PubMed Health⌕ Search

Biomedical subjects

M Bechmann

Publications and source records attributed to M Bechmann.

At least 19 recordsLinked to original sources

Phosphorus losses from agricultural areas in river basins: effects and uncertainties of targeted mitigation measures.

In this paper we show the quantitative and relative importance of phosphorus (P) losses from agricultural areas within European river basins and demonstrate the importance of P pathways, linking agricultural source areas to surface water at different scales. Agricultural P losses are increasingly important for the P concentration in most European rivers, lakes, and estuaries, even though the quantity of P lost from agricultural areas in European catchments varies at least one order of magnitude (<0.2 kg P ha(-1) to >2.1 kg P ha(-1)). We focus on the importance of P for the implementation of the EU Water Framework Directive and discuss the benefits, uncertainties, and side effects of the different targeted mitigation measures that can be adopted to combat P losses from agricultural areas in river basins. Experimental evidence of the effects of some of the main targeted mitigation measures hitherto implemented is demonstrated, including: (i) soil tillage changes, (ii) treatment of soils near ditches and streams with iron to reduce P transport from source areas to surface waters, (iii) establishment of buffer zones for retaining P from surface runoff, (iv) restoration of river-floodplain systems to allow natural inundation of riparian areas and deposition of P, and (v) inundation of riparian areas with tile drainage water for P retention. Furthermore, we show how river basin managers can map and analyze the extent and importance of P risk areas, exemplified by four catchments differing in size in Norway, Denmark, and the Netherlands. Finally, we discuss the factors and mechanisms that may delay and/or counteract the responses of mitigation measures for combating P losses from agricultural areas when monitored at the catchment scale.

Agriculture↗

Scanning laser ophthalmoscope-evoked multifocal ERG (SLO-mfERG) in patients with macular holes and normal individuals.

AIMS: A scanning laser ophthalmoscope (SLO) has been used for multifocal electroretinography (mf ERG) measurements under simultaneous fundus monitoring. The aim of this study was to prove if the SLO-mfERG measurement reflects reliably the clinically registered underlying disease, and to demonstrate the importance of its main advantage, fixation monitoring. METHODS: In all, 10 patients with macular hole stage II/III were included in the study, and 19 normal individuals served as the control group. The mf ERG device was combined with an SLO, which was used both as a stimulus and trigger unit as well as a fundus-monitoring system. Monitoring of the fundus was guaranteed by an infrared laser (780 nm). The stimulus matrix consisted of 61 hexagonal elements, covering 24 degrees of the posterior pole. We examined both, patients with macular holes and healthy individuals. RESULTS: Compared to normal controls, patients with a macular hole (Gass stage III) showed a significant decrease in response density in the centre of the stimulus array, which correlated well with the morphological alteration observed by clinical examination. However, variation of response density of the central hexagonal area has been proved to be high. CONCLUSIONS: SLO-mfERG is a feasible and reliable new technique to investigate macular function under simultaneous fundus control. The main advantage is that control of fixation can be used in order to obtain more reliable results that correlate well with visible fundus abnormalities such as in patients with macular holes. However, further investigations have to be performed in order to overcome sufficiently the problem of fixation instability.

Adult↗

[Relationship between lens power in refraction].

BACKGROUND: To achieve emmetropia, several components such as the cornea and lens power, and axial length have to be coordinated. Until now, not much is known about the influence of these factors on each other. METHODS: A total of 66 healthy subjects were enrolled in this study. Ocular dimensions including anterior chamber depth, lens thickness, vitreous chamber depth, and axial length were measured by A-scan ultrasonography. Corneal radius and corneal refractive power were determined by ophthalmometry. The equivalent lens power was calculated by a method based on the Gullstrand schematic eye. RESULTS: As expected, a good correlation was found to exist between refraction and axial length. Lens power was independent of refraction, but in emmetropic eyes a good correlation between lens power and axial length could be found. Higher axial length was related to lower values of lens power and vice versa. CONCLUSION: In emmetropic eyes, deviation of axial length seems to be compensated by lens power and if this mechanism does not function, ametropia results.

Adult↗

[New automated microkeratome for trepanation of lamellar keratoplasty].

