PubMed Health⌕ Search

Biomedical subjects

M Boettcher

Publications and source records attributed to M Boettcher.

9 recordsLinked to original sources

[Airbag associated deceleration trauma with complete infradiaphragmatic dissection of the inferior vena cava (IVC) and tear of liver veins].

Numerous investigations have demonstrated that the ability of passenger airbag systems to reduce both injury severity and mortality in car accidents is restricted to the simultaneous application of seatbelts and airbags. Depending on the impact force during the accident and also on the driver's position to the airbag an isolated airbag deployment can even produce severe injuries. We describe a complete infradiaphragmatic dissection of the IVC and a tear of liver veins after an airbag deployment without seatbelt use. We discuss different airbag associated injuries, the possible pathomechanism of the described injury, frequency and prognosis of abdominal vascular injuries and their emergency treatment. In the presented case the isolated severe vascular injury resulted in an intraoperative death caused by exsanguination. In blunt trauma with accompanying hypotension pre-arrival alarming of the ER, rapid transport to the hospital and immediate surgery are most important for the outcome.

Accidents, Traffic↗

Combined use of confocal laser scanning microscopy and transmission electron microscopy for visualisation of identical cells processed by cryotechniques.

Successive visualisation of identical plant cells by light and electron microscopy is reported. For this purpose segments of pea and barley leaves were prepared by high-pressure freezing, freeze-substitution, and low-temperature embedding. The use of Safranin O during low-temperature dehydration allowed, on one hand, staining of all cellular components as investigated by confocal laser scanning microscopy and, on the other hand, excellent ultrastructural and antigenic preservation. A newly constructed specimen holder enabled precise relocation of the target cells for electron microscopic investigations. Transmission electron microscopy and immunohistochemistry revealed that during the whole procedure the ultrastructure of the cells as well as the antigenicity of cell constituents were preserved.

Cryoelectron Microscopy↗

Precision and comparability of Abuscreen OnLine assays for drugs of abuse screening in urine on Hitachi 917 with other immunochemical tests and with GC/MS.

Abuscreen OnLine assays for drugs of abuse screening in urine have recently been developed for use on Hitachi 917 analyzers (Roche Diagnostics GmbH). The assays are based on the kinetic interaction of microparticles as measured by changes in light transmission. Drug in a sample inhibits the formation of particle aggregates and diminishes absorbance change increases. It was the goal of this study to evaluate precision and comparability of the new asssys with CEDIA drugs of abuse tests on Hitachi 917 in different laboratories (three European and three US). The assays were calibrated in the nonlinear mode with four to six standards (semiquantitative application). Initial within-run (21 replicates, four labs) and between-day (10 days, two labs) imprecision studies using Abuscreen OnLine tests and commercial negative (0.5 x cut-off) and positive (1.5 x cut-off) controls revealed the following median CVs [withinrun neg./pos. control/between-day neg./pos. control]: amphetamines 1.9/1.3/3.4/2.4, barbiturates 3.0/1.6/3.9/3.1, benzodiazepines 4.7/1.5/6.3/3.0, cocaine metabolite 1.8/0.9/2.4/1.7, methadone 5.4/1.6/5.5/2.2, opiates 5.5/2.8/5.3/2.7, THC 8.9/4.8/21.8/12.1. CVs < 10% were obtained for the THC test using controls with concentrations closer to the cut-off. An identical set of 170 GC/MS analyzed urine samples was distributed to the six laboratories and measured with Abuscreen OnLine tests on Hitachi 917. The median values for each individual sample were calculated and compared with the results obtained on individual Hitachi 917 analyzers by Passing-Bablok regression analysis. A good agreement between the laboratories was found with less than +/- 11% slope deviation and intercepts below 7% of the cut-off except for benzodiazepines (one slope 17%, one slope--26%) and THC (one slope 34%, one slope--18%). The comparability with CEDIA tests was analyzed by concordance plots using randomized routine samples in three laboratories. The following results were obtained in one of the participating laboratories [cut-off ng/mL] (No. of positive/negative/discrepant samples): amphetamines [500] 2/147/0, barbiturates [200] 1/148/0, benzodiazepines [100] 52/91/7, cocaine metabolite [300] 17/129/3, methadone [300] 113/34/2, opiates [300] 31/114/4, THC [50] 66/81/2. GC/MS was performed for clarification of the discrepant results. In summary, Abuscreen OnLine tests on Hitachi 917 give precise results which compare well when analyzed in different laboratories. They can be rated as convenient and flexible methods for drugs of abuse screening in the routine.

