PubMed Health⌕ Search

Biomedical subjects

M Brischwein

Publications and source records attributed to M Brischwein.

12 recordsLinked to original sources

Multiparametric microsensor chips for screening applications.

The identification of drug targets for pharmaceutical screening can be greatly accelerated by gene databases and expression studies. The identification of leading compounds from growing libraries is realized by high throughput screening platforms. Subsequently, for optimization and validation of identified leading compounds studies of their functionality have to be carried out, and just these functionality tests are a limiting factor. A rigorous preselection of identified compounds by in vitro cellular screening is necessary prior to using the drug candidates for the further time consuming and expensive stage, e.g. in animal models. Our efforts are focused to the parallel development, adaptation and integration of different microelectronic sensors into miniaturized biochips for a multiparametric, functional on-line analysis of living cells in physiologically environments. Parallel and on-line acquisition of data related to different cellular targets is required for advanced stages of drug screening and for economizing animal tests.

Biocompatible Materials↗

Simultaneous measurement of cellular respiration and acidification with a single CMOS ISFET.

In vivo, the pH value and oxygen partial pressure are the most important physico-chemical parameters in the microenvironment of human tissues. In vitro, the extracellular acidification rate of cell cultures is an indicator of global cellular metabolism, while the rate of oxygen consumption is a measure of mitochondrial activity. Earlier approaches had the disadvantage that these two values had to be measured with two separate sensors at different loci within the tissue or cell culture. Furthermore, conventional Clark-type oxygen sensors are not very compatible for miniaturisation, making it impossible to measure at small cell volumes or even at the single cell level. We have, therefore, developed an ISFET based sensor structure which is able to measure both pH and oxygen partial pressure. This sensor structure was tested in vitro for simultaneous records of cellular acidification and respiration rates at the same site within the cell culture. This sensor is manufactured by a CMOS-process.

Biosensing Techniques↗

Approach to a multiparametric sensor-chip-based tumor chemosensitivity assay.

Although not widely practiced by oncologists, in vitro tumor chemosensitivity assays (TCA) have proved to increase the lifetime of tumor patients in prospective clinical trials. By individualizing cancer therapy, they can support the clinician's decision which is usually based on empirically retrieved data and thereby prevent inadequate chemotherapy. We present the first results of a new sensor-chip-based technology which might be useful for a multiparametric TCA. In particular, the aspect of dynamic on-line data generation on intact cellular specimens is a major difference to alternative assays. A series of experiments has been performed on cell lines and human tumor explants. Cell cultures and tumor tissue explants were placed on miniaturized silicon and glass sensor chips. The sensor data currently analyze metabolic profiles (rates of extracellular acidification and cellular oxygen consumption) and changes in cell morphology (monitoring of electric impedance). With the cell lines, drug-associated cellular signals have been detected with all three parameters, while primary explants so far caused metabolic responses only. In particular, cellular respiration or mitochondrial activity seems to be a most sensitive indicator of acute cytotoxic effects. The experimental results were achieved using different test versions. Besides giving a status report, the theoretical potential and current problems of sensor chip technology in TCA is discussed.

Acetaldehyde↗

Non-invasive measurement of cell membrane associated proton gradients by ion-sensitive field effect transistor arrays for microphysiological and bioelectronical applications.

The pH in the cellular microenvironment (pH(M)) is an important regulator of cell-to-cell and cell-to-host interactions. Additionally the extracellular acidification rate of a cell culture is an important indicator of global cellular metabolism. In a new approach a biocompatible ion-sensitive field effect transistor (ISFET)-array was developed to measure the pH(M) close to a surface and the global extracellular acidification rate at the same time. This ISFET-array is part of a new multiparametric microsensor chip. The paper highlights some basic applications of this method for in-vitro measurements. Using a fluid perfusion system for cell culture media, it is possible to measure the pH(M) of few (five to ten) adherent tumor cells in a distance of 10-100 nm from the cell plasma membrane. Experiments showed a pH(M)-value of 6.68 +/- 0.06 pH. Further experiments suggest that both the low pH, and the extracellular acidification rate of the examined tumor cell line are mainly built up by glycolysis.

Biosensing Techniques↗

Monitoring of cellular signalling and metabolism with modular sensor-technique: the PhysioControl-Microsystem (PCM).

Microsensors provide instruments particularly suited for the noninvasive analysis of cell and tissue cultures. The outstanding benefit lies in the passive behaviour of continuously working transducers, which in turn allows the dynamic recording of function-specific cellular processes. The microsensor system presented in this paper is a modular arrangement of various planar and non-planar sensor elements surrounding small cell culture chambers. An optic access to the cultures (e.g. for high resolution light microscopy and spectro-photometric techniques) enables a parallel and comparative data acquisition. The system was originally designed for biomedical research in chemotherapy and pharmacology but it proved to be an effective device both for toxicological and environmental research.