BACKGROUND/PURPOSE: Lamellar keratoplasty is an established therapy of corneal pathologies without endothelial involvement and the lack of endothelial rejection is one of the major advantages compared to penetrating keratoplasty. The major disadvantages of manually prepared lamellar corneal grafts are the limited mechanical and optical quality but the automated lamellar therapeutic keratoplasty system ALTK (MORIA) is intended to overcome these disadvantages. The purpose of this preliminary work is to investigate histologically and in clinical cases, if the ALTK system can achieve this aim. PATIENTS AND METHODS: Corneas from two human donors were cut with a 300 microns trephine. After fixation, the stromal bed and the excised cup of one specimen were stained with PAS and examined by light microscopy and the other specimen was analyzed by scanning electron microscopy. In addition, follow-up data of two patients who received such a lamellar graft are reported for the first 9 and 7 months postoperation, respectively. RESULTS: The lamellar cut of homogeneous depth revealed only minor stromal trauma. Both clinical cases demonstrated only minimal interface haze during follow-up. Despite a remarkably clear cornea, visual acuity improved only slowly because the precise lamellar cut tended to partially reproduce any preexisting irregular astigmatism. CONCLUSIONS: The ALTK system simplifies and standardizes the trephination of lamellar corneal grafts but a longer follow up is necessary with respect to visual development and preservation of a clear graft.

Adult↗

SOIL and SOIL-NO at catchment scale--a case study for an agriculture-dominated catchment.

A one-dimensional model, SOIL/SOIL-NO, is used to simulate the water and nitrogen balance at catchment scale. The objective is to use the model in simulating the effects of best management practices on nitrogen runoff. The model was applied to individual farm fields in an agriculture dominated catchment and simulations were carried out for the period from 94-98. The results were promising. The simulated nitrogen runoff agreed quite well with the measured nitrogen loss at the main station. The effects of best management practices like optimal fertiliser application, catch crops and irrigation were simulated. For this particular catchment, the introduction of catch crops resulted in the best effect on reducing nitrogen runoff from agricultural dominated catchments.

Agriculture↗

Double-quantum-filtered rotational-resonance MAS NMR in the presence of large chemical shielding anisotropies.

Double-quantum filtration under rotational resonance MAS NMR conditions where the chemical shielding anisotropies involved exceed the differences in isotropic chemical shielding is considered by means of numerical simulations and (13)C MAS NMR experiments. The responses of two different pulse sequences, suitable for double-quantum filtration specifically under rotational resonance conditions, to large chemical shielding anisotropies are compared. In the presence of large chemical shielding anisotropies a very recently introduced pulse sequence (T. Karlsson, M. Edén, H. Luthman, and M. H. Levitt, J. Magn. Reson. 145, 95-107, 2000) suffers losses in double-quantum-filtration efficiencies. The double-quantum-filtration efficiency of another pulse sequence (N. C. Nielsen, F. Creuzet, R. G. Griffin, and M. H. Levitt, J. Chem. Phys. 96, 5668-5677, 1992) is less afflicted by the presence of large chemical shielding anisotropies. Both sequences deliver double-quantum-filtered lineshapes that sensitively reflect chemical shielding tensor orientations. It is further shown that double-quantum-filtered rotational-resonance lineshapes of spin systems composed of more than two spins offer a suitable experimental approach for determining chemical shielding tensor orientations for cases where conventional rotational-resonance experiments are not applicable due to the presence of additional background resonances.

Anisotropy↗

X-linked ocular albinism (Nettleship-Falls): a novel 29-bp deletion in exon 1. Carrier detection by ophthalmic examination and DNA analysis.

BACKGROUND: Mutations in the OA1 gene on the short arm of the X chromosome are known to cause X-linked ocular albinism (x1OA) in males. A four-generation family with this disorder, including asymptomatic carrier females, was investigated by molecular analysis of the OA1 gene. METHODS: DNA samples were available from 22 individuals of this family, including 6 affected males and 6 obligate carriers. The nine exons of the OA1 gene were amplified and further analyzed by SSCP and sequencing. RESULTS: A detailed clinical examination of the index patient and two female carriers showed the typical signs of ocular albinism. Visual evoked potential responses showed markedly asymmetrical responses from the two hemispheres in the affected person as well as in the carriers, as a result of misrouting and decussation of optic nerve fibers. Molecular genetic analysis demonstrated a previously undescribed 29-bp deletion at position 225-253 in exon 1 of the OA1 gene, which segregated in the family. CONCLUSION: Clinical examination combined with molecular genetic analysis enhances the potential for a precise diagnosis for persons at risk of x1OA and provide an accurate basis for genetic counseling.

Adult↗

Macular hole surgery in an eye with an optic pit.

PURPOSE: To report an eye with a full-thickness macular hole and an associated optic pit and the noteworthy intraoperative findings. METHODS: Case report. A 56-year-old woman presented with visual acuity LE: 20/100, a full thickness macular hole, and an optic pit. Optical coherence tomography and ophthalmic examination were performed preoperatively and postoperatively. RESULTS: Although usually a macular hole associated with an optic pit tends to be a lamellar and characterized by outer layer defects within preexisting macular detachments or schisis-like cavities, this type of macular hole was not presented in this case. Although the macular hole resembled the idiopathic type on clinical examination as well as on optical coherence tomography, it could only be closed in the third surgical attempt after using silicone oil as a long-standing tamponade. Peeling of an epiretinal membrane or the internal limiting membrane was not possible during any of the three surgeries. CONCLUSION: Our observations suggest that in cases of macular hole in association with optic pit, instillation of silicone oil should be considered in the first surgical procedure, especially if no epiretinal membrane or internal limiting membrane peeling is possible intraoperatively.

