PubMed Health⌕ Search

Biomedical subjects

M B Hofman

Publications and source records attributed to M B Hofman.

At least 19 recordsLinked to original sources

Quantitative differentiation between BOLD models in fMRI.

Several gradient-echo fMRI blood oxygenation level-dependent (BOLD) effects are described in the literature: extravascular spin dephasing around capillaries and veins, intravascular phase changes, and transverse relaxation changes of blood. This work considers a series of tissue compartmentalized models incorporating each of these effects, and tries to determine the model which is most consistent with the data. To isolate the different tissue contributions, a series of multi-echo inversion recovery (IR) fMRI scans were performed. Visual stimulation experiments were performed at 1.5 T, one interleaved six-echo and two IR six-echo EPI scans (the latter to suppress gray matter (GM) and cerebrospinal fluid (CSF)). The tissue and vascular composition of activated areas was analyzed using independent spin-echo IR MRI experiments and MR venography, respectively. This information was used to fit the multi-echo fMRI data to the BOLD models. The activated areas almost always included a venous vessel visible on the venogram and consisted of GM and CSF. The fMRI signal changes were best described by extravascular dephasing effects in both GM and CSF around a venous vessel, in combination with intravascular effects. The role of spin dephasing around capillaries in GM appears to be insignificant. Magn Reson Med 45:233-246, 2001.

Body Fluid Compartments↗

Simultaneous noninvasive measurement of blood flow in the great cardiac vein and left anterior descending artery.

Magnetic resonance (MR) flow mapping can be used to quantify flow velocity and volume flow in the coronary vessels noninvasively. The close anatomic relationship of the left anterior descending artery (LAD) with the great cardiac vein (GCV) allows imaging of both in one view. We examined the feasibility to discriminate between these two vessels based on the flow pattern and to measure the flow quantitatively. Eleven individuals with a normal LAD and 8 patients with a diseased LAD underwent MR imaging. From MR angiograms using connectivity to the aortic root, differentiation between the LAD and GCV was obtained. Perpendicular to both vessels, phase-contrast velocity mapping was performed to measure phasic and mean volume flow. After correction for cardiac motion of the vessel, GCV flow was found to be mainly systolic and pointing in the inverse direction as the predominantly diastolic flow in the LAD. These criteria appeared valid in all subjects, even in cases of highly stenotic arteries. The volume flow measurements corrected for body surface area were 31+/-15 ml/min/m2 in the normal LAD (n = 11) and 21+/-10 ml/min/m2 in the diseased LAD (n = 7). The volume flow measurements in the GCV corrected for body surface area were 23+/-19 ml/min/m2 in the normal vessels and 19+/-16 ml/min/m2 in the diseased vessels. In the patient with an occluded LAD and collaterals, the volume flow in the GCV was 7 ml/min/m2. MR is a unique tool for noninvasive simultaneous measurement of the flow pattern and volume flow in the GCV and the LAD, showing a clear distinction between arterial and venous flow.

Adult↗

High-resolution segmented EPI in a motor task fMRI study.

A high-resolution gradient echo, multi-slice segmented echo planar imaging method was used for functional MRI (fMRI) using a motor task at 1.5 Tesla. Functional images with an in-plane resolution of 1 mm and slice thickness of 4 mm were obtained with good white-gray matter contrast. The multi-shot approach, combined with a short total readout period of 82 ms, limits blurring effects for short T(2)(*) tissues (such as gray matter), assuring truly high-resolution images. In all subjects, motor functions were clearly depicted in the contralateral central sulcus over several slices and sometimes activation was detected in the supplementary motor area and/or ipsilateral central sulcus. The average signal change of 11+/-3% was much higher than in standard low-resolution fMRI EPI experiments, as a result of larger relative blood fractions.

Adult↗

Sub-millimeter fMRI at 1.5 Tesla: correlation of high resolution with low resolution measurements.