Biosensing Techniques↗

On-line control of cellular adhesion with impedance measurements using interdigitated electrode structures.

Critical parameters to be assessed in cell culture are the number of viable cells and cell viability. Growth, product formation, toxicity effects and the overall success of cell culture can depend largely on these. With interdigitated electrode structures (IDES) adherent cells are cultured directly on a pair of interdigitated electrodes, and the impedance of the system gives insight into the adhesive behaviour of the cells. The signal is influenced by the changes in number, growth and morphological behaviour of adherently growing cells, mainly owing to the insulating effects of the cell membranes. Five different cell lines are used, and their divergent behaviour is monitored over a period of four days, from inoculation of the cells to killing of the cells at the end of the experiments. Even when the cells from close monolayers, great fluctuations in the impedance signal can be observed. Nevertheless, for a more complete description of cellular systems, other parameters, such as acidification and respiration, have to be included in the measuring system.

Biosensing Techniques↗

Microsensor-aided measurements of cellular signalling and metabolism on tumor cells. The cell monitoring system (cms(R)).

Microsensors provide instruments particularly suited for the rapid, noninvasive and on-line analysis of cell and tissue cultures. The microsensor system presented in this paper is a modular arrangement of various planar and nonplanar sensor elements for the measurement of physiological parameters of cell cultures. An optic access to the cultures (e.g. for light microscopy and spectrophotometric techniques) is also provided for a parallel and comparative data acquisition. The system was originally designed for biomedical research in chemotherapy (predicative chemotherapy assays) and pharmacology but it turned out to be also an effective tool for toxicological and environmental research.

Biosensing Techniques↗

Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures.

A new method for on-line and real-time monitoring of concentration, growth and physiological state of cells in culture is described. This biosensor is based on impedance measurements of adherently growing cells on interdigitated electrode structures (IDES). The measurements can be performed for several days as there is no detectable electrical influence on the cells. The versatility of this new sensor is shown with some exemplary experiments. Cell density, growth and long-term behaviour of cells on the electrodes clearly change the impedance of the IDES. Both, the global influence of serum components (deprivation of foetal bovine serum) and the toxic effects of heavy metal ions (cadmium) result in changes of the sensor signal and can be visualized.

Animals↗

[Microsensory systems in cell biology basic research and medical diagnostics].

The development of an integrated sensor system, called the physiocontrol microsystem, is presented. It is suited for microscopy, and works with both adherent cell types and cultures growing in suspension, as well as with tissue biopsies. The central part, a miniaturized culture chamber equipped with differently constructed microsensors, allows continuous observation of important physiological parameters even in the course of long-lasting experiments. Besides a description of the physical components, the study provides a summary of selected applications of the physiocontrol microsystem in basic cellular research and biomedical diagnostics.

Animals↗

Analysis of the redox reaction of an archaebacterial copper protein, halocyanin, by electrochemistry and FTIR difference spectroscopy.

Halocyanin is a recently discovered archaebacterial copper protein classified as "type I" small blue copper protein (Scharf, B., Ph.D. Thesis, University of Bochum, Germany). Its redox properties were investigated by a combination of protein electrochemical and spectroscopic techniques. Using electrochemical reactions in an ultrathin-layer electrochemical cell developed for UV/vis and IR spectroscopy, halocyanin could be quantitatively and reversibly oxidized and reduced. The titration of the absorption band at 600 nm can be perfectly described by a Nernst curve with n = 1 electron transferred; a quantitative fit yields a midpoint potential, Em, of 183 mV (vs SHE) at a pH of 7.3. The midpoint potential falls constantly from +333 mV at pH 4 to +119 mV at pH 10, with three regions around pH 4.5, 6.5, and 8.5 where the pH dependence is ca. -60 mV/pH unit, indicating the uptake of a proton with the reduction. By analogy with other small type I copper proteins, the three pK values suggested by the pH dependency of Em might be associated with three histidines which interact with the redox site. Electrochemically induced reduced-minus-oxidized Fourier transform infrared difference spectra in the 1800-1000 cm-1 range at neutral pH show a number of strong difference bands between ca. 1700 and 1600 cm-1 as well as smaller difference structures between 1600 and 1200 cm-1. The maximum amplitude of the difference bands--only ca. 1% of the amide-I absorption at ca. 1639 cm-1--indicates that only small protein rearrangements occur upon the redox transition.(ABSTRACT TRUNCATED AT 250 WORDS)

Archaea↗