PubMed Health⌕ Search

Biomedical subjects

M Bade

Publications and source records attributed to M Bade.

3 recordsLinked to original sources

Efficacy of a proximal occlusion catheter with reversal of flow in the prevention of embolic events during carotid artery stenting: an experimental analysis.

OBJECTIVE: The role of percutaneous angioplasty and stenting of carotid bifurcation lesions has been limited by its potential for producing embolic debris. We evaluated the efficacy of a proximal occlusion catheter (POC) in the prevention of embolic events during carotid artery stenting. In addition, pressure measurements relevant to the clinical application of this device were obtained from 10 patients undergoing carotid endarterectomy. METHODS: The POC is a guiding catheter with an occlusion balloon attached on the outside of the catheter at its distal end. Occlusion of the common carotid artery (CCA) was achieved by inflating the balloon while access to carotid bifurcation lesions was obtained through the inner lumen. The POC was inserted in the CCA of 10 dogs via the femoral artery. The side port of the POC was connected to a sheath placed in the femoral vein, thereby creating an external arteriovenous shunt. Ten artificial radiopaque particles simulating embolic particles and contrast agent were introduced in the CCA and monitored fluoroscopically. As a control, the same procedure was performed with a standard guiding catheter without an occlusion balloon. In 10 patients undergoing carotid endarterectomy, the internal carotid artery (ICA) and external carotid artery stump pressures and the pressure in the internal jugular vein were measured. RESULTS: Without the external arteriovenous shunt, in all animals there was prograde flow in the distal CCA despite CCA occlusion. This flow was derived from the thyroid artery. However, once the arteriovenous shunt was activated, reversal of flow in the distal CCA was achieved in each animal, and all the artificial particles were recovered from the side port of the POC. In the control group, each particle embolized to the brain (100%, P <.01). In the patients, the mean stump pressures in the ICA and external carotid artery and the jugular vein pressure were 51.8 +/- 14.2, 62.2 +/- 15.1, and 6.5 +/- 3.5 mm Hg, respectively. In each case, the jugular vein pressure was the lowest among the three. CONCLUSIONS: Obtaining proximal CCA control by inflating the POC does not sufficiently prevent embolization. However, reversal of flow in the ICA can always be created with the external shunt, which effectively prevents embolization. Thus, POC may markedly lower procedural stroke rates during carotid artery stenting. The ability of POC to prevent embolization before crossing the lesion with a guidewire may be an important advantage over other distal protection devices.

Angioplasty, Balloon↗

Increasing incidence of midterm and long-term complications after endovascular graft repair of abdominal aortic aneurysms: a note of caution based on a 9-year experience.

OBJECTIVE: To analyze the late complications after endovascular graft repair of elective abdominal aortic aneurysms (AAAs) at the authors' institution since November 1992. SUMMARY BACKGROUND DATA: Recently, the use of endovascular grafts for the treatment of AAAs has increased dramatically. However, there is little midterm or long-term proof of their efficacy. METHODS: During the past 9 years, 239 endovascular graft repairs were performed for nonruptured AAAs, many (86%) in high-risk patients or in those with complex anatomy. The grafts used were Montefiore (n = 97), Ancure/EVT (n = 14), Vanguard (n = 16), Talent (n = 47), Excluder (n = 20), AneuRx (n = 29), and Zenith (n = 16). All but the AneuRx and Ancure repairs were performed as part of a U.S. phase 1 or phase 2 clinical trial under a Food and Drug Administration investigational device exemption. Procedural outcomes and follow-up results were prospectively recorded. RESULTS: The major complication and death rates within 30 days of endovascular graft repair were 17.6% and 8.5%, respectively. The technical success rate with complete AAA exclusion was 88.7%. During follow-up to 75 months (mean +/- standard deviation, 15.7 +/- 6.3 months), 53 patients (22%) died of unrelated causes. Two AAAs treated with endovascular grafts ruptured and were surgically repaired, with one death. Other late complications included type 1 endoleak (n = 7), aortoduodenal fistula (n = 2), graft thrombosis/stenosis (n = 7), limb separation or fabric tear with a subsequent type 3 endoleak (n = 1), and a persistent type 2 endoleak (n = 13). Secondary intervention or surgery was required in 23 patients (10%). These included deployment of a second graft (n = 4), open AAA repair (n = 5), coil embolization (n = 6), extraanatomic bypass (n = 4), and stent placement (n = 3). CONCLUSION: With longer follow-up, complications occurred with increasing frequency. Although most could be managed with some form of endovascular reintervention, some complications resulted in a high death rate. Although endovascular graft repair is less invasive and sometimes effective in the long term, it is often not a definitive procedure. These findings mandate long-term surveillance and prospective studies to prove the effectiveness of endovascular graft repair.

Aged↗