PubMed Health⌕ Search

Biomedical subjects

M B Hürzeler

Publications and source records attributed to M B Hürzeler.

At least 19 recordsLinked to original sources

A tissue engineered cell-occlusive device for hard tissue regeneration--a preliminary report.

Tissue engineering is an emerging discipline that applies engineering principles to create devices for the study, restoration, modification, and assembly of functional tissues and organs from native or synthetic sources. In the field of guided bone regeneration (GBR), cellular matter engineering has been applied, more or less successfully, to the development of biodegradable and bioresorbable devices with chemical, physical, or mechanical properties, structure, or form that permit active tissue integration with desirable cell types and tissue components. The employment of synthetic and naturally occurring polymers as well as sophisticated manufacturing technologies allow the tissue engineering of matrix configurations so that the biophysical limitations of mass transfer can be satisfied. The configuration of such a hybrid matrix can also be manipulated to vary the surface area available for cell attachment, as well as to optimize the exposure of the attached cells to nutrients. A biodegradable and bioresorbable device made of synthetic and natural polymers was engineered specifically for GBR procedures. The degradation and resorption kinetics as well as the mechanical properties give the device the potential to function as a carrier for bone growth factors. This innovative device was applied as a GBR membrane in a clinical investigation in seven patients.

Absorbable Implants↗

Contribution of the periosteum to bone formation in guided bone regeneration. A study in monkeys.

The periosteum has been referred to as a protective barrier in the regeneration of bone defects. The objective of this study was to determine the contribution of periosteum as a natural barrier to bone formation in guided bone regeneration. Mucoperiosteal flaps were elevated bilaterally on the buccal aspect of the mandibular angle in 5 cynomolgus monkeys. Bleeding was induced by perforating the cortical bone. A hemispherical titanium mesh was fixed over the areas thus creating a void 5 mm in height between the mesh and the bone surface. One one side the mesh was covered with an ePTFE membrane (test side). The contralateral side did not receive further treatment (control side). After 4 month healing, histomorphometric analyses were used to determine the percentage of new bone in the void underneath the mesh, and the ratio between mineralized tissue and marrow spaces in new and old bone. The mean percentage of new bone tissue was 77.2 +/- 7.5% for the test sides and 68.6 +/- 8.4% for the control sides (P = 0.018, t-test). This new bone contained 80.0 +/- 3.6% mineralized tissue in the test group and 82.5 +/- 5.0% in the control group (P > 0.05, t-test). In both groups the newly formed bone exhibited significantly less mineralized tissue than the old bone (P < 0.05, t-test). It is concluded from this study that new bone formation was enhanced by the additional use of an ePTFE membrane under a periosteum-lined mucoperiosteal flap when space maintenance was excluded as a critical factor.

Animals↗

Utilization of the surgical microscope for advanced plastic periodontal surgery.

The increased demand for mucogingival aesthetics has required the optimization of periodontal procedures. Microsurgery is a minimally invasive technique that is performed with the surgical microscope and adapted instruments and suture materials. While this hardware and knowledge of various operations are necessary to achieve patient aesthetic expectations, clinicians must be willing to undergo an extended period of systematic training to become familiar with novel operating procedures and instruments. This article describes the application of the surgical microscope to provide enhanced perioplastic treatment.

Absorbable Implants↗

Comparison of bioabsorbable and bioinert membranes for guided bone regeneration around non-submerged implants. An experimental study in the mongrel dog.

