PubMed Health⌕ Search

Biomedical subjects

M Borchardt

Publications and source records attributed to M Borchardt.

9 recordsLinked to original sources

A disposable biosensor for urea determination in blood based on an ammonium-sensitive transducer.

A potentiometric urea-sensitive biosensor using a NH4(+)-sensitive disposable electrode in double matrix membrane (DMM) technology as transducer is described. The ion-sensitive polymer matrix membrane was formed in the presence of an additional electrochemical inert filter paper matrix to improve the reproducibility in sensor production. The electrodes were prepared from one-side silver-coated filter paper, which is encapsulated for insulation by a heat-sealing film. A defined volume of the NH4(+)-sensitive polymer matrix membrane cocktail was deposited on this filter paper. To obtain the urea-biosensor a layer of urease was cast onto the ion-sensitive membrane. Poly (carbamoylsulfonate) hydrogel, produced from a hydrophilic polyurethane prepolymer blocked with bisulfite, served as immobilisation material. The disposable urea sensitive electrode was combined with a disposable Ag/AgCl reference electrode to obtain the disposable urea biosensor. The sensor responded rapidly and in a stable manner to changes in urea concentrations between 7.2 x 10(-5) and 2.1 x 10(-2)mol/l. The detection limit was 2 x 10(-5) mol/l urea and the slope in the linear range 52 mV/decade. By taking into consideration the influence of the interfering K(+)- and Na(+)-ions the sensor can be used for the determination of urea in human blood and serum samples (diluted or undiluted). A good correlation was found with the data obtained by the spectrophotometric routine method.

Biosensing Techniques↗

Review of the clinical pharmacology and use of the benzodiazepines.

Benzodiazepines are commonly used in the perioperative period for the anxiolytic and amnestic effects they provide. The purpose of this article is to provide an understanding of the clinical pharmacology and mechanism of action for these agents, as well as the knowledge needed for the safe administration of benzodiazepines. The benzodiazepines most commonly used in the perioperative period are presented along with important facts and information regarding their use. The effected organ systems and drug interactions are also presented. Discussion of the benzodiazepine reversal agent, flumazenil, is included, followed by a discussion of nursing interventions.

Anti-Anxiety Agents↗

In vivo incorporation of C14-1-acetate into liver and plasma lipids of postnatally overfed rats.

Postnatal overnutrition due to breeding of rats in small nests (4 pups per dam) leads to distinct metabolic changes in later life stages even in conditions of ad libitum feeding. At an age of 5 months rats from small nests differ from those of large nests (14 pups per dam) in a significant higher level of liver triglycerides and cholesterol esters, whereas changes in plasma lipids concern only the increased cholesterol ester fraction. The relative distribution of in vivo incorporated C14-1-acetate into liver lipids shows a higher moiety in the triglyceride fraction of animals from small nests but no changes of the relative distribution of activity among lipid fractions of plasma. These changes of lipid metabolism are discussed in relation to the development of an obese state of postnatally overfed animals.

Acetates↗