Diagnostic Techniques, Ophthalmological↗

Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry.

PURPOSE: To demonstrate the capability of a standard, commercially available optical coherence tomography device (originally designed to measure retinal thickness) to image the human cornea in vivo and to measure central corneal thickness (CCT) in normal and edematous corneas. The intrapatient precision and interpatient variability of this novel application was compared to standard ultrasonic pachymetry. Also, the correlation of both methods was investigated. METHODS: CCT measurements using optical coherence tomography (OCT) and ultrasonic pachymetry (PACH) were obtained in 36 normal eyes and 16 eyes with corneal edema. RESULTS: Direct in vivo imaging of the cornea and measurements of CCT by OCT could be performed in all eyes. In normal subjects, CCT(OCT) was 530+/-32 microm and CCT(PACH) was 581+/-34 microm. The two methods showed a highly significant correlation with a standardized regression coefficient of 0.988. The difference between both methods was constant over the range of CCT (mean difference, 49.4+/-5.9 microm). The mean intrapatient SD of CCT measurements was 4.90 microm and 4.96 microm for OCT and PACH, respectively. In patients with corneal edema, mean CCT(OCT) was 601+/-59 microm, and mean CCT(PACH) was 667+/-68 microm. The difference between the two techniques increased slightly with increasing corneal edema (mean difference, 66.9+/-10.9 microm). CONCLUSION: Imaging of the human cornea can be performed by a standard retinal OCT device, and OCT measurement of CCT shows excellent correlation to values obtained by PACH, giving similar readings separated by a constant difference. In corneal edema, the difference between the two methods is additionally increased, but continues to demonstrate excellent consistency.

Adult↗

Comparison of foveal thickness measured with the retinal thickness analyzer and optical coherence tomography.

PURPOSE: To assess and compare the reliability and reproducibility of retinal thickness measurements for the retinal thickness analyzer (RTA) and optical coherence tomography (OCT) in normal and edematous retina. METHODS: The authors measured the foveal thickness of 21 normal eyes and 9 eyes with macular edema with both methods in random order. With the RTA, the fovea was measured 10 times; with the OCT, six scans (one horizontal and five vertical cross-sections) of the fovea were obtained. RESULTS: Mean foveal thickness of normal eyes measured 153 microm with OCT and 181 microm with RTA (median for both methods 150 microm). Coefficients of variation (CV) within the same subjects were 10% (OCT) and 9% (RTA) reducing to 9% (OCT) and 7% (RTA) when scans were repeated only five times for both methods. The RTA, however, yielded an interpatient CV of 33% (OCT 17%), which was caused by several falsely high readings in normal individuals. In eyes with retinal thickening the OCT measured a mean of 324 microm with 15% intra- and 58% interpatient CV. The RTA yielded a mean of 403 microm with CV of 18% and 73%, respectively. CONCLUSION: Both methods yield reproducible measurements of foveal thickness in normal individuals and individuals with macular edema. However, falsely high measurements may occur with the RTA, reducing its reliability as compared to the OCT.

Anthropometry↗

Vitreoretinal surgery: pre-emptive analgesia.

AIM: Vitrectomies are performed either under general anesthesia (GA), local anesthesia (LA), or a combination of both. Postoperative pain is expected to be less in patients with LA because of prolonged action of the local anaesthetic. Pre-emptive analgesia is based on the idea that analgesia initiated before a nociceptive event will be more effective than analgesia commenced afterwards. The authors compared postoperative analgesia in patients with GA combined with preoperative or postoperative LA. METHODS: 90 patients scheduled for vitrectomy without buckling were enrolled in the study. 60 patients underwent GA, 30 without LA, 15 with preoperative LA, and 15 with postoperative LA. 30 patients received LA alone. Subjective postoperative pain was determined using the visual analogue scale. RESULTS: Postoperative pain was less under LA alone compared to GA alone (p < 0.0001). Additional preoperative application of LA resulted in less pain than additional postoperative application (p <0.05). Additional postoperative peribulbar aneasthesia did not differ from GA alone. CONCLUSION: The authors conclude that LA alone or preoperatively in addition to GA provides the best comfort for the patient in vitreoretinal surgery.

Adolescent↗

[Imaging of vitreoretinal adhesions in the partner eye of patients with penetrating macular foramina in optical coherence tomography].

