Chiari network: an interesting transesophageal echocardiographic finding.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Bhise.
Explore the source record for details and available documents.
OBJECTIVE: To evaluate transesophageal echocardiography (TEE) as an intraoperative monitoring modality and to assess its safety, reliability, and overall utility in real-time use during cardiac surgery. DESIGN: Prospective, observational cohort study performed from January 1993 to June 1997. SETTING: Operating room of a tertiary care hospital for cardiology and cardiovascular surgery. PARTICIPANTS: Five thousand and sixteen adult patients with acquired heart disease, who underwent 1,356 valve procedures and 3,660 coronary artery bypass graftings (CABGs). INTERVENTIONS: All patients were monitored with radial artery and pulmonary artery catheters, along with continuous TEE monitoring with a multiplane transducer. MEASUREMENTS AND MAIN RESULTS: Prebypass imaging yielded unsuspected findings that either helped or modified the surgical plan in 158 of 1,356 valve procedures (11.65%) and in 993 of 3,660 CABGs (27.13%). There were 3,217 TEE-guided hemodynamic interventions in 944 patients (25.79%) in the CABG group and 629 in 142 patients (10.47%) in the valve group. TEE was the sole guiding factor in initiating therapy in 23.53% of events, whereas it was supportive to other monitoring modalities in 76.46% of events. Postbypass TEE identified the need for graft revision in 29 patients (0.8%), intra-aortic balloon pump (IABP) requirement in 29 patients (0.8%), and inadequate valve repair in 28 patients (2.08%). For the entire series, 38.78% of patients benefited from prebypass and 39.16% from postbypass use of TEE. There were no complications attributable to the use of TEE in the entire series. There was 87% concordance between online interpretation by a trained anesthesiologist and offline analysis by a cardiologist. CONCLUSION: Intraoperative TEE is useful in formulating the surgical plan, guiding various hemodynamic interventions, and assessing the immediate results of surgery. It is safe and the results are reliable in the hands of trained anesthesiologists.
A total of 476 internal jugular vein cannulations performed between June 1990 to August 1991 were prospectively evaluated. The patients' age ranged between ten days to 61 years. We achieved a high success rate of cannulation (97.9%). We describe the use of two single lumen catheters inserted through right internal jugular vein as an alternative to the popular multilumen catheters. We also suggest that low approach should be tried more often in children, if the central approach fails.
One hundred adult patients, undergoing elective open heart surgery over a period of 4 months, were studied to assess the practice of ventilation in the post operative period. The anaesthetic technique employed used moderate doses of morphine, supplemented with halothane and a muscle relaxant. The decision to extubate was based on clinical assessment, and satisfactory blood gases following a 45 minute T-piece trial. The patients were ventilated for an average duration of 8 hours and 2 minutes and 59 out of 100 patients were extubated within 8 hours. Patients undergoing coronary artery bypass graft were ventilated for significantly longer durations (10 hours 28 minutes) (p < 0.05) and had significantly lower arterial oxygen tension (p < 0.01) 30 minutes after extubation, as compared with those undergoing valvular surgery. Also patients whose bypass time exceeded 2 hours had significantly longer extubation times (p < 0.05) as compared with those who had a bypass time less than 1 hour. T piece trial was found to be a satisfactory method of weaning in all the patients.