The aim of this clinical investigation was to evaluate the effect of guided bone regeneration around non-submerged implants using different barrier membranes. Five adult mongrel dogs were used in this investigation. After having all premolars extracted and implant osteotomies performed in the regions of the former premolars, buccal bone defects were created. Subsequently, 3 implants were placed and the defects treated with 1 of the following 3 modalities: a) guided bone regeneration using an expanded polytetrafluoroethylene membrane, b) guided bone regeneration using a bioabsorbable membrane made from a synthetic copolymer of glycolide and lactide and c) no membrane application. Following implant and membrane placement, the mucoperiosteal flaps were repositioned and tightly sutured around the neck of the implants allowing for a non-submerged healing. After a healing period of 6 months, the animals were sacrificed and the specimens processed for histologic evaluation. The clinical pre-treatment defects between the different treatment groups were not statistically different (bioinert membrane group: 4.9 mm; control group: 4.8 mm; bioabsorbable membrane group: 4.5 mm). The remaining histological defects after 6 months of healing amounted to approximately 2.5 mm in the bioinert membrane group, 5.7 mm in the control group and 6.0 mm in the bioabsorbable membrane group. A significant difference was observed between the bioinert membrane group and the other 2 groups. The mineralized bone-to-implant contact in the bioinert membrane group was 51.5%, in the control group 46.3% and in the bioabsorbable membrane group 37.5%. The values between the bioinert membrane group and the bioabsorbable membrane group were statistically different. The results of this study indicate that bone regeneration with bioinert e-PTFE membranes around non-submerged implants is possible. The utilized absorbable polyglycolic/polylactid membrane did not show any bone regenerative effect and the results did not differ from the control group without membrane application.

Absorbable Implants↗

Functional and esthetic outcome enhancement of periodontal surgery by application of plastic surgery principles.

The closure of surgical wounds in a layer-by-layer fashion, a common principle of plastic surgery, is applied in this article to the field of periodontal surgery with the introduction of a new flap design. The suggested technique is indicated with all periodontal procedures that aim for hard and soft tissue augmentation (guided bone regeneration, mucogingival surgery, or plastic periodontal surgery) where passive, tension-free wound closure is fundamental for wound healing and a successful functional and esthetic outcome. By means of a series of incisions, buccal and lingual flaps are split several times; this results in a double-partial thickness flap and a coronally positioned palatal sliding flap, respectively. Thus, several tissue layers are obtained and the passive advancement of flaps becomes possible for the coverage of augmented areas. Wound closure with microsurgical suture material is accomplished in a multilayer approach, which ensures adaptation and closure of the outer tissue layers without any tension. Two case reports demonstrate the new plastic periodontal approach.

Esthetics, Dental↗

A single-incision technique to harvest subepithelial connective tissue grafts from the palate.

This article describes a new and simplified surgical approach to harvest subepithelial connective tissue grafts from the palate. For this procedure, only a single incision parallel to the gingival margin is used to access the donor site for graft preparation and harvesting. Grafts of variable size and thickness can be obtained. Since no band of epithelium is removed with the connective tissue graft the palatal donor site can heal with primary intention. No stents or hemostatic agents are necessary to cover the donor area postoperatively, and suturing can be reduced to a minimum. The harvesting technique is illustrated step by step, and the clinical application of connective tissue grafts harvested with the proposed method is demonstrated with the coverage of a gingival recession.

Adult↗

Reconstruction of the lost interproximal papilla--presentation of surgical and nonsurgical approaches.

Modern esthetic dentistry involves not only the restoration of lost teeth and their associated hard tissues, but increasingly the management and reconstruction of the encasing gingiva with adequate surgical techniques. The loss of interproximal dental papillae may cause functional, phonetic, and devastating esthetic problems. Complete and predictable restoration of lost interdental papillae remains one of the biggest challenges in periodontal reconstructive surgery. On reviewing the literature, publications involving surgical and nonsurgical techniques for papilla reconstruction are basically case presentations. Very little scientific data concerning long-term success and predictability of specific techniques has been published so far. Starting with facts about the anatomy and morphology of the interdental tissues, this article gives an overview of surgical and nonsurgical techniques to restore lost interproximal dental papillae.

Alveoloplasty↗

Evaluation of a new bioresorbable barrier to facilitate guided bone regeneration around exposed implant threads. An experimental study in the monkey.