BACKGROUND: Vitreoretinal adhesions play a crucial role in the development of a macular hole. To visualize vitreoretinal adhesion we used optical coherence tomography to investigate fellow eyes of patients with macular holes. METHODS: In a prospective study we scanned the retina in 188 patients with a macular hole stage III or IV (Gass classification). The foveal shape and vitreous were classified into grades. RESULTS: Of the 188 patients 45% showed no vitreous reflex, 45% a partial vitreous detachment with foveolar adhesions, and 10% a vitreous detachment with complete separation from the fovea. While eyes with normal foveolar shape displayed partial vitreous detachment in 33%, this figure rose to 66% in eyes with a macular hole stage I. CONCLUSION: Diffuse thickening of the fovea is followed by an intraretinal split and formation of a cyst. The shape of the foveolar adhesion suggests that continuing anteroposterior vitreal traction leads to a retinal break and formation of a full-thickness macular hole.

Aged↗

Central corneal thickness determined with optical coherence tomography in various types of glaucoma.

AIMS: To evaluate central corneal thickness determined by optical coherence tomography (OCT) in various types of glaucoma, and its influence on intraocular pressure (IOP) measurement. METHODS: Central corneal thickness (CCT) was determined by using OCT in 167 subjects (167 eyes). 20 had primary open angle glaucoma (POAG), 42 had low tension glaucoma (LTG), 22 had ocular hypertension (OHT), 10 had primary angle closure glaucoma (AC), 24 had pseudoexfoliation glaucoma (PEX), 13 had pigmentary glaucoma (PIG), and 36 were normal. RESULTS: CCT was significantly higher in ocular hypertensive subjects (593 (SD 35) microm, p <0.0001) than in the controls (530 (32) microm), whereas patients with LTG (482 (28) microm, p < 0. 0001), PEX (493 (33) microm, p <0.0001), and POAG (512 (30) microm, p <0.05) showed significantly lower readings. There was no statistically significant difference between the controls and patients with PIG (510 (39) microm) and AC (539 (37) microm). CONCLUSIONS: Because of thinner CCT in patients with LTG, PEX, and POAG this may result in underestimation of IOP, whereas thicker corneas may lead to an overestimation of IOP in subjects with OH. By determining CCT with OCT, a new and precise technique to measure CCT, this study emphasises the need for a combined measurement of IOP and CCT in order to obtain exact IOP readings.

Aged↗

Purification of synaptic ribbons, structural components of the photoreceptor active zone complex.

Synaptic ribbons are plasma membrane-associated structural elements in photoreceptor synaptic terminals. They seem to act as high capacity "docking sites" of synaptic vesicles that provide the fusion sites of the photoreceptor synapse ("active zones"), with a large supply of immobilized synaptic vesicles rapidly available for exocytosis. Synaptic ribbons are regarded as a specialized type of presynaptic densities found in virtually all synapses. The molecular composition of presynaptic densities and synaptic ribbons is unknown. The aim of this study was the isolation of synaptic ribbons from photoreceptor synapses. For this purpose, we first isolated a membrane fraction from the bovine retina that was strongly enriched in photoreceptor synapses. From this fraction, a Triton X-100-resistant subfraction was purified that consisted mainly of synaptic ribbons and their disassembly products. The high enrichment of synaptic ribbons was verified by electron microscopy and immunolabeling using an antibody that specifically binds to synaptic ribbons. SDS-PAGE analysis of this synaptic ribbon fraction displayed several major polypeptide bands migrating at approximately 240, 60, 55, 43, and 30 kDa. The purification procedure described here is a first promising step toward the identification of the yet unknown constituents of synaptic ribbons from photoreceptor synapses and possibly also of presynaptic densities from other synapses.

Animals↗

Scanning laser ophthalmoscope-evoked multifocal-ERG (SLO-m-ERG) by using short m-sequences.

PURPOSE: To demonstrate the possibility of topographic mapping of retinal function under simultaneous control of fixation in humans, by scanning laser ophthalmoscope evoked multifocal electroretinography (SLO-m-ERG). METHODS: A confocal scanning laser ophthalmoscope was used as a stimulator and trigger unit to take m-ERGs. Short m-sequences based on a modified algorithm were used, with the advantage that each measurement cycle can be evaluated separately. We examined 78 normal subjects; in 62 a distortion factor of 1:1 was applied, and a factor of 1:4 in 16. RESULTS: The recorded amplitudes decreased with eccentricity, approximately following the decrease of retinal cone density. Amplitudes were higher in the central hexagonal element in the group with 1:4 distortion than in the group with the 1:1 distortion setting. CONCLUSIONS: SLO-m-ERG is a reliable technique for topographic mapping of retinal function under simultaneous control of fixation.

Adult↗