Publications and source records attributed to M Båth.

6 recordsLinked to original sources

Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluation.

Visual grading of the reproduction of important anatomical structures is often used to determine clinical image quality in radiography. However, many visual grading methods incorrectly use statistical methods that require data belonging to an interval scale. The rating data from the observers in a visual grading study with multiple ratings is ordinal, meaning that non-parametric rank-invariant statistical methods are required. This paper describes such a method for determining the difference in image quality between two modalities called visual grading characteristics (VGC) analysis. In a VGC study, the task of the observer is to rate his confidence about the fulfilment of image quality criteria. The rating data for the two modalities are then analysed in a manner similar to that used in receiver operating characteristics (ROC) analysis. The resulting measure of image quality is the VGC curve, which--for all possible thresholds of the observer for a fulfilled criterion--describes the relationship between the proportions of fulfilled image criteria for the two compared modalities. The area under the VGC curve is proposed as a single measure of the difference in image quality between two compared modalities. It is also described how VGC analysis can be applied to data from an absolute visual grading analysis study.

Data Interpretation, Statistical↗

Using simple mathematical functions to simulate pathological structures--input for digital mammography clinical trial.

In this study a set of structures has been simulated to represent a range of clinically relevant breast cancer mammographic lesions including solid tumours and microcalcifications. All structures have been created using simple random-based mathematical functions and have been inserted into a subset of digital mammography images at appropriate contrast levels into various regions of the breast, including dense fibroglandular and adipose tissue. These structures and their appearance in these clinical images were evaluated in terms of how realistic they looked. They will be used as the input to a large-scale clinical trial designed to examine the effect of significant dose reduction in digital mammography by comparing the detectability of such structures in images acquired at full and quarter automatic exposure control (AEC) dose level and in images with simulated noise levels in between.

Adipose Tissue↗

Can the average glandular dose in routine digital mammography screening be reduced? A pilot study using revised image quality criteria.

There is a need for tools that in a simple way can be used for the evaluation of image quality related to clinical requirements in mammography. The aim of this work was to adjust the present European image quality criteria to be relevant also for digital mammography images, and to use as simple and as few criteria as possible. A pilot evaluation of the new set of criteria was made with mammograms of 28 women from a General Electric Senographe 2000D full-field digital mammography system. One breast was exposed using the standard automatic exposure mode, the other using about half of that absorbed dose. Three experienced radiologists evaluated the images using visual grading analysis technique. The results indicate that the new quality criteria can be used for the evaluation of image quality related to clinical requirements in digital mammography in a simple way. The results also suggest that absorbed doses for the mammography system used may be substantially reduced.

Aged↗

Threshold pixel size for shape determination of microcalcifications in digital mammography: a pilot study.

The effect of pixel size on shape determination in screening digital mammography systems was studied using a shape identification task as the measured outcome. Ten microcalcifications on screen-films were digitised to a range of pixel sizes (2.5-200 microm) and extracted from computed radiography (CR) images (50 microm) acquired under equivalent imaging conditions. Fifteen observers attempted to identify the shape of each microcalcification at each pixel size. The results were collated to provide a fraction of correct responses vs. pixel size curve for each microcalcification. Averaging over all shapes, pixel values >100 microm lead to a significant decrease in shape determination ability (p < 0.01) for digitised screen-film. For CR images, half the shapes were not properly identified. Hence, although 20-100 microm was sufficient for microcalcification shape determination for digitised screen-film images, 50 microm was only borderline sufficient for the CR digital images.

Breast Diseases↗

Clinical evaluation of a new set of image quality criteria for mammography.

The European Commission (EC) quality criteria for screen-film mammography are used as a tool to assess image quality. A new set of criteria was developed and initially tested in a previous study. In the present study, these criteria are further evaluated using screen-film mammograms that have been digitised, manipulated to simulate different image quality levels and reprinted on film. Expert radiologists have evaluated these manipulated images using both the original (EC) and the new criteria. A comparison of three different simulated dose levels reveals that the new criteria yield a larger separation of image criteria scores than the old ones. These results indicate that the new set of image quality criteria has a higher discriminative power than the old set and thus seems to be more suitable for evaluation of image quality in mammography.

Europe↗

The influence of different technique factors on image quality of chest radiographs as evaluated by modified CEC image quality criteria.

The Commission of the European Communities (CEC) research project "Predictivity and optimisation in medical radiation protection" addressed fundamental operational limitations in existing radiation protection mechanisms. The first part of the project aimed at investigating (1) whether the CEC image quality criteria could be used for optimization of a radiographic process and (2) whether significant differences in image quality based on these criteria could be detected in a controlled project with well known physical and technical parameters. In the present study, chest radiographs on film were produced using healthy volunteers. Four physical/technical parameters were varied in a carefully controlled manner: tube voltage (102 kVp and 141 kVp), nominal speed class (160 and 320), maximum film density (1.3 and 1.8) and method of scatter reduction (grid (R=12) and air gap). The air kerma at the entrance surface was measured for all patients and the risk-related dose H(Golem), based on calculated organ-equivalent dose conversion coefficients and the measured entrance air kerma values, was calculated. Image quality was evaluated by a group of European expert radiologists using a modified version of the CEC quality criteria. For the two density levels, density level 1.8 was significantly better than 1.3 but at the cost of a higher patient radiation exposure. The correlation between the number of fulfilled quality criteria and H(Golem) was generally poor. An air gap technique resulted in lower doses than scatter reduction with a grid but provided comparable image quality. The criteria can be used to highlight optimum radiographic technique in terms of image quality and patient dose, although not unambiguously. A recommendation for good radiographic technique based on a compromise between image quality and risk-related radiation dose to the patient is to use 141 kVp, an air gap, a screen-film system with speed 320 and an optical density of 1.8.

Adult↗