PubMed Health⌕ Search

Biomedical subjects

M Brachman

Publications and source records attributed to M Brachman.

11 recordsLinked to original sources

Use of OncoScint scan to assess resectability of hepatic metastases from colorectal cancer.

Patients with limited hepatic metastases from colorectal cancer can potentially be cured by resection. A number of patients deemed resectable by standard imaging procedures are found to have extrahepatic disease at laparotomy and are thus unresectable. A test capable of identifying these patients would assist in better patient selection. OncoScint (Cytogen Corp, Princeton, NJ) scan targets colorectal cancer by interacting with a tumor-associated glycoprotein. Can OncoScint scan be used to reliably identify patients with extrahepatic disease preoperatively? Between February 1996 and August 1998 eight patients with colorectal metastases to the liver were enrolled prospectively. All patients received preoperative OncoScint scan (indium-111) and underwent laparotomy. The laparotomy findings were correlated with the results of OncoScint scan. In four of eight patients (50%) OncoScint scan showed no extrahepatic disease. This was confirmed at laparotomy. All of these patients underwent hepatic resection. One of eight patients (12.5%) had OncoScint findings suggestive of extrahepatic disease pathologically confirmed during laparotomy. Three of eight patients (37.5%) had OncoScint findings of extrahepatic disease not confirmed by laparotomy. All three patients underwent hepatic resection. One of the three patients is still disease free for more than 48 months after hepatic resection. If OncoScint scan had been used to determine resectability this patient with false positive scan would have been denied a potentially curative operation. Because of the unacceptably high false positive rate the study was terminated after eight patients. Because of its high false positive rate (37.5%) OncoScint scan is not a reliable test for the assessment of extrahepatic disease. Other tests need to be developed to accurately stage extrahepatic disease with an acceptably low false positive rate to prevent exclusion of patients who can potentially be cured.

Aged↗

Winning the bug war.

Explore the source record for details and available documents.

Bacterial Infections↗

Comparison of gallium-67-citrate and thallium-201 scintigraphy in peripheral and intrathoracic lymphoma.

UNLABELLED: We performed this study in an attempt to reconcile the differences with respect to 67Ga uptake as a function of tumor grade and type in the literature, as well as to determine the sensitivity of 201Tl uptake in both Hodgkin's and non-Hodgkin's lymphoma. METHODS: Thirty-six (9 with low-grade lymphoma, 11 with intermediate-grade lymphoma, 4 with high-grade lymphoma and 12 with Hodgkin's lymphoma) patients underwent both 67Ga and 201Tl scintigraphy. Biopsies were done on all patients. A semiquantitative rating system was used to make statistical comparisons for thallium versus gallium in all lymphoma subgroups, as well as comparisons of thallium and gallium to themselves in all subgroups. RESULTS: Patient sensitivity was only 56% and site sensitivity was 32% in patients with low-grade lymphoma. Conversely, 201Tl sensitivity was 100%, respectively, for patients and sites. The difference between 201Tl and 67Ga sensitivity in patients with low-grade lymphoma on a site basis was statistically significant. When compared to itself in lymphoma subgroups, 201Tl was found to be statistically more avid for low-grade lymphoma than for intermediate, high or Hodgkin's lymphoma. Gallium-67 sensitivity for low-grade lymphoma was significantly less than for Hodgkin's and intermediate grade lymphomas. No significant differences were found when 201Tl and 67Ga were compared in the intermediate, high or Hodgkin's lymphoma groups. CONCLUSION: Thallium-201 demonstrates significantly greater tumor avidity in the low-grade lymphoma group compared to 67Ga citrate. Gallium-67-citrate appears relatively nonavid for low-grade lymphoma compared to 201Tl and is statistically inferior in detecting low-grade lymphoma in comparison to its ability to detect intermediate or high-grade lymphomas. Gallium-67-citrate should not be considered dependable in evaluating patients with low-grade lymphoma. Neither 201Tl or 67Ga is dependable in the evaluation of low-grade lymphoma within the abdomen, since gallium avidity for low-grade lymphoma is low and gastrointestinal excretion of 201Tl is poorly controlled.

Biopsy↗

Quantitative computerized joint scanning in rheumatoid arthritis: an accurate reproducible method of quantitating synovitis--preliminary report.

Clinical trials in rheumatoid arthritis have been hampered by the highly subjective nature of disease assessment measures and lack of a consistently reliable laboratory test to follow. The authors devised a method of quantitating synovitis by computerized joint scanning and compared it with six conventional parameters in 18 patients entered into two treatment protocols and a control group. The results indicate that quantitative joint scanning probably is at least as reliable as the conventional measures and has the advantage of having no placebo or subjective component.

Adult↗

Enhanced detection of proximal right coronary artery stenosis with the additional analysis of right ventricular thallium-201 uptake in stress scintigrams.

The value of right ventricular thallium-201 analysis in detecting proximal right coronary artery stenosis in exercise myocardial scintigraphy was analyzed in 52 patients, 27 with and 25 without proximal right coronary artery stenosis. For the detection of proximal right coronary artery stenosis, the sensitivity and specificity of thallium scintigraphic analysis were 59 and 88% for a right ventricular abnormality, 67 and 68% for a left ventricular inferior wall abnormality, and 93 and 56% for an abnormality of either. When both right and left ventricular thallium images were abnormal, all 9 patients had proximal right coronary artery stenoses, and when both were normal, 26 of 28 patients had a normal proximal right coronary artery. The sensitivity and specificity of blood pool scintigraphic variables during exercise (right ventricular ejection fraction and left ventricular inferior wall motion) were not significantly different for detection of proximal right coronary artery stenosis. Thus, the additional analysis of the right ventricle on thallium-201 stress scintigrams can improve the detection of proximal right coronary artery stenosis. When both right ventricular and left ventricular thallium scintigrams are abnormal (or normal), the ability to predict the presence (or absence) of proximal right coronary artery stenosis is very high.

Adult↗

The significance of 1-131 scan dose in patients with thyroid cancer: determination of ablation: concise communication.

Twenty-four patients with differentiated thyroid cancer were studied with diagnostic I-131 neck chest scans after having undergone bilateral subtotal thyroidectomy and initial I-131 therapy with either 30- or 100-mCi doses. With an endogenous stimulation protocol, follow-up studies were performed with neck and chest scans using 2 and 10 mCi I-131. A 400% increase in sensitivity was found with a 10-mCi dose relative to a 2-mCi dose. Comparison with therapeutic doses of 30 and 100 mCi resulted in further increases in the detection of residual iodine-avid tissue. We conclude that a 2-mCi or lower dose of I-131 is inadequate in evaluating residual iodine-avid tissue visually in patients with thyroid cancer. The study does not answer the critical question of whether it is necessary to treat a patient presenting a negative 2-mCi but a positive 10-mCi scan. It may be appropriate to define ablation visually as well as clinically, with further studies directed toward determining a treatment rationale in this patient population.

Adenocarcinoma↗

False-positive lung imaging: inadvertent injection into a pulmonary artery catheter.

A case of a ventilation-perfusion mismatch seen post-operatively in a patient with chest pain is reported. There was absence of perfusion to the right lung, with relatively normal ventilation. The study was initially interpreted as indicating a high probability of pulmonary embolus. It was then discovered that the injection had been inadvertently made into a Swan-Ganz catheter, with its tip in the left main pulmonary artery. The mismatch was therefore iatrogenic and not related to pulmonary embolus. The false-positive lung imaging which resulted has not been previously reported in the literature.

Aged↗