PubMed Health⌕ Search

Biomedical subjects

M Arambarri

Publications and source records attributed to M Arambarri.

7 recordsLinked to original sources

[Therapy with interferon plus ribavirin in hemodialysis patient with PCR-positive viral hepatitis C].

Traditionally, the treatment of viral hepatitis C (positive Polymerase Chain Reaction -PCR-) was with Interferon. A combination of Interferon plus Ribavirin has been producing better results in last years. Currently, Ribavirin is not indicated for patients with Chronic Kidney Disease because of a high risk of severe anaemia. In a few cases, this treatment is producing good results with previous dose adjustment. We show a case of a 28-year-old man with Chronic Kidney Disease on treatment with periodical hemodialysis and chronic hepatopathy HCV Positive RNA HCV (> 1,000,000 copies/ml) and persistent transaminase elevation. Before kidney transplantation, we decided to use Interferon (3,000,000 IU/48 hours) and Ribavirin (200 mg/24 hours) treatment. After 15 days, we saw normal transaminase values and HCV RNA was negative. The patient required temporary suspension of Ribavirin and two red blood cell transfusions due to severe anaemia. Ribavirin was reintroduced 200 mg/48 h posthemodialysis. The patient did not present any complication again, and could be treated for 14 months. After next 11 months of evolution the patient has normal rates of liver function and negative HCV RNA values.

Adult↗

[Membranous nephropathy associated to autoimmune thyroiditis, chronic pancreatitis and suprarrenal insufficiency].

A 33 year old female was admitted to the hospital to study aedema and bocio, A nephrotic syndrome was diagnosed and the renal biopsy demonstrated membranous glomerulonephritis, stage II. She was also diagnosed of Hashimoto's autoinmmune thyroiditis: TSH (41.5 uUl/ml), T4 (0.07 ng/dl), antithyroglobuline (1/2560) and antimicrosome (1/6400). Four year latter she was diagnosed of autoinmmune pancreatitis, without evidence of diabetes mellitus or exocrine pancreatic insufficiency. Eight years latter she was diagnosed of primary autoimmune suprarrenal insufficiency: basal cortisol: 2.7 mcg/dl, post ACTH estimulated cortisol: 5.6 mcg/dl, antinuclear antibody (1/160) and antiparietal (1/320). We present a pluriglandular autoimmune syndrome with membranous glomerulonephritis, thyroiditis, pancreatitis and suprarrenal insufficiency. To the best of our knowledge this complex syndrome has not been previously described.

Adrenal Insufficiency↗

Renal transplant recipient outcome after losing the first graft.

Renal transplantation is the optimal therapy for end-stage renal failure and considerable attention has been given to graft and patient survival and the effectiveness of immunosuppressive regimens. However, little attention has been given to outcome for patients who lose their grafts. We retrospectively reviewed the outcomes of the 793 first renal transplants performed at our institution between November 1979 and December 2001. A total of 348 patients lost their grafts, 116 by death with a functioning graft (33.3%) and 232 patients for other causes (66.7%). Eighty-six patients (37.1%) received a second transplant 3.5+/-2.4 years after returning to dialysis and the remainder continued on dialysis. Retransplanted patients were younger at the time of the first transplant (P=.000), and both time on dialysis (P=.012) and duration of graft function (P=.057) were shorter than for those remaining on dialysis. Therefore, retransplant patient survival at 1, 5, and 10 years was better than among those patients on dialysis not included on the waiting list (P<.001), but when compared with the relisted patients the survival rate was almost identical (96%, 85%, and 67% vs 97%, 82%, and 67%; P=NS). Almost 40% of patients who lost their first grafts were retransplanted. We did not observe differences in patient survival between retransplant and relisted patients. Because the number of cases is limited, our results need to be confirmed by larger series.

Adult↗

European multicentre evaluation of the Super Aution SA-4220 urinalysis analyser.

