PubMed Health⌕ Search

Biomedical subjects

M Asell

Publications and source records attributed to M Asell.

4 recordsLinked to original sources

IMRT for breast. a planning study.

BACKGROUND AND PURPOSE: To evaluate the performance of ten different treatment-planning systems when intensity modulated (IMRT) plans are designed for breast treatments that include the irradiation of the internal mammary chain. PATIENTS AND METHODS: A dataset of five patients (CT images and volumes of interest) was distributed to design IMRT plans on the ten systems. To minimise biases, the same geometry and clinical planning aims were imposed on the individual plans. Results were analysed in terms of dose distributions and dose volume histograms. RESULTS AND CONCLUSIONS: For target coverage, the volume receiving more than 95% of the prescribed dose ranged from 77% (OTP) to 91% (Eclipse and Pinnacle), the volume receiving more than 107% ranged from 3.3% (Hyperion) to 23.2% (OTP). The mean dose to ipsilateral lung ranged from 13 Gy (Eclipse) to 18 Gy (OTP). The volume of the contralateral breast receiving more than 10 Gy ranged from 3% (Pinnacle) to 26% (Precise). The volume of heart receiving more than 20 Gy ranged from 7% (Eclipse) to 47% (Precise), the maximum significant dose to heart ranged from approximately 27 Gy (XiO) to approximately 49 Gy (Precise). The maximum significant dose to healthy tissue ranged from approximately 51 Gy (Eclipse) to approximately 62 Gy (OTP). It was also possible to show that the treatment geometry proposed here enables to minimise contralateral breast irradiation while keeping minimal ipsilateral lung (or heart) involvement and satisfactory target coverage.

Breast Neoplasms↗

Optimal electron and combined electron and photon therapy in the phase space of complication-free cure.

The possibility of using intensity-modulated high-energy electrons beams alone or in combination with photon beams to treat tumours located at depths from 5 cm to 25 cm has been investigated. A radiobiologically based optimization algorithm using the probability of complication-free tumour control has been used to calculate the optimal dose distributions. Two different target volumes have been used; one advanced cervical cancer with locally involved lymph nodes and one astrocytoma in the upper brain hemisphere. Treatments with only electron beams and also combinations between electron and photon beams have been investigated. The dependence of the expected treatment outcome on the beam energy and directions was investigated, and to some extent on the number of beam portals. It is shown that the beam direction intervals resulting in a high expected treatment outcome increase with increasing electron energy and also with some electron-photon combinations. For an eccentrically placed, not too deeply situated tumour surrounded by sensitive normal tissue it is shown that the expected treatment outcome can be improved by using electron beams in combination with photon beams compared with using two photon beams, and using two electron beams results in almost as high an expected treatment outcome. The possibility of improving the dose conformity from electron beams by adding photon fields parallel or orthogonal to the electron beams is demonstrated.

Algorithms↗

Target, purging magnet and electron collector design for scanned high-energy photon beams.

A new method for producing very narrow and intense 50 MV bremsstrahlung beams with a half-width as low as 35 mm at a distance of 1 m from the target is presented. Such a beam is well suited for intensity modulation using scanned photon beams. An algorithm has been developed to minimize the width of the bremsstrahlung beam generated in a multilayer target by varying the individual layer thicknesses and atomic numbers under given constraints on the total target thickness and the mean energy of the transmitted electrons. Under such constraints the narrowest possible bremsstrahlung beam is obtained with a target composed of layers of monotonically increasing atomic number starting with the lowest possible value at the entrance side where the electrons impinge. It is also shown that the narrowest photon beam profile is associated with the highest possible forward photon yield. To be able to use the optimized target clinically it is desirable to be able to collect and stop all the electrons that are transmitted through the target. The electrons are most efficiently collected if they are kept close together, i.e. by minimizing the multiple scatter of the electrons and consequently the half-width of the generated bremsstrahlung beam. This is achieved by a thin low-atomic-number target. A dedicated electron stopper has been developed and integrated with the purging magnet. When the electron stopper is combined with a purging magnet, a primary photon collimator and a multileaf collimator, almost all of the transmitted electrons and their associated bremsstrahlung contamination can effectively be collected. The narrow photon beams from thin low-atomic-number targets have the additional advantage of producing the hardest and most penetrative photon spectrum possible, which is ideal for treating large deep-seated tumours.

Algorithms↗

Optimization of 3D conformal electron beam therapy in inhomogeneous media by concomitant fluence and energy modulation.

The possibilities of using simultaneous fluence and energy modulation techniques in electron beam therapy to shape the dose distribution and almost eliminate the influences of tissue inhomogeneities have been investigated. By using a radiobiologically based optimization algorithm the radiobiological properties of the tissues can be taken into account when trying to find the best possible dose delivery. First water phantoms with differently shaped surfaces were used to study the effect of surface irregularities. We also studied water phantoms with internal inhomogeneities consisting of air or cortical bone. It was possible to improve substantially the dose distribution by fluence modulation in these cases. In addition to the fluence modulation the most suitable single electron energy in each case was also determined. Finally, the simultaneous use of several preselected electron beam energies was also tested, each with an individually optimized fluence profile. One to six electron energies were used, resulting in a slow improvement in complication-free cure with increasing number of beam energies. To apply these techniques to a more clinically relevant situation a post-operative breast cancer patient was studied. For simplicity this patient was treated with only one anterior beam portal to clearly illustrate the effect of inhomogeneities like bone and lung on the dose distribution. It is shown that by using fluence modulation the influence of dose inhomogeneities can be significantly reduced. When two or more electron beam energies with individually optimized fluence profiles are used the dose conformality to the internal target volume is further increased, particularly for targets with complex shapes.

Algorithms↗