The aim of this study was to evaluate the effectiveness of a new bioresorbable barrier alone or in combination with BioOss for guided bone regeneration around dental implants with exposed implant threads. Five adult Macaca fascicularis monkeys were used in this investigation. After extraction of all premolars and first molars, two endosteal oral implants were installed in each quadrant and the bony defects were randomly treated with either: 1) placement of the new bioresorbable device alone (group 1); 2) placement of the new bioresorbable barrier in combination with BioOss (group 2); 3) placement of an ePTFE barrier in combination with BioOss (group 3); or (4) control (group 4). After a period of six months the animals were killed and the histological processing was performed. There was a significant difference in the amount of new bone regeneration around the implants between the four groups (i.e. groups 1, 2, 3 and 4) (P=0.0122). There was no difference, however, between group 2 and group 3. It can be concluded that the new bioresorbable barrier in combination with BioOss appears to obtain the same results in this type of bony defects as the grafting material in combination with an ePTFE barrier.

Animals↗

Healing patterns in recession defects treated with ePTFE membranes and with free connective tissue grafts. A histologic and histometric study in the beagle dog.

This study focussed on the biologic success of 2 different procedures for root coverage. In the maxillary canines of 7 beagle dogs, buccal recessions were created and treated on one side with an ePTFE membrane (GTR-group) and on the contralateral side with a free connective tissue graft from the palate (CT-group). 2 areas served as negative controls. After 4 months of healing, histologic sections were processed and histologically analyzed. The evaluated parameters were coverage height, bone, cementum and connective tissue attachment regeneration, length of the epithelium, resorption, and ankylosis. Histologically, both GTR-group and CT-group produced more new bone, new cementum and new connective tissue attachment than the two control teeth. When histologically evaluated, the amount of new bone was more pronounced in the GTR-group than in the CT-group, however, no statistical differences in any of the evaluated parameters could be detected between the 2 procedures tested. Frequency and distribution of resorption and ankylosis were similar in the GTR-group and in the CT-group. Within the limits of this study, no differences in terms of the biologic rehabilitation between those recessions treated with ePTFE membranes and those treated with a free connective tissue graft could be found.

Animals↗

Changes in peri-implant tissues subjected to orthodontic forces and ligature breakdown in monkeys.

The aims of this investigation were to histologically evaluate in monkeys the effect of a repetitive mechanical trauma alone on the peri-implant tissues, and the effect of a repetitive mechanical trauma in combination with ligature-induced peri-implantitis on the peri-implant tissues. The study used 5 male cynomolgus monkeys. Prior to the start of the study, all premolars and the first and second molars in the mandible were extracted. After a healing period of 12 weeks, following tooth extraction, split/full thickness flaps were elevated on both sides of the mandible in order to expose the bony ridge. Four implants, of 3.75 mm in diameter and 7 mm in length, were then inserted on each side and the flaps were readapted and sutured in place. Following a healing period of 16 weeks, the second stage procedure was performed, impressions were taken, and custom-made crowns using a non-precious metal alloy were fabricated and inserted on all implants 4 weeks after abutment connection. At the same time peri-implantitis was induced on one side of the mandible by placing plaque-retentive ligatures around the implants. On the other side, an oral hygiene program consisting of thrice weekly brushing with a toothbrush and flour of pumice mixed with 2% chlorhexidine was initiated. Four months later, a repetitive mechanical trauma was initiated on implants 1 and 2 on both sides in the mandible. Consequently, a split mouth design was obtained: 1) test 1=ligature-induced peri-implantitis alone (LPNO); 2) test 2=ligature-induced peri-implantitits with a repetitive mechanical trauma (LPMT); 3) test 3=healthy peri-implant tissues with a repetitive mechanical trauma (MT); and 4) control (NO)=healthy peri-implant tissues with no repetitive mechanical trauma. Following 16 weeks of repetitive mechanical trauma the animals were sacrificed. Histologic observations and computed-assisted histometric and histomorphometric analyses were performed to determine the amount of peri-implant bone loss and the percentage of direct mineralized bone-to-implant contact around each endosseous oral implant. Histologically, all implants yielded osseointegration at the light microscopic level. There was a significant difference regarding the mean direct mineralized bone-to-implant contact length as a fraction of the total implant length between the healthy (i.e., MT and NO) and diseased sites (i.e., LPNO and LPMT) (P < 0.05). When comparing the percent of direct mineralized bone-to-implant contact for the 2 best threads of each implant and group, no significant difference (P=0.675) could be detected. Under the conditions of this study, the repetitive mechanical trauma showed no histologic effect on the peri-implant bone loss neither in healthy nor in diseased implant sites. The effects of excessive loading on osseointegration are presently not clearly understood. The key problem seems to be the determination when loading on implants exceeds the physiological range of bone adaptation which may then cause implant failure. Further research to elucidate this problem is essential.