A multicentre evaluation of the urine test strip analyser Super Aution-4220 was carried out in six laboratories. The analytical performance of the instrument with regard to imprecision, linearity, detection limit, drift, carry-over and method comparison was studied. Using the Aution stick 8 test strip the pH, glucose, protein, ketones, bilirubin, blood, urobilinogen and leukocyte esterase were analysed. Specific gravity measurements were performed by refractive index method. Within-run and between-run imprecision determined at three levels of analyte were good. No carry-over was observed. Obtained results were linear through all the described analytical range. No significant drift was detected. Method comparison with some quantitative methods was performed and showed a good correlation with most of the analytes. The study of interferences showed minor interferences by common therapeutic drugs with the measurement of some analytes. During the assessment period of about 6 months no breakdown occurred in any laboratory. The Super Aution urine analyser appeared to be a highly automated analyser of urinary test strips. The operation was simple and the maintenance required only a few minutes a day.

Artifacts↗

[Interference in blood coagulation tests on lipemic plasma. Correction using n-hexane clearing].

PURPOSE: To eliminate the bias in the plasmatic coagulation test caused by lipemic samples by means of with addition of n-hexane in the ACL-3000 analyzer (Instrumentation Laboratory). MATERIAL AND METHODS: The turbidity caused by lipemia was simulated by addition of increasing quantities of Intralipid 20% (interferent) to samples from patients with normal pathological coagulation tests (with oral anticoagulant therapy). We compared the results of PT (prothrombin time), fibrinogen (derived) and APTT (activated partial thromboplastin time) before and after the addition of n-hexane. RESULTS: In samples with an elevated concentration of interferent (> 9.79 mmol/L of triglycerides) the analyzer failed to give any results. Once the lipids were cleared by n-hexane, the analyzer offered results for all the samples, which coincided with the original sample after applying a correction factor 1.06 to the TP and 0.88 to the TTPA. CONCLUSION: The addition of n-hexane is a valid method to eliminate the bias caused by the lipids in the coagulation tests.

Artifacts↗

[Ionic dialysance to control the dose of dialysis. One year experience].

The Diascan equipment (Hospal) measures ionic dialysane which it derives the K and the Kt. If we divide the Kt obtained with Diascan between the Kt/V obtained by a simplified formula, it result a value of V for every patient. Entering this V in the Diascan software we can obtain a Kt/V (Diascan Kt/V), similar in theory to the simplified Kt/V. In the year 2002 we have controlled the delivered dialysis in our unit with the Diascan Kt/V. The aim of the present study was to study the agreement between de Diascan Kt/V and the Lowrie Kt/V. During the year 2002, 63 patients have been dialyzed in monitors with Diascan equipment. We calculated the V of each patient by dividing the Kt Diascan between the Lowrie Kt/V in the same dialysis session. The mea of the two consecutive measurements was considered the V value. Throughout the year 2002, 7 agreement studies were realized. The inter-method variability was assessed by the relative difference (absolute difference Diascan Kt/V-Lowrie Kt/V, divided by the average of both tests). A good agreement was considered when the relative difference was equal or lower than 10%. In the 7 agreement studies realized, the mean of the relative difference oscilled between 5.2 and 6.6%, and the percentage of patients with a relative difference equal or lower than 10% oscilled between 83 and 91%. During a month, the Diascan Kt/V was controlled in all dialysis sessions in 41 patients (554 sessions in total). Failure in the lecture of Kt/V Diascan was observed in 41 sessions (7%). A Diascan Kt/V greater than 1 (the minimum delivered dialysis considered in our unit) was obtained in 93% of the valid sessions. 38 of 41 patients had a mean monthly Diascan Kt/V greater than 1. The coefficient of variability of any patient oscilled between 2.1 and 12.4% (mean 5.1%). Diascan Kt/V is good procedure for the monitoring the delivered dialysis without blood sampling or any additional costs.

Evaluation Studies as Topic↗