Oxygen concentrators: a primary oxygen supply source.

PURPOSE: Efforts to harmonize the standards of the CSA and the ISO, as they relate to compressed medical gas supply and piping, prompted us to review ten years experience with oxygen concentrators (OCs) in Canada used as a primary hospital oxygen supply. The goals of this study were; 1) To document the number of Canadian OC Hospital sites, 2) to define what impact these units have had on medical practice and patient care, and 3) to explore trends in oxygen costing and utilization at the study sites. METHODS: Following a four part mail survey and telephone follow up, site surveys were conducted for all hospitals utilizing an OC. Installation and service records, operating costs, amortization detail, leasing records as well as patient safety were all detailed. RESULTS: Forty eight of 52 Canadian hospitals utilizing an OC participated. Clinical activity at the surveyed sites of 1996 included 30,642 surgical operations, 9,415 intensive care bed days and 364,529 emergency room visits. The cumulative survey represents 1,026,819 hr of OC operation. During a 24 hr day, OCs operate 55 +/- 3% of the time. Financial analysis was validated at 43 of the 48 hospital sites. During the study the unit cost of oxygen was reduced by 62% (P <.0001). An annual increase in oxygen consumption of 11.5 +/- 2% was documented (P <.0001). No patient care critical incidents related to OCs were reported. CONCLUSION: An OC installation which is CAN/CSA Z305.6-M92 compliant provides a safe, reliable, cost efficient primary hospital source of oxygen.

Anesthesiology↗

Epidemic of "shocks" in telephone operators: lessons for the medical community.

In January 1986 two brief power failures occurring within an hour of each other affected the operation of visual display terminals in a section of the Manitoba Telephone System. After the power failures three operators reported an alarming tingling sensation in their arms and one side of their body, which they called "shocks". Other operators then began to report incidents of numbness and tingling in their limbs, face or head as well as other, diffuse symptoms. During the next 2 weeks 92 such incidents were reported by 55 operators. The media carried alarming headlines, and medical practitioners perpetuated the label of "electric shock". Despite extensive investigation, which revealed no electrical fault, the section was closed by the regulatory authority, and an independent medical panel was convened to review the findings. The panel concluded that there was no immediate hazard to life or health and recommended continued workplace assessment and follow-up of affected operators; however, because the panel lacked electrical engineering expertise, uncertainty persisted as to the cause of the events. The reports of incidents persisted, peaking in association with continued rumours of diagnoses of "nerve damage". In the fall of 1987 a multidisciplinary committee ruled out as causative factors all known hazards other than electrostatic shock and occupational stress. This costly and lengthy investigation underlines the danger in regarding collective stress reaction as a diagnosis of exclusion. It highlights the need to scrutinize objective evidence before validating potentially unfounded concerns and underlines the desirability of considering the psychosocial effects of technology and regimented tasks.

Disease Outbreaks↗

A simplified method for determining the P50 of blood.

A method to determine the P50 of whole blood is described using a modified American Optical reflectance oximeter, pump, and membrane tonometer, together with PO2, PCO2, and pH measurements in a standard blood gas machine. Determinations of P50 were made in 66 patients and normal subjects and in two situations where P50 was very low and very high. The results were compared to oxygen saturations calculated from measured oxygen content. The directly determined oxygen saturation agreed with the assumed saturation of 50 per cent in the oximeter within 0.5 per cent. The apparatus appears to be a simple and relatively inexpensive method to obtain P50 as long as blood carboxyhemoglobin or methemoglobin contents are not elevated.

Carbon Dioxide↗

User views on standards for defibrillators.

User views on the need for defibrillator standards were surveyed as part of a multifaceted study of defibrillator use in Canadian hospitals. The majority of users favor standardization of performance, labeling, and use characteristics. They also prefer that all defibrillators incorporate cardioversion capability. Most users prefer that the defibrillator automatically switch to the emergency mode after delivery of a cardioversion shock, but almost one half of the physicians preferred the unit to remain in the synchronized mode as set. Most users are in favor of all equipment operating in the same fashion, but paramedics are not. Only a minority believes that cardioversion features are a cause of confusion, yet conversations with biomedical engineers indicate that this confusion is a common problem among the users. Virtually all users prefer that necessary standards for safety and efficacy should be mandatory for both manufacturers and hospitals.

Attitude of Health Personnel↗

Cardiac electrodes and safe voltage limits.

The 5-mV safe voltage limit that has been proposed for hospital safety codes is shown to be based on incorrect assumptions. The actual voltage threshold for 60-Hz current is of the order of 100 mV or greater, because of the effects of electrode interface impedance and cell membrane characteristics. AK value of 50 mV is proposed as the safe voltage limit for 60 Hz current for the purposes of safety standards. The medical community is requested to consider this value.