Adaptation, Physiological↗

The effects of guided bone regeneration and grafting on implants placed into immediate extraction sockets. An experimental study in dogs.

Guided bone regeneration (gbr) for the treatment of insufficient bone volume around implants can be performed using membranes with or without grafting materials (i.e., autogenous, allogenous, xenogenous, or alloplastic grafts). A possible way to evaluate the quality of implant osseointegration is the torque necessary to remove implants from their bony housing. The aim of this study was to compare the torques necessary to remove dental implants from implant beds reconstructed with different bone substitutes and GBR or GBR alone in 6 adult mongrel dogs. All mandibular premolars were extracted and 3 extraction sockets on each side were enlarged using a trephine bur. A 13 mm titanium screw-type dental implant (3.75 mm diameter) was placed in each enlarged extraction socket so that only the apical 3 to 4 mm were engaged in bone. The 3 defects were then randomly treated with either 1) canine demineralized freeze-dried bone allograft (DFDBA) plus GBR using an expanded polytetrafluoroethylene membrane (DFDBA+GTAM); 2) bioabsorbable hydroxyapatite and GBR (HA+GTAM); or 3) GBR (GTAM alone). After 6 months, the torque to remove the implants was measured in 4 animals and analyzed using ANOVA. There were no statistically significant differences between the 3 groups (GTAM alone: 46.37+/-16.41 Ncm; HA+GTAM: 46.00+/-16.59 Ncm; DFDBA+ GTAM: 52.15+/-29.24 Ncm). In addition, the influence of early removal of barriers on the torque values was evaluated with the t-test. Comparing exposed versus retained membranes by treatment modality, the only statistically significant difference was found in the DFDBA+GTAM group. When the torque values of all implants with exposed and retrieved membranes were compared to all those with retained membranes a significant difference could be detected. Histologic sections were prepared from the 2 dogs not included in the removal torque testing. In the histometric analysis the GTAM alone group showed a mean mineralized bone-to-implant-contact of 27.1%, the DFDBA+GTAM group of 34.6%, and the HA+GTAM of 39.3%. The mineralized bone-to-implant-contact of the HA+GTAM group was significantly higher than that of the GTAM alone group. In addition, the mineralized bone-to-implant-contact was divided into an apical and coronal part using the apical seventh thread as the dividing landmark. In the apical region, there was no significant difference between the groups regarding mineralized bone-to-implant-contact. In the coronal part the mineralized bone-to-implant-contact of the GTAM alone group was significantly lower compared to the other 2 groups. Within the limits of this investigation, it can be concluded that the type of grafting material will not influence torque removal values, but that early membrane exposure and removal will negatively influence the torque measurements. The combination of GBR with a bone substitute increased the mineralized bone-to-implant contact.

Absorbable Implants↗

Guided bone regeneration around dental implants in the atrophic alveolar ridge using a bioresorbable barrier. An experimental study in the monkey.

The aim of this study was to evaluate guided bone regeneration (GBR) around dental implants placed in atrophic alveolar ridges using an experimental, nonporous bioresorbable barrier. In 8 Rhesus monkeys, the maxillary canines and lateral incisors were extracted bilaterally and the remaining alveoli were reduced to create atrophic ridges. After a healing period of 3 months, soft tissue expansion was performed using a subperiosteal tissue expander. After 1 month of tissue expansion, and IMZ implant was placed in the atrophic ridge on each side in such a way that its coronal 4 mm to 5 mm remained circumferentially exposed above the bone level. The test implants were covered with a bioresorbable barrier made of poly (D,L-lactid-co-trimethylencarbonate) in a 70/30 ratio, whereas the control implants were covered with a nonresorbable expanded polytetrafluoroethylene (e-PTFE) barrier. The e-PTFE barriers were stabilized with titanium minipins while the bioresorbable barriers were analogously fixed using bioresorbable minipins made of poly (L-lactid-co-D,L-lactid) 70/30. Clinical healing progressed uneventfully in both groups and no soft tissue dehiscences occurred. Histometric and histomorphometric analyses were performed 5 months post surgery. Both test and control implants exhibited direct bone-to-implant contact to variable extents. The mean direct mineralized bone-to-implant contact length fraction was 32% of the total implant length in the test sites and 58% in the control sites. Control sites exhibited significantly greater bone fill compared to the experimental sites (P < 0.001). Histologic observations of test specimens demonstrated a moderate inflammatory reaction related to the degradation and resorption products of the barrier. In conclusion, the nonresorbable e-PTFE GBR barrier was found to be superior to the bioresorbable barriers tested in the present investigation.

