Precision branching ratio measurement for the superallowed beta+ emitter 62Ga and isospin-symmetry-breaking corrections in A>or=62 nuclei.

A high-precision branching ratio measurement for the superallowed beta+ decay of 62Ga was performed at the Isotope Separator and Accelerator radioactive ion beam facility. Nineteen gamma rays emitted following beta+ decay of 62Ga were identified, establishing the dominant superallowed branching ratio to be (99.861+/-0.011)%. Combined with recent half-life and Q-value measurements, this branching ratio yields a superallowed ft value of 3075.6+/-1.4 s for 62Ga decay. These results demonstrate the feasibility of high-precision superallowed branching ratio measurements in the A>or=62 mass region and provide the first stringent tests of the large isospin-symmetry-breaking effects predicted for these decays.

Journal Article↗

Evidence for nontermination of rotational bands in 74Kr.

Three rotational bands in 74Kr were studied up to (in one case one transition short of) the maximum spin I(max) of their respective single-particle configurations. Their lifetimes have been determined using the Doppler-shift attenuation method. The deduced transition quadrupole moments reveal a modest decrease, but far from a complete loss of collectivity at the maximum spin I(max). This feature, together with the results of mean field calculations, indicates that the observed bands do not terminate at I = I(max).

Journal Article↗

Regional activation in the rat brain during visceral stimulation detected by c-fos expression and fMRI.

AIM: The aim of the study was to determine and compare the areas of brain activated in response to colorectal distention (CRD) using functional magnetic resonance imaging (fMRI) and c-fos protein expression. METHODS: For fMRI study (3.0 T magnet), anaesthetized rats underwent phasic CRD, synchronized with fMRI acquisition. Stimulation consisted of eight cycles of balloon deflation (90 s) and inflation (30 s), at 40, 60 or 80 mmHg of pressure. For c-fos study two sets of experiments were performed on anaesthetized rats: comparing (A) brain activation in rats with the inserted colorectal balloon (n = 5), to the rats without the balloon (n = 5); and (B) rats with inserted balloon (n = 10), to the rats with inserted and distended balloon (n = 10). The pressure of 80 mmHg was applied for 2 h of 30 s inflation and 90 s deflation, alternating cycles. RESULTS: Functional MRI revealed significant activation in the amygdala, hypothalamus, thalamus, cerebellum and hippocampus. Significant increase in c-fos expression was observed in amygdala and thalamus in the first set of experiments, and hypothalamus and parabrachial nuclei in the second. CONCLUSION: The two methods are not interchangeable but appeared to be complementary: fMRI was more sensitive, whereas c-fos had much greater resolution.

Animals↗

1H magnetic resonance spectroscopy of nanomelic chicken cartilage: effect of aggrecan depletion on cartilage T2.

OBJECTIVE: To determine the effect of proteoglycan depletion on cartilage proton magnetic resonance (MR) spectroscopy T2 using nanomelic chicken cartilage, a genetic mutant that completely lacks aggrecan. DESIGN: Proton MR spectroscopic T2 measurements of normal embryonic and nanomelic femoral epiphyseal cartilage were obtained using a 96-echo pulse sequence with inter-echo delay times increased logarithmically over the TE period of 60 micros to 1.7 s. The relative intensity and distribution of cartilage T2 components were determined by fitting signal decay curves to a multi-exponential function. The number of T2 components in the signal decay curves was determined by the degree of freedom limited r2 of the fit. RESULTS: For normal fetal chicken cartilage, 97.6 +/- 0.2% (mean +/- 95% confidence interval) of the total signal comprises a long T2 component (179.1 +/- 1.3 ms) with a relatively small short T2 component (0.5 +/- 0.4 ms). The T2 distribution for nanomelic cartilage is more heterogeneous with four components identified: two short T2 components (0.5 +/- 0.02 and 7.3 +/- 0.6 ms), a large intermediate component (56.4 +/- 5.6 ms), and a broadly distributed long component (137.5 +/- 16.6 ms). In nanomelic cartilage there is greater heterogeneity of cartilage T2 indicating greater variation in water proton mobility and exchange of water with the extracellular matrix. CONCLUSION: Absence of aggrecan in the extracellular cartilage matrix produces greater heterogeneity in cartilage T2, but will not increase T2 as has been previously reported with degenerative change of the collagen matrix.

Aggrecans↗

Removal of local field gradient artefacts in BOLD contrast imaging of head and neck tumours.

