PubMed Health⌕ Search

Biomedical subjects

M Barut

Publications and source records attributed to M Barut.

7 recordsLinked to original sources

Large-scale methacrylate monolithic columns: design and properties.

Monoliths represent a special class of chromatographic supports. In contrast to other stationary phases, they consist of a single piece of highly porous material through which a sample is mainly transported by convection. As a consequence, monoliths enable fast separations and exhibit flow-unaffected properties, which make them attractive for purification of macromolecules like proteins or DNA. In this work, methacrylate-based monolithic columns with the bed volume up to 8000 ml are characterized. They perform high-resolution separations of several hundreds of grams of proteins per hour by utilizing liter per minute flow rates. They are incompressible under these operating conditions and resistant to strong alkaline conditions.

Animals↗

Application of semi-industrial monolithic columns for downstream processing of clotting factor IX.

It has been shown in a previous study that monolithic columns can be used for downstream processing of different concentrates of clotting factor IX [K. Branović et al., J. Chromatogr. A 903 (2000) 21]. This paper demonstrates that such supports are useful tools also at an early stage of the purification process of factor IX from human plasma. Starting with the eluate after solid-phase extraction with DEAE-Sephadex, the use of monolithic columns has allowed much better purification than that achieved with conventional anion-exchange supports. The period of time required for separation is also much reduced. In up-scaling experiments, separations are carried out with 8, 80 and 500 ml columns. A volume of 1830 ml of DEAE-Sephadex eluate, containing a total of 27.6 g of protein and 48500 IU of factor IX is applied to the 500 ml monolithic column. This corresponds to a separation on a pilot scale. The results of this separation after up-scaling are comparable to those obtained with the 8 ml column on a laboratory scale.

Chromatography, Liquid↗

Very fast analysis of impurities in immunoglobulin concentrates using conjoint liquid chromatography on short monolithic disks.

Transferrin and albumin are often present in immunoglobulin G (IgG) concentrates and are considered as impurities. Therefore, it is important to determine their concentration in order to obtain a well-characterized biological product. Here, we describe their determination based on conjoint liquid chromatography (CLC). The established method combines two different chromatographic modes in one step: affinity and ion-exchange chromatography (IEC) combined in one column. Therefore, two CIM Protein G and one CIM quaternary amine (QA) monolithic disks were placed in series in one housing forming a CLC monolithic column. Binding conditions were optimized in a way that immunoglobulins were captured on the CIM Protein G disks, while transferrin and albumin were bound on the CIM QA disks. Subsequently, transferrin and albumin were eluted separately by a stepwise gradient with sodium chloride, whereas immunoglobulins were released from the Protein G ligands by applying low pH. A complete separation of all three proteins was achieved in less than 5 min. The method permits the quantification of albumin and transferrin in IgG concentrates and has been successfully validated.

Amines↗

Construction of large-volume monolithic columns.

Monolithic supports have become the subject of extensive study in the past years. Despite their advantageous features and many successful chromatographic applications in the analytical scale, only a very few examples of larger volume monoliths were described. In the case of GMA-EDMA monoliths, this can be attributed to the fact that due to the exothermic polymerization a pronounced temperature increase inside the monolith significantly affects the structure. The temperature increase depends on the thickness of the monolith, and consequently, there is an upper limit that allows the preparation of a unit with a uniform structure. In the present work, we have analyzed a heat release during the polymerization and have derived a mathematical model for the prediction of the maximal thickness of the monolithic annulus having a uniform structure. On the basis of the calculations, two annuluses of different diameters were polymerized and merged into a single monolithic unit with a volume of 80 mL. In addition, a special housing was designed to provide a uniform flow distribution in the radial direction over the entire monolith bed. It was shown that such a monolithic column exhibits flow-independent separation efficiency and dynamic binding capacity up to flow rates higher than 100 mL/min. The separation and loading times are in the range of a few minutes. The pressure drop on the column is linearly dependent on the flow rate and does not exceed 2.5 MPa at a flow rate of 250 ml/min.