Functional magnetic resonance imaging of the visual cortex with an in-plane resolution of 0.4 x 0.4 mm2 was performed using a simple visual stimulus resulting in clear maps of activation. A collapsing filter was used to compare these high-resolution images with low-resolution images collected during the same session. A good correspondence between the high- and low-resolution functional maps was found with respect to the center of localization of activation. However, only 20% of the size of activated areas in the low-resolution experiment was observed at high resolution, which was partly caused by the difference in signal-to-noise ratio. The high-resolution images produce signal changes much higher than the low-resolution images due to reduced partial volume effects. Additionally, the high-resolution functional maps were compared with detailed anatomical and venous information. The activated areas were predominantly observed at venous vessels within the sulci with a diameter on the order of the pixel size.

Adult↗

Morphologic and functional evaluation of coronary artery bypass conduits.

There is clear evidence in the literature that conventional spin-echo and gradient-echo magnetic resonance imaging (MRI) is capable of assessing patency of coronary artery vein grafts. With more recently introduced breath-hold two-dimensional (2D) and contrast-enhanced 3D techniques, the predictive accuracy has further improved, with sensitivities and specificities in the 90% range. Limitations arise with regard to assessing obstructive disease and evaluating distal segments of sequential grafts, due to insufficient spatial resolution, low signal-to-noise ratio, and cardiac motion. Imaging of arterial grafts is complicated by the metallic clip artifacts. Adding information on graft flow patterns and flow reserve using velocity-encoded cine MRI may help to reduce some of the problems. Clinically, these functional measurements may become of use in non-invasive monitoring of gradually increasing graft narrowing. However, apart from a few exceptions, most patients undergo evaluation of their grafts because they are considered for a re-intervention by angioplasty or coronary artery bypass graft surgery. In these cases information on the status of the native coronary arteries is required. A broader clinical use of MRI in the evaluation of patients with coronary artery bypass grafts may therefore only be expected with further improvement in MR techniques for coronary angiography. J. Magn. Reson. Imaging 1999;10:734-740.

Blood Vessel Prosthesis↗

Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulse.

The ability of a blood pool contrast agent to enhance MR coronary angiography was defined. The proximal coronary vessels of pigs were imaged before and after administration of Gd-DTPA bound covalently to bovine serum albumin (0.2 mmol/ kg). The contrast agent resulted in a reduction of the blood T1 value to 33+/-5 msec, as determined in vivo with a Look-Locker technique. Both 2D and 3D imaging techniques were performed. An inversion pulse suppressed the signal of nonblood tissue postcontrast. After contrast agent administration, in the 3D data set the signal-to-noise ratio (SNR) of blood and contrast-to-noise ratio (CNR) of blood to myocardium were improved by factors of 2.0+/-0.2 and 15+/-8, respectively (P < 0.05). Postcontrast, the 3D acquisition was superior to the 2D technique in terms of spatial resolution, SNR of blood, and CNR of blood to myocardium. The high contrast of the 3D data set allowed for direct and rapid display of coronary arteries using a "closest vessel projection."

Animals↗

Clinical utility of two-dimensional magnetic resonance angiography in detecting coronary artery disease.

AIMS: The accuracy of magnetic resonance angiography in detecting proximal coronary artery stenoses is unclear. We postulated that fast magnetic resonance angiography is capable of (1) imaging proximal coronary arteries, and (2) detecting stenoses of > or = 50% of their luminal diameter. METHODS AND RESULTS: Thirty-five patients, referred for analysis of angina pectoris, underwent both conventional angiography and magnetic resonance angiography of coronary arteries. A fast k-space segmented gradient-echo technique was used during breath-holds. Two observers, blinded to the results of conventional angiography, independently analysed the magnetic resonance studies for (1) length of visualized segments, and (2) presence of signal voids indicative of stenoses. From 140 proximal arteries, 15 (11%) were excluded because of incomplete imaging or degraded image quality. Mean length of the visualized segments was 9 +/- 4 mm for the left main, 62 +/- 16 mm for the left anterior descending, 21 +/- 9 mm for the left circumflex and 89 +/- 32 mm for the right coronary artery. Sensitivity for detecting > or = 50% luminal diameter stenoses was 0.00 for the left circumflex, 0.53 for the left anterior descending coronary artery, 0.71 for the RCA and 1.00 for the left main artery. Specificity varied from 0.73 for the left anterior descending coronary artery to 0.96 for the left circumflex. Inter-observer agreement was 0.90. CONCLUSION: Thus, segmented magnetic resonance angiography is capable of non-invasive imaging of proximal coronary anatomy. Its good accuracy in detecting left main coronary artery disease, intermediate accuracy in detecting right coronary artery and left anterior descending coronary artery stenoses, and low accuracy in detecting left circumflex lesions fit within a range of sensitivities and specificities found by others. Further technical advances are necessary to make the technique clinically robust.