Alveolar Bone Loss↗

The effect of a calcium hydroxide paste on wound healing and osseointegration of dental implants. A pilot study in beagle dogs.

The aim of this investigation was to evaluate the effect of a new calcium hydroxide suspension (Osteoinductal) on the healing process of endosseous dental implants after placement. The material, composed of 25% calcium hydroxide, 25% Oleum pedum tauri and 50% vaselinum album, was developed with the intention to accelerate and to increase the mineralized bone to implant contact during the healing phase. Eight adult beagle dogs were used in this study. Prior to the beginning of the study the dogs had all mandibular premolars extracted. After the extraction sites had healed for 3 months, implant osteotomies were performed. On one side of the mandibular premolars extracted. After the extraction sites had healed for 3 months, implant osteotomies were performed. On one side of the mandible Osteoinductal was applied into the osteotomies before placement of the implants, whereas the other side did not receive Osteoinductal. A total of 48 implants were placed with two losses during the entire study period. Two dogs were sacrificed 1 week, 2 weeks, 4 weeks and 3 months after implant placement. The specimens were evaluated histologically and histomorphometrically. In the histological evaluation an intense inflammatory reaction towards the calcium hydroxide suspension was found leading to a destruction of the bone surrounding the implants after 1 and 2 weeks. A giant cell reaction against the test material was visible at 4 weeks. At 3 months no inflammatory and no giant cell reaction could be depicted in the test group. The mean direct bone to implant contact or inflammatory tissue to implant contact showed no differences between test and control group for 1 and 2 weeks. Although statistically not significant, there was a clinical significant difference in the mineralized bone to implant contact between test and control group for the last two timepoints (i.e. 4-week specimens: test group 2.3 +/- 0.9%, control group 26.8 +/- 11.1%; 3-month specimens: test group 10.5 +/- 12.7%, control group 60.7 +/- 13.7%). This study indicates that the use of the calcium hydroxide suspension Osteoinductal has a detrimental effect on wound healing and osseointegration of dental implants and cannot be recommended for use with dental implants.

Alveolar Process↗

Custom-made root analogue titanium implants placed into extraction sockets. An experimental study in monkeys.

The aim of this investigation was to evaluate clinically and histologically a new custom-made, root analogue titanium implant placed into extraction sockets in monkeys (Macaca fascicularis). Three adult monkeys were used in this investigation. After raising full thickness flaps on the buccal and lingual side, the upper central and lateral incisors were extracted. Each tooth root was machine copied to 1 titanium analogue using a new CAD/CAM-system. The implants were installed in the respective extraction sockets and the flaps sutured back. After 6 months of healing biopsies were taken and processed according to the cutting-grinding technique. The percentage of mineralized bone-to-implant contact was measured as a fraction of the rough implant surface using computer-assisted analysis. The main clinical problem that occurred during implant placement was the fracture of the buccal alveolar wall. The histometric evaluation showed a mean mineralized bone-to-implant contact of 41.2 +/- 20.6%. In this investigation it could be shown that implants fabricated by laser copying will osseointegrate. The presented data encourage the performance of clinical and experimental trials evaluating the new system utilizing improved second generation CAD/CAM equipment. Such studies are currently underway.

Animals↗

Maxillary sinus augmentation using different grafting materials and dental implants in monkeys. Part III. Evaluation of autogenous bone combined with porous hydroxyapatite.

