the prototype brushes, and at the mid-lingual site, there was a non-significant 10% difference in favour of one branded brush. Other sites were cleaned similarly by all brushes except for reduced plaque removal from buccal compared to lingual surfaces and interproximal compared to mid-surface sites. Highly significant subject differences in plaque removal were noted which may be relevant to inherent anatomical difficulties in tooth cleaning for some individuals. Period effects were not significant, supporting the consistency in brushing by the professional brusher. CONCLUSION: The method appeared capable of detecting small benefits of brush design. However, the benefits reported must be taken within the context of an overall lack of difference between brushes. The method could be used to set and record a minimum level of efficacy for toothbrushes.

Adult↗

The use of professional brushing to compare 3 toothbrushes for plaque removal from individuals with gingival recession.

BACKGROUND: Toothbrush filament configuration now varies considerably, usually with the intention of improving plaque removal overall or from specific sites. AIMS: The aim of the study was to compare 2 branded toothbrushes with a brush designed with a convex filament head arrangement to improve plaque removal from teeth with buccal gingival recession. METHODS: The study was a randomised, 3-treatment, double-blind crossover design balanced for residual effects and involving 18 healthy volunteers. On day 1, subjects suspended toothcleaning and returned to the clinic on day 4. Plaque was scored by area and index before and after 2 min of toothbrushing with the allocated brush. Brushing was performed by a hygienist allocating a timed 15 s to each of the 8 buccal and lingual quadrants. 3 days was allowed between treatment periods. RESULTS: Plaque accumulation differed considerably by site as did plaque removal. Overall plaque removal was 40%. Analysis showed significant subject differences but, no significant period or treatment differences. CONCLUSIONS: Consistent with other reports, it must be concluded that brush design is not a major variable in plaque removal. However using this "robot"-like model, the dentition of some individuals and specific dental surfaces are inherently more difficult to clean than others.

Adult↗

A study to assess the plaque inhibitory activity of a new triclosan mouthrinse formulation.

BACKGROUND/AIMS: Toothpastes and mouthrinses containing triclosan have been shown to be of some value at inhibiting both plaque and gingivitis. However much improved activity can be obtained by the addition of other chemicals which increase substantivity or antimicrobial activity. The present study was designed to determine whether a new mouthwash formulation containing a triglyceride oil was capable of reducing plaque reformation when compared to a control rinse containing neither triclosan or oil. METHODS: A total of 24 subjects took part in a double-blind, single-centre, cross-over study in which rinses were used as the only form of oral hygiene over a 4-day period. On the 1st day of each period, the subjects were given a prophylaxis to remove all plaque and calculus deposits. A single supervised rinse was taken and subsequent 2x daily rinses over the following 3 days. 24 and 96 h after the prophylaxis, the volunteers returned to the clinic, the plaque disclosed and assessed by plaque index and area. The test procedure and wash-out phase were repeated until all of the subjects had used both rinses. RESULTS: After 24 h, a 12% reduction in plaque score and a 25% reduction in plaque area was noted for the triclosan/oil rinse compared to the control rinse; however, these reductions were not significant (p>0.05). After 96 h, the triclosan/ oil rinse failed to produce a numerical or statistical reduction in plaque whether measured by plaque score or area. CONCLUSIONS: These findings would suggest that the triclosan/oil rinse would be of little value at inhibiting dental plaque whether used alone or as an adjunct to conventional oral hygiene measures.

Adult↗

Erosion of dentine and enamel in vitro by dietary acids: the effect of temperature, acid character, concentration and exposure time.

Sales of soft drinks has been increasing by 56% over the last 10 years and are estimated to keep rising at about 2-3% a year. Further, the reported incidence of tooth erosion has been increasingly documented. Whilst these factors could well be linked, many individuals with erosive diets are not presenting with erosion. This would suggest the effects of many variables, hence the aim of these investigations. Methodologies included preparing enamel and dentine samples from unerupted human third molars. Groups of five specimens were placed in citric acid over a temperature range of 5-60 degrees C for 10-min exposures; placed in citric, lactic, malic or phosphoric acid (0.05, 0.1, 0.5, and 1% (w/v)) for 10-min exposures; and placed in the same three organic hydroxy acids at 0.3% (w/v) or phosphoric acid at 0.1% (w/v) for 3 x 10-min exposures. Tissue loss was determined by profilometry. Results showed that increasing temperature, concentration and exposure time increased the erosion of dentine and enamel. This study has shown that under highly controlled conditions, erosion of dentine and enamel by dietary acids can be greatly influenced in vitro by temperature, concentration, type of acid and exposure time. These factors could be employed in order to reduce the erosivity of soft acidic drinks.