Coronary Angiography↗

Transesophageal cardiac pacing during magnetic resonance imaging: feasibility and safety considerations.

The feasibility and safety of transesophageal cardiac pacing during clinical MRI at 1.5 Tesla is considered. An MRI compatible pace catheter was developed. In vitro testing showed a normal performance of the pulse generator, image artifacts that extended less than 11 mm from the catheter, and a less than 5% increase in noise. Cardiac stimulation induced by MRI was not observed and, theoretically, is not expected. Potentially, tissue around the catheter tip may become heated. This heating (delta tau) was monitored. Eight dogs were exposed to MRI during pacing. For low RF radiation exposure, a time-averaged squared B1 field below 0.08 p tau 2 (SAR < 0.03 W/kg), delta tau was below 1 degree C. For high RF radiation exposure, but at normal RF radiation specific absorption rate (0.4 W/kg) delta tau was 5 degrees C. Thus, transesophageal atrial pacing during MRI at low RF exposure seems to be possible to perform cardiac stress studies or to correct unstable heart rates.

Animals↗

Assessment of flow in the right human coronary artery by magnetic resonance phase contrast velocity measurement: effects of cardiac and respiratory motion.

Flow in the human right coronary artery was determined using magnetic resonance phase contrast velocity quantification. Two methods were applied to reduce respiratory motion: Imaging during breath holding, which is fast, and retrospective respiratory gating, which has a high temporal resolution (32 ms) in the cardiac cycle. Vessel cross-sectional area, through-plane velocity, and volume flow were determined in six healthy subjects. In-plane vessel displacement during the cardiac cycle, caused by cardiac contraction, was about 2-4 mm within a time frame of 32 ms in systole and early diastole. The motion resulted in blurring of images obtained during breath holding caused by the large acquisition time window (126 ms) within the cardiac cycle. Therefore, only with a high temporal resolution correct velocity images over the entire cardiac cycle could be obtained. The time- and cross-sectionally averaged velocity was 7 +/- 2 cm/s, and the volume flow was 30 +/- 10 ml/min.

Adult↗

Quantification of coronary artery bypass graft flow by magnetic resonance phase velocity mapping.

OBJECTIVES: Determination of the true coronary artery bypass graft function requires quantification of the flow rate within the graft. The purpose of the present study was to assess the feasibility of characterizing and quantifying graft flow by magnetic resonance phase velocity mapping. MATERIALS AND METHODS: Twenty-seven patients with 41 angiographically patent coronary artery bypass grafts underwent electrocardiographically gated magnetic resonance phase velocity mapping. Imaging was performed at 0.6 Tesla using a surface coil. Velocity maps of the bypass grafts were obtained throughout the cardiac cycle with a temporal resolution of 50 ms and a spatial resolution of 1.9 x 1.2 x 5 mm3, allowing calculation of phasic and mean graft flow. RESULTS: Adequate flow measurements were obtained in 84% (41 out of 49) of the grafts. Coronary artery bypass graft flow was characterized by a biphasic pattern with a first peak during systole and a second peak during diastole. Average maximum systolic and diastolic velocities over the cross-section of the grafts were 14 +/- 8 cm/s and 15 +/- 9 cm/s, respectively. Mean coronary artery bypass graft cross-sectional area was 0.28 +/- 0.13 cm2. Mean volume flow was 87 +/- 59 ml/min. CONCLUSION: Flow in coronary artery bypass grafts can be characterized and measured noninvasively by magnetic resonance phase velocity mapping.

Blood Flow Velocity↗

Three-dimensional respiratory-gated MR angiography of coronary arteries: comparison with conventional coronary angiography.