Monitoring of oxygenation in tumours is an important issue in predicting the success of anti-cancer treatments such as radiotherapy. Gradient echo (GE) imaging sequences can be used for monitoring changes in tumour blood flow and oxygenation. However, the application of this method in head and neck tumours is hampered by significant artefacts and losses of the MR signal near air-tissue interfaces. We investigated the usefulness of a gradient-echo slice excitation profile (GESEPI) sequence that should keep the oxygen contrast while recovering the signal loss caused by susceptibility artefacts. A tumour model was implanted in the neck and in the leg of mice. MR imaging was performed at 4.7 T. GE and GESEPI sequences were used for monitoring the blood oxygen level dependent (BOLD) contrast after carbogen breathing. The pO2 was also monitored in tumours using an OxyLite probe (Oxford Optronics). Using the tumours implanted in the leg, we found that the variations of signal intensity after carbogen breathing were similarin both sequences. In the tumour implanted in the neck, it was possible, using GESEPI sequences, to recover the signal loss caused by susceptibility artefacts and to monitor the effect of carbogen-induced changes in the tumour.

Animals↗

Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz.

Calculations and experiments were used to examine the B(1) field behavior and signal intensity distribution in a 16-cm diameter spherical phantom excited by a 10-cm diameter surface coil at 300 MHz. In this simple system at this high frequency very complex RF field behavior exists, resulting in different excitation and reception distributions. Included in this work is a straightforward demonstration that coil receptivity is proportional to the magnitude of the circularly polarized component of the B(1) field that rotates in the direction opposite to that of nuclear precession. It is clearly apparent that even in very simple systems in head-sized samples at this frequency it is important to consider the separate excitation and reception distributions in order to understand the signal intensity distribution.

Head↗

Lumbar spine mechanical response to axial compression load in vivo.

STUDY DESIGN: Lumbar spine kinematic response to a 1.0 body weight compressive load was measured in vivo by comparison of relaxed and loaded magnetic resonance image sets in the sagittal plane. OBJECTIVES: To identify and measure acute response mechanisms of the lumbar spine during compression loading. SUMMARY OF BACKGROUND DATA: The isolated ligamentous spine buckles under small loads (88 N); yet, the spine supports >10 times that load in daily activities. Mechanical function of the lumbar spine in vivo is not well understood, and only a few studies examined the spine during in vivo loading. METHODS: Magnetic resonance imaging scans of subjects were taken while subjects were relaxed and while supporting a 1.0 body weight compressive load. Vertebral bodies and disc perimeters were digitized, and relative centroid positions were measured and compared between conditions. Lumbar rotation, bending, compression, and disc translation were determined. Two parameter ensembles were analyzed to describe mechanisms of "spine shrinkage" (decrease of projected spine length) and lumbosacral response. RESULTS: All subjects underwent spine shrinkage (-3.9 +/- 1.2 mm) dominated by cumulative bending, except in three subjects where the rotation component dominated. Levels L2-L4 extended, while L5 flexed, and dL2 through dL4 translated anterior, while dL5 translated posterior. Significant segmental deformations were as follows: L3 extension (-3.3 +/- 3.1 degrees ), dL5 disc translation (-1.4 +/- 1.4 mm), and posterior sacral rotation (3.2 +/- 4.7 degrees ). CONCLUSIONS: Spine shrinkage occurred mainly from spine bending and rotation, with only small contribution from spine compression (shortening along the spine curvature). Response pattern groupings indicated at least two unique subgroups, but the cause remains to be determined.

Adult↗

Simvastatin exerts both anti-inflammatory and cardioprotective effects in apolipoprotein E-deficient mice.

BACKGROUND: Simvastatin attenuates ischemia and reperfusion in normocholesterolemic animals by stabilizing endothelial nitric oxide synthase activity and inhibiting neutrophil-mediated injury. Because endothelial dysfunction is a detrimental effect of hypercholesterolemia, we examined whether short-term treatment with simvastatin could inhibit leukocyte-endothelium interaction and attenuate myocardial ischemia-reperfusion injury in apoE-deficient (apoE(-/-)) mice fed a high-cholesterol diet. METHODS AND RESULTS: We studied leukocyte-endothelium interactions in apoE(-/-) mice fed a normal or a high-cholesterol diet after short-term (ie, 18 hours) simvastatin treatment. We also studied simvastatin treatment in myocardial ischemia-reperfusion injury by subjecting apoE(-/-) mice to 30 minutes of ischemia and 24 hours of reperfusion. ApoE(-/-) mice fed a high-cholesterol diet exhibited higher blood cholesterol levels, which were not affected by short-term simvastatin treatment. However, the increased leukocyte rolling and adherence that occurred in cholesterol-fed apoE(-/-) mice (P<0.001 versus control diet) were significantly attenuated by simvastatin treatment (P<0.01 versus vehicle). Cholesterol-fed apoE(-/-) mice subjected to myocardial ischemia-reperfusion also experienced increased myocardial necrosis (P<0.01 versus control diet), which was significantly attenuated by simvastatin (P<0.01 versus vehicle). Simvastatin therapy also significantly increased vascular nitric oxide production in apoE(-/-) mice. CONCLUSIONS: Simvastatin attenuates leukocyte-endothelial cell interactions and ameliorates ischemic injury in hypercholesterolemic mice independently of lipid-lowering actions.