Adolescent↗

Dentine hypersensitivity - an enigma? A review of terminology, mechanisms, aetiology and management.

Dentine hypersensitivity is a relatively common problem experienced in clinical dental practice. This condition may disturb the patient during eating, drinking, brushing and sometimes even breathing. Therapeutic intervention by desensitising agents may provide only partial pain relief and recurrence is common. Much remains unknown about dentine hypersensitivity, even the terminology can be questioned. Most of the literature over decades has been concerned with reporting clinical trials proving the efficacy of numerous treatments for dentine hypersensitivity. Indeed, besides haemorrhoids, there can be few other diseases or conditions known to man that can apparently be successfully treated by so many and extremely varied agents and formulations applied topically. This paper will discuss the epidemiology, mechanisms of pain production and aetiological factors for the condition in the hope of developing ideas for more realistic prevention and management strategies.

Dentin Sensitivity↗

Development and evaluation of a low erosive blackcurrant juice drink. 3. Final drink and concentrate, formulae comparisons in situ and overview of the concept.

OBJECTIVE: Two previous studies demonstrated that a blackcurrant juice drink with added calcium produced little erosion of enamel in vitro and in situ by comparison with other low pH fruit drinks. The primary aim of this study was to demonstrate that the final formulation drink and concentrate were of similar low erosivity. Secondary aims were to provide more data on the erosivity of other fruit drink concentrates and whether erosion was influenced by anterior and posterior palate siting of enamel specimens. METHOD: The study was a single centre, single blind, randomised placebo controlled 5 cell crossover design involving 15 volunteers. The test drinks were blackcurrant juice/calcium concentrate, blackcurrant juice/calcium drink, proprietary apple & blackcurrant juice concentrate, proprietary orange drink concentrate and water. Four enamel samples were retained in situ, 2 anterior palate and 2 mid/posterior palate, on upper removable acrylic appliances. Drinks were 250 ml volumes consumed 4 times per day during 15 working days. Concentrates were diluted 50 ml in 200 ml water. Measurements of enamel loss were made on one anterior and one posterior sample on days 2, 5, 10 and 15 by profilometry. RESULTS: One subject approached the 20 microns erosion limit by day 10 on the orange drink and was withdrawn from that cell. Differences in mean erosion between anterior and posterior sites were variable and small. By day 15 the mean losses of enamel averaged over anterior and posterior were blackcurrant/calcium concentrate 0.28 micron, blackcurrant/calcium drink 0.35 micron, apple & blackcurrant concentrate 2.04 microns. orange concentrate 8.29 microns and water 0.08 micron. Except at day 15 for the blackcurrant/calcium drink the erosion by the blackcurrant/calcium formulations was not significantly different from water at any time point. Erosion by the apple & blackcurrant and orange concentrate drinks was highly significantly greater than the blackcurrant/calcium drinks at all but the 2 day time point for the apple & blackcurrant concentrate drink compared to the blackcurrant/calcium drink. CONCLUSIONS: All data thus far indicate that dependant on tooth site susceptibility and the specific drink, the consumption of standard low pH fruit drinks could result in 1 mm loss of enamel in periods ranging from as little as 2 years to 20 years. Similar erosion by the low pH blackcurrant drinks with added calcium would take in excess of 100 years.

Adult↗

Development and evaluation of a low erosive blackcurrant juice drink in vitro and in situ. 1. Comparison with orange juice.