OBJECTIVE: MR coronary angiography is most often performed using two-dimensional techniques. Although three-dimensional (3D) acquisitions do have important advantages, they take too long for a single breath-hold and are thus susceptible to respiratory motion artifacts. The purpose of this study was to investigate the accuracy of a unique respiratory-gated 3D MR angiographic technique in identifying the proximal coronary arteries in patients suspected of having coronary artery disease. In addition, we investigated the capability of this technique to detect proximal stenoses. SUBJECTS AND METHODS: We performed a prospective blinded study in 20 patients who were referred for conventional coronary angiography. A cardiac-gated 3D gradient-echo sequence with fat suppression was used. Retrospective respiratory gating was performed using navigator echoes of the diaphragm position. Using multiplanar reformatting, two independent readers blindly analyzed the data sets for visualization of major coronary arteries, lengths of imaged segments, and detection of significant stenoses (> 50% occlusion of the luminal diameter by conventional angiography). RESULTS: Seventy-seven of 80 (96%) coronary arteries were positively identified. In one patient, an anomalous coronary anatomy was readily identified and confirmed by conventional angiography. The average lengths of the imaged segments of the right, left main, left anterior descending, and left circumflex coronary arteries were 58 +/- 13 mm, 9 +/- 5 mm, 59 +/- 16 mm, and 24 +/- 10 mm, respectively. Overall sensitivity for the detection of stenoses was low (38%), with a specificity of 95%. Interobserver agreement was 0.92, with a kappa value of 0.65. CONCLUSION: Respiratory-gated 3D MR angiography allows accurate identification of proximal coronary arteries and may be valuable for 3D imaging of coronary anomalies. Further technical improvements are required to enhance the value of the technique in detecting stenoses.

Adult↗

Magnetic resonance angiography of anomalous coronary arteries. A new gold standard for delineating the proximal course?

BACKGROUND: The clinical significance of anomalously originating coronary arteries depends on their proximal course. Diagnosis of this course by conventional x-ray coronary angiography alone may be equivocal. We postulated that with fast magnetic resonance (MR) angiography, accurate detection of anomalous coronary arteries and unambiguous delineation of their proximal course is feasible. METHODS AND RESULTS: In a selected group of 38 patients, 19 of them having an anomalously originating coronary artery, a fast MR angiographic technique was used to study the proximal coronary anatomy. Blinded analysis of randomly ordered MR studies was performed independently by two observers. Both origin and proximal course of the coronary arteries were defined. Two cardiologists reviewed all x-ray coronary angiograms. After the separate analyses, a final consensus result was defined for each patient. In 37 patients, successful MR coronary angiography could be performed. Interobserver agreement for determining both origin and proximal course was 100%. An x-ray coronary angiogram was available in 36 patients. In 3 patients (all with an anomalous left main coronary artery originating from the right aortic sinus), there was disagreement about the proximal course between the results of MR and x-ray coronary angiography. Review of these cases demonstrated that MR angiography had unambiguously visualized the proximal coronary artery course, whereas the results of x-ray angiography had been equivocal. Thus, sensitivity and specificity for detecting anomalous coronary arteries and delineating their proximal course were 100%. CONCLUSIONS: These data suggest that fast MR angiography is highly accurate in determining the origin and delineating the proximal course of anomalous coronary arteries, even in those cases in which x-ray coronary angiographic diagnosis is difficult or even erroneous.

Coronary Angiography↗

Motion induced phase shifts in MR: acceleration effects in quantitative flow measurements--a reconsideration.

Magnetic resonance phase difference techniques are commonly used to study flow velocities in the human body. Acceleration is often present, either in the form of pulsatile flow, or in the form of convective acceleration. Questions have arisen about the exact time point at which the velocity is encoded, and also about the sensitivity to (convective) acceleration and higher order motion derivatives. It has become common practice to interpret the net phase shifts measured with a phase difference velocity technique as being the velocity at a certain (Taylor) expansion time point, chosen somewhere between the RF excitation and the echo readout. However, phase shifts are developed over the duration of the encoding magnetic field gradient wave form, and should therefore be interpreted as a more or less time-averaged velocity. It will be shown that the phase shift as measured with a phase difference velocity technique represents the velocity at the "gravity" center of the encoding bipolar gradient (difference) function, without acceleration contribution. Any attempt to interpret the measured phase shift in terms of velocity on any other time point than the gradient gravity point will automatically introduce acceleration sensitivity.

Acceleration↗

In vivo validation of magnetic resonance blood volume flow measurements with limited spatial resolution in small vessels.