Animals↗

Spatial variation in cartilage T2 of the knee.

Technical limitations imposed by resolution and B1 homogeneity have thus far limited quantitative in vivo T2 mapping of cartilage to the patella. The purpose of this study is to develop T2 mapping of the femoral/tibial joint and assess regional variability of cartilage T2 in the knee. Quantitative in vivo T2 mapping of the knee was performed on 15 asymptomatic adults (age, 22-44) using a 3T MR scanner. There is a consistent pattern of spatial variation in cartilage T2 with longer values near the articular surface. The greatest variation occurs in the patella, where T2 increases from 45.3 +/- 2.5 msec at a normalized distance of 0.33-67 +/- 5.5 msec at a distance of 1.0. These results demonstrate feasibility of performing in vivo T2 mapping of femoral tibial cartilage. Except for the superficial 15% where T2 values are lower, the spatial variation in T2 of femoral and tibial cartilage is similar to patellar cartilage.

Adult↗

Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90 degrees " RF pulse for the head in the birdcage coil.

Calculations of the RF magnetic (B(1)) field as a function of frequency between 64 and 345 MHz were performed for a head model in an idealized birdcage coil. Absorbed power (P(abs)) and SNR were calculated at each frequency with three different methods of defining excitation pulse amplitude: maintaining 90 degrees flip angle at the coil center (center alpha = pi/2), maximizing FID amplitude (Max. A(FID)), and maximizing total signal amplitude in a reconstructed image (Max. A(image)). For center alpha = pi/2 and Max. A(image), SNR increases linearly with increasing field strength until 260 MHz, where it begins to increase at a greater rate. For these two methods, P(abs) increases continually, but at a lower rate at higher field strengths. Above 215 MHz in MRI of the human head, the use of FID amplitude to set B(1) excitation pulses may result in apparent decreases in SNR and power requirements with increasing static field strength. Magn Reson Med 45:684-691, 2001.

Head↗

Calculations of B(1) distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model.

Calculations of the radiofrequency magnetic (B(1)) field, SAR, and SNR as functions of frequency between 64 and 345 MHz for a surface coil against an anatomically-accurate human chest are presented. Calculated B(1) field distributions are in good agreement with previously-published experimental results up to 175 MHz, especially considering the dependence of field behavior on subject anatomy. Calculated SNR in the heart agrees well with theory for low frequencies (nearly linear increase with B(0) field strength). Above 175 MHz, the trend in SNR with frequency begins to depend largely on location in the heart. At all frequencies, present limits on local (1 g) SAR levels are exceeded before limits on whole-body average limits. At frequencies above 175 MHz, limits on SAR begin to be an issue in some common imaging sequences. These results are relevant for coils and subjects similar to those modeled here. Magn Reson Med 45:692-699, 2001.

Humans↗

7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

Signal-to-noise ratio (SNR), RF field (B(1)), and RF power requirement for human head imaging were examined at 7T and 4T magnetic field strengths. The variation in B(1) magnitude was nearly twofold higher at 7T than at 4T ( approximately 42% compared to approximately 23%). The power required for a 90 degrees pulse in the center of the head at 7T was approximately twice that at 4T. The SNR averaged over the brain was at least 1.6 times higher at 7T compared to 4T. These experimental results were consistent with calculations performed using a human head model and Maxwell's equations. Magn Reson Med 46:24-30, 2001.

Brain↗

Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: experimental and theoretical dependence on sample properties.

The RF B(1) distribution was studied, theoretically and experimentally, in phantoms and in the head of volunteers using a 3 T MRI system equipped with a birdcage coil. Agreement between numerical simulation and experiment demonstrates that B(1) distortion at high field can be explained with 3D full-Maxwell calculations. It was found that the B(1) distribution in the transverse plane is strongly dependent on the dielectric properties of the sample. We show that this is a consequence of RF penetration effects combined with RF standing wave effects. In contrast, along the birdcage coil z-axis the B(1) distribution is determined mainly by the coil geometry. In the transverse plane, the region of B(1) uniformity (within 10% of the maximum) was 15 cm with oil, 6 cm with distilled water, 11 cm with saline, and 10 cm in the head. Along z the B(1) uniformity was 9 cm with phantoms and 7 cm in the head.