OBJECTIVE: The aim of this study was to determine whether an experimental blackcurrant juice drink with added calcium was less erosive to enamel both in vitro and in situ compared with a proprietary orange juice product. METHODS: The study was a single centre, blind, randomised, placebo controlled three cell crossover design. An intra oral appliance capable of retaining one enamel sample in situ was constructed and worn by 12 volunteers. The drinks under test were orange juice, the experimental blackcurrant juice drink with calcium and water. Drinks were consumed as 250 ml volumes four times during the working day under supervision for 15 days. The same methodology was modelled in vitro. Measurements of enamel loss were made by profilometry. RESULTS: Water, the experimental blackcurrant juice drink and orange juice produced 0.19, 0.41 and 2.54 microns loss of enamel respectively in situ and 0.0, 5.2 and 22.18 microns loss of enamel respectively in vitro. All differences between pairs of drinks in situ and in vitro were statistically significant. CONCLUSIONS: Data using this model in situ were only available for orange juice and this was therefore considered as a positive control with water a placebo control. The results have demonstrated that the experimental blackcurrant juice drink with calcium is markedly less erosive than orange juice, particularly and importantly in situ. The experimental blackcurrant juice drink has limited erosive potential to teeth and deserves further comparative investigation and development as a low pH fruit drink for public consumption.

Adult↗

Development and evaluation of a low erosive blackcurrant juice drink. 2. Comparison with a conventional blackcurrant juice drink and orange juice.

OBJECTIVE: A previous study demonstrated that an experimental low pH blackcurrant juice drink with calcium was markedly less erosive to enamel both in situ and in vitro than orange juice. Further development of the experimental blackcurrant juice drink formula has occurred and the aims of the present studies were two fold. Firstly, to confirm the low erosivity of the modified formulation and secondly, to provide more comparative data with other acidic fruit drink products. METHOD: The study was a single centre, single blind, randomised placebo controlled 4 cell crossover design involving 12 healthy volunteers. The test drinks were orange juice, water, experimental blackcurrant juice drink with calcium and a proprietary blackcurrant juice drink. Enamel samples were retained in situ at the mid palatal regions using intraoral appliances and exposed to 250 ml volumes of the drinks 4 times per day during 15 working days. Measurements of enamel loss were made by profilometry. The same method was modelled in vitro. RESULTS: By day 15 the mean losses of enamel in situ for orange juice, water, experimental blackcurrant juice drink with calcium and blackcurrant juice drink were 1.70, 0.05, 0.44 and 2.75 microns respectively. At all bar one measurement, the loss of enamel was significantly greater for all fruit drinks compared to water. Losses caused by the blackcurrant juice drink with calcium were significantly less than the other two fruit drinks at all time points. Losses of enamel by day 15 in the study in vitro were 13.02, 0.00, 1.78 and 39.02 microns respectively. The blackcurrant juice drink with calcium was not significantly different from water at days 3 and 6, otherwise all pairwise comparisons for differences between the 4 drinks at each time period were significant. CONCLUSIONS: The methodologies in situ and in vitro again appear to correlate in ranking the order of erosivity of drinks. The data particularly from the study in situ allude to the very low comparative erosivity of the further modified experimental blackcurrant juice drink with calcium and support the further development of such drinks for public consumption.

Adult↗

An in vitro assessment of the dentine lost during instrumentation using the Periosonic system.

This study investigated the ability of a new instrument designed for root debridement, the Periosonic, to remove dentine compared to a hand curette and an ultrasonic scaler. The Periosonic system is a modification of the Micro-Megax endodontic system and uses modified files to remove plaque, calculus and tooth substance. The Periosonic has 2 file types; the Periosonic 1 is a more aggressive file for the removal of gross supra- and subgingival deposits, while the Periosonic 2 is a thinner more flexible file used for the removal of subgingival deposits. 40 human dentine specimens were ground flat and baseline measurements were made using a surfometer. The specimens were divided into 4 experimental groups and each group was treated with a hand curette, ultrasonic scaler, Periosonic 1 or 2 using 12, 1-s strokes. The specimens were remeasured blind in the surfometer. The curette removed 23.6 microm of dentine, the ultrasonic 6.8 microm, the Periosonic 1 18.8 microm and the Periosonic 2 12.5 microm. A qualitative assessment of the samples following mechanical preparation was also made. In conclusion, the Periosonic instrument does not remove more tooth substance than a conventional curette and may be a useful addition for the debridement of root surfaces.

Dental Instruments↗

Plaque regrowth studies: discriminatory power of plaque index compared to plaque area.