The aim of this study was to evaluate clinically, histologically, and histometrically the use of autogenous bone combined with porous hydroxyapatite (Interpore 200) as a grafting material for maxillary sinus augmentation procedures. In 4 adult male rhesus monkeys (Macaca mulatta) the 1st, 2nd and 3rd maxillary molars on one side of the jaws were extracted. After a healing period of 3 months, maxillary sinus augmentation procedures were performed in each monkey, and the sinuses were grafted with autogenous bone from the monkeys' tibia mixed in a 3:1 ratio with porous hydroxyapatite. At the same time, 2 pure titanium plasma-sprayed IMZ cylinder implants were immediately placed into the augmented sinuses (i.e. simultaneous implants-loaded group). After 4 months, 2 additional similar implants were placed into the previously augmented sinuses (i.e. delayed implants-loaded group). Four months later, the abutment connection was performed and all 4 implants were loaded with a gold-alloy bridge for 6 months (i.e. until sacrifice of the animals). The contralateral side of each monkey received similar treatment with the exception that the extractions were performed 7 months after those in the opposite side and that the implants were not loaded. Thus, 2 additional study groups (i.e. simultaneous implants unloaded group and delayed implants unloaded group) were obtained. Clinically, all loaded implants were stable at the day of sacrifice. Histologically, the grafted sinuses exhibited a significant amount of new bone formation. The porous hydroxyapatite granules appeared integrated with the newly formed bone. Histometric analyses revealed that delayed implant placement resulted in a greater amount of direct mineralized bone-to-implant contact in the augmented area than the simultaneous implant placement. Furthermore, the percentage of direct mineralized bone-to-implant contact was far more significant in the residual bone than in the augmented area. It was concluded that the autogenous bone/porous hydroxyapatite graft combination enhanced bone formation and mineralized bone-to-implant contact in the augmented sinuses and that the delayed implant placement may be favorable for sinus augmentation procedures.

Animals↗

Maxillary sinus augmentation using different grafting materials and dental implants in monkeys. Part I. Evaluation of anorganic bovine-derived bone matrix.

The aim of this study was to evaluate clinically, histologically and histometrically the use of anorganic bovine bone matrix (i.e. Bio-oss) as a grafting material for maxillary sinus augmentation procedures. In 4 adult male rhesus monkeys (i.e. Macaca mulatta) the 1st, 2nd and 3rd maxillary molars on one side of the jaws were extracted. The remaining bone between the alveolar crest and the bottom of the sinus was then reduced to 3-4 mm. After 3 months, maxillary sinus augmentation procedures were performed on one side of the jaws in each monkey and the sinuses were grafted with the bovine bone matrix. At that time, 2 IMZ pure titanium plasma coated implants were immediately placed into the augmented sinuses (i.e. simultaneous implants-loaded group). After 4 months, 2 additional similar implants were placed into these previously augmented sinuses (i.e. delayed implants-loaded group). Four months later, the abutment connection was performed and all 4 implants were loaded with a gold-alloy bridge for 6 months (i.e. until sacrifice of the animals). The contralateral side of each monkey received the same treatment with the exception that the extractions were performed 7 months after those in the opposite side and that the implants in this side were not loaded. Thus, 2 additional study groups (i.e. simultaneous implants-unloaded group and delayed implants-unloaded group) were obtained. Clinically, all loaded implants were stable at the day of sacrifice. Histologically, the grafted sinuses exhibited significant bone formation with integration of the bovine bone matrix particles to the new bone. Direct mineralized bone-to-implant contact was greater for the delayed implant placement groups than for the implants installed simultaneously with the sinus augmentation. Furthermore, the percentage of direct mineralized bone-to-implant contact was greater in the residual bone than in the augmented area. It was concluded that the anorganic bovine bone matrix facilitated bone formation and implant osseointegration in the augmented sinuses and that the delayed implant placement in combination with the sinus augmentation procedure seemed to be preferable.

Alveolar Process↗

Maxillary sinus augmentation using different grafting materials and osseointegrated dental implants in monkeys. Part II. Evaluation of porous hydroxyapatite as a grafting material.