Brain Mapping↗

Fatal neonatal echovirus 6 infection: autopsy case report and review of the literature.

A full-term, healthy male neonate was delivered by caesarian section to a 26-year-old primigravida woman who had a history of fever and upper respiratory tract infection. On the fourth day of life, the neonate developed a sepsis-like syndrome, acute respiratory and renal failure, and disseminated intravascular coagulopathy. He died 13 days after birth. Postmortem examination revealed jaundice, anasarca, massive hepatic necrosis, adrenal hemorrhagic necrosis, renal medullary hemorrhage, hemorrhagic noninflammatory pneumonia, and severe encephalomalacia. Echovirus type 6 was isolated from blood, liver, and lungs. Although uncommon, echovirus type 6 infection may produce a spectrum of pathologic findings similar to those seen with the more commonly virulent echovirus type 11.

Adrenal Glands↗

Missed diaphragm rupture following blunt trauma.

Traumatic rupture of the diaphragm resulting from blunt trauma remains a challenging clinical entity. Diagnosis remains difficult and is often delayed. A prompt diagnosis requires a high index of suspicion. We describe two patients with ruptured diaphragms in whom the diagnosis was made at different stages of their illness. The diaphragmatic injury reflects the magnitude of their associated injuries and probably contributes to the overall mortality.

Adult↗

Clinical and pathologic features of Mycobacterium fortuitum infections. An emerging pathogen in patients with AIDS.

The clinical and pathologic features of Mycobacterium fortuitum infection in 11 patients with AIDS were characterized. Nine patients had cervical lymphadenitis; 2 had disseminated infection. The infection occurred late in the course of AIDS, and the only laboratory abnormality seen in more than half of patients (7/11) was relative monocytosis. Absolute monocytosis also was seen in 4 of 11 patients. In both cytologic and histologic preparations, the inflammatory pattern was suppurative with necrosis or a mixed suppurative-granulomatous reaction. M fortuitum, a thin, branching bacillus, stained inconsistently in direct smear and histologic preparations. Staining was variable with Gram, auramine, Brown-Hopps, Gram-Weigert, Kinyoun, Ziehl-Neelsen, modified Kinyoun, and Fite stains. Organisms, when present, were always seen in areas of suppurative inflammation. Incorrect presumptive diagnosis, based on misinterpretation of clinical signs and symptoms or on erroneous identification of M fortuitum bacilli as Nocardia species, led to a delay in proper therapy for 7 of 11 patients. Definitive therapy after culture identification resulted in complete resolution of infection in all patients except 1.

AIDS-Related Opportunistic Infections↗

MR imaging and T2 mapping of femoral cartilage: in vivo determination of the magic angle effect.

OBJECTIVE: The purpose of this study was to perform a quantitative evaluation of the effect of static magnetic field orientation on cartilage transverse (T2) relaxation time in the intact living joint and to determine the magnitude of the magic angle effect on in vivo femoral cartilage. MATERIALS AND METHODS: Quantitative T2 maps of the femoral-tibial joint were obtained in eight asymptomatic male volunteers using a 3-T magnet. Cartilage T2 profiles (T2 vs normalized distance from subchondral bone) were evaluated as a function of orientation of the radial zone of cartilage with the applied static magnetic field (B(0)). RESULTS: At a normalized distance of 0.3 from bone, cartilage T2 is 8.6% longer in cartilage oriented 55 degrees to B(0) compared with cartilage oriented parallel with B(0). Greater orientation variation is observed in more superficial cartilage. At a normalized distance of 0.6, cartilage T2 is 18.3% longer. The greatest orientation effect is observed near the articular surface where T2 is 29.1% longer at 55 degrees. CONCLUSION: The effect of orientation on cartilage T2 is substantially less than that predicted from prior ex vivo studies. The greatest variation in cartilage T2 is observed in the superficial 20% of cartilage. Given the small orientation effect, it is unlikely that the "magic angle effect" accounts for regional differences in cartilage signal intensity observed in clinical imaging. We hypothesize that regional differences in the degree of cartilage compression are primarily responsible for the observed regional differences in cartilage T2.

Adult↗

Treatment of severe thrombocytopenia in alloimmunized, transfusion-refractory patients.

A significant proportion of patients with hematologic malignancies who are exposed to multiple transfusions will develop alloantibodies to platelet human leukocyte antigens (HLA), resulting in poor responses to subsequent platelet transfusions. Transfusion of HLA-identical platelets is an effective method of platelet support in these patients, but perfectly HLA-matched platelets are often not available. In this paper, we review the recent literature on platelet transfusion support in alloimmunized individuals and illustrate alternative management strategies with cases from our own practice.

Adult↗