A large number of plaque-scoring methods exist for the evaluation of plaque inhibition by oral hygiene agents, products or devices. The ability of such methods to discriminate between high and low plaque scores has not been compared. In this retrospective analysis, the F-ratios for differences between treatments for plaque index and area were compared from 15, 4-day plaque regrowth studies. F-ratios favoured plaque index as having greater a discriminatory power compared to plaque area in 2/3 of the studies considered. It is concluded that, when appropriate, 2 scoring methods for plaque should be used, but if a choice is necessary, plaque index is likely to provide the greater discriminatory power over plaque area.

Analysis of Variance↗

The development and validation of an occlusal site-specific plaque index to evaluate the effects of cleaning by tooth brushes and chewing gum.

These studies sought to develop and validate an occlusal site-specific plaque index to be used to measure plaque removal by brushing or chewing gum. The index divides the occlusal surfaces into imaginary zones from which scores are apportioned on a 0-4 basis dependent on the perceived % plaque coverage of each zone. Examiner calibration was conducted over 2 studies assessing inter-examiner reproducibility and intra-examiner repeatibility, respectively. Study 1 involved 2 examiners who recorded scores from the same 3 groups of subjects who had suspended tooth cleaning for 4 days. Analyses for inter-examiner reproducibility showed no significant mean differences between examiners or no significant differences between variances of the 2 examiners scores. Study 2 involved the same 2 examiners individually scoring 3 groups of subjects 2 x (approximately 60 min apart) for occlusal plaque. Analysis for intra-examiner repeatability showed no significant mean differences between the 2 scorings of each examiner. Furthermore, there were no significant differences between the variances of each examiner's scores except for 1 examiner in the repeatability exercise for the 1st group of subjects. Study 3 involved groups of subjects at 2 separate clinical sites (Bristol, England and Berne, Switzerland) being scored for occlusal plaque before and after toothbrushing with water or after no toothbrushing. Data from individual examiners and examiners combined revealed a significant reduction in occlusal plaque with brushing compared to no brushing. Study 4 was the same as study 3 but occlusal plaque was scored before and after chewing gum or not chewing gum. The Bristol examiner recorded a significant reduction in plaque by chewing gum compared to not chewing gum but the Berne examiner did not. The latter may have resulted from a considerable disparity in the number of evaluable occlusal surfaces between the two study sites. The index could be employed as part of the overall assessment or oral hygiene or used in clinical trials to study mechanical and chemical plaque control agents.

Adult↗

A 24-h regrowth study to evaluate the plaque inhibitory properties of a proprietary liquid dentifrice.

Dentifrices have typically been formulated as pastes. Recently however, a number of liquid products have become available. The chemical plaque inhibitory activity of such products has so far received little attention. The aim of this study was to determine the plaque inhibitory effect of a proprietary liquid dentifrice by comparison to a negative control (water) and a conventional fluoride toothpaste. The study design was a randomised single centre, single blind 3-way cross-over trial with the objective of validating claims of plaque inhibition for the liquid dentifrice. Volunteers were rendered plaque free then asked to brush for one minute with one of the three test products, following which they abstained from oral hygiene for the subsequent 24 h. The plaque area was recorded and then measured planimetrically. The results showed that more plaque accumulated with water and the liquid dentifrice compared with the fluoride toothpaste. Thus, there was a statistically significant difference between the fluoride toothpaste and water and between the fluoride toothpaste and the liquid dentifrice. There was no significant difference between the liquid dentifrice and water. It is concluded that in this particular model system, the liquid dentifrice provided little chemical plaque inhibitory action.

Adult↗

An evaluation of video instruction for an electric toothbrush. Comparative single-brushing cross-over study.

