A new self-expandable, nickel-titanium coil stent for esophageal obstruction: a preliminary report.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Beyar.
Explore the source record for details and available documents.
An intraurethral sphincter prosthesis with a self contained urinary pump for the management of atonic bladder in women was developed and tested. The prosthesis is comprised of a short, self retaining silicone catheter in which there is a valve and pump. Available in a range of lengths and diameters according to urethral size, its insertion is similar to that of a urethral catheter. The prosthesis is secured by a novel fixation method that has soft expandable silicone fins at the bladder neck and a flexible flange at the external meatus. It is activated by a small hand-held control device. To urinate, the activator is placed on the lower abdomen area and the "on" button is pressed, providing energy to the pump by a magnetic coupling method. Once activated, the valve opens and the pump rotates at a high speed, drawing urine from the bladder and pushing it forward, allowing the patient to "void" with a urine flow of 10 to 12 cc/sec. When the bladder is completely evacuated, the pumping ceases and the valve closes, restoring continence. The device was evaluated clinically in 17 women. Fifteen of the patients had a range of use of 2 weeks to 16 months during which they were dry and had complete bladder emptying. Two patients did not tolerate the device because of uninhibited detrusor contractions and, in both cases, it was removed without complication after 5 days.
A new technique and related devices for the treatment of urinary incontinence in women was developed and tested. The technique involves soft tissue to bone fixation by means of miniature bone anchors and a bone anchor inserter. The novel bone anchors are made of a shape-memory nickel titanium alloy (Nitinol) attached to Polypropylene or Gortex suture. A spring-loaded bone anchor inserter drives the anchors through the vaginal wall to a predetermined depth into the pubic bone medulla regardless of the bone's hardness, with no incision or drilling required. The device allows for the performance of a minimally invasive transvaginal bladder neck suspension. The procedure has minimal morbidity and a short learning curve. This technique was evaluated clinically in 15 women with incontinence, with a mean follow-up of 6 months. Good urinary continence was achieved in all patients, with no mechanical failures.