Journal Article↗

Application of monoliths for downstream processing of clotting factor IX.

In this paper, the application of monolithic columns for downstream processing of different clotting factor IX concentrates is shown. Determination of basic chromatographic conditions as well as investigations on the regeneration of disk- and tube-shaped monolithic columns using human serum albumin as a model protein, were performed. Separation of factor IX and vitronectin, a possible impurity in commercial factor IX concentrates was accomplished using disk-shaped monolithic columns. These same applications were also carried out with identical results on up-scaled tube-shaped monolithic columns. Since these media allow very fast separations, this method can be successfully applied not only to an in-process control of the purification of factor IX but also to other biopolymers from human plasma. Besides, the same application on the up-scaled tube-shaped monolithic column was successfully carried out.

Biopolymers↗

Use of compact, porous units with immobilized ligands with high molecular masses in affinity chromatography and enzymatic conversion of substrates with high and low molecular masses.

Different ligands with high molecular masses are immobilized on compact, porous separation units and used for affinity chromatography. In subsequent experiments different enzymes are immobilized and used for converting substrates with low and high molecular masses. Disk or tube with immobilized concanavalin A (ConA) are used as model systems for lectin affinity chromatography. The enzyme glucose oxidase is used as a standard protein to test the ConA units. Subsequently glycoproteins from plasma membranes of rat liver are separated, using units with immobilized ConA. The enzyme dipeptidyl peptidase i.v., which is used as a model protein in the experiments, is enriched about 40-fold in a single step, with a yield of over 90%. The results are only slightly better than those obtained with ConA when it is immobilized on bulk supports. The important improvement lies in the reduction of separation time to only 1 h. Experiments concerning the isolation of monoclonal antibodies against clotting factor VIII (FVIII) are carried out on disks, combining anion-exchange chromatography and protein A affinity chromatography as a model for multidimensional chromatography. Both IgG (bound to the protein A disk) and accompanying proteins (bound to the anion-exchange disk) from mouse ascites fluid are retarded and eluted separately. With the immobilized enzymes invertase and glucose oxidase (GOX) the corresponding substrates with low molecular masses, saccharose and glucose, are converted. It is shown that the amount of immobilized enzyme and the concentration of the substrate are responsible for the extent of the conversion, whereas the flow-rates used in the experiments have no effect at all. The influence of immobilization chemistry was investigated with GOX. Indirect immobilization with ConA as spacer proved to be the best alternative. With trypsin, immobilized on a disk, substrates with high molecular masses are digested in flow-through. For optimal digestion the proteins have to be denatured in the buffer for sodium dodecyl sulfate-polyacrlyamide gel electrophoresis prior to application. In contrast to the conversion of substrates with low molecular masses, flow-rates play an important part in conversion of substrates with high molecular masses. With lower flow-rates a higher degree of digestion is achieved.

Animals↗

Application of compact porous tubes for preparative isolation of clotting factor VIII from human plasma.

Membranes as well as compact porous disks are successfully used for fast analytical separations of biopolymers. So far, technical difficulties have prevented the proper scaling-up of the processes and the use of membranes and compact disks for preparative separations in a large scale. In this paper, the use of a compact porous tube for fast preparative separations of proteins is shown as a possible solution to these problems. The units have yielded good results, in terms of performance and speed of separation. The application of compact porous tubes for the preparative isolation of clotting factor VIII from human plasma shows that this method can even be used for the separation of very sensitive biopolymers. As far as yield and purity of the isolated proteins are concerned, the method was comparable to preparative column chromatography. The period of time required for separation was five times shorter than with corresponding column chromatographic methods. Compact porous disks made of the same support material can also be used for in-process analysis in order to control the separation. The quick response, which is obtained from these units within 5 to 60 s, allows close monitoring of the purification process.

Chromatography, High Pressure Liquid↗