Left ventricular function during support with an asynchronous pulsatile left ventricular assist device.

BACKGROUND: Left ventricular assist devices (LVADs) are frequently used to maintain patients with severe heart failure until heart transplantation becomes possible. Some patients may experience recovery of LV function during such support. Therefore, it is essential to be able to monitor changes in LV function in this setting. METHODS: We studied LV function in 10 patients (median age 34 years, 9 male) who had LVADs implanted because of severe heart failure due to dilated cardiomyopathy a median of 4 months previously. Median pre-implant ejection fraction was 27% and all patients had been on maximal medical therapy, including intravenous inotropic support, prior to insertion of the LVAD. RESULTS: During LVAD support there were cyclical variations in LV dimensions, fractional shortening (FS) and transmitral flow, related to changes in the phase relationship of the LV and the LVAD. The "best" FS occurred when LV systole coincided with device filling and the "worst" FS when LV systole coincided with device ejection. Median FS with the pump switched off was 18% (10% to 32%). Pump-off FS was significantly greater than the "worst" FS with the pump on (5%, p = 0.002), and similar to the "best" pump-on FS (19%, p = NS). CONCLUSIONS: LV function could be studied echocardiographically during LV support and brief periods of interruption in support. Function varied according to the phase relationship of the LV and LVAD. The "best" FS measured during LVAD support was more closely related to the FS with the device switched off than the "worst" pump on FS. The "best" pump-on LV function is therefore most representative of intrinsic LV performance and can be used as a guide to recovery and the potential need for pump-off studies.

Adult↗

Systemic platelet effects of contrast media: implications for cardiologic research and clinical practice.

BACKGROUND: Angiographic contrast media cause platelet activation and decrease aggregability in vitro. We have previously shown in vitro a significant antiplatelet effect of contrast media at the concentrations obtained locally in the coronary artery during angioplasty. It is not known, however, whether a systemic effect is present. METHOD: Thirty patients undergoing diagnostic coronary angiography were prospectively randomized to receive the nonionic medium iohexol, ionic low-molecular-weight medium ioxaglate, or ionic high-molecular-weight medium diatrizoate. Platelet aggregability was measured before and after the investigation with whole blood electrical impedance aggregometry (WBEA) with collagen agonist and the PFA-100 (Dade, Miami, Fla) platelet function analyzer with combined shear, collagen, and adenosine diphosphate as agonists. RESULTS: With WBEA, with iohexol no difference in impedance change was seen: (medians and ranges) before, 9.8 Omega (4.8-19.2 Omega) versus after, 9.6 Omega (2-19.2 Omega) (P not significant [NS]). With ioxaglate a significant fall was seen: before, 8.6 Omega (6.4-15.2 Omega) versus after, 6.6 Omega (0-12.4 Omega) (P =.004). With diatrizoate a significant and greater fall was seen: before, 10.8 Omega (6.4-17.6 Omega) versus after, 6.6 Omega (0-10.8 Omega) (P =.002). With PFA, no difference in closure time was seen with any medium: iohexol before, 99 seconds (79-142 seconds) versus after, 142 seconds (63-128 seconds) (P NS); ioxaglate before, 120 seconds (75-258 seconds) versus after, 95 seconds (74-258 seconds) (P NS); and diatrizoate before, 114.5 seconds (65-250 seconds) versus after, 100.5 seconds (72-300 seconds) (P NS). CONCLUSIONS: Ionic but not nonionic contrast media have a systemic antiplatelet effect at diagnostic angiographic doses when measured with WBEA. Such an effect has not been shown before. This may explain the observed improved clinical outcome with ionic contrast media but also might confound platelet studies in coronary angioplasty.

Adult↗