PubMed Health⌕ Search

Biomedical subjects

M Burghoff

Publications and source records attributed to M Burghoff.

At least 19 recordsLinked to original sources

[High resolution EEG and whole head MEG].

A low-noise multichannel EEG-Amplifier-System has been designed and analyzed, which is electromagnetically compatible with SQUIDs. The EEG- together with the MEG-System is operated inside the quiet environment of a magnetically shielded room, hence no electrical 50 Hz-Artifact is detectable. Measurements pointed out that the influence of amplifier- and electrochemical-noise of electrodes to averaged EEG-spectral densities is less than 1% within the frequency range 0.5 to 70 Hz. Thermal noise of the skin-electrode-interface, equivalent to a resistor of 30 k omega, only begins to take effect above 20 Hz, suggesting that there is no need of skin abrasion.

Alpha Rhythm↗

Magnetoneurography of evoked compound action currents in human cervical nerve roots.

OBJECTIVE: A measurement protocol for magnetoneurography (MNG) is established which allows the non-invasive localization and tracing of evoked compound action currents propagating along cervical nerve roots in man. METHODS: Inside a magnetically shielded room either both median or both ulnar nerves of healthy subjects were conventionally electrostimulated in alternation. Evoked magnetic responses were recorded using a multichannel SQUID-detector with a planar measuring area centered over the neck. Simultaneously, electric surface potentials were recorded using cervical bipolar electrode montages. RESULTS: Upon median (ulnar) nerve stimulation somatosensory evoked magnetic fields up to 20 fT (10 fT) amplitude were detected propagating over the cervical transforaminal root entry zone, with corresponding electrical surface potentials of 1.5 microV (0.5 microV). Furthermore, the signal-to-noise ratio of the spatiotemporal magnetic field mappings in median nerve stimulation experiments allowed dipolar source reconstructions and tracing of the propagation of the compound action currents along nerve root fibers. CONCLUSION: Magnetoneurography allows tracing of the propagation of evoked compound action currents along cervical roots in healthy subjects with millisecond temporal and high spatial resolution. Thus, MNG offers a sensitivity appropriate to serve as a clinical diagnostic tool for localizing focal neuropathies of cervical nerve roots.

Electric Conductivity↗

Tracing of proximal lumbosacral nerve conduction--a comparison of simultaneous magneto- and electroneurography.

OBJECTIVE: The reconstruction of nerve impulse conduction along proximal lumbosacral plexus and nerve roots is compared using simultaneous magneto- and electroneurography. METHODS: In 3 healthy subjects the left tibial nerve was electrostimulated at the ankle. Evoked magnetic fields and electric surface potentials were measured simultaneously over the lumbosacral spine using a multichannel SQUID-detector with a planar measuring area and 25 surface electrodes covering a comparable area centered around L4. Based on either magnetic field or electric potential maps the depolarization front of the evoked compound action currents (CAC) was spatio-temporally reconstructed using a simple equivalent current dipole model in a half-space volume conductor. RESULTS: The mean signal-to-noise ratio in the magnetic (electric) recordings was around 4 (8). Yet, the localization quality for the propagating CAC was lower for electric than magnetic recordings. The local nerve conduction velocity was around 47 m/s (calculated from magnetic data), but fluctuated unphysiologically for electric data. CONCLUSION: In comparison to electroneurography, an anatomically reasonable localization of evoked compound action currents propagating in lumbosacral roots can be obtained by magnetoneurography.

Adult↗

Non-invasive magnetoneurography for 3D-monitoring of human compound action current propagation in deep brachial plexus.

Compound action current (CAC) propagation along nerve fibers running deep in the human brachial plexus was 3D-visualized based on non-invasive 49-channel superconducting quantum interference device (SQUID) magnetoneurography. Spatio-temporal mappings over the upper thoracal quadrant of magnetic fields (<100 fT) evoked upon alternating median and ulnar nerve stimulation in seven healthy volunteers showed consistently smoothly propagating dipolar patterns for both the CAC depolarization and repolarization phases. Multipolar current source reconstructions (i) distinguished spatially CAC propagation pathways along either median or ulnar plexus fibers, allowed (ii) to calculate local conduction velocities ( approximately 56 m/s) and (iii) even to estimate the CAC extension along the nerve fibers (depolarization phase: approximately 11 cm). Thus, for deep proximal nerve segments magnetoneurography can provide a detailed tracing of neural activity which is a prerequisite to localize non-invasively focal nerve malfunctions.