The accuracy of magnetic resonance phase contrast volume flow measurements in small blood vessels is expected to be smaller than in large vessels, because of partial volume effects at the vessel boundary. Accuracy was validated in the dog femoral artery, diameter 3.5 +/- 0.7 mm, using an ultrasonic transit-time flowmeter (TT). The number of pixels per vessel diameter (ND) ranged from 1.6 to 4.8. The vessel cross-section was determined using a threshold in the magnitude image. Between the two methods the correlation coefficient was 0.95 (range 10-200 ml/min). The proportional difference (PD), (QTT-QMR)/1/2(QTT+QMR), was 0.8%, showing no systematic difference between the methods. The PDs standard deviation was 27%, and 19% for flow rates above 30 ml/min. Only a significant decrease of the PDs variance was found at the highest ND values, suggesting other sources of error than partial volume effects. It is concluded that with an ND value of about 3, accurate blood volume flow rates can be determined.

Animals↗

Semiquantitation of regional myocardial blood flow in normal human subjects by first-pass magnetic resonance imaging.

The purpose of this study was to investigate the feasibility of first-pass MR imaging for measurement of regional myocardial blood flow in human beings. The first pass of the contrast agent Gd-DTPA through the myocardium was imaged in 12 normal volunteers with an ECG-gated Turbo-Flash sequence. The MTT of the contrast agent through the myocardium after a bolus injection was derived from curves of SI versus time. The bolus was injected through an intravenous catheter, which was advanced to the central venous position (preferably the right atrium). To investigate myocardial input function, different bolus concentrations and catheter positions were compared. It is concluded that first-pass MR imaging is feasible in human subjects when a central injection of 0.03 mmol/kg of Gd-DTPA is applied. MTT values were similar throughout the myocardium of normal subjects at rest, reflecting normal perfusion. Absolute values of MTT were related to the myocardial input.

Adult↗

Protocol for two-dimensional magnetic resonance coronary angiography studied in three-dimensional magnetic resonance data sets.

The purpose of this study was to develop a standardized method of 2D MRA of the proximal 50 mm of the major epicardial coronary arteries. Therefore the efficacy of fixed imaging planes (transverse, coronal, sagittal, 30-degree RAO equivalent, and 60-degree LAO equivalent) in imaging coronary arteries was compared to that of oblique planes defined by the operator on a previously obtained image. 3D data sets obtained by a respiratory-gated 3D MRA method in eight patients with a mean age of 57 years were studied by multiplanar reformatting. Efficacy of planes was expressed as an IOE. Fixed transverse imaging planes proved to be equally efficacious as operator-defined planes in imaging the left main (IOE 2.2 +/- 1.0 vs 2.2 +/- 0.9, p = NS) and LAD (IOE 6.0 +/- 1.9 vs 8.2 +/- 2.0, p = NS). Operator-defined planes were superior to fixed imaging planes in imaging the RCA (IOE 6.3 +/- 1.2 vs 3.5 +/- 1.2, p < 0.001) and the LCx (IOE 6.2 +/- 2.3 vs 4.8 < 2.3, p < 0.05). On the basis of these results, a standardized 2D MRA protocol for the proximal coronary arteries was proposed. Pitfalls in interpretation of coronary MRA images were discussed.

Aged↗

Nontriggered magnetic resonance velocity measurement of the time-average of pulsatile velocity.

The feasibility of the determination of the time-average of pulsatile velocity obtained via a nontriggered magnetic resonance (MR) acquisition is studied. The advantage of this method, in comparison with a triggered acquisition, is a considerable reduction (approximately 15x) in acquisition time. However, pulsatility causes image artifacts, known as ghosts, and the Fourier transform technique required for the imaging procedure accomplishes time-averaging of the complex MR signal. Both effects can result in errors in the velocity determined. Calculations show that these errors depend on the velocity time function and the acquisition parameters. In vivo comparison of triggered and nontriggered MR velocity measurements in the femoral artery of volunteers (n = 7) shows larger statistical and systematic errors in the latter, which depend on the excitation angle. Therefore, this nontriggered average velocity measurement is only useful as a fast and rough estimation of the time-averaged velocity.

Blood Flow Velocity↗