Effect of heparin, aspirin, or alteplase in reduction of myocardial ischaemia in refractory unstable angina.

399 out of 474 inpatients with unstable angina were monitored for 48 h and 97 of these were found to be refractory to conventional antianginal treatments and entered a randomised double-blind study. With the initial protocol heparin infusion or bolus were compared with aspirin; with a modified protocol, heparin infusion, the best of these three treatments, was compared with alteplase. Patients were monitored for 3 days after starting treatment and then observed clinically for 4 more days. On the first days of treatment heparin infusion significantly decreased the frequency of angina (by 84-94%), episodes of silent ischaemia (by 71-77%), and the overall duration of ischaemia (by 81-86%). Heparin bolus and aspirin were not effective. Alteplase caused small (non-significant) reductions on the first day only. Only minor bleeding complications occurred.

Administration, Oral↗

Control of the physical parameters in local electromagnetic hyperthermia.

The evaluation of the clinical results in experimental applications of local electromagnetic hyperthermia requires strict control of the physical parameters of the treatment and adhesion to close medical protocols. Development and application processes in close cooperation between physicians and electromagnetic experts are reported and discussed, on the basis of experimental and theoretical research work. Attention is concentrated on a 434 MHz apparatus, where the fundamental physical limits have been identified and the operating features in the clinical practice have been evaluated. The cases eligible for treatment were chosen according basically to the limitations posed by depth, volume and steep temperature gradients. Several cases are reported mainly in association with radiotherapy. Lines of technical improvement are suggested, mainly based on the development and optimization of lower-frequency applicators.

Body Temperature↗

Thrombosis of portal vein in absence of hepatic disease.

Of 602 patients referred for portal hypertension during a 20 year period, 18 children (mean age of 5.0 years) and 29 adults (mean age of 26.5 years) had thrombosis in the portal bed with a healthy liver (7.8 per cent incidence). In 29 of the 47 patients we studied, the causative factor remained obscure. Variceal hemorrhage occurred in all and was the indication for our observation and treatment. In 11 adult patients (mean age of 22.1 years), surgical treatment was not performed because of reluctance of the patient or because of technical reasons: nine of the patients rebled and one patient died because of massive bleeding. Direct procedures on esophageal varices had a high rate of rebleeding (seven of 11 patients) independent of the age of the patient when the operation was performed. In 13 patients, shunting offered a good chance of long term protection: three of the 13 rebled at a mean follow-up study of 5.7 years. No recurrence of bleeding was observed in 15 patients when variceal eradication had been obtained after chronic endoscopic sclerotherapy at one to eight years of follow-up study (mean of 3.9 years). The data from this study indicate that sclerotherapy should be the first choice of treatment to control recurrent bleeding in extrahepatic portal hypertension caused by thrombotic obstruction, particularly in the young patient.

Adolescent↗

[Evolution of pregnancy in 14 patients with lupus nephropathy].

Authors have examined 14 pregnant patients with renal involvement by systemic lupus erythematosus. Variations in blood creatinine, proteinuria and blood pressure were considered in the prepregnancy, pregnancy and postpartum periods in relation to the histologic results of renal biopsy and obstetric outcome.

Adult↗

Analysis of electric and magnetic fields leaking from induction heaters.

Results are presented of an investigation on electric and magnetic fields leaking from inductive (magnetic) heaters that are used for thermal processing of high-power electron tubes and lasers in an industrial plant. Measurements of electric and magnetic fields were done using both commercially available and laboratory-developed instrumentation. Isotropic H-field sensors were developed to allow quantitative evaluation of high-intensity magnetic fields. Ten induction heaters with nominal A.C. power ranging from 2.5 kW to 15 kW and operating at frequencies between 300 kHz and 790 kHz were surveyed. Electric field strengths up to 8 kV/m and magnetic field strengths up to 20 A/m were measured.

Environmental Exposure↗

Exposure of workers to intense RF electric fields that leak from plastic sealers.

This paper presents the results of an environmental investigation in a plastic-ware industry using RF sealers. Environmental measurements have demonstrated the presence of strong electric fields the intensity of which: reaches significant levels from the health-protection point of view only in proximity to the applicators; often exceeds the maximal levels allowed by all standards (including the most permissive) for short duration exposures, especially in the region of the hands. Results of a cross-sectional study on the health of 63 female workers are related to the observed RF exposure. A statistically significant correlation was found to exist between RF exposure and some minor health effects--eye irritation, upper limb paresthesias, and vitreous body disorganization.

Equipment Safety↗

A radio-frequency monitor for protection against overexposure from RF heaters.

Extensive investigation on the various potentially polluting RF sources has led to the conclusion that the largest proportion of problems arising from possible RF hazards originates from industrial heating machines (short-wave). In particular, these turn out to require checks due to their intrinsic and induced instabilities. Through the analysis of RF leakage characteristics of these machines, the problem is simplified and the solution is presented in terms of an RF hazard monitor which can be used by non-specialized personnel. The monitor is also suitable for several other types of potentially dangerous apparatus in the medium- and short-wave range.

Environmental Exposure↗

Analysis of the effects of microwave energy on enzymatic activity of lactate dehydrogenase (LDH).

Interactions between microwave energy (3 GHz) and the enzyme Lactate Dehydrogenase (LDH) have been analyzed by monitoring the enzymatic activity during irradiation in steady-state or dynamic conditions, by irradiating the sample with variable power levels (up to 6 W into the sample) and, finally, by knowing accurately the true specific absorption rate. No permanent or temporary changes can be induced when the energy absorption does not cause a temperature variation. For higher energy values, effects are purely thermal in nature. Furthermore the thermal activation of the reaction velocity, caused by microwave irradiation, is in itself sufficient to give a good fit with the experimental time evolution of the enzymatic reaction.

Hot Temperature↗

Endocardial cushion defect and significant hypoplasia of the left ventricle: a distinct clinical and pathological entity.

We have identified 12 patients with endocardial cushion defect and marked under-development of the left ventricle. Most of these patients had significant obstructive anomalies of the aortic arch. Pathologically, the left ventricle was very small, but without endocardial fibroelastosis, significant subaortic narrowing was evident, resulting from maladherent atrioventricular valve tissue to the left ventricular outflow tract, and the left ventricular posterior leaflet component of the atrioventricular valve was both grossly deficient and dysplastic. In all 12 a large ostium primum atrial communication was present, but the ventricular contribution to the defect was small. The clinical presentation of severe, intractable congestive heart failure in these neonatal patients would suggest the diagnosis of typical hypoplastic left heart syndrome. Important departures in some of these patients included a leftward, superior and counterclockwise frontal vector on the electrocardiogram and a widely split second sound. Selective biplane angiocardiography will reveal the underdeveloped left ventricle, with an elongated, fixed, 'gooseneck' deformity of the left ventricular outflow tract, severe 'mitral' regurgitation, and a small ascending aorta. Selective right ventriculography will opacify the very much larger right ventricle and pulmonary artery. Finally, these cases broaden the concept of double inlet right ventricle and exaggerated displacement of the atrioventricular canal towards the bulbus cordis.

Angiocardiography↗