Action Potentials↗

Conversion of magnetocardiographic recordings between two different multichannel SQUID devices.

Comparison of biomagnetic measurements performed with different multichannel magnetometers is difficult, because differing sensor types and locations do not allow measurements from the same locations in respect to the body. In this study, two transformation procedures were utilized to compare magnetocardiograms (MCG) recorded with two different multisensor systems. Signals from one sensor array were used to compute parameters of a multipole expansion or minimum-norm estimates at 1-ms steps over the cardiac cycle. The signals of the second sensor array were then simulated from the computed estimates and compared against measured data. Both the multipole- and the minimum-norm-based transformation method yielded good results; the average correlation between simulated and measured signals was 93%. Thus, the methods are useful to compare MCG recordings performed using differing sensor configurations, e.g., for multicenter patient studies. This study provides the first empirical basis for assessing the transformation of MCG data of differing devices by general model-based field reconstructions.

Biomedical Engineering↗

Non-invasive long-term recordings of cortical 'direct current' (DC-) activity in humans using magnetoencephalography.

Recently, biomagnetic fields below 0.1 Hz arising from nerve or muscle injury currents have been measured non-invasively using superconducting quantum interference devices (SQUIDs). Here we report first long-term recordings of cortical direct current (DC) fields in humans based on a horizontal modulation (0.4 Hz) of the body and, respectively, head position beneath the sensor array: near-DC fields with amplitudes between 90 and 540 fT were detected in 5/5 subjects over the auditory cortex throughout prolonged stimulation periods (here: 30 s) during which subjects were listening to concert music. These results prove the feasibility to record non-invasively low amplitude near-DC magnetic fields of the human brain and open the perspective for studies on DC-phenomena in stroke, such as anoxic depolarization or periinfarct depolarization, and in migraine patients.

Acoustic Stimulation↗

Magnetometry of injury currents from human nerve and muscle specimens using superconducting quantum interferences devices.

Acute lesions of polarized membranes lead to slowly decaying ('near-DC') injury currents driven by the transmembrane resting potential gradient. Here we report the first recordings of injury-related near-DC magnetic fields from human nerve and muscle specimens in vitro using Superconducting Quantum Interference Devices (SQUIDs) operated in a conventional magnetically shielded room in a clinical environment. The specimen position was modulated sinusoidally beneath the sensor array by a non-magnetically fabricated scissors lift to improve the signal-to-noise ratio for near-DC fields. Depending on the specimen geometry the field patterns showed dipolar or quadrupolar aspects. The slow decay of human nerve and muscle injury currents was monitored for several hours from a distance of a few centimeters. Thus DC-magnetometry provides a sensitivity which might allow the remote detection of injury currents also in vivo.

Animals↗

Magnetoneurographic 3D localization of conduction blocks in patients with unilateral S1 root compression.

OBJECTIVES: Tibial nerve somatosensory evoked magnetic fields (tSEFs) over the lower back reflect the propagation of compound action currents along fibers of plexus, nerve roots and cauda equina. One clinical perspective for this 'magnetoneurography' is the non-invasive 3D localization of focal slowing or blocks of conduction. Here, first tSEF mappings in 3 consecutive patients with acute unilateral S1 nerve root compression are reported. METHODS: Right and left tibial nerves were electrostimulated in alternation; tSEF responses were recorded using a multichannel SQUID-detector; additionally, spinal and cortical SEP, F-wave and H-reflex studies were performed. RESULTS: In all patients an intraindividual side-to-side comparison of spinal tSEF mappings was obtained: using a dipolar source model compound action currents could be visualized propagating along plexus, nerve roots and cauda equina on the non-affected side whereas on the affected side normally-propagating dipolar field patterns could be recorded only distal to the spinal transforaminal root entrance; this reflects focal slowing or block of conduction in nerve root fibers as indicated by the SEP, F-wave and H-reflex study results. CONCLUSIONS: With a registration time of 15 min a 3D localization of proximal slowing or block of conduction was successfully performed in patients suffering from acute nerve root lesions.