Instructions on the use of electric toothbrushes are usually derived from the written and/or diagrammatic leaflets provided with the device or perhaps less often instruction from a professional. Videos are now widely used for information transfer and the direction of physical activities. The aim of this study was to determine whether video instruction in the use of an electric toothbrush could promote efficient use of the device. The 2-min video demonstrated the use of an oscillating, rotating electric toothbrush used by a hygienist for 15 s in each buccal and lingual quadrant. A voice-over directed the observer to follow the hygienist's movements. The study was planned as a 2-phase, single-examiner blind, randomised, cross-over study accepting there would be confounding of the 2nd period by carry-over from the 1st. A group of 24 healthy volunteers participated who had average oral hygiene and never used an electric toothbrush. 12 subjects received the video first (VN) and 12 subjects the instructional leaflet with the device (NV). Single brushings were performed after suspending tooth cleaning for 48 h. Plaque was scored before and after brushing. A 2-week washout period was permitted before the crossover. In period 1, plaque removal with the video was overall significantly greater than with written instructions. The effects for posterior teeth were greater than anterior and comparison between groups for posterior minus anterior differences were highly significant in favour of the VN group. In period 2, the effect of period was dominant with both groups achieving greater plaque removal in period 2 than period 1. Plaque removal by group VN remained considerably greater than group NV Despite the confounding influences of carry-over in this particular design of study, the results support the idea that video instruction for electric toothbrushes could be a simple and efficient way of improving plaque removal by these devices. The methodology needs to be verified in a home-use type of investigation.

Adult↗

Conversion of plaque-area measurements to plaque index scores. An assessment of variation and discriminatory power.

Plaque areas recorded graphically or photographically provide a permanent record of plaque accumulations on teeth at a moment in time. As such, these records could be re-evaluated and converted into other index scores. The purpose of this study was to determine the reproducibility of scoring a plaque index from previously recorded plaque areas and to compare such scores with the original scores of the same index. A randomised blind, crossover study comparing 5 treatments for plaque inhibition scored by plaque area and index was chosen. 2 examiners, the original scorer PRH and another, NC, 2x scored the plaque area tooth charts according to the criteria of the plaque index system used in the original study. Standard deviations of the differences showed intra-examiner repeatability to be high particularly for the original examiner. Inter-examiner reproducibility for the original index scores was considered good but less than for intra-examiner repeatability. Correlation coefficients were complimentary to the differences analysis, being very high within examiners and less high for between examiners and original and rescored index. Separation between distributions of plaque area measurements for consecutive values of the index were particular good for scores 2 versus 3 and 3 versus 4 and less good for 1 versus 2 and 4 versus 5. Reanalysis of the study for treatment differences using rescored data revealed a similar level of significance as using the original data. Rescored index had similar discriminatory power for the study as plaque area and original plaque index when both were derived from the same buccal tooth surfaces. However, discriminatory power was less by comparison with original plaque index derived from the buccal surfaces of all teeth. It is concluded that plaque area provides a permanent record of plaque distribution which can be converted into index data at a later date. Such data collection could make possible comparisons between studies using different indices.

Cross-Over Studies↗

Comparison of video and written instructions for plaque removal by an oscillating/rotating/reciprocating electric toothbrush.

A previous crossover study showed that a watch-and-follow instructional video improved plaque removal by an electric toothbrush compared to the use of the instructional leaflet. This study employed a parallel design to assess the value of an instructional video for plaque removal by a new model oscillating/rotating/reciprocating electric toothbrush. 2 groups of 26 dentate subjects with average oral hygiene, who had never used an electric toothbrush, participated in this single blind, randomised parallel group designed study. On day 1 of the study, subjects received a professional prophylaxis to remove all plaque. Oral hygiene measures were then suspended and subjects returned on day 3 when a prebrushing plaque score was recorded by plaque index and area. Subjects withdrew and either read the manufacturers instructional leaflet (group L) or observed the instructional video (group V). Groups L and V then performed toothbrushing with toothpaste for 2 minutes and with group V brushing in time with the instructional video. Post-brushing plaque indices and areas were then recorded. Whole mouth, lingual, upper, lower, anterior and posterior but not buccal % reductions in plaque index and area were significantly greater in group V compared to group L. % plaque removal was also significantly greater by area at mid and distal sites but not mesial sites. Whole-mouth plaque reductions were 10% greater in group V but reached >15% at lingual surfaces. Within group differences in plaque removal at paired sites e.g., buccal/lingual, remained similar, suggesting that further improvement could be achieved by modifying the video to devote more time to the difficult-to-clean areas. In conclusion, in the early period of learning the use of an electric toothbrush, plaque removal can be improved by using an instructional video. Such watch-and-follow video routines could be extended to other areas of oral hygiene practices.

Adult↗