The aim of this study was to evaluate clinically, histologically and histometrically the use of porous hydroxyapatite (i.e. Interpore-200) as a bone grafting material for maxillary sinus augmentation procedures. In 4 adult male rhesus monkeys (i.e. Macaca mulatta) the 1st, 2nd and 3rd maxillary molars on one side of the jaws were extracted and the remaining bone between the alveolar crest and the bottom of the sinus was reduced to 3-4 mm. After 3 months, maxillary sinus augmentation procedures were performed on one side of the jaws in each monkey, and the sinuses grafted with the porous hydroxyapatite. Two IMZ titanium plasma-sprayed cylinder implants were then immediately placed into the augmented sinus (i.e. simultaneous implants-loaded group). After 4 months, 2 additional similar implants were placed into the previously augmented sinuses (i.e. delayed implants-loaded group). Four months later, the abutment connection was performed and all 4 implants were loaded with a gold-alloy bridge for 6 months (i.e. until sacrifice). The contralateral side of each monkey received the same treatment with the exception that the extractions were performed 7 months after those in the opposite side and that the implants in this side were not loaded. Thus, 2 additional study groups (i.e. simultaneous implants-unloaded group and delayed implants-unloaded group) were obtained. Clinically, all loaded implants were stable at the day of sacrifice. Histologic analysis demonstrated a significant amount of new bone formation in the augmented sinuses. Porous hydroxyapatite graft particles appeared to be integrated to the new bone. The percentage of direct mineralized bone-to-implant contact in the augmented area was greater on the delayed-placed implants than on the simultaneously-placed implants. Also, the percentage of direct mineralized bone-to-implant contact was greater in the residual bone than in the augmented area. It was concluded that this porous hydroxyapatite bone graft enhanced bone formation and bone-to-implant contact in the augmented sinuses and that the delayed implant placement in combination with the sinus augmentation procedure appears to result in a higher percentage of direct mineralized bone-to-implant contact.

Alveolar Process↗

Maxillary sinus augmentation using different grafting materials and dental implants in monkeys. Part IV. Evaluation of hydroxyapatite-coated implants.

The aim of this study was to evaluate clinically, histologically and histometrically the use of hydroxyapatite-coated dental implants in conjunction with maxillary sinus augmentation procedures. In 4 adult male Rhesus monkeys (Macaca mulatta) the 3 maxillary molars on 1 side of the jaws were extracted and the remaining bone between the alveolar crest and the floor of the sinus was reduced to 3-4 mm. After 3 months, maxillary sinus augmentation procedures were performed in each monkey and the sinuses were grafted with a porous hydroxyapatite bone graft (Interpore-200). At the same time, 2 hydroxyapatite-coated cylinder implants (IMZ) were immediately placed into the augmented sinuses (i.e. simultaneous-implants-loaded group). Four months later, 2 additional similar implants were placed into the previously augmented sinuses (i.e. delayed-implants-loaded group). After 4 months, the abutment connection was performed and all 4 implants were loaded with a gold-alloy bridge for 6 months (i.e. until sacrifice of the animals). The contralateral side of each monkey received the same treatment with the exception that removal of the maxillary molars was performed 7 months after those in the opposite side, and that the implants in this side were not loaded. Thus, 2 additional study groups (i.e. simultaneous-implants-unloaded group and delayed-implants-unloaded group) were obtained. Clinically, all loaded and unloaded implants were stable the day of sacrifice. Histologically, the grafted sinuses exhibited a significant amount of new bone formation with integration of the porous hydroxyapatite graft particles and hydroxyapatite-coat of the dental implants to the new bone. Histometric analysis indicated that on the loaded side the implants placed simultaneously with the sinus lift procedure exhibited greater direct mineralized bone-to-implant contact than the delayed placed implants. In addition, the percentage of direct mineralized bone-to-implant contact was significantly greater in the residual bone in comparison to the augmented area in all groups. Loading of the implants exhibited a positive effect on the percentage of direct mineralized bone-to-implant contact in the augmented area. It could be concluded that hydroxyapatite-coated implants may be of benefit when used in conjunction with sinus augmentation procedures.

Alveolar Process↗