Cauda Equina↗

Somatotopic source arrangement of 600 Hz oscillatory magnetic fields at the human primary somatosensory hand cortex.

Based on low-noise superconducting quantum interference devices (SQUIDs) magnetoencephalography allows the non-invasive detection of low-amplitude high-frequency brain responses evoked about 20 ms after electric hand nerve stimulation. The main spectral energy of these brief oscillatory bursts (near 600 Hz) is in the range typical for rapidly repeated action potentials. Here, the magnetic fields of median and ulnar nerve evoked 600 Hz bursts are shown to exhibit a somatotopic arrangement at the primary somatosensory hand cortex closely resembling that of the concomitant postsynaptic primary cortical response (¿N20m'). Two possible burst generators are discussed: (1) repetitive spike volleys conducted along the terminal segments of somatotopically arranged thalamocortical axons, and (2) early intracortical spike activity in nerve-specific subterritories of the 3b hand area.

Brain Mapping↗

Visuo-motor adaptation: evidence for a distributed amplitude control system.

We investigated the constraints for visuo-motor adaptation in human pointing movements. Subjects pointed at sequentially presented visual targets while visual feedback about their finger position was either absent (pre- and post-period), or was manipulated such as to require a gradual reduction of response amplitude (per-period). We found that response amplitudes were smaller during the post- than during the pre-period, which documents the existence of adaptation to distorted visual feedback. We further found that adaptation can transfer fully to untrained amplitudes (Exp. 1), although the amount of transfer may be reduced if trained and untrained amplitudes are substantially different (Exp. 2). However, selective adaptation of one amplitude but not another can also be yielded if the paradigm explicitly asks for it (Exp. 3), and if the two amplitudes differ by more than about 10 cm (Exp. 4). We conclude from these findings that the adapted mechanism consists of amplitude-specific elements, tuned to amplitude spans of some 10 cm.

Adaptation, Physiological↗

Mapping of tibial nerve evoked magnetic fields over the lower spine.

Using a low-noise 49-channel dc-SQUID system spinal somatosensory evoked fields (SEF) were recorded which were generated by compound action currents evoked upon posterior tibial nerve stimulation. The SEF mapping showed the action current propagation along the sciatic nerve, lumbosacral plexus and cauda equina in parallel to simultaneously recorded electrical potentials (SEP). For a reliable intraindividual side-to-side comparison of spinal SEFs the right and left tibial nerves were stimulated in alternating order; this procedure minimizes artifactual inter-nerve SEF map differences due to eventual patient-to-sensor displacements which might occur in serial measurements. These large-area lumbar SEF mappings open up several clinical perspectives for magnetoneurography, in particular with respect to the 3D-localization of proximal conduction blocks.

Adult↗

Magnetocardiography and 32-lead potential mapping: repolarization in normal subjects during pharmacologically induced stress.

Signals from 37 magnetocardiographic sensors and simultaneously recorded 32 ECG leads were obtained in three healthy male subjects (including two reinvestigations). After recordings at rest, the heart rate was increased by pharmacologic stress (117 to 142 beats/min). Comparison of the repolarization of rest and stress showed substantial changes in the magnetocardiogram (MCG) up to T wave inversions during stress. In the ECG only junctional ST-T segment shifts were present. For quantification, correlation coefficients between pairs of rest and stress MCG and rest and stress ECG distributions were calculated for the same time instant at the beginning of T wave under rest and stress conditions. In addition, equivalent electrical current dipole moment and magnetic dipole moment vectors were calculated from the MCG, and their change from rest to stress evaluated. Correlation coefficients for MCG comparison ranged from 0.3 to 0.5; ECG comparison suggested much less change from stress, ranging from 0.7 to 1.0. Current dipole moment changes at T wave onset were marginal; in contrast, the magnetic dipole moment changed substantially. Since the magnetic dipole reflects vortex currents, changes in its intensity and/or orientation during repolarization suggest this as the biophysical basis of the striking difference in the response of the MCG and ECG to pharmacologic stress. Normal ECG findings at rest and under stress in healthy subjects support the conclusion that the repolarization changes in the MCG were of nonpathologic origin.

Adult↗