Amphetamines↗

alpha-1-Microglobulin: epidemiological indicator for tubular dysfunction induced by cadmium?

OBJECTIVES: To evaluate the suitability of alpha-1-microglobulin as a marker for cadmium induced renal dysfunction. METHODS: alpha-1-Microglobulin was studied in a cross sectional survey in relation to the body burden of cadmium. Concentrations of alpha-1-microglobulin in 24 h urine of 831 people aged 2-87 years were analysed in association with urinary cadmium excretion, cadmium blood concentration, age, sex, occupational and smoking history, and estimated creatinine clearance. Participants came from a population residentially exposed to cadmium and from two control populations matched for socioeconomic status. RESULTS: The excretion of alpha-1-microglobulin/24 h ranged from 0.1 mg to 176.3 mg and 44.4% of samples showed concentrations near the detection limit. Ordinal logistic regression analysis of people of all ages identified a high risk only for males compared with females (odds ratio (OR) 2.14; 95% confidence interval (95% CI) 1.56 to 2.94), age group, and duration of living on contaminated soil (OR 1.03/year; 95% CI 1.02 to 1.04), but not urinary cadmium excretion (OR 1.30; 95% CI 0.96 to 1.77) as significant predictors. For people < or = 50 years of age a weaker effect of sex (OR 1.76; 95% CI 1.13 to 2.73) and age group and an effect of similar magnitude for the duration of soil exposure (OR 1.03; 95% CI 1.01 to 1.04) were found. Also, the urinary cadmium excretion (OR 2.26; 95% CI 1.38 to 3.70) and occupational exposure (OR 1.71; 95% CI 1.03 to 2.83) were found to be significant in this younger age group. The estimated creatinine clearance had no significant impact on the alpha-1-microglobulin excretion. CONCLUSION: alpha-1-Microglobulin is a suitable marker for early tubular changes only for people < or = 50 years. It may not be sufficiently specific for cadmium, and therefore not a suitable surrogate for cadmium exposure in epidemiological studies.

Adolescent↗

[Must the recurrent nerve in thyroid gland resection always be exposed? A prospective randomized study].

It was the purpose of this study to establish whether it is necessary to identify the recurrent laryngeal nerve intraoperatively when resecting the endemic nodular goiter. We prospectively formed two groups from 800 subtotal unilateral resections ("nerves at risk"). In group I (382 subtotal resections, 48.4%) the nerve was not identified intraoperatively. In group II (413 subtotal resections, 51.6%) the recurrent laryngeal nerve was routinely identified in all cases. The operative technique was standardized, giving special attention to the "anterior lamella". For all patients, preoperative and postoperative evaluation of the vocal cords was performed routinely. Altogether we saw 4 (0.5%) transient vocal cord palsies: 2 in group I and 2 in group II. All 4 laryngeal nerve palsies recovered within 4 months. These data demonstrated that no benefit is gained from routine dissection of the laryngeal nerve during resection of endemic nodular goiter. Therefore the demand for obligatory intraoperative identification of the recurrent nerve is not tenable.

Adult↗

Broviac catheter insertion: operating room or neonatal intensive care unit.

We reviewed the records of all infants hospitalized in the neonatal intensive care unit (NICU) who underwent insertion of a Broviac catheter from July 1, 1984 through August 30, 1985. Eighty-six catheters were inserted in 81 patients. Thirty-one catheters were inserted in the NICU and the remainder were inserted in the operating room (OR). The patient's average weight at the time of catheter insertion was the same in both groups. Fifty-two of the 55 OR catheters (95%) were inserted in the external or internal jugular vein while only 68% of the NICU catheters were placed in the jugular veins. Six of the NICU catheters (19%) and 11 of the OR catheters (20%) developed catheter-associated sepsis with positive blood cultures. The infection rate per catheter day was similar in both groups as was the incidence of catheter occlusion. The NICU catheters were in place for an average of 51 days, and there was an average 46 day lifespan for the OR inserted catheters. Broviac catheter insertion can safely be performed in the NICU without an increase in morbidity. Broviac catheter insertion in the NICU is less costly and saves transportation of the sick neonate to the operating room.

California↗

[Tetanus].

Explore the source record for details